References
- Fink GE. Radiation safety in fluoroscopy for neuraxial injections. AANA J 2009; 77: 265-269.
- Singer G. Occupational radiation exposure to the surgeon. J Am Acad Orthop Surg 2005; 13: 69-76. https://doi.org/10.5435/00124635-200501000-00009
- Miller DL, Vano E, Bartal G, Balter S, Dixon R, Padovani R, et al. Occupational radiation protection in interventional radiology: a joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology. J Vasc Interv Radiol 2010; 21: 607-615. https://doi.org/10.1016/j.jvir.2010.01.007
- Le Heron J, Padovani R, Smith I, Czarwinski R. Radiation protection of medical staff. Eur J Radiol 2010; 76: 20-23. https://doi.org/10.1016/j.ejrad.2010.06.034
- Killewich LA, Singleton TA. Governmental regulations and radiation exposure. J Vasc Surg 2011; 53: 44S-46S.
- Park PE, Park JM, Kang JE, Cho JH, Cho SJ, Kim JH, et al. Radiation safety and education in the applicants of the final test for the expert of pain medicine. Korean J Pain 2012; 25: 16-21. https://doi.org/10.3344/kjp.2012.25.1.16
- Botwin KP, Freeman ED, Gruber RD, Torres-Rames FM, Bouchtas CG, Sanelli JT, et al. Radiation exposure to the physician performing fluoroscopically guided caudal epidural steroid injections. Pain Physician 2001; 4: 343-348.
- Jeong WK. Radiation exposure and its reduction in the fluoroscopic examination and fluoroscopy-guided interventional radiology. J Korean Med Assoc 2011; 54: 1269-1276. https://doi.org/10.5124/jkma.2011.54.12.1269
- Poletti JL, McLean D. The effect of source to image-receptor distance on effective dose for some common X-ray projections. Br J Radiol 2005; 78: 810-815. https://doi.org/10.1259/bjr/74823655
- Cho JH, Kim JY, Kang JE, Park PE, Kim JH, Lim JA, et al. A study to compare the radiation absorbed dose of the C-arm fluoroscopic modes. Korean J Pain 2011; 24: 199-204. https://doi.org/10.3344/kjp.2011.24.4.199
- Powys R, Robinson J, Kench PL, Ryan J, Brennan PC. Strict X-ray beam collimation for facial bones examination can increase lens exposure. Br J Radiol 2012; 85: e497-e505. https://doi.org/10.1259/bjr/19989149
- Rathmell JP. Radiation safety. In: Atlas of image-guided intervention in regional anesthesia and pain medicine. Edited by Rathmell JP. Philadelphia, Lippincott Williams & Wilkins. 2006, pp 8-15.
- Walters TE, Kistler PM, Morton JB, Sparks PB, Halloran K, Kalman JM. Impact of collimation on radiation exposure during interventional electrophysiology. Europace 2012; 14: 1670-1673. https://doi.org/10.1093/europace/eus095
Cited by
- Effect of Collimation on Radiation Exposure and Image Quality vol.26, pp.3, 2013, https://doi.org/10.3344/kjp.2013.26.3.307
- Radiation Safety for Pain Physicians: Technique or Equipment vol.27, pp.2, 2014, https://doi.org/10.3344/kjp.2014.27.2.101
- How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions? vol.27, pp.2, 2014, https://doi.org/10.3344/kjp.2014.27.2.145
- The Radiation Exposure of Radiographer Related to the Location in C-arm Fluoroscopy-guided Pain Interventions vol.27, pp.2, 2014, https://doi.org/10.3344/kjp.2014.27.2.162
- The radiation safety education and the pain physicians' efforts to reduce radiation exposure vol.30, pp.2, 2017, https://doi.org/10.3344/kjp.2017.30.2.104
- Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management vol.31, pp.4, 2018, https://doi.org/10.3344/kjp.2018.31.4.244
- AUTOMATIC C-ARM REPOSITIONING USING A TWO-BAR LINK SYSTEM FOR REDUCING RADIATION EXPOSURE vol.15, pp.6, 2015, https://doi.org/10.1142/s0219519415400540
- Radiation exposure and protection for eyes in pain management vol.12, pp.4, 2013, https://doi.org/10.17085/apm.2017.12.4.297
- Evaluation of protective equipment for the reduction of radiation exposure to physicians performing fluoroscopically guided lumbar transforaminal epidural steroid injections : A randomized controlled vol.99, pp.31, 2020, https://doi.org/10.1097/md.0000000000021424