• Title/Summary/Keyword: Fluid Device

Search Result 699, Processing Time 0.029 seconds

Study on the Swirling Motion Effect of Ejector Performance (회전 운동이 이젝터 성능에 미치는 영향에 관한 연구)

  • Kang, Sang-Hoon;Park, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.544-549
    • /
    • 2017
  • This paper aims to examine the effect of rotational fluid motion about the efficiency of the gas - liquid ejector, which is a core unit in a ship equilibrium water treatment system. The ejector is a device for injecting ozone into ship equilibrium by the negative pressure generated by exchange of momentum between water and ozone. The existing ejector ejects the driving fluid with a simple form. In this paper, however, a rotation induction device is applied to the driving nozzle so that the driving fluid can be rotated and injected. To investigate the flow characteristics by the rotational movement of the driving fluid, CFD was used. The pressure and flow rate of the driving fluid, the negative pressure and suction flow rate of the suction fluid in the suction part, and the discharge pressure were predicted. On the basis of the results, the efficiency of the ejector using the rotation induction system was 22.25%, which was about 1.7% better than that of the existing ejector. Finally, to verify the feasibility of the CFD, an experiment was conducted on the ejector using the rotation induction device and the results were similar to those of the CFD.

Development of usability evaluation index of convergence technology remote fluid monitoring device for non-face-to-face patient nursing system application and analysis of results (비대면 환자 간호시스템 적용을 위한 융합기술의 원격 수액모니터링 장치 사용성평가 지표 개발 및 결과 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.4
    • /
    • pp.137-145
    • /
    • 2022
  • The usability evaluation of the remote fluid monitoring device, which was introduced to reduce the work of nurses and increase the efficiency, was performed due to the expansion of the non-face-to-face medical system. Remote fluid monitoring is a fusion of various technologies such as fluid measurement and analysis, error correction technology, and transmission technology. The range of use by users, the information they want to obtain, and the control device, etc. are wide, and the factors that evaluate the product are also diverse. Therefore, it is difficult to improve the product through evaluation. In this study, a quantitative index was developed to help improve the product for commercialization by conducting 20 usability evaluations in three areas of product stability, operability, and satisfaction with the remote sap monitoring system device. It was performed through infrared and load cell-type sap monitoring devices. In terms of stability, there was a difference in installation work such as fixing the pole of the device, and high satisfaction was shown for operability and accuracy. In terms of product satisfaction, the satisfaction of load cell devices was generally high.

Power Transmission Mechanism of Electrorheological Clutch Part I: Analytical development of power transmission mechanism (전기유변성 클러치의 동력전달 메커니즘 제1보: 동력전달 메커니즘의 해석적 전개)

  • 이규한;심현해;김창호;임윤철
    • Tribology and Lubricants
    • /
    • v.13 no.2
    • /
    • pp.27-38
    • /
    • 1997
  • ER clutch is a device using ER fluid, so called "intelligent material" and is a power transmission system controlled with electric field strength. This device responses very rapidly when controlled by rapid and continuous electrical signal and can form a servosystem. Wear, noise and vibration during operation is very low level. This study was undertaken to investigate substitutive possibilities of this ER clutch for existing power transmission mechanism. An analytic relationships using rheological model (so called, 'Bingham plastic model') of ER fluid were developed, and operation constraints and optimum design concepts were constructed. With this relationships, typical responses of ER clutch and effects of changing geometric, kinetic parameters of ER clutch and ER fluid properties were described. In conclusion, compared with existing mechanisms, an excellent performance of ER clutch was confirmed.confirmed.

New Device for Addition of Modifier to Supercritical Fluid Carbon Dioxide Mobile Phase

  • 표동진;김호현
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.6
    • /
    • pp.584-588
    • /
    • 1997
  • A new device to accurately deliver small amount of modifier into supercritical carbon dioxide fluid is described. Carbon dioxide, the most widely used mobile phase in supercritical fluid chromatography, is a relatively non-polar fluid, and hence the addition of small amount of polar modifiers could be necessary to migrate polar solutes. In this work, supercritical CO₂and modifier are delivered from the pump to a 100 μL mixing chamber in which a small magnetic bar is rotating. After passing through the mixing chamber, supercritical CO₂is changed to a new mobile phase with different polarity. The amount of modifier added into supercritical CO₂is measured by an amperometric microsensor, which is prepared from a thin film of perfluorosulfonate ionomer.

Device for Catheter Placement of External Ventricular Drain

  • Ann, Jae-Min;Bae, Hack-Gun;Oh, Jae-Sang;Yoon, Seok-Mann
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.3
    • /
    • pp.322-324
    • /
    • 2016
  • To introduce a new device for catheter placement of an external ventricular drain (EVD) of cerebrospinal fluid (CSF). This device was composed of three portions, T-shaped main body, rectangular pillar having a central hole to insert a catheter and an arm pointing the tragus. The main body has a role to direct a ventricular catheter toward the right or left inner canthus and has a shallow longitudinal opening to connect the rectangular pillar. The arm pointing the tragus is controlled by back and forth movement and turn of the pillar attached to the main body. Between April 2012 and December 2014, 57 emergency EVDs were performed in 52 patients using this device in the operating room. Catheter tip located in the frontal horn in 52 (91.2%), 3rd ventricle in 2 (3.5%) and in the wall of the frontal horn of the lateral ventricle in 3 EVDs (5.2%). Small hemorrhage along to catheter tract occurred in 1 EVD. CSF was well drained through the all EVD catheters. The accuracy of the catheter position and direction using this device were 91% and 100%, respectively. This device for EVD guides to provide an accurate position of catheter tip safely and easily.

Performance Evaluation of Vehicle Gear-shifting Supportive Device Utilizing MR Haptic Cue (MR 햅틱 큐를 이용한 차량 기어변속 보조장치의 성능평가)

  • Han, Young-Min;Min, Chul-Gi
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.2
    • /
    • pp.160-166
    • /
    • 2013
  • This paper proposes a driver supportive device with haptic cue function which can be applicable for vehicles adopting manual transmission system to transmit gear-shifting information to a driver by kinesthetic forces. This haptic cue function is implemented on accelerator pedal by utilizing magnetorheological(MR) fluid and clutch mechanism. In order to achieve this goal, an MR clutch mechanism is devised to be capable of rotary motion of accelerator pedal. The proposed MR clutch is then optimally designed and manufactured under consideration of spatial limitation of vehicles. After transmission torque is experimentally evaluated according to field intensity. The manufactured MR clutch is integrated with accelerator pedal and electric motor to establish the haptic cue device. Control performances are experimentally evaluated via a simple feed-forward control algorithm.

Effect of Double Grid Cathode in IEC Device (IEC 장치에서 이중 그리드 음극의 영향)

  • Ju, Heung-Jin;Kim, Bong-Seok;Hwang, Hwui-Dong;Park, Jeong-Ho;Ko, Kwang-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.51-51
    • /
    • 2010
  • We have proposed a new configuration for the improvement of neutron yield without the application of external ion sources in an inertial electrostatic confinement (IEC) device. The application of a double grid cathode to the IEC device is expected to generate a higher ion current than a single grid cathode. This paper verifies the effect of the double grid cathode by both fluid and particle simulation. Through the fluid simulation the optimal shape and applied voltage of the double grid cathode is determined, and through the particle simulation the usefulness of that is confirmed.

  • PDF

Modeling and testing for hydraulic shock regarding a valve-less electro-hydraulic servo steering device for ships

  • Jian, Liao;Lin, He;Rongwu, Xu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.4
    • /
    • pp.318-326
    • /
    • 2015
  • A valve-less electro-hydraulic servo steering device (short: VSSD) for ships was chosen as a study object, and its mathematic model of hydraulic shock was established on the basis of flow properties and force balance of each component. The influence of system structure parameters, changing rate of motor speed and external load on hydraulic shock strength was simulated by the method of numerical simulation. Experiment was designed to test the hydraulic shock mathematic model of VSSD. Experiment results verified the correctness of the model, and the model provided a correct theoretical method for the calculation and control of hydraulic shock of valve-less electro-hydraulic servo steering device.

Control of Rotational Angular Speed using Magneto-rheological Fluid (자기유변유체를 이용한 회전 각속력 제어)

  • 신성철;정재성;김정훈;이종원
    • The Korean Journal of Rheology
    • /
    • v.11 no.2
    • /
    • pp.67-72
    • /
    • 1999
  • A magneto-rheological(MR) fluid based rotary loading and braking device is developed. The loading and braking forces of the device are accurately adjustable by controlling the yield stress of MR fluid, so that the vibration control, the precision position control and the speed control of rotating machines equipped with the device can be achieved. As an engineering application, constant rotational speed regulation is conducted using the device manufactured in laboratory, introducing PI control action not only with varying torque due to gravitation, with initial angular speed, but also with constant external torque made by hand. To do this, first, mathematical model was obtained via experiments. And then, simulation was carried out, based on the experimentally identified model. Its result was confirmed through experiment. It is identified by simulation and experimental results that PI action leads to satisfactory control performance in both cases that varying torque due to gravitation, with initial angular speed, and constant external torque are applied.

  • PDF