• Title/Summary/Keyword: Flush Type

Search Result 56, Processing Time 0.027 seconds

A study on dynamic characteristics in extension tube and correction of pressure distortion for a S/P type pressure transducer (스파크 플러그형 압력센서에서 연결관로의 동적특성과 압력왜곡의 보상에 관한 연구)

  • 한승국;김승수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.3
    • /
    • pp.32-42
    • /
    • 1991
  • In SI engine research the pressure data in cylinder is the most important fundamental ones leading to engine efficiencies and performances. It is, therefore, necessary to obtain accurate pressure data and yet it is often impossible to install a reliable data producing, flush-mounted type pressure transducer in a cylinder of small and medium size multicylinder SI engines. When flush mounting the transducer is not possible, the spark-plug type pressure transducer is commonly used as an alternative. In this case, the transmission tube of spark-plug type pressure transducer introduces distortions in the pressure signal. Efforts were made to understand the dynamic characteristics of spark-plug pressure transducer by shock tube tests and real engine experiments. In engine experiment the cylinder pressure data were simultaneously obtained by both flush mounted and spark-plug type pressure transducers of certain transmission tube geometry. Those pressure data collected by spark-plug type pressure transducer were tested for correction to flush mounted ones by the application of transfer function. As a result of the calibration the IMEP difference between F/M data and improved S/P data was shown to be corrected about 75-98% from the original ones.

  • PDF

The evaluation of the simultaneous flow rate for sizing the water supply piping in the office building (사무소 건물의 급수배관경 산정을 위한 동시사용유량에 관한 연구)

  • 이용화
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.511-517
    • /
    • 1999
  • Determining the simultaneous flow rate in any particular section of piping is the important step in order to determine the size of water supply piping. Now we are using the diversity curve of common water closet in order to determine the simultaneous flow rate of water supply piping, but there is a difference between a determined flow rate of general water closet and that of water closet for water saving. This study aims to find out the fixture unit of a flush valve type water closet for water saving in office building, and to determine the correlation between the fixture units and peak flow rates on the basis of the probability theory. A flush valve type water closet for water saving that have a 7.5 second duration of flush operation with an average design flow rate 72 $\ell$/fin was considered. Simulation results indicate that the number 5 is shown to be reasonable to the fixture unit of water closet for water saving. And the design can be undersized considerably with the revised diversity curves using modified fixture unit.

  • PDF

Skin Condition Analysis of Facial Image using Smart Device: Based on Acne, Pigmentation, Flush and Blemish

  • Park, Ki-Hong;Kim, Yoon-Ho
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.8 no.2
    • /
    • pp.47-58
    • /
    • 2018
  • In this paper, we propose a method for skin condition analysis using a camera module embedded in a smartphone without a separate skin diagnosis device. The type of skin disease detected in facial image taken by smartphone is acne, pigmentation, blemish and flush. Face features and regions were detected using Haar features, and skin regions were detected using YCbCr and HSV color models. Acne and flush were extracted by setting the range of a component image hue, and pigmentation was calculated by calculating the factor between the minimum and maximum value of the corresponding skin pixel in the component image R. Blemish was detected on the basis of adaptive thresholds in gray scale level images. As a result of the experiment, the proposed skin condition analysis showed that skin diseases of acne, pigmentation, blemish and flush were effectively detected.

Structural Performance of H-shaped Column-Rafter Connection in the P.E.B Systematic Steel Frames (P.E.B 시스템 강골조에서 H형강 기둥 - Rafter 접합부의 구조성능)

  • Kim, Jong Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.347-356
    • /
    • 2005
  • Recently, pre-engineering building (P.E.B.) systematic frames are increasingly being used in steel factory buildings, but almost of the related techniques are dependent on the engineering program (e.g, MBS, LTI), which is usually imported from other countries. These are designed under the AISC-ASD because at present there is no Korean design code for P.E.B. frames. Also, there are few studies onbehaviour and we need to develop the element techniques by using H-shaped components.In particular, there is a tendency towards overestimated design because column-rafter connections have been designed with extended end plate type joint, which is treated asrigid joint,so structural examinations are needed. Therefore, this study represents a basic step in ascertaining the application of P.E.B. systematic frames by using H-shaped column-rafter connectionwith flush type end plate. Its structural performance is compared with that of existing extended type joint using a structural performance test. The structural behaviour of specimen was understood qualitatively and the possibility of application (e.g, design aid charts) of semi-connection (flush type) with H-shaped column-rafter was determined.

A Case Report of Hot Flush-Type Rosacea Improved by Baekho-tang (백호탕(白虎湯)으로 호전을 보인 안면홍조형 주사피부염 치험 1례)

  • Lee, Ju-Hyun;Park, Min-Cheol;Hong, Ji-Eun;Park, Ji-Won;Jo, Eun-Heui
    • The Journal of Korean Medicine
    • /
    • v.41 no.3
    • /
    • pp.173-179
    • /
    • 2020
  • Objectives: This study aims to report a case of hot flush-type rosacea improved by oral administration of Baekho-tang. Methods : The patient visited our clinic due to hot flash symptom on April 16, 2020. Based on the symptoms of hating heat, bloating, sweating, and thirst, traditional medicine Baekho-tang was prescribed. Results : After 5 days of taking Baekho-tang, the symptom score of hot flush improved significantly from 8 to 3. About a week later, most of the symptoms, including hot flush, edema, and burning sensation almost disappeared. After treatment, the follow-up process was conducted for about a month, and it was confirmed that the flushing of the face did not recur and remained improved. Conclusions : After a week of Baekho-tang administration, hot flush, burning sensation, edema and other symptoms associated with rosacea improved overall.

First flush modeling of the radial type surface runoff and a placement strategy for stormwater inlets to improve the effectiveness of the first flush treatment in a small impervious catchment (방사형 강우 유출의 초기세척 모의 및 소규모 불투수 배수구역에서의 초기우수 처리효과 상승을 위한 집수시설 배치 방안)

  • Kang, Joo-Hyon;Lee, Dong Hoon;Kim, Jin Hwi
    • Journal of Wetlands Research
    • /
    • v.19 no.4
    • /
    • pp.375-382
    • /
    • 2017
  • In this study, general characteristics of dynamic behavior of stormwater runoff from a small impervious catchment was investigated from a series of simulations for a radial type surface runoff. Based on the simulation results, a better placement strategy for stormwater inlets to improve performance of a structural best management practice (BMP) was suggested. The degree of pollutant first flush from an ideal radial type impervious catchment was simulated using a 1-D diffusion wave equation coupled with a pollutant transport equation. The results showed that the first flush of the chemical oxygen demand was the strongest when the catchment length ranged 30-50m at a bed slope of 0.02. This result suggested that a required degree of the first flush can be intentionally obtained by just changing the locations and numbers of stormwater inlets, and thereby adjusting the catchment length. Particularly, the overall performance of a structural BMP in reducing pollutant load can be improved by placing the stormwater inlets at locations for obtaining a required first flush strength.

Evaluation of Structural Behavior of Tapered Member with Snug-tightened Flush End-plate Connection (밀착조임 볼트체결방법에 따른 엔드플레이트 접합부의 구조성능평가)

  • Chung, Kyung-Soo;Kim, Woo-Sik;Park, Man-Woo;Do, Byung-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.2
    • /
    • pp.121-128
    • /
    • 2010
  • The current trends in steel construction involve the use of tapered sections to minimize the use of excess materials to the extent possible, by choosing cross-sections that are as economical as possible abandoning the classical approach of using prismatic members. In addition, snug-tightened connections, especially the end-plate type, have the advantage of fetching less construction costs and shorter assembly times as opposed to fully tightened joints. Although they have many merits, however, snug-tightened bolted end plates are extremely complex in their structural behavior. In this study, an experimental investigation of the snug-tightened flush end-plate connections of tapered beams were conducted. The primary test parameters were the torque for the clamping bolt, the loading pattern, the bolt type and the connection failure type. Using initial stiffness and load-carrying capacity as proposed by Silva et al. and AISC (2003), the moment-rotation curve of a linearly tapered member with a snug-tightened flush end-plate connection was predicted. Moreover, numerical and experimental data for moment-rotation curves were compared.

An Experimental Study on the Droplet Size Distribution of Sprinkler Spray for Residential Building (주거용 스프링클러 분무의 액적크기 분포에 관한 실험적 연구)

  • Kim, Sung Chan;Kim, Jung Yong
    • Journal of ILASS-Korea
    • /
    • v.20 no.3
    • /
    • pp.175-180
    • /
    • 2015
  • A series of sprinkler discharging tests was conducted to measure the droplet size and its distribution of residential fire sprinkler heads. Droplet sizes in sprinkler spray were measured using a laser diffraction method for the flush, circular and pendent type sprinkler head. In this study, the $D_{v,50}$ of the flush type sprinkler heads were ranged between $530{\sim}1040{\mu}m$ and those of circular and pendent type were $988{\mu}m$ and $916{\mu}m$, respectively. The measured cumulative volume distributions were followed by a combination of the log-normal and Rosin-Rammler distribution which is widely used in the computational fire analysis and the parameters of distribution function were obtained from the best fit line through the measured data.

A study on TDC crank angle determination by motoring pressure measurement (모터링 압력측정을 통한 상사점 결정방법에 관한 연구)

  • 한정옥;이영주;김승수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.39-47
    • /
    • 1988
  • A disk photo sensor system was constructed and installed on engine for the crank angle measurement. Statically measured TDC crank angle data were compared with those obtained from engine motoring. Two groups of cylinder pressure data were compared each other, one measured by pressure transducer mounted flush on the combustion chamber and the other obtained with the help of spark plug type adaptor. A simple analysis on the gas flow in the spark plug type pressure transducer displayed reasonably good agreement with those from engine motoring tests. In various firing tests, the IMERs obtained from the spark plug type pressure transducer turned out to be higher than those from the flush mounted one at low engine speed while those two were nearly the same at high engine speed. As the engine load decreased the relative difference in IMEP measurement between the two types tended to be enlarged.

  • PDF

Runoff Characteristics of Stormwater in Small City Urban Area (국내 중소 도시지역 강우유출수의 유출특성)

  • Lee, Hong-Shin;Lee, Seung-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.3
    • /
    • pp.193-202
    • /
    • 2009
  • This study was conducted to identify the magnitude of first flush in small city urban area and to provide the basic information on the criteria of stormwater runoff management. Monitoring site was surrounded by residential area in Gumi city near to national industrial complex and the monitoring period was three months. Total watershed area was 24.9 ha, where 80% of the area is impervious (asphalt of pavement type). Periodic monitoring of conventional water quality parameters were conducted with six times of rainfall period. Event mean and site mean concentrations for all the parameters were calculated based on the analytical results. Particle size distribution was 9.82 ${\mu}m$ for $D_{0.1}$, 38.99 ${\mu}m$ for $D_{0.5}$ and 159.61 ${\mu}m$ for $D_{0.9}$ respectively. First flush phenomenon was detected highly in particulate solids than dissolved ones. The first flush criteria results by mass first flush contained between 44.4% to 58.5% pollutant mass during the first 30% of runoff volume. Mass first flush ratio and particle size distribution obtained in this study are expected to provide the basic information for the design and operation of non-point source treatment facility.