• Title/Summary/Keyword: Fluoroscope

Search Result 26, Processing Time 0.022 seconds

The Radiation Exposure of Radiographer Related to the Location in C-arm Fluoroscopy-guided Pain Interventions

  • Chang, Young Jae;Kim, Ah Na;Oh, In Su;Woo, Nam Sik;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.27 no.2
    • /
    • pp.162-167
    • /
    • 2014
  • Background: Although a physician may be the nearest to the radiation source during C-arm fluoroscope-guided interventions, the radiographer is also near the fluoroscope. We prospectively investigated the radiation exposure of radiographers relative to their location. Methods: The effective dose (ED) was measured with a digital dosimeter on the radiographers' left chest and the side of the table. We observed the location of the radiographers in each procedure related to the mobile support structure of the fluoroscope (Groups A, M and P). Data about age, height, weight, sex, exposure time, radiation absorbed dose (RAD), and the ED at the radiographer's chest and the side of the table was collected. Results: There were 51 cases for Group A, 116 cases for Group M and 144 cases for Group P. No significant differences were noted in the demographic data such as age, height, weight, and male to female ratio, and exposure time, RAD and ED at the side of the table. Group P had the lowest ED ($0.5{\pm}0.8{\mu}Sv$) of all the groups (Group A, $1.6{\pm}2.3{\mu}Sv$; Group M, $1.3{\pm}1.9{\mu}Sv$; P < 0.001). The ED ratio (ED on the radiographer's chest/ED at the side of the table) of Group A was the highest, and the ED radio of Group P was the lowest of all the groups (Group A, $12.2{\pm}21.5%$; Group M, $5.7{\pm}6.5%$; Group P, $2.5{\pm}6.7%$; P < 0.001). Conclusions: Radiographers can easily reduce their radiation exposure by changing their position. Two steps behind the mobile support structure can effectively decrease the exposure of radiographers by about 80%.

Fluoroscopy Guided Facial Nerve Block in the Treatment of Facial Spasm (안면 경련 환자에서 진단투시기를 이용한 안면 신경 차단)

  • Lim, Hyun-Kyung;Kwak, No-Kir;Lee, Young-Bok;Yoon, Kyung-Bong
    • The Korean Journal of Pain
    • /
    • v.8 no.1
    • /
    • pp.82-85
    • /
    • 1995
  • Hemifacial spasm is a distressing condition characterized clinically by paroxysmal and an involuntary movement in muscles innervated by the facial nerve on one side of the face. Blockade of the facial nerve can be performed percutaneously, without any serious complications. There are certain clinical problems associated with the conventional procedure, such as severe pain and technical difficulties to find facial nerve. This report describes a fluoroscope guided facial nerve block. This new technique reduced the difficulties in identifying the facial nerve and decreased the suffering associated with the conventional way of facial nerve block.

  • PDF

REMOVAL OF A PIERCING BAR IN THE MOUTH FLOOR BY FLUOROSCOPY: REPORT OF A CASE (형광 투시법을 이용한 구강저에서의 피어싱 바의 제거: 증례보고)

  • Kim, Jae-Won;Jang, Ji-Young;Jang, Heon-Soo;Cha, Du-Won;Baek, Sang-Heum
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.2
    • /
    • pp.196-199
    • /
    • 2008
  • The piercing is increasing in western culture, and has also become gradually popular among Korean teenagers recently However, the accident hap-pens sometimes such as loss of a bar into the tongue or mouth floor during the procedure. Because of the rare cases, few treatment of choices can be made when a bar is lost inside the mouth floor. In this case, the bar was removed under fluoroscope, without giving significant damage to the adjacent structure. 18 years old female patient visited the emergency room in our hospital. She attempted to pierce her tongue herself and could not find the bar which was lost in the mouth floor. The radiographs revealed that the needle was somewhere inside the mouth floor, but if incision were to be made it would be too deep to find the bar. The bar was removed through fluoroscope easily. Primary closure was done by 5-0 Vicryl and stitch-off was done 1 week later. The patient didn't have any speech problems and complications.

The Study on Scattered Ray by C-arm in Operation Room (수술실 내 C-arm 장치의 산란선 분포에 대한 연구)

  • Park, Seung-Hyun;Park, Joo-Mi;Kim, Hyun-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.21-26
    • /
    • 2011
  • A radiation imaging system used in a surgery room is mainly using C-arm which is purposed to fluoroscope. C-arm is often use to watch an operation's accuracy and progress, but not only being bombed to this first beam but also affected to this scattered beam, so now we are look for the way to reduce bombed amount of doctor, nurses and radiological technologists. We measured the exposure dose in $0^{\circ}$ spot according to the distance to find out frequency distribution of scattered ray in an operation room and found the spot which has the same exposure dose from $30^{\circ}$ distance of all directions and wrote isodose curve. We analyzed the data and found out the sudden reduction of scattered ray according to the long direction also found out that scattered ray was not related to the directions. Operators must recognize the reduction of exposure dose. Because reducing scattered ray from all directions in an operation room is really difficult. So every operators must use shelters to reduce the exposure dose and notice the safety.

  • PDF

Development of a Fall Detection System Using Fish-eye Lens Camera (어안 렌즈 카메라 영상을 이용한 기절동작 인식)

  • So, In-Mi;Han, Dae-Kyung;Kang, Sun-Kyung;Kim, Young-Un;Jong, Sung-tae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.4
    • /
    • pp.97-103
    • /
    • 2008
  • This study is to present a fainting motion recognizing method by using fish-eye lens images to sense emergency situations. The camera with fish-eye lens located at the center of the ceiling of the living room sends images, and then the foreground pixels are extracted by means of the adaptive background modeling method based on the Gaussian complex model, which is followed by tracing of outer points in the foreground pixel area and the elliptical mapping. During the elliptical tracing, the fish-eye lens images are converted to fluoroscope images. the size and location changes, and moving speed information are extracted to judge whether the movement, pause, and motion are similar to fainting motion. The results show that compared to using fish-eye lens image, extraction of the size and location changes. and moving speed by means of the conversed fluoroscope images has good recognition rates.

  • PDF

Percutaneous Radiofrequency Thoracic Sympathectomy (경피적 고주파열응고법에 의한 흉부교감신경절차단)

  • Yoon, Duck-Mi;Ishizaki, Keiji;Fujita, Tatsushi
    • The Korean Journal of Pain
    • /
    • v.8 no.1
    • /
    • pp.74-77
    • /
    • 1995
  • Upper thoracic sympathectomy is valuable for patients with vascular occlusive disease and other painful upper extremity diseases. We performed 10 upper thoracic sympahthectomies by percutaneous radiofrequency destruction in painful disorder of upper extremity. Patients were supine and the needle was inserted paratracheally under C-arm fluoroscope. The second and third thoracic sympathetic gangla were destructed by radiofrequency lesion generator. Each lesion was made with a tip temperature of $90^{\circ}C$, 90 seconds. Good to excellent results were achieved in all patients without any adverse effect. Seven patients revealed complete sympatholytic effect and other three patients were showen signs of partial sympathetic block. Two patients were persisted sympatholytic effect for 18month in and other 5 patients were persisted sympatholytic effect at present (follow up period: mean 5.8 mon). Percutaneous radiofrequency upper thoracic sympathectomy with anterior paratracheal approach is an effective and a safe method.

  • PDF

Fine Needle Aspiration Cytology of Mediastinal Goiter (종격동 갑상선종 1예의 세침흡인생검 소견)

  • Kim, Yee-Jeong;Lee, Kwang-Gil
    • The Korean Journal of Cytopathology
    • /
    • v.2 no.2
    • /
    • pp.148-152
    • /
    • 1991
  • A mediastinal mass was aspirated by fluoroscope-guided fine needle aspiration biopsy in a 47 years old female patient. The first aspiration smears were not diagnostic, because of hemorrhagic background and cell paucity. On the second aspiration, the smears were composed of some clusters of benign epithelial cells in hemorrhagic back-ground. Cells were arranged in mostly solid sheets and tended to form glandular lumina in part. Their nuclei were round and vesicular. Nucleoli were not prominent. These findings were suggestive of benign glandular tissue, which was finally confirmed as mediastinal thyroid gland by open thoracotomy specimen.

  • PDF

A FLUOROSCOPIC STUDY ON THE STABILITY OF SKIN REFERENCE POINTS DURING JAW OPENING AND CLOSING MOVEMENT (방사선 투시를 이용한 개폐구 운동에 따른 수직 고경 계측점의 안정성에 관한 연구)

  • Ahn, Hyung-Jun;Kim, Chang-Whe;Kim, Yung-Soo;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.516-530
    • /
    • 1999
  • The current clinical technique for occlusal vertical dimension recording is based on marking the skin reference points on the patient's face and measuring between these points using caliper-like device. And it is difficult to achieve reliable measurements by this technique because of movable soft tissue. The purpose of this study is to reveal the stability of skin reference points by comparing the relative movement between extra-oral skin reference points and intra-oral reference points using X-ray fluoroscope. 10 test subjects were divided into 2 groups : Group I (natural dentition) and Group II (denture-wearer whose vertical dimension was lost) and Group III consists of identical test subjects to Group II with their upper denture removed and record base inserted. Attaching the 3 mm diameter steel ball to nose tip, lower lip, chin and to existing denture (or record base), fluoroscopic examination and recording were taken during 2 jaw opening and closing movements. After subsequent digitization using personal computer, 1219 still pictures with 0.1 second interval were made. Using the 2 dimensional graphic software, measurements between reference points were executed. Dividing the entire jaw movement into 3 ranges (total, 1st half opening, 2nd half opening), rate of movement and relative movement between extra-oral and intra-oral reference points were calculated and statistically analyzed. The results of this study are as follows. 1 Within the same experimental group, no statistical difference was found in the stability of skin reference between lower lip point and chin point during total range of jaw opening and closing movement (p>.05) 2. In the first half range of jaw opening, statistical difference was found between Group I (natural dentition) and Group II (denture wearer) (p<.05) Group I has greater skin reference stability than Group II. 3. In the first half range of jaw opening, statistical difference was found between Group I and Group III (record base wearer) (p<.05). Group I has greater skin reference stability than Group III. 4. In the first half range of jaw opening, no statistical difference was found in the stability of skin reference between Group II and Group III (p>.05). 5. In the second half range of jaw opening, no statistical difference was found in the stability of skin reference between any experimental groups (p>.05). 6. In patients with their occlusal vertical dimension lost, employing other measuring references rather than skin is recommended because of low stability.

  • PDF

A Randomized Controlled Trial about the Levels of Radiation Exposure Depends on the Use of Collimation C-arm Fluoroscopic-guided Medial Branch Block

  • Baek, Seung Woo;Ryu, Jae Sung;Jung, Cheol Hee;Lee, Joo Han;Kwon, Won Kyoung;Woo, Nam Sik;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.26 no.2
    • /
    • pp.148-153
    • /
    • 2013
  • Background: C-arm fluoroscope has been widely used to promote more effective pain management; however, unwanted radiation exposure for operators is inevitable. We prospectively investigated the differences in radiation exposure related to collimation in Medial Branch Block (MBB). Methods: This study was a randomized controlled trial of 62 MBBs at L3, 4 and 5. After the patient was laid in the prone position on the operating table, MBB was conducted and only AP projections of the fluoroscope were used. Based on a concealed random number table, MBB was performed with (collimation group) and without (control group) collimation. The data on the patient's age, height, gender, laterality (right/left), radiation absorbed dose (RAD), exposure time, distance from the center of the field to the operator, and effective dose (ED) at the side of the table and at the operator's chest were collected. The brightness of the fluoroscopic image was evaluated with histogram in Photoshop. Results: There were no significant differences in age, height, weight, male to female ratio, laterality, time, distance and brightness of fluoroscopic image. The area of the fluoroscopic image with collimation was 67% of the conventional image. The RAD ($29.9{\pm}13.0$, P = 0.001) and the ED at the left chest of the operators ($0.53{\pm}0.71$, P = 0.042) and beside the table ($5.69{\pm}4.6$, P = 0.025) in collimation group were lower than that of the control group ($44.6{\pm}19.0$, $0.97{\pm}0.92$, and $9.53{\pm}8.16$), resepectively. Conclusions: Collimation reduced radiation exposure and maintained the image quality. Therefore, the proper use of collimation will be beneficial to both patients and operators.