• Title/Summary/Keyword: Fluorescent light source

Search Result 170, Processing Time 0.026 seconds

Growth Responses and Introduction Plan of Interior Landscape Plants under Light Intensity of Fluorescent Light and Sunlight (형광등과 자연광의 광도에 따른 실내조경식물의 생육반응과 도입 방안)

  • Choi Kyoung-Ok;Lee Sang-Woo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.4 s.111
    • /
    • pp.119-128
    • /
    • 2005
  • This study was carried out to obtain fundamental information of growth response of interior landscape plants under a fluorescent lighting, a sunlight at indoor. Ficus elastica Roxb. vu. decora Hort, Spathiphyllum 'Clevelandii', Codiaeum variegatum Blume var. pictum Mvell. Arg. 'Exalant' and Cordyline terminalis Kunth var. red edge Hort were examined under 100lux, 500lux, 1,000lux and 2,000lux light intensity consisted of fluorescent lighting and sunlight at indoor condition. Result of experiments are as follows; 1. A Ficus elastica Roxb. var. decora Hort plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status showed the best result under 2,000lux light intensity of fluorescent lighting in cases of all conditions. 2. A Spathiphyllum 'Clevelandii' showed the best effective adaptations under law intensity among experimental plants. A Spathiphyllum 'Clevelandii', plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status showed the best result under 1,000lux light intensity of fluorescent lighting in cases of all conditions. 3. It need the best high establishment of fluorescent lighting among experimental plants for good plant growth. A Codiaeum variegatum Blume var. pictum Mvell. Arg. 'Exalant' plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status was better showed under high light intensity in case of same light source. A plant growth status showed the best result under 2,000lux light intensity of fluorescent lighting. 4. A Cordyline terminalis Kunth var. red edge Hort plant growth status was better showed under fluorescent lighting than sunlight. but, A plant growth status was better showed under $500lux\sim1,000lux$ than 2,000lux in cases of all intensity of fluorescent lighting. while, A plant growth status was better showed under $1,000lux\sim2,000lux$ in cases of all intensity of sunlight.

Effects of Correlated Color Temperature of LED Light Sources and a Flourescent Light Source on Visual Performance (LED광원과 형광광원의 상관색온도가 시작업 성능에 미치는 영향)

  • Baik, Seung-Heon;Jeong, In-Young;Shin, Hwa-Young;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.18-26
    • /
    • 2009
  • Recently, from an environmental conservative point of view, the need of high-efficiency lighting system, using LED(Light Emitting Diode) light sources have been increased. However, applied LED light sources without regard to its color and pattern provide visual discomfort to occupant. The objective of this study is not only to evaluate the performance of task work under different correlated color temperature condition, but also furnish the preliminary data as concerning its purpose and user of inner space. For the purpose of this study, two types of LED light sources and a fluorescent light source were selected. Thirty undergraduate students served as the participants. Two different task work sheets were conducted to evaluate the accuracy and duration of time. Results from subjective performance, task work of error modification showed that LED light sources were 2.5[%] higher in accuracy with 17.1[%] lower duration than a fluorescent light source. In the case of reading task work, It is presented 20.6[%] decrease with the LED light sources comparison with a fluorescent light source.

Growth of Ulva pertusa Kjellman (Chlorophyta, Ulvophyceae) by a Light-Emitting Diode (LED) Light Source (발광다이오드(LED) 조명을 이용한 녹조 구멍갈파래(Ulva pertusa)의 생장)

  • Kwon, Chun Jung;Choi, Chang Geun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.46 no.5
    • /
    • pp.571-574
    • /
    • 2013
  • To determine an efficient growth system for algal cultivation and to develop adequate culture system utilizing LED light, we investigated the effects of fluorescent and light emitting diode (LED) light source on the growth of Ulva pertusa. U. pertusa was cultured at $17^{\circ}C$ under a light intensity of 35 ${\mu}mol$ photons $m^{-2}s^{-1}$ and a 10L:14D photoperiod using either fluorescent or LED lamps. After 1 week of incubation under the same environmental condition, the length and width of Ulva pertusa grown under LED light were 1.5- and 1.9-fold greater, respectively, than the length and width of algae grown under fluorescent light. After two weeks, length and width were 2.6- and 2.0-fold greater, respectively, in algae grown under LED light. Total length and width of Ulva pertusa after three weeks of incubation were 1.7- and 1.2-fold greater in algae grown under LED light than those grown under fluorescent light. Therefore, the LED light induced significantly higher growth of Ulva pertusa than fluorescent light.

Analysis on the Light Source Efficiency of CCFL and LED Monitors (CCFL 및 LED 모니터 광원 효율 분석)

  • Shin, Hee-Woo;Yoo, Jae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.6
    • /
    • pp.44-50
    • /
    • 2021
  • In this paper, we analyze the efficiency of light sources of CCFL and LED monitors. Cold Cathode Fluorescent Lamp (CCFL), which is widely used as a light source for LCD display, supplies a high voltage of 1,200[V] or more when it is initially driven. In addition, a constant normal voltage of 400 ~ 800[V] after lighting, and 3 ~ 6[ mA] is needed for a power circuit that can stabilize the current. Applying a high voltage causes a lot of stress on the inverter and generates a lot of heat in the cold cathode lamp, causing significant damage to the BLU (Back Light Unit), resulting in a burning phenomenon, which causes the screen to output normal colors when outputting the screen. We can not see the yellow output and the screen darkened. Therefore, in order to prevent such a symptom in advance, efficiency can be increased by using a Light Emitting Diode (LED) as the light source of the LCD display instead of a cold cathode fluorescent lamp (CCFL). As a result, it is shown that the LED method outperforms the CCFL method.

Comparative Luminance and Correlated Color Temperature of Work-place by a Fluorescent and LED Light Sources (LED광원과 형광광원에 의한 작업면의 휘도 및 색온도 비교)

  • Baik, Seung heon;Jeong, In Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.6
    • /
    • pp.21-26
    • /
    • 2008
  • According to the tendency of energy efficiency and environment-friendly chracteristics, demend of High-efficiency lighting using LED(Light Emitting Diode)are being increased actively and applied in various fields. However, In order to adequate application of LED light sources, it is necessary to lighting environment and luminous characteristics of LED light sources. This Study aims to characterize the work-plane lighting environment by LED light sources comparing with fluorescent light sources which are widely used. For the sake of this study, a fluorescent light source and 5 LED light sources were introduced and luminance and correlated color temperature were measured to evaluate luminance contrast. The experimental model is Mock-up which is $4.9m{\times}7.2m$ with a height of 2.9m. The test room was set up partition and desks. Luminance and correlated color temperature were measured work-plane on the desk which was set up local lighting by the Radiant Imaging ProMetric 1400. The optical characteristics data of LED can give a lot of advantages to design LED lighting appliances. Hereafter, the object of research will be conducted to evaluate effects of LED light sources on working performance, survey of visual performance, preference and physiology of subjects.

Growth Characteristics of Microalgae Haematococcus pluvialis by LED Light Source (LED 광원에 따른 미세조류 Haematococcus pluvialis의 성장 특성)

  • Lee, Geon Woo;Kim, Song Yi;Yoo, Yong Jin;Lee, Young Bok;Kim, Jin Woo;Kim, Ho Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.64-71
    • /
    • 2020
  • This study evaluated the effects of the culture media and light sources on the growth of microalgae Haematococuus pluvialis. Limited ingredient medium, Modified Bold's Basic Medium (MBBM), commercial liquid fertilizer medium Neo, and seven different light sources with different wavelengths were used to incubate H. pluvialis for 39 days, and the growth rates were compared. As a result, the growth of H. pluvialis, a limited ingredient medium, produced the highest cell growth in the fluorescent light source while cell growth was the lowest in the blue+red LED. The growth of H. pluvialis in commercial medium Neo was highest in the fluorescent light source, and cell growth was lowest in the blue LED. In this study, the MBBM culture medium showed better results than the Neo culture medium. Microalgae grown in the fluorescent light source using the MBBM culture medium showed the best cell growth result in this study. The results were optimized for the culture medium, light source, and light quantity in H. pluvialis culture for the production of secondary metabolites and provide basic data for the mass culture of microalgae.

Light Intensity and Spectral Characteristics of Fluorescent Lamps as Artificial Light Source for Close illumination in Transplant Production Factory (식물묘공장의 근접조명용 인공광원으로서 형광등의 광강도 및 분광 특성)

  • 김용현;이종호
    • Journal of Biosystems Engineering
    • /
    • v.23 no.6
    • /
    • pp.591-598
    • /
    • 1998
  • Light intensity and spectral characteristics of different types of fluorescent lamps were tested to investigate their possibility as the artificial lighting sources for the close illumination applied in the transplant production factory. Photosynthetic photon flux densitiy(PPF), illuminance and irradiance for all lamps decreased logarithmically with an increase of the vertical distance from the lighting source. The fluorescent lamp specially designed plant growth (PG lamp) showed a maximum spectral irradiance at the wavelength of 660nm. However, it showed lower irradiance than that of a standard fluorescent lamp at the range of wavelength between 500 and 600nm. On the other hand, PG lamp showed higher PPF and lower illuminance than those of the standard fluorescent lamp. The maximum peak of spectral characteristics for both of the single and twin three-bind fluorescent lamps was shorn at the wavelength of 545m and the next peaks were shown at the wavelength of 610nm and 435nm, respectively. Since the red fluorescent lamp has a narrower peak at the wavelength of 660nm, it may be useful for the supplementary red lighting. For three of standard, single three-band and twin three-band fluorescent lamps, the values of conversion factor for converting illuminance to PPF fell within the narrow range from 76 to 791x/$\mu$molㆍm$^{-2}$ ㆍs$^{-l}$ . However, for PG lamp, it was 29.71x/$\mu$molㆍm$^{-2}$ ㆍs$^{-1}$. Also, the values of conversion factor for converting PPF to irradiance of fluorescent lamp used in this study ranged between 4.85 and 5.34$\mu$molㆍm$^{-2}$ ㆍs$^{-1}$/Wㆍm$^{-2}$ .

  • PDF

The Growth Effects on Interior Landscape Plants by Optical Fiber Lighting System (광섬유 조명체계가 실내조경식물의 생육에 미치는 효과)

  • 최경옥;방광자
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.29 no.6
    • /
    • pp.92-100
    • /
    • 2002
  • This study was carried out to obtain fundamental information on the growth response of interior landscape plants under fluorescent light, sunlight and optical fiber lighting indoors. Saintpaulia ‘Delaware’, ‘Kalanchoe blossfeldiana, Anthurium scherzerianum and Ardisia crenata were examined using light intensity of 5001ux and 1,0001ux of fluorescent light, sunlight and optical fiber lighting in an interior environment. Results of experiments are as follows; 1) Plant growth status showed the best results under optical fiber lighting compared with fluorescent light or sunlight. 2) Plant growth status was better under 1,0001ux light intensity than 5001ux light intensity and in cases of the same light intensity, the highest growth increase was under optical fiber lighting. while it was showed relatively different according to the different plant species between a fluorescent light and sunlight. 3) The deep pinkish red color of Saintpaulia ‘Delaware’flower was obtained first under an optical fiber lighting and a fluorescent light, a sun light in that order. 4) Regarding interred activity, photosynthetic rate and transpiration rate, intercellular CO, water absorption rate showed a similar tendency generally in spite of a little difference. Namely, transpiration rate and intercellular CO, $CO_2$ a absorption rate increased according to increase of photosynthetic rate. 5) Photosynthetic rate of test plants except Anthurium scherzerianum increased according to increase of light intensity and increased highest under optical fiber lighting in the same light intensity condition. Increases differed under fluorescent light and sun light. That of Saineaulia ‘Delaware’and Anthurium scherzerianum increased in the order of optical fiber, fluorescent light and sun light, but that of Kalanchoe blossfeldiana and Ardisia pusilla increased in the order of optical fiber lighting, sun light and fluorescent light. Summing up these results, In visual value or internal health status of all experimental plants we obtained the highest result under an optical fiber lighting. Finally, we need to introduce an optical fiber lighting in interior landscape space as main light source.

A Study on the Application of LED Light Source in Subway Train (도시철도차량에 LED 광원의 적용에 관한 연구)

  • Choi, Sung-Kuk;Park, Dae-Won;Kil, Gyung-Suk;Park, Hee-Chul;Jo, Eun-Je
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.2050-2055
    • /
    • 2009
  • This paper describes the proceeding experimental results to replace the 32 [W] fluorescent lamp installed in subway train to a LED module. We fabricated 25 [W] LED modules to meet the illuminance 300 [lx] specified in the standard for subway train. After the installation of LED modules, comparative analysis with conventional fluorescent lamps was carried out. From the experimental results, illuminances on the height of 0.85 [m] and 1 [m] above floor were 323 [lx] and 360 [lx], respectively. These illuminances satisfied the requirement 300 [lx]. By the application of 25 [W] LED module as a light source in subway train, energy saving about 22 [%] compared with 32 [W] fluorescent is acquired. Also, low cost of maintenance is expected due to 8 times longer lifetime 50,000 hours of LED than that 6,000 hours of fluorescent lamp.

  • PDF

Flat Fluorescent Lamp(FFL) and Analysis of Optical Efficiency of FFL Lighting (면광원 램프 및 이를 이용한 조명 기기의 효율 특성 연구)

  • Park, Jong-Lee;Lim, Sung-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.6-12
    • /
    • 2007
  • A flat fluorescent lamp (FFL) developed as a light source for LCD TV backlight was used as a light source for general lighting application and its electro-optical characteristics were measured and evaluated. The channels of FFL were formed from a flat glass at high temperature by using a mold. The performance of FFL with lighting future was shown to improve by optimizing the channel profile of FFL. In this paper, the brightness efficiency of FFL with lighting fixture was evaluated and compared with that of the hot cathode fluorescent lamp (HCFL), the major light source for general lighting. The optical efficiency of FFL with future was shown to be 72.7[1m/W].