• Title/Summary/Keyword: Flux Flow

Search Result 1,680, Processing Time 0.03 seconds

Transient Critical Heat Flux Under Flow Coastdown in a Vertical Annulus With Non-Uniform Heat Flux Distribution

  • Moon, Sang-Ki;Chun, Se-Young;Park, Ki-Yong;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.382-395
    • /
    • 2002
  • An experimental study on transient critical heat flux (CHF) under flow coastdown has been performed for the water flow in a non-uniformly heated vertical annulus under low flow and a wide range of pressure conditions. The objectives of this study are to systematically investigate the effect of the flow transient on the CHF and to compare the transient CHF with steady-state CHF The transient CHF experiments have been performed for three kinds of flow transient modes based on the coastdown data of a nuclear power plant reactor coolant pump. At the same inlet subcooling, system pressure and heat flux, the effect of the initial mass flux on the critical mass flux can be negligible. However, the effect of the initial mass flux on the time-to- CHF becomes large as the heat flux decreases. The critical mass flux has the largest value for slow flow reduction rate. There is a pressure effect on the ratio of the transient CHF data to steady-state CHF data. Except under low system pressure conditions, the flow transient CHF was revealed to be conservative compared with the steady-state CHF data. Bowling CHF correlation and thermal hydraulic system code MARS show promising results for the prediction of CHF occurrence .

Effect of the Flow Rate of Coolant on the Absorption Peformance of a Vertical Absorber (수직 액막형 흡수기의 흡수성능 변화에 미치는 냉각수 유량의 영향)

  • Kim Jung-Kuk;Cho Keum-Nam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.410-417
    • /
    • 2006
  • The present study predicted the effect of the flow rate of coolant on the absorption performance of a vertical falling film type absorber Heat and mass transfer peformances were numerically investigated. The exit temperatures of solution and coolant were decreased as the flow rate of the coolant was increased at the film Reynolds number of 100. The absorption mass flux was increased and then decreased as the distance from the inlet of the absorber was increased. The distance showing the maximum absorption mass flux was ranged from 0.3 to 0.5m. The heat flux and the absorption mass flux were increased and then slowly decreased as the flow rate of the coolant was increased. The maximum values were obtained at the flow rate of coolant of 2.0L/min.

Modeling of a Superconducting Flux Flow Sensor Inductance Radiometer (인덕턴스 복사계 측정을 위해 사용된 초전도 자속 흐름 센서기 모델링)

  • Ko, Seok-Cheol;Kang, Hyeong-Gon;Lim, Sung-Hun;Choi, Myong-Ho;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.19-22
    • /
    • 2003
  • For use in constructing highly sensitive thermal detectors, the present authors have been studying the preparation of Superconducting Flux Flow Sensor(SFFS). In this research, SFFS with five channel ($5{\mu}m$/1channel) has been fabricated based on the flux flow using high temperature superconducting thin films by the ICP etching technique. We have designed a bolometer based on the temperature dependence of the kinetic inductance of a superconducting flux flow thin film. In this paper examines the fabrications and flux flow resistance and thermometer responses of the highly sensitive sensor constructed of a thin YBCO film. It is also suggested that they will be applicable to a new type of flux flow sensor.

  • PDF

Modeling of flux enhancement in presence of concentration polarization by pressure pulsation during laminar cross flow ultrafiltration

  • Kumar, Kamal;De, Sirshendu
    • Membrane and Water Treatment
    • /
    • v.1 no.4
    • /
    • pp.253-271
    • /
    • 2010
  • A theoretical study for the flux enhancement by pulsation of transmembrane pressure is presented for osmotic pressure controlled ultrafiltration under laminar flow regime. The transient velocity profile is solved analytically using Green's function method. Time dependent convective diffusive equation is solved to quantify the membrane surface concentration and the permeate flux, numerically. The effects of the amplitude and frequency of pulsation on flux, surface concentration and observed retention are studied.

Separation of Antibiotics-Producing Mycelia by Cross-Flow Filteration (Cross-Flow Filtration에 의한 항생물질 생산 균사체의 분리)

  • 정상철;윤종원
    • KSBB Journal
    • /
    • v.4 no.2
    • /
    • pp.177-184
    • /
    • 1989
  • In separating mycelia from antibiotic fermentation broths, high permeate flux was obtained by cross-flow filtration using modified regenerated cellulose membrane. The flux was increased most effectively by increasing the flow rate. There existed a critical mycelium density (about 20% PMV) at which the highest flux was observed. In a batchwise concentration of the fermentation broth, the system suffered from a severe fouling problem, which was relieved drastically by applying diafiltration technique, although it increased the permeate volume. A combined concentration/diafiltration process was ideal in keeping relatively high flux together with a high product recovery yield. The best result was obtained by starting diafiltration after concentrating the broth to 20% PMV. By doing so, a 98% product recovery yield was achieved in the shortest time while keeping the permeate volume at a minimum level.

  • PDF

Effect of $N_2$ flow rate on properties of GaN thin films ($N_2$ flow rate가 GaN 박막의 특성에 미치는 영향)

  • 허광수;박민철;명재민
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.66-69
    • /
    • 2001
  • Effect of $N_2$ flow rate on properties of GaN thin films grown by plasma-enhanced molecular beam epitaxy(PEMBE) was discussed to optimize the quality of thin films. It was found that at low $N_2$ flow rate indicating high III/V flux ratio, the growth rate of GaN thin films was controlled by $N_2$ flux, and at high $N_2$ flow rate the growth rate was not controlled by $N_2$ flux any longer. It was also found that III/V flux ratio affected film quality. The film grown at higher $N_2$ flow rate showed low background carrier concentration, higher carrier mobility, and narrow FWHM in band-edge emission of low temperature PL. It is thought that the film in more Ga flux region was grown by 2-dimensional layer-by-layer growth mode, and the film in more nitrogen region was grown by 3-D island growth mode. All samples exhibited a good crystallinity.

  • PDF

Experimental study on the transfer in pulse tube (맥동관 내부의 열전달에 관한 실험적 연구)

  • 김민규;남관우;정상권;장호일;정은수
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.1
    • /
    • pp.45-50
    • /
    • 2000
  • The present study has been conducted to observe the heat transfer under pulsating pressure and oscillating flow. The experimental apparatus was fabricated to measure the gas temperature, the wall temperature. the pressure and the instantaneous heat flux inside the pulse tube. The measured gas temperature and heat flux must be calibarated to compensate their finite time constant in the oscillating flow conditious. The experiment was performed from 1 Hz to 5 Hz. The phase difference between the instantaneous heat flux and the gas-wall temperature difference was clearly observed. The experimental heat fluxes were compared to the theroretical correlations such as Complex Nusselt Number Model(CNNM) and Variable Coefficient Model(CVM). The heat flux predisted by CNNM was always greater than that of VCM. The experiment confirmed the valisity of the VCM for the instantaneous heat flux under the pulsating pressure and oscillating flow in the warm end of the pulse tube.

  • PDF

Experimental Study of Natural Convection from a Slightly Inclined Cylinder with Uniform Heat Flux Immersed in Cold Pure Water (저온의 순수물속에 잠겨있는 약간 경사진 균일 열유속 원기등에 의한 자연대류의 실험적 연구)

  • 유갑종;추홍록;장우석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.7
    • /
    • pp.1799-1807
    • /
    • 1994
  • Natural convection from a slightly inclined circular cylinders immersed in quiescent cold pure water was studied experimentally. The experiment was carried out for circular cylinders with uniform heat flux ranging from $100W/m^{2} to 800 W/m^{2}$ and inclined angle ranging from horizontal $({\phi}=0^{\circ}) to 15^{\circ}$. The flow fields around cylinder were visualized and heat transfer characteristics investigated by measuring the surface temperatures for each case. As the results, it is shown that flow patterns are changed consecutively through the sequence of steady state downflow, unsteady state flow and steady state upflow with increasing heat flux. At the same inclined angle, as heat flux increases, the average Nusselt number decreases and then increases. At the same heat flux, as inclined angle increases, the average Nusselt number decreases.

Operational Characteristics of Superconducting Amplifier using Vortex Flux Flow

  • Lim, Sung-Hun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.260-264
    • /
    • 2008
  • The operational characteristics of superconducting amplifier using vortex flux flow were analyzed from an equivalent circuit in which its current-voltage characteristics for the vortex motion in YBCO microbridge were reflected. For the analysis of operation as an amplifier, dc bias operational point for the superconducting amplifier is determined and then ac operational characteristics for the designed superconducting amplifier were investigated. The variation of transresistance, which describes the operational characteristics of superconducting amplifier, was estimated with respect to conditions of dc bias. The current and the voltage gains, which can be derived from the circuit for small signal analysis, were calculated at each operational point and compared with the results obtained from the numerical analysis for the small signal circuit. From our paper, the characteristics of amplification for superconducting flux flow transistor (SFFT) could be confirmed. The development of the superconducting amplifier applicable to various devices is expected.

Experimental Study on Minimum Heat Flux Point of Liquid Film Flow (액막류의 MHF 점에 관한 실험적 연구)

  • Kim, Yeung-Chan
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.208-213
    • /
    • 2001
  • The minimum heat flux conditions are experimentally investigated for the subcooled liquid film flow on the horizontal plate. The experimental results show that the minimum heat flux point temperature becomes higher with the increase of the velocity and the subcooling of the liquid film flow. However, the effect of distance from the leading edge of the heat transfer plate on the minimum heat flux is almost negligible. Also, the experimental results show that the propagation velocity of wetting front increase with increasing the velocity and the subcooling of the liquid film flow.

  • PDF