• Title/Summary/Keyword: Fluoride Glass

Search Result 97, Processing Time 0.026 seconds

Preparation and Characterization of Microporous PVdF Membrane for Li-ion Rechargeable Battery (이차전지용 미세다공성 PVdF 분리막의 제조와 물성)

  • Nam, Sang-Yong;Yu, Dae-Hyun;Jeong, Mi-Ae;Rhim, Ji-Won;Byun, Hong-Sik;Jeong, Chul-Ho;Lee, Young-Moo;Seo, Myung-Su
    • Membrane Journal
    • /
    • v.17 no.3
    • /
    • pp.233-243
    • /
    • 2007
  • In this study, a separate. which is a microporous membrane based on poly(vinylidene fluoride)(PVdF) was prepared by phase inversion method. Being prepared by dissolving the PVdF in the N,N'-dimethylformamide(DMF) with mechanical stirring, the homogenous casting solution was cast onto a clean glass plate. Pore size and porosity of the membranes were controlled by changing preparation condition. The highest porosity of the membrane was 78.6%. The mechanical property of the membrane was determined by using an universal testing machine(UTM). The morphology of the membrane was investigated by scanning electron microscopy(SEM). The cross-section of the membrane shows sponge-like small micro-pores.

Eelctrical and Structural Properties of $CaF_2$Films ($CaF_2$ 박막의 전기적, 구조적 특성)

  • 김도영;최석원;이준신
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.12
    • /
    • pp.1122-1127
    • /
    • 1998
  • Group II-AF_2$films such as $CaF_2$, $SrF_2$, and $BaF_2$ have been commonly used many practical applications such as silicon on insulatro(SOI), three-dimensional integrated circuits, buffer layers, and gate dielectrics in filed effect transistor. This paper presents electrical and structural properties of fluoride films as a gate dielectric layer. Conventional gate dielectric materials of TFTs like oxide group exhibited problems on high interface trap charge density($D_it$), and interface state incorporation with O-H bond created by mobile hydrogen and oxygen atoms. To overcome such problems in conventional gate insulators, we have investigated $CaF_2$ films on Si substrates. Fluoride films were deposited using a high vacuum evaporation method on the Si and glass substrate. $CaF_2$ films were preferentially grown in (200) plane direction at room temperature. We were able to achieve a minimum lattice mismatch of 0.74% between Si and $CaF_2$ films. Average roughness of $CaF_2$ films was decreased from 54.1 ${\AA}$ to 8.40 ${\AA}$ as temperature increased form RT and $300^{\circ}C$. Well fabricated MIM device showed breakdown electric field of 1.27 MV/cm and low leakage current of $10^{-10}$ A/$cm^2$. Interface trap charge density between $CaF_2$ film and Si substrate was as low as $1.8{\times}10^{11}cm^{-2}eV^{-1}$.

  • PDF

The Effect of Silver Diamine Fluoride on Salivary Biofilm (Silver diamine fluoride가 타액 생물막에 미치는 영향)

  • Seo, Meekyung;Song, Ji-Soo;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Young-Jae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.4
    • /
    • pp.406-415
    • /
    • 2020
  • Silver diamine fluoride (SDF) is an effective and efficient agent for arresting dental caries. It can be useful in treating children with behavioral or medical limitations. The purpose of this study was to evaluate the antimicrobial effect of SDF by using salivary biofilm. Pellicle-like saliva coated structure was prepared by using unstimulated saliva. For developing cariogenic biofilm, Streptococcus mutans was added to the mixture of pooled saliva and inoculated into a saliva coated glass or chamber. SDF was applied to cariogenic biofilm to evaluate the antimicrobial effect of SDF. As time passed, total bacteria and S. mutans were reduced after application of SDF (p < 0.000). Confocal laser scanning microscope also showed the increment of the ratio of dead cell. As a result of experiment using enamel and dentin of primary teeth, it was confirmed that the growth of cariogenic biofilm was inhibited when the SDF was treated (p = 0.029 each). This study showed excellent anti-microbial effect of SDF. And anti-caries effect in clinical practice can be expected.

ANTICARIOGENCI EFFECT OF COMPOMER AND RMGIC (수복용 compomer 의 항우식성에 관한 연구)

  • Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.12-15
    • /
    • 2002
  • The first purpose of present study was to compare the anticariogenic effect of compomer, resin modified glass ionomer cement and composite (RMGIC). The second purpose was to evaluate the recently introduced methods, which use confocal scanning micro-scope, in detecting initial caries around restoration. 2$\times$4$\times$1.5mm cavities were prepared from the recently extracted 50 human teeth on the buccal or lingual surface. The prepared teeth were randomly devided into 5 groups and restored with each filling material. Group 1: Dyract AP, Group 2: compoglass F, Group 3: F2000, Group 4: Z100. Group 5:Fuji II LC. The teeth were stored for 30 days in the distilled water, then stored in the buffer solution for artificial caries development: pH 4.3, lactic acid 100 mM, calcium 16 mM, phosphate 8mM, sodium azide 3mM. Then, the samples were sectioned longitudinally and examined with confical scanning microscope. The results showed that the use of compomer and resin modified glass ionomer cement showed caries inhibition zone whereas the composite did not. There was no difference in the width of caries inhibition zone between compomers and RMGIC. The confocal scanning microscope was useful in detecting initial caries around restoration.

All Carrier Ohmic-Contacts을 이용한 유기 발광 다이오드의 성능 향상 연구

  • Park, Jin-U;Im, Jong-Tae;Yeom, Geun-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.168-168
    • /
    • 2012
  • 본 연구에서는 Molybdenum oxide (MoOx)-doped 4,4',4"-tris[2-naphthyl(amino)] triphenylamine(2-TNATA)의 P-doping에 의한 hole ohmic contact과 fullerene (C60)/lithium (LiF)의 electron ohmic contact에 의한 All Ohmic contact를 이용한 유기 발광 다이오드 (OLEDs)의 광저항 특성의 향상을 설명한다. 이 소자의 성능은 MoOx-doped 2-TNATA의 두께와 도핑농도에 큰 영향을 받는다. glass/ITO/MoOx-doped 2-TNATA (100 nm)/Al 구조의 소자에서 MoOx-doped 2-TNATA 도핑 농도가 25%에서 75%로 증가할수록 hole only device의 hole ohmic 특성이 향상됐다. 그 이유는 p-type doping effect 때문이다. 또한 photoemission spectra 분석결과, p-type doping effect는 hole-injecting barrier 높이는 낮추고, hole conductivity는 향상되었다. 이것은 2-TNATA에 도핑된 MoOx의 전하전송 콤플렉스의 형성으로 hole carrier의 수가 증가하여 발생되었다. MoOx-doped 2-TNATA의 hole ohmic contact과 fullerene (C60)/lithium fluoride (LiF)의 electron ohmic contact 으로 구성된 glass/ITO/MoOx-doped 2-TNATA (75%, 60 nm)/NPB (10 nm)/Alq3 (35 nm)/C60 (5 nm)/LiF (1 nm)/Al (150 nm)의 소자구조는 6,4V에서 127,600 cd/m2 최대 휘도와 약 1,000 cd/m2에서 4.7 lm/W의 높은 전력 효율을 보여준다.

  • PDF

Effect of Chemically Etched Surface Microstructure on Tribological Behaviors

  • Hye-Min Kwon;Sung-Jun Lee;Chang-Lae Kim
    • Tribology and Lubricants
    • /
    • v.40 no.3
    • /
    • pp.84-90
    • /
    • 2024
  • This study investigates the effect of the surface microstructure on the tribological characteristics of glass substrates. Chemical etching using hydrofluoric acid and ammonium hydrogen fluoride was employed to create controlled asperity structures on glass surfaces. By varying the etching time from 10 to 50 min, different surface morphologies were obtained and characterized using optical microscopy, surface roughness measurements, and water contact angle analysis. Friction tests were performed using a stainless steel ball as the counter surface to evaluate the tribological behavior of the etched specimens. The results showed that the specimen etched for 20 min exhibited the lowest and most stable friction coefficient, which was attributed to the formation of a uniform and dense asperity structure that effectively reduced the stress concentration and wear at the contact interface. In contrast, specimens etched for shorter (10 min) or longer (30-50 min) durations displayed higher friction coefficients and accelerated wear owing to nonuniform asperity structures that led to local stress concentration. Optical microscopy of the wear tracks further confirmed the superior wear resistance of the 20-minute etched specimen. These findings highlight the importance of optimizing the etching process parameters to achieve the desired surface morphology for enhanced tribological performance, suggesting the potential of chemical etching as a surface modification technique for various materials in tribological applications.

A Study on the Chemical Treatments Suitable for the Simple Mechanical Manipulation During the Recycling Process of FRP Waste from Ships (폐 선박의 FRP를 재활용 과정에서 용이한 기계적 조작을 위한 화학적 처리 방법에 관한 연구)

  • Lee, Seung-Hee;Kim, Yong-Seop;Yoon, Koo-Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.1
    • /
    • pp.55-59
    • /
    • 2009
  • As one of the methods for recycling the FRP from the small and medium waste ships, separation of roving layer from the mat has some merits in a sense of the recycling energy and the environmental effects. Similar characteristics, however, between the roving and the mat even with different ratio of the resin and the glass and the thickness of the roving, much thinner than the mat, make the mechanically automatic differentiation difficult. In this study spectrochemical differentiation between the two layers has been made using (1) boiling concentrated sulfuric acid which can dissolve the resin in the FRP layer, (2) methanol and isopropanol solution saturated with KOH which can dissolve the glass, or (3) hydrogen fluoride(HF) solution which can reacts with $SiO_2$ fragments of the glass. Furthermore coloring water-soluble dye following the HF treatment makes the roving layer more distinguishable photo-physically.

  • PDF

Comparative Analysis of Water Absorption and Water Solubility of Alkasite-based Restorative Material

  • Myeong-Gwan Jih;Hye-Jin Cho;Eu-Jin Cha;Tae-Young Park
    • Journal of Korean Dental Science
    • /
    • v.16 no.1
    • /
    • pp.74-79
    • /
    • 2023
  • Purpose: Cention N (Ivoclar Vivadent) was a recently introduced alkasite-based restorative material that was expected to replace amalgam and glass ionomer cement. This material was an esthetic restoration with adequate mechanical strength and release of fluoride and calcium. The purpose of this study was to measure the water sorption and water solubility of Cention N and evaluate its long-term durability compared to other esthetic restorations (Resin-Modified Glass Ionomer cement [RMGIC], Giomer, Composite Resin). Materials and Methods: Twenty specimens each of Cention N (CN), Resin Modified-Glass Ionomer Cement (FJ), Giomer (BF), and Composite Resin (FZ) were made. After each specimen was completely dried in a desiccator for 24 hours using a vacuum pressure pump, the specimen was weighed (m1). After that, the specimen was immersed in distilled water at 37℃ for 7 days, stored in a drying oven, and weighed (m2). After drying completely for 24 hours in a desiccator, the specimen was weighed (m3) to calculate the water absorption and water solubility using Formulas 1 and 2. The measured values were statistically processed and analyzed using SPSS, and the significance level was set at 0.05. Result: When measuring water sorption, FJ (122.61 ㎍/mm3) showed significantly higher water sorption than CN (35.42 ㎍/mm3) (P<0.05). There was no significant difference between FZ (18.03 ㎍/mm3) and BF (14.76 ㎍/mm3) (P=0.930). When measuring water solubility, CN (6.65 ㎍/mm3) showed significantly higher water solubility than FJ (1.47 ㎍/mm3) (P<0.05). Conclusion: Cention N had lower water sorption than RMGIC, but higher water solubility, indicating that it is more vulnerable to moisture and has lessened long-term durability.

Selection of Dental Cements (치과용 합착제의 선택)

  • Sung, Moo-Gyung
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.8 no.1
    • /
    • pp.76-82
    • /
    • 1999
  • Zinc phosphate cement has long been the material of choice for permanent luting of cast restorations, and through many years of use has been considered effective to retain castings. However, cast restorations cemented with this material have been susceptible to secondary caries. Glass ionomer luting agents become available in the late 1970s. These material s, through release of fluoride, show considerable promise as a means of reducing secondary caries. Other favorable traits include significantly less disintegration in vivo than zinc phosphate cements, a film thickness comparable to that of zinc phosphate cement, and adhesion to tooth structure. Compomer materials were created in 1993 as a filling material for deciduous teeth, cervical lesions, and class III cavities. In the meantime, compomer have been developed as chemical hardening cements for cast gold restorations. The aim of this paper is to review the articles on luting cements to help the choice of dental cements.

  • PDF

A Study on Ferroelectric Properties of VDF/TrFE copolymer (VDF/TrFE 공중합체(共重合體)의 강유전특성(强誘電特性))

  • Bang, T.C.;Kang, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1472-1475
    • /
    • 1996
  • D-E hysteresis loops have been measured for the 65/35 mole % copolymer of vinylidene fluoride and trifIuoroethyIene over wide temperature range. The results were analyzed and discussed. The remanent polarization and the coercive field at room termperature were estimated to be 75 $mC/m^3$ and 55 MV/m respectively. D-E hysteresis loops were observed even below the glass transiation temperature$-20^{\circ}C$) and the remanent polarization and the coercive field were larger than larger, as the temperature lower. It seems that the remanent polarization and the coercive field depend on the amorphous region as well as crystalline region in this copolymer. And the ferroelectric-to-paraelectric phase transition was observed at $90^{\circ}C$ on heating and $80^{\circ}C$ on cooling. Double hysteresis loops were observed at the temperature($85^{\circ}C$) of paraelectric phase.

  • PDF