• 제목/요약/키워드: Fluorescent Lamps

검색결과 381건 처리시간 0.023초

Single-Stage High-Power-Factor Electronic Ballast with a Symmetrical Class-DE Resonant Rectifier

  • Ekkaravarodome, Chainarin;Jirasereeamornkul, Kamon
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.429-438
    • /
    • 2012
  • This paper presents the use of a novel, single-stage high-power-factor electronic ballast with a symmetrical class-DE low-$d{\upsilon}$/$dt$ resonant rectifier as a power-factor corrector for fluorescent lamps. The power-factor correction is achieved by using a bridge rectifier to utilize the function of a symmetrical class-DE resonant rectifier. By employing this topology, the peak and ripple values of the input current are reduced, allowing for a reduced filter inductor volume of the EMI filter. Since the conduction angle of the bridge rectifier diode current was increased, a low-line current harmonic and a power factor near unity can be obtained. A prototype ballast, operating at an 84-kHz fixed frequency and a 220-$V_{rms}$, 50-Hz line input voltage, was utilized to drive a T8-36W fluorescent lamp. Experimental results are presented which verify the theoretical analysis.

반파정류를 이용한 형광램프용 전자식 스타터의 개발 (Development of an electronic starter using a half-wave rectifier for fluorescent lamps)

  • 이동호;송상빈;여인선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2088-2090
    • /
    • 1998
  • A low-cost electronic starter is developed to decrease ignition failure significantly through successive starting trial and to prevent overheating at the end of fluorescent lamp life. Moreover, it has an additional feature of being capable of ignition at the recovered lamp voltage without any circuit correction. The developed electronic starter is consisted of four parts - a half wave rectifier circuit, a timer circuit, a switching circuit and a protection circuit. The protection circuit made up of a transistor and capacitors utilizing capacitive characteristics, carries out successive starting trial and end-of-life protection. Lamp ignition is completed within 0.5 seconds with taking advantage of a high preheating current from the half-wave rectifier circuit. Nevertheless, its performance is proved to be very excellent through a standard switching endurance test.

  • PDF

Photochemical Degradation of Dimethyl Phthalate by Fe(III)/tartrate/H2O2 System

  • Feng, Xianghua;Ding, Shimin;Xie, Faping
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권11호
    • /
    • pp.3686-3690
    • /
    • 2012
  • Photochemical degradation of dimethyl phthalate (DMP) in Fe(III)/tartrate/$H_2O_2$ system was investigated utilizing fluorescent lamps as the primary light source. Effects of initial pH, light source, and initial concentration of each reactant on DMP photodegradation was examined. The results show that the system was able to effectively photodegrade DMP utilizing visible light. Fluorescent lamp, halide lamp, UV lamp and sunlight could all be used as the light sources. The optimal pH ranged among 3.0-4.0 for the system. Increases of the initial concentrations of Fe(III) and $H_2O_2$ accelerated the photodegradation of DMP, whereas excessively high initial tartrate concentration resulted in the decrease of photodegradation efficiency and rate of DMP.

Dimming형 IC를 이용한 형광램프용 전자식 안정기의 회로상수 결정 (Determination of the circuit parameters of an electronic ballast for a fluorescent lamp using a dimming ballast controller)

  • 송상빈;김선;곽재영;여인선
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1998년도 학술발표회논문집
    • /
    • pp.156-161
    • /
    • 1998
  • The purpose of this paper is to determine circuit parameters in the inverter part of the electronic dimming ballast for fluorescent lamps, that is adequate to use with the prevailing dimming controller IC. Firstly, the operating frequency characteristics are investigated by varying circuit parameters of electronic ballasts and are matched with the output characteristics of dimming ballast controller. Secondly, circuit parameter values are determined by using PSpice simulation and operating frequency characteristics. Finally its validity is verified from the electrical and light output characteristics on the prototype of the electronic dimming ballast.

  • PDF

전압변동에 따른 LED 조명의 특성분석 (Characterization of LED Lighting according to Voltage Variation)

  • 이대우;이종필;지평식
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.271-276
    • /
    • 2014
  • LED lighting has received worldwide attention as advantages, such as environment-friendly than the conventional light, the excellent energy efficiency, and a semi-permanent lifetime. The use of the SMPS increased with the rapid growth in the LED industry. Increased use of SMPS means an increase in the harmonic generation load. Therefore, LED lighting compared with conventional fluorescent lamps were tested in this paper for characterized by a light source, electrical and harmonic characteristics. Experiments results for LED lighting showed different characteristics from the existing fluorescent lamp. Especially harmonic characteristic results showed different characteristics in accordance with the power device manufacturing method for LED lighting.

형광등 Positive column에 대한 자장인가 효과 (Magnetic field effect on the positive column of fluorescent lamp)

  • 지철근;김창종
    • 전기의세계
    • /
    • 제31권3호
    • /
    • pp.197-203
    • /
    • 1982
  • The effects on the characteristics of 20-W fluorescent lamp were studied when applying magnetic field to its positive column. First, when the direction of the magnetic field is axial, i.e., along the lamp, if the magnitude of the field is stronger than the critical field, lamp voltage is increased, lamp current decreased, luminous flux increased, starting voltage decreased, as increasing the applied magnetic field. At the magnetic flux density is 130 gauss, luminous flux is increased to about 6 percents and starting voltage is increased to about 45 percents. Second, when the direction of the magnetic field is transverse to the lamp axis, as increasing the applied magnetic field, lamp voltage is increased, lamp current decreased, luminous flux increased and starting voltage is nearly constant, but the rates of increase or decrease of this case is different from those of the first. At the magnetic flux density is 300 gauss, luminous flux is increased about 45 percents. In both cases, electric power dissipated by lamps is the same as that of the lamp which magnetic field is not applied to.

  • PDF

A Life Cycle Cost Comparison of Low-pressure Sodium Lamp and Fluorescent Lamp for Tunnel Lighting

  • Lee, Young-Q.
    • Industrial Engineering and Management Systems
    • /
    • 제3권1호
    • /
    • pp.59-62
    • /
    • 2004
  • The number of tunnel has fast increased with the rapid expansion of highway network. Tunnel should be designed to provide for drivers both safety and pleasant driving conditions. In this perspective, the design for tunnel lightning is very important in order to provide its safety, pleasantness, and cost-efficiency of maintenance, all of which should be considered and analyzed for a better tunnel lighting. This paper attempts to compare the low-pressure sodium lamp, which have usually been used for tunnel lighting, with the fluorescent lamp, which we consider as an alternative for the former. In an effort to determine the number of lamps to meet the required illuminance in the tunnel, this research employs a simulation technique which would allow us to conjecture, with the aid of basic model, the life cycle cost for illumination per each tunnel. This analysis is expected to provide a basic method and related information for tunnel development and design.

저압 방전등 교류 접등 특성의 이론적 예측 (Theoretical Prediction of AC Characteristics of Low Pressure Lamps)

  • 지철근;장우진;여인선;이진우
    • 대한전기학회논문지
    • /
    • 제38권6호
    • /
    • pp.470-476
    • /
    • 1989
  • In order to develop a mathematical model which can predict the operating voltage and current of a discharge lamp, the properties and the physical phenomena of a low pressure gas discharge are investigated. Fluorescent lamp which uses a low pressure mercury-argon gas discharge is used in the model development. In a low pressure mercur-argon gas discharge, the continuity equation for each excited atom and electron, and the electron energy balance equation can predict the physical quantities of discharge. By coupling these equations and the circuit equation, the electrical characteristics of the discharge lamp can be predicted. To verify the validity of the suggested model, we calculated the voltage and current of a fluorescent lamp operating with inductor ballast for source frequency of 5KHz, 8KHz, 10KHz, and 13KHz. The results show good agreements in wave forms between the measured voltage and current, and the difference between the measured and calculated one is less than 5%.

  • PDF

단상전원에 적합한 LCC 직병렬 공진 특성 (Resonant Characteristics of LCC Series-Parallel for Single-Phase Power Source)

  • 이달은;윤신용;김일남;김철진;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1208-1210
    • /
    • 2004
  • The Cold-Cathode Fluorescent Lamps (CCFL) are widely used to illuminate the liquid crystal displays(LCD) used in many battery powered instrument. This paper presents analysis of fly-back converter for universal-line applications($90\sim265Vac$) and half-bridge type resonant inverter for CCFL drive for stable characteristic and life improvement of fluorescent lamp operation frequency is higher than resonant frequency for safe operation. The validity of this study was confirmed from the simulation and experiential result.

  • PDF

입력전류 파형 개선효과를 갖는 전자식 안정기에 관한 연구 (A Study on Electronic Ballast with Improved Input Current Waveform)

  • 허태원;손영대;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1239-1241
    • /
    • 2004
  • In this paper, electronic ballast with Interleaved Boost Cell is presented. The proposed topology is based on a single-stage ballast which combines a boost converter and a half-bridge series resonant inverter High power factor and low THD(reduction of current ripple) are achieved by using the boost semi-stage operating in discontinuous conduction mode, and inverter semi-stage operated above resonant frequency to provide zero voltage switching is employed to ballast the fluorescent lamp. The experimental results from the ballast system with fluorescent lamps have demonstrated the feasibility of the proposed electronic ballast.

  • PDF