• 제목/요약/키워드: Fluorescence excitation

검색결과 233건 처리시간 0.023초

Fluorescence Spectroscopic and Time-Dependent Density-Functional Theory Studies of Diphenylsilane

  • Boo, Bong-Hyun;Lee, Jae-Kwang
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권3호
    • /
    • pp.993-996
    • /
    • 2012
  • We investigated fluorescence and fluorescence excitation of diphenylsilane (DPS) in a solution and molecular beams in combination with the aid of the DFT method. When the molecule was photoexcited at 250 nm in a cyclohexane solution, normal and excimer fluorescences were observed in the ranges of 260-320 and 330-450 nm, respectively. The fluorescence excitation spectrum indicates that the channel leading to the intramolecular excimer formation is not efficient in comparison with the normal fluorescence. Vibrationally resolved fluorescence excitation spectra were measured for the DPS molecules cooled in pulsed supersonic expansion of He in the range 262.2-271.7 nm, in which we can see several electronic excitation spectra exhibiting the electronic band origins. We found that the simulated absorption spectrum based on the time-dependent densityfunctional theory calculations accords well with the absorption spectrum.

도계육 표면 내장 잔유물 오염 검사를 위한 형광 조사 및 방출파장 선정에 관한 연구 (Study on Fluorescence Excitation and Emission Bands for Detection of Fecal Residue on Poultry Carcasses)

  • 조병관;김문성
    • Journal of Biosystems Engineering
    • /
    • 제33권2호
    • /
    • pp.136-141
    • /
    • 2008
  • Fecal contaminations on poultry carcasses, not easily discemable by human eyes, are potential harbor sites of pathogenic Escherichia Coli (E. coli O157:H7). Development of sensitive detection methods for fecal contamination is essential to ensure safe production of poultry products. Fluorescence has been shown to be very sensitive in detecting fecal and other biological substances that can harbor pathogens. In this study, fluorescence excitation-emission spectra of poultry fecal matter were compared with spectra for poultry skin and meat. Results indicated that the combinations of fluorescence intensities at the wavelength of 520 nm, 579 nm, 625 nm, and 635 nm with 411 nm excitation showed above 97% accuracy for differentiation of the contaminants from poultry tissues. Excitation and emission bands determined could be used for constructing a real-time fluorescence imaging device for detection of harmful residues on poultry carcasses.

복합 광원을 갖는 형광 내시경 개발 (Development of the Fluorescence Endoscope System with Dual Light Source Apparatus)

  • 배수진;강욱
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.222-226
    • /
    • 2007
  • We suggest the fluorescence endoscope system that has light source apparatus providing selectable white or excitation light. White light source generates normal color images and is easily switched over to excitation light with the wide spectrum range from 380 nm to 580 nm. 5-ALA is deposited selectively in the abnormal tissue like cancer and causes fluorescence in the red spectrum range when excited by blue spectrum range. In addition, the others of excitation light make the color background image by reflected light to allow accurate orientation and visualization of the abnormal tissue and around. According to clinical studies, the fluorescence intensity contrast that defines the fluorescence intensity of lesion over the fluorescence intensity of around has more than 2 in tumour. Proposed system is useful and objective way in early diagnosis. Furthermore, it can be used in the biopsy for tumour classification at the highest fluorescence intensity point.

Miniaturized Fluorometer Based on Total Internal Reflector and Condensing Mirror

  • Jang, Dae-Ho;Yoo, Jae-Chern
    • Journal of the Optical Society of Korea
    • /
    • 제17권1호
    • /
    • pp.81-85
    • /
    • 2013
  • A miniaturized fluorescence detection system based on total internal reflection (TIR) configuration, which is applicable to detecting the presence of biological materials labeled with fluorescence dye in micro total analysis systems (${\mu}TAS$), is proposed. In conventional fluorescence testing and analysis devices, interference between the excitation light beam and the emitted light from dyes is unavoidable. This paper presents a fluorescence detection system based on TIR configuration that allows the excitation light beam and the emitted light to be spatially perpendicular to each other so as to minimize the interference where fluorescence emission is detected at the orthogonal angle to the excitation beam. We achieved the limit of detection of about 5 nmol/L with a high linearity of 0.994 over a wide range of 6-FAM mol concentration, being comparable to that in earlier studies.

Double clad fiber probe for fluorescence spectroscopy

  • Wang, Ling;Lee, Byeong-Ha
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2007년도 하계학술발표회 논문집
    • /
    • pp.35-36
    • /
    • 2007
  • We report a probe using a single double clad fiber (DCF) for fluorescence spectroscopy. Bidirectional separate transmission for excitation and fluorescence light in a single fiber was implemented. A DCF coupler made by side-polished method could extract none but the collected fluorescence signals propagating in inner cladding mode, thereby diminishing the interference of silica background generated by the excitation in core mode. The experimental results show that the fluorescence spectra of biological tissues obtained using the DCF probes have much less silica background than using a standard multiple-mode fiber.

  • PDF

Spectroscopic Evidence for Aggregation of Stilbene Derivatives in Solution

  • Aguiar, M.;Akcelrud, L.;Pinto, M.R.;Atvars, T.D.Z.;Karasz, F.E.;Saltiel, Jack
    • Journal of Photoscience
    • /
    • 제10권1호
    • /
    • pp.149-155
    • /
    • 2003
  • The absorption, fluorescence and fluorescence-excitation spectra of concentrated toluene solutions of selected para substituted trans-stilbene derivatives provide strong evidence for aggregation. A red-shifted fluorescence spectrum peaking at 420 nm gains in intensity as the stilbene concentration is increased. The excitation spectrum of this new emission is well to the red of the normal stilbene absorption spectrum, consistent with the appearance of a red shifted shoulder in the UV spectrum. Formation of a fluorescent ground state dimer (or higher aggregate) is proposed to account for these observations. The presence of polar substituents is crucial to the formation of this ground state complex.

  • PDF

형광과 여기광을 공간적으로 분리하는 바이오칩용 소형 형광측정시스템 (Miniature Biochip Fluorescence Detection System with Spatial Separation of Fluorescence from Excitation Light)

  • 김호성;김용권;박주한;이국녕;최재호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권8호
    • /
    • pp.378-383
    • /
    • 2005
  • We report the development of miniature fluorescence detection systems that employ miniature prism, mirrors and low coat CCD camera to detect the fluorescence emitted from 40 fluorescently-labeled protein patterns without scanner. This kind of miniature fluorescence detection system can be used in point of care. We introduce two systems, one uses prism+mirror block and the other uses prism and two mirrors. A large NA microscope eyepiece and low cost CCD camera are used. We fabricated protein chip containing multi-pattern BSA labeled with Cy5, using MEMS technology and modified the surface chemically to clean and to immobilize proteins. The measurements show that the combination of prism and mirrors can homogenize elliptical excitation light over the sample with higher optical efficiency, and increase the separation between excitation and fluorescence light at the CCD to give higher signal intensity and higher signal to noise ratio. The measurements also show that protein concentrations ranging from 10 ng/ml to 1000 ng/ml can be assayed with very small error. We believe that the proposed fluorescence detection system can be refined to build a commercially valuable hand-held or miniature detection device.

Excitation and Emission Properties of Adsorbed U(VI) on Amorphous Silica Surface

  • Jung, Euo Chang;Kim, Tae-Hyeong;Kim, Hee-Kyung;Cho, Hye-Ryun;Cha, Wansik
    • 방사성폐기물학회지
    • /
    • 제18권4호
    • /
    • pp.497-508
    • /
    • 2020
  • In the geochemical field, the chemical speciation of hexavalent uranium (U(VI)) has been widely investigated by performing measurements to determine its luminescence properties, namely the excitation, emission, and lifetime. Of these properties, the excitation has been relatively overlooked in most time-resolved laser fluorescence spectroscopy (TRLFS) studies. In this study, TRLFS and continuous-wave excitation-emission matrix spectroscopy are adopted to characterize the excitation properties of U(VI) surface species that interact with amorphous silica. The luminescence spectra of U(VI) measured from a silica suspension and silica sediment showed very similar spectral shapes with similar lifetime values. In contrast, the excitation spectra of U(VI) measured from these samples were significantly different. The results show that distinctive excitation maxima appeared at approximately 220 and 280 nm for the silica suspension and silica sediment, respectively.

Excitation energy transfer from carotenoids probed by femtosecond time-resolved fluorescence spectroscopy

  • Akimoto, Seiji;Yamazaki, Iwao;Mimuro, Mamoru
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.78-81
    • /
    • 2002
  • Fluorescence rise and decay curves of carotenoids were measured in solutions and in pigment protein complexes with a femtosecond time-resolved fluorescence spectroscopy. For linear carotenoids, the S$_2$ lifetimes showed the maximum value around n = 9-10. The conjugation of a keto-carbonyl group shortened the S$_2$lifetime and prolonged the S$_1$lifetime. The excitation relaxation dynamics within carotenoids and the excitation energy transfer kinetics from carotenoids to chlorophylls are discussed as a function of molecular structure of carotenoids.

  • PDF