• Title/Summary/Keyword: Flux Leakage

Search Result 310, Processing Time 0.03 seconds

The method of alignment detection between Tx and Rx set in wireless inductive charger (유도방식 무선충전기용 송수신 장치간 정렬상태 검출기법)

  • Lee, Sang Gon;Kim, Jae Moung
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.1
    • /
    • pp.90-96
    • /
    • 2014
  • This paper is about increasing transfer efficiency of wireless power transmission. The new method is proposed to detect the alignment of transmitter and receiver of wireless charger and so smart phone can display the position of wireless charging receiver on its LCD panel for the maximum charging efficiency. The previous method is only to show the transfer efficiency, but this method is to show not only the efficiency but also coordinates of receiver. The apparatus of the wireless charger is based on WPC(Wireless Power Consortium) standard and has planar air coil combined with magnet shield in Tx and Rx device so that the leakage flux is minimized on condition of under hundreds of kHz operating frequency. In this paper, it's showed that relation of magnet field and distance of each coils can be linearized and position information of Tx and Rx device is calculated thru trigonometry. Through the experiment, the obstacles of linearity are discovered and also showed that it can be optimized. and so the presented method is suitable for alignment detection method of Tx and Rx device in WPC wireless charger.

The Performance of Micro Fluxgate Sensor with Magnetic Core Shape (자성체 코어 형상에 따른 마이크로 플럭스게이트 센서의 검출 특성)

  • 조중희;최원열
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.508-514
    • /
    • 2004
  • A fluxgate magnetic sensor consists of a solenoid excitation coil, pick-up coil, and magnetic core. We presents the effect of magnetic core shape in a micromachined fluxgate sensor. To observe the performance of fluxgate sensor with magnetic core side width and gap, side width of 125 ${\mu}{\textrm}{m}$, 250 ${\mu}{\textrm}{m}$, and 500 ${\mu}{\textrm}{m}$ were designed in a rectangular-ring shaped core and the gaps of 0 ${\mu}{\textrm}{m}$, 50 ${\mu}{\textrm}{m}$, and 100 ${\mu}{\textrm}{m}$ were also fabricated in a racetrack shaped core. The solenoid coils and magnetic core were separated by benzocyclobutane(BCB) which had high insulation and good planarization characters. Copper coil patterns of 10 ${\mu}{\textrm}{m}$ width and 6${\mu}{\textrm}{m}$ thickness were electroplated on Ti(300 $\AA$) / Cu(1500 $\AA$) seed layers. 3 ${\mu}{\textrm}{m}$ thick N $i_{0.8}$F $e_{0.2.}$(permalloy) film for the magnetic core was also electroplated under 2000 gauss to induce the magnetic anisotropy. The magnetic core had the high DC effective permeability of ∼1,300 and coercive field of ∼0.1 Oe. Because the magnetic cores of 500 ${\mu}{\textrm}{m}$ side width and 0 gap had a low magnetic flux leakage, high sensitivity of ∼350 V/T were measured at excitation condition of 3 $V_{P-P}$ and 2 MHz square wave. The power consumption of ∼14 ㎽ was measured. The fabricated fluxgate sensor had the very small actual size of 3.0${\times}$1.7 $\textrm{mm}^2$. When two fluxgates were perpendicularly aligned in terrestrial field, their two-axis output signals were very useful to commercialize an electronic azimuth compass for the portable navigation system.m.m.m.

Studies on Preparation of Dysprosium-165 Metallic Macroaggregates for the Treatment of Rheumatoid Arthritis (류마티스 관절염 치료용 디스프로슘-165금속 응집입자($^{165}Dy-MA$)의 제조에 관한 연구)

  • Park, Kyung-Bae;Kim, Jae-Rok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.227-233
    • /
    • 1994
  • Irradiation of 20mg of natural $Dy(NO_3)_3$ in a neutron flux of $2{\times}10^{13}n/cm^2$ sec for 4 hours gave 5.76 Ci of $^{165}Dy$(specific activity, 610mCi/mg Dy) with high radionuclidic purity (>99.9 %). $^{165}Dy-MA$ was prepared in a quantitative yield by reacting the aqueous solution of $^{165}Dy(NO_3)_3$ with sodium borohydride solution in 0.2N NaOH. Coulter particle analyzer exhibited mean particle size of $2.6{\mu}m$ (range $1{\sim}6{\mu}m$), Even though the $^{165}Dy-MA$ suspension in saline was stored at $37^{\circ}C$ for 24 hours or autoclaved at $121^{\circ}C$ for 30minutes, there was no significant change in particle size and leakage problem indicating the prepared $^{165}Dy-MA$ is sufficiently stable. In-vivo retention studies were carried out by administering $^{165}Dy-MA$ into the knee joint space of normal rabbits. Gamma camera analysis showed high retention in joint space of normal rabbits. Gamma camera analysis showed high retention in joint space even at 24 hours after administration (> 99.9%). The ease with which the $^{165}Dy-MA$ can be made in the narrow size range and their high invitro and vivo stability make them attractive agents for radiation synovectomy.

  • PDF

GMR Sensor Applicability to Remote Field Eddy Current Defect Signal Detection in a Ferromagnetic Pipe (강자성 배관의 원격장 와전류 결함 신호 검출에 GMR Sensor의 적용성 연구)

  • Park, Jeong Won;Park, Jae Ha;Song, Sung Jin;Kim, Hak Joon;Kwon, Se Gon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.483-489
    • /
    • 2016
  • The typical methods used for inspecting ferromagnetic pipes include the ultrasonic testing (UT) contact method and the following non-contact methods: magnetic flux leakage (MFL), electromagnetic acoustic transducers (EMAT), and remote field eddy current testing (RFECT). Among these methods, the RFECT method has the advantage of being able to establish a system smaller than the diameter of a pipe. However, the method has several disadvantages as well, including different sensitivities and difficult-to-repair coil sensors which comprise its array system. Therefore, a giant magneto-resistance (GMR) sensor was applied to address these issues. The GMR sensor is small, easy to replace, and has uniform sensitivity. In this experiment, the GMR sensor was used to measure remote field and defect signal characteristics (in the axial and radial directions) in a ferromagnetic pipe. These characteristics were measured in an effort to investigate standard defects at changing depths within a pipe. The results show that the experiment successfully demonstrated the applicability of the GMR sensor to RFECT signal detection in ferromagnetic pipe.

Electromagnetic wave Shielding Materials for the Wireless Power Transfer Module in Mobile Handset (휴대단말기 무선전력 전송모듈용 전자기파 차폐소재)

  • Bae, Seok;Choi, Don-Chul;Hyun, Soon-Young;Lee, Sang Won
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.2
    • /
    • pp.68-76
    • /
    • 2013
  • Currently, wireless power transmission technology based on magnetic induction was employed in battery charger for smart phone application. The system consists of wireless power transmitter in base station and receiver in smart phone. Size and thickness of receiver was strictly limited in the newest smart phone. In order to achieve high efficiency of a tiny small wireless power receiver module, sub-millimeter thick electromagnetic wave shielding sheet having high permeability and Q was essential component. It was found that magnetic field from transmitter to receiver can be intensified by sufficient shielding cause to minimize leakage magnetic flux by those magnetic properties. This leads to high efficiency of wireless power transmission and protects crucial integrated circuit of main board from electromagnetic noise. The important soft magnetic materials were introduced and summarized for the current small-power wireless power charger and NFC application and mid-power home appliance and high-power automotive application in the near future.

DESIGN OPTIMIZATION OF RADIATION SHIELDING STRUCTURE FOR LEAD SLOWING-DOWN SPECTROMETER SYSTEM

  • KIM, JEONG DONG;AHN, SANGJOON;LEE, YONG DEOK;PARK, CHANG JE
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.380-387
    • /
    • 2015
  • A lead slowing-down spectrometer (LSDS) system is a promising nondestructive assay technique that enables a quantitative measurement of the isotopic contents of major fissile isotopes in spent nuclear fuel and its pyroprocessing counterparts, such as $^{235}U$, $^{239}Pu$, $^{241}Pu$, and, potentially, minor actinides. The LSDS system currently under development at the Korea Atomic Energy Research Institute (Daejeon, Korea) is planned to utilize a high-flux ($>10^{12}n/cm^2{\cdot}s$) neutron source comprised of a high-energy (30 MeV)/high-current (~2 A) electron beam and a heavy metal target, which results in a very intense and complex radiation field for the facility, thus demanding structural shielding to guarantee the safety. Optimization of the structural shielding design was conducted using MCNPX for neutron dose rate evaluation of several representative hypothetical designs. In order to satisfy the construction cost and neutron attenuation capability of the facility, while simultaneously achieving the aimed dose rate limit (< $0.06{\mu}Sv/h$), a few shielding materials [high-density polyethylene (HDPE)eBorax, $B_4C$, and $Li_2CO_3$] were considered for the main neutron absorber layer, which is encapsulated within the double-sided concrete wall. The MCNP simulation indicated that HDPE-Borax is the most efficient among the aforementioned candidate materials, and the combined thickness of the shielding layers should exceed 100 cm to satisfy the dose limit on the outside surface of the shielding wall of the facility when limiting the thickness of the HDPE-Borax intermediate layer to below 5 cm. However, the shielding wall must include the instrumentation and installation holes for the LSDS system. The radiation leakage through the holes was substantially mitigated by adopting a zigzag-shape with concrete covers on both sides. The suggested optimized design of the shielding structure satisfies the dose rate limit and can be used for the construction of a facility in the near future.

A New Concept of Magnetic Cable for Safe Mobile Power Delivery (안전한 전력전달을 위한 새로운 형태의 자기케이블)

  • Lee, Woo-Young;Huh, Jin;Choi, Su-Yong;Rim, Chun-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.542-553
    • /
    • 2011
  • A magnetic cable that can safely deliver high frequency AC electric power in flammable or sensitive workplaces by preventing from arcs and electric shocks is firstly proposed in this paper. Several new magnetic cable structures with magnetic shields, which are composed of such cancel coil, cancel copper plate, and cancel copper pipe, were compactly implemented by considering and analyzing fringe field and thus the parallel leakage flux is drastically reduced. The output power and efficiency of a prototype magnetic cable with 1.5 m length and 5 cm gap were measured as 353.8W and 68%, where the source current and switching frequency were 10 $A_{rms}$ and 20 kHz, respectively. The proposed magnetic cables are fully analyzed and verified by finite-element method (FEM) simulations and experiments. The results are in a good agreement.

Preparation and Oxygen Permeability of $PrBa_{0.9}Sr_{0.1}Co_2O_{5+{\delta}}$ Ceramic Membrane ($PrBa_{0.9}Sr_{0.1}Co_2O_{5+{\delta}}$ 세라믹 분리막의 제조 및 산소투과 특성)

  • Pyo, Dae-Woong;Kim, Jong-Pyo;Son, Su-Hwan;Park, Jung-Hoon
    • Membrane Journal
    • /
    • v.21 no.4
    • /
    • pp.321-328
    • /
    • 2011
  • $PrBa_{0.9}Sr_{0.1}Co_2O_{5+{\delta}}$ oxide was synthesized by soild state reaction method. Dense ceramic membrane was prepared using as-prepared powder by pressing and sintering at $1250^{\circ}C$. XRD result of membrane showed double perovskite structure. Leakage and oxygen permeation test were conducted on the membrane sealed by pyrex ring as a sealing material. Oxygen permeation was measured in the temperature range from 850 to $950^{\circ}C$. The oxygen flux of $PrBa_{0.9}Sr_{0.1}Co_2O_{5+{\delta}}$ membrane was increased with the temperature from 0.15 to $0.32mL/cm^2{\cdot}min$.

Effects of the Multi-Defects on Detecting Signals in Magnetic Flux Leakage System (자기누설탐상시스템에서 밀집된 다수의 결함이 탐상 신호에 미치는 영향)

  • Seo, Kang;Jeong, Hyun-Won;Park, Gwan-Soo;Lee, Min-Ho;Choi, Doo-Hyun;Lee, Seung-Hyun;Um, Chang-Gun;Shin, Pan-Seok;Kim, Chul;Rho, Yong-Woo;Yoo, Hui-Ryong;Cho, Sung-Ho;Kim, Dong-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.70-73
    • /
    • 2005
  • 자기누설탐상시스템은 지하에 매설된 가스관에서 발생되는 부식이나 크랙 또는 기계적 변형을 탐지하기 위한 방법으로 비파괴검사 방법의 하나이다. 가스관은 Nd자석에 의해 착자가 되고, 가스관에 부식이 발생했을 경우 가스관의 단면적이 작아지게 되어 자기누설이 발생하며, 발생된 자기누설을 홀센서로 검출하여 부식의 유무, 크기, 모양 등을 판별하게 된다. 가스관에는 한 개의 독립적인 부식도 있지만, 다수의 부식이 밀집되어 나타나기도 한다. 다수의 부식이 밀집되었을 경우 부식간의 거리에 따라 하나의 부식으로 판정되기도 하며, 그에 따라 부식의 깊이를 판정하는데 있어 정확성이 저감된다. 따라서 본 논문에서는 다수의 부식이 밀집되어 발생할 경우 자기적 영향을 분석하고, 깊이 판정에 있어 정확성을 높이기 위한 연구를 수행하였다. 이를 위해서 실제 결함을 제작하여 실험하고, 해석하여 비교하였으며 밀집된 다수의 부식에 의한 자기적 영향에 대하여 고찰하였다.

  • PDF

Feasibility Study on the Utilization of EMAT Technology for In-line Inspection of Gas Pipeline

  • Cho, Sung-Ho;Yoo, Hui-Ryong;Rho, Yong-Woo;Kim, Hak-Joon;Kim, Dae-Kwang;Song, Sung-Jin;Park, Gwan-Soo
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.36-41
    • /
    • 2011
  • If gas is leaking out of gas pipelines, it could cause a huge explosion. Accordingly, it is important to ensure the integrity of gas pipelines. Traditionally, over the years, gas-operating companies have used the ILI system, which is based on axial magnetic flux leakage (MFL), to inspect the gas pipelines. Relatively, there is a low probability of detection (POD) for the axial defects with the axial MFL-based ILI. To prevent the buried pipeline from corrosion, it requires a protective coating. In addition to the potential damage to the coating by environmental factors and external forces, there could be defects on the damaged coating area. Thus, it is essential that nondestructive evaluation methods for detecting axial defects (axial cracks, axial groove) and damaged coating be developed. In this study, an electromagnetic acoustic transducer (EMAT) sensor was designed and fabricated for detecting axial defects and coating disbondment. In order to validate the performances of the developed EMAT sensor, experiments were performed with specimens from axial cracks, axial grooves, and coating disbondment. The experimental results showed that the developed EMAT sensor could detect not only the axial cracks (minimum 5% depth of wall thickness) and axial grooves (minimum 10% depth of wall thickness), but also the coating disbondment.