• Title/Summary/Keyword: Fluoride-Ion

Search Result 222, Processing Time 0.024 seconds

An Assessment of Post-Injection Transmission Measurement for Attenuation Correction With Rotating Pin Sources in Positron Emission Tomography (양전자방출단층촬영(PET)에서 회전 핀선원과 투과 및 방출 동시 영상 방법을 이용한 감쇠보정 방법 특성에 관한 고찰)

  • Lee, J.R.;Choi, Y.;Lee, K.H.;Kim, S.E.;Chi, D.Y.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.533-540
    • /
    • 1995
  • Attenuation correction is important in producing quantitative positron emission tomography (PET) images. Conventionally, photon attenuation effects are corrected using transmission measurements performed before tracer administration. The pre-injection transmission measurement approach may require a time delay between transmission and emission scans for the tracer studies requiring a long uptake period, about 45 minutes for F-18 deoxyglucose study. The time delay will limit patient throughput and increase the likelihood of patient motion. A technique lot performing simultaneous transmission and emission scans (T+E method) after the tracer injection has been validated. The T+E method substracts the emission counts contaminating the transmission measurements to produce accurate attenuation correction coefficients. This method has been evaluated in experiments using a cylindrical phantom filled with background water (5750 cc) containing $0.4{\mu}Ci/cc$ of F-18 fluoride ion and one insert cylinder (276 cc) containing $4.3{\mu}Ci/cc$. GE $Advance^{TM}$ PET scanner and Ge-68 rotating pin sources for transmission scanning were used for this investigation. Post-injection transmission scan and emission scan were peformed alternatively over time. The error in emission images corrected using post-infection transmission scan to emission images corrected transmission scan was 2.6% at the concentration of $1.0{\mu}Ci/cc$. No obvious differences in image quality and noise were apparent between the two images. The attenuation correction can be accomplished with post-injection transmission measurement using rotating pin sources and this method can significantly shorten the time between transmission and omission scans and thereby reduce the likelihood of patient motion and increase scanning throughput in PET.

  • PDF

Soluble Polyimide Binder for Silicon Electrodes in Lithium Secondary Batteries (리튬이차전지 실리콘 전극용 용해성 폴리이미드 바인더)

  • Song, Danoh;Lee, Seung Hyun;Kim, Kyuman;Ryou, Myung-Hyun;Park, Won Ho;Lee, Yong Min
    • Applied Chemistry for Engineering
    • /
    • v.26 no.6
    • /
    • pp.674-680
    • /
    • 2015
  • A solvent-soluble polyimide (PI) polymeric binder was synthesized by a two-step reaction for silicon (Si) anodes for lithium-ion batteries. Polyamic acid was first prepared through ring opening between two monomers, bicyclo[2,2,2]oct-7-ene-2,3,5,6-tetracarboxylic dianhydride (BCDA) and 4,4-oxydianiline (ODA), followed by condensation reaction. Using the synthesized PI polymeric binder (molecular weight = ~10,945), the coating slurry was then prepared and Si anode was fabricated. For the control system, Si anode based on polyvinylidene fluoride (PVDF, molecular weight = ~350,000) having the same constituent ratio was prepared. During precycling, PI polymeric binder revealed much improved discharge capacity ($2,167mAh\;g^{-1}$) compared to that of using PVDF polymeric binder ($1,740mAh\;g^{-1}$), while the Coulombic efficiency of two systems were similar. PI polymeric binder improved the cycle retention ability during cycles compared to that of using PVDF, which is attributed to an improved adhesion property inside Si anode diminishing the dimensional stress during Si volume changes. The adhesion property of each polymeric binder in Si anode was confirmed by surface and interfacial cutting analysis system (SAICAS) (Si anode based on PI polymeric binder = $0.217kN\;m^{-1}$ and Si anode based on PVDF polymeric binder = $0.185kN\;m^{-1}$).

Electrochemical Characteristics of Graphite/Silicon/Pitch Anode Composites for Lithium Ion Batteries using Silica-Coated Graphite (실리카로 코팅된 흑연을 이용한 리튬 이차전지용 흑연/실리콘/피치 복합소재의 전기화학적 특성)

  • Lee, Su Hyeon;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.58 no.1
    • /
    • pp.142-149
    • /
    • 2020
  • In this study, the electrochemical performance of Graphite/Silicon/Pitch composites as anode material was investigated to improve the low theoretical capacity of artificial graphite. Spherical artificial graphite surface was coated with polyvinylpyrrolidone (PVP) amphiphiles material to synthesize Graphite/Silica material by silica islands growth. The Graphite/Silicon/Pitch composites were prepared by petroleum pitch coating and magnesiothermic reduction. The Graphite/Silicon/Pitch composite electrodes manufactured using poly(vinylidene fluoride) (PVDF), carboxymethyl cellulose (CMC) and polyacrylic acid (PAA) binders. The coin type half cell was assembled using various electrolytes and additives. The Graphite/Silicon/Pitch composites were analysed by X-ray diffraction (XRD), scanning electron microscope (SEM) and a thermogravimetric analyzer (TGA). The electrochemical characteristics of Graphite/Silicon/Pitch composite were investigated by constant current charge/discharge, rate performance, cyclic voltammetry and electrochemical impedance spectroscopy. The Graphite/Silicon/Pitch composites showed high cycle stability at a graphite/silica/pitch ratio (1:4:8 wt%). When the electrode is prepared using PAA binder, the high capacity and stability is obtained. The coin type half cell assembled using EC: DMC: EMC electrolyte showed high initial capacity (719 mAh/g) and excellent cycle stability. The rate performance has an capacity retention (77%) at 2 C/0.1 C and an capacity recovery (88%) at 0.1 C / 0.1 C when the vinylene carbonate (VC) was added.

Purification and Characterization of Protease Produced by Aspergillus wentti Isolated from Korean Traditional Meju (한국 전통 메주 유래의 Aspergillus wentti가 생성하는 Protease 의 정제 및 특성)

  • Lim, Seong-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.161-167
    • /
    • 2000
  • The protease produced by a newly isolated Aspergillus wentti from Korean traditional Meju was purified and characterized. The optimal medium composition and culture conditions for maximum protease production were ; bran :1% glucose solution =1 : 1, pH 9.0, $30^{\circ}C$, and 4 days of fermentation. Protease was purified by QAE-Sephadex, SP-Sephadex ion exchange chromatography and Sephadex G-100 chromatography. The specific activity and the purification fold of the purified enzyme were 213 unit/mg protein and 27.3, respectively. The molecular weight of purified protease was found to be 32 kDa by SDS-PAGE. Km and Vmax value's for hammastein milk casein were $3.049{\times}10^{-4}\;M\;and\;151.1\;{\mu}g/min$, respectively. Kinetic parameters showed that the enzyme has higher affinity to casein than isolated soybean protein, hemoglobin and bovine serum albumin. Optimal pH and temperature for reaction of the purified enzyme were 9.0 and $50^{\circ}C$, respectively. The enzyme was stable at pH 4.0-11.0, below $40^{\circ}C$, and the activity was not stimulated by metal ions. 1mM phenylmethylsulfonyl fluoride inhibited the enzyme activity by 98.5%. It means that the enzyme is one of serine protease.

  • PDF

Effect of Binder and Electrolyte on Electrochemical Performance of Si/CNT/C Anode Composite in Lithium-ion Battery (리튬이온 이차전지에서 Si/CNT/C 음극 복합소재의 전기화학적 성능에 대한 바인더 및 전해액의 효과)

  • Choi, Na Hyun;Kim, Eun Bi;Yeom, Tae Ho;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.60 no.3
    • /
    • pp.327-333
    • /
    • 2022
  • In this study, silicon/carbon nanotube/carbon (Si/CNT/C) composites for anode were prepared to improve the volume expansion of silicon used as a high-capacity anode material. Si/CNT were prepared by electrostatic attraction of the positively charged Si and negatively charged CNT and then hydrothermal synthesis was performed to obtain the spherical Si/CNT/C composites. Poly(vinylidene fluoride) (PVDF), polyacrylic acid (PAA), and styrene butadiene rubber (SBR) were used as binders for electrode preparation, and coin cell was assembled using 1.0 M LiPF6 (EC:DMC:EMC = 1:1:1 vol%) electrolyte and fluoroethylene carbonate (FEC) additive. The physical properties of Si/CNT/C anode materials were analyzed using SEM, EDS, XRD and TGA, and the electrochemical performances of lithium-ion batteries were investigated by charge-discharge cycle, rate performance, dQ/dV and electrochemical impedance spectroscopy tests. Also, it was confirmed that both capacity and rate performance were significantly improved using the PAA/SBR binder and 10 wt% FEC-added electrolyte. It is found that Si/CNT/C have the reversible capacity of 914 mAh/g, the capacity retention ratio of 83% during 50 cycles and the rate performance of 70% in 2 C/0.1 C.

Effect of Evaluation Conditions on Electrochemical Accelerated Degradation of PEMFC Polymer Membrane (PEMFC 고분자 막의 전기화학적 가속 열화에 미치는 평가조건들의 영향)

  • Sohyeong Oh;Donggeun Yoo;Suk Joo Bae;Sun Geu Chae;Kwonpil Park
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.356-361
    • /
    • 2023
  • In order to improve the durability of the proton exchange membrane fuel cell (PEMFC), it is important to accurately evaluate the durability of the polymer membrane in a short time. The test conditions for chemically accelerated durability evaluation of membranes are high voltage, high temperature, low humidity, and high gas pressure. It can be said that the protocol is developed by changing these conditions. However, the relative influence of each test condition on the degradation of the membrane has not been studied. In chemical accelerated degradation experiment of the membrane, the influence of 4 factors (conditions) was examined through the factor experiment method. The degree of degradation of the membrane after accelerated degradation was determined by measuring the hydrogen permeability and effluent fluoride ion concentration, and it was possible to determine the degradation order of the polymer membrane under 8 conditions by the difference in fluoride ion concentration. It was shown that the influence of the membrane degradation factor was in the order of voltage > temperature > oxygen pressure > humidity. It was confirmed that the degradation of the electrode catalyst had an effect on the chemical degradation of the membrane.

Comparison of Prevention Methods against Enamel Demineralization adjacent to Orthodontic Bracket Using Fluoride (교정용 브라켓 주위의 불소를 이용한 법랑질 탈회 예방 방법 비교)

  • Mo, Hyelim;Kim, Jongsoo;Oh, Sohee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.3
    • /
    • pp.293-300
    • /
    • 2019
  • As a common side effect of fixed orthodontic treatment, demineralization of the enamel adjacent to the bracket and band occurs in patients with poor oral hygiene. The purpose of this study was to investigate what is the most effective method to prevent demineralization around the fixed orthodontic appliance among various methods using fluoride. 80 extracted bovine incisors with a healthy surface were classified into four groups as experimental materials: (Group I) Control group, (Group II) V $varnish^{TM}$, (Group III) Tooth Mousse $Plus^{(R)}$, (Group IV) $Vanish^{TM}$ XT. After treatment for each group, mineral loss and Vickers surface microhardness were measured at 0, 30, 60 and 90 days after demineralization in artificial carious solution. Mineral loss was the lowest in group IV, followed by group II and group III, which showed a significant difference. The surface microhardness was the lowest in group IV, followed by group II and group III, which showed a significant difference. Through this study, group IV showed the best effect to prevent enamel demineralization around the bracket. Group III showed significant prevention of enamel demineralization compared with the control group, but the effect was less than that of the other groups.

Internal Mixing of Pollutants for Submicron Particles Observed during Springtime in Japan

  • Matsumoto, Jun;Narukawa, Masahiro;Takahashi, Kenshi;Matsumi, Yutaka;Yabushita, Akihiro;Shimizu, Atsushi;Matsui, Ichiro;Sugimoto, Nobuo
    • Asian Journal of Atmospheric Environment
    • /
    • v.3 no.1
    • /
    • pp.27-41
    • /
    • 2009
  • Internally mixed states of submicron particles during transport from the Asian continent to the Pacific Ocean were analyzed using a single-particle time-offlight mass spectrometer. The observation was conducted at Tsukuba in Japan in the spring of 2005 in order to investigate springtime transport of particles from the continent. The sum of ion intensities of sulfate (${HSO_4}^-$) detected in particles originating from the continental air masses counted for 75% of that in all particles during the observation. By analyzing correlations among compounds, origins and internally mixed states of compounds were estimated. It was found that nitrate was mixed with sulfate-rich particles as the air mass approached Japan. It was confirmed that Asian mineral dust particles played significant roles for transport of continental sulfate to Japan. As a result of analysis on internal mixing of chlorine and nitrate, it was implied that the chlorine loss in fine sea salt particles had already proceeded at Tsukuba. It was characteristic that fluoride ions were significantly detected, coal combustion in the Asian Continent can be an important source of fluorides detected in Japan through the westward transportation of fine particles including fluorides.

A STUDY ON THE SOLUBILITY OF DENTAL RESTORATIVE MATERIALS (치과용 수복재의 용해성에 관한 분석연구)

  • Na, Keung-Kyun;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.87-105
    • /
    • 1991
  • The purpose of this experiment was to measure the leaking and solubility of commonly used dental restorative materials - Silux plus (CS), Hi-pol (CH), Clearfil F-II, Fissureseal (FS), Glass-Ionomer cement Fuji Type II (GI), Amalgam Cavex 68 (AM), Zinc Phosphate Cement (ZP) and gutta-percha (GP) and investigate the relation between the solubility and marginal leakage. Disc-shape specimens were fabricated with each material and dipped into deionized water, 0.01M lactic acid and 0.005M KOH solution, thus the total ionic concentrations in each solution was measured with ion chromatograph after 1, 3, and 7 days, respectively. For the solubility test, each specimen was immersed in 0.001M and 0.01M lactic acid for 24 hours, respectively and total weight loss was calculated. Also, Zn leaking through the margin of restorations was measured. The obtained results were as follows: 1. The amounts of eluted ion from the eight materials were most in 0.01M lactic acid and least in deionized water. 2. Of the eight materials, the fluoride release was greatest for glass ionomer cement (GI) in 0.01 M lactic acid after 7 days. 3. In analysis of the divalent cation, Mg was eluted most for zinc phosphate cement (ZP) and Ca for Clearfil F-II (CF) in 0.01M lactic acid after 7 days. 4. In analysis of transition metals, Cu and Zn were detected only. 5. The solubility rate of eight materials was greater in 0.01M lactic acid than in 0.001M for 24 hours, for zinc phosphate cement (ZP) the rate was greatest (5.4%) in 0.001M lactic acid, and amalgam least (0.01%). 6. The Zn concentration of restorative material with Z.P.C base was greater in 0.01M lactic acid than in 0.001M lactic acid.

  • PDF

A Study on the Preparation and Characterization of Sulfonated PS/PVdF Composite Membranes (술폰화 폴리스틸렌/폴리비닐리덴플로라이드 복합막의 제조 및 특성에 관한 연구)

  • Hong, Young-Taik;Jung, Yeon-Gu;Park, Hyung-Su;Byun, Hong-Sik
    • Membrane Journal
    • /
    • v.16 no.4
    • /
    • pp.286-293
    • /
    • 2006
  • Porous asymmetric membranes based on PVdF as a nascent membrane were prepared by using a phase inversion method. PVdF ion conductive composite membranes were finally made by introducing $SO_3{^-}$ from sulfuric acid after cross-linked PS with various DVB contents in the pores of PVdF. Final PVdF composite membranes were characterized by FTIR, SEM, EDS to verify $SO_3{^-}$. It was revealed that the solvent contents and ion exchange capacity (IEC) decreased with increase of the degree of cross-linking. As the degree of crosslink increases both the electric conductivity and methanol permeability decreased, which was showing the better values than Nafion 117. When DVB content was 8%, its electric conductivity ($5.58{\times}10^{-5}S/cm$) was similar to Nafion 117 ($6.03{\times}10^{-5}S/cm$). But the lower methanol permeability ($1.0{\times}10^{-6}cm^2/sec$) than that of Nafion 117 was obtained.