• Title/Summary/Keyword: Fluid Capacity

Search Result 567, Processing Time 0.025 seconds

Effects of supersonic condensing nozzle flow on oblique shock wave (超音速 노즐흐름에 있어서 凝縮이 傾斜衝擊波에 미치는 影響)

  • 강창수;권순범
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.3
    • /
    • pp.547-553
    • /
    • 1989
  • Last several stages of high capacity fossil power steam turbine and most stages of nuclear power steam turbine operate on wet steam. As a consequence, the flows in those cascades are accompanied by condensation, and the latent heat caused by condensation affects an oblique shock wave being generated at the vicinity of trailing of the blade. In the case of expanding of moist air through a suction type indraft wind tunnel, the effect of condensation affection the oblique shock wave generated by placing the small wedge into the supersonic part of the nozzle was investigated experimentally. In these connections, the relationship between condensation zone and reflection point of the incident oblique shock wave, angle between wedge bottom wall and oblique shock wave, and the variations of angles of incident and reflected shock waves due to the variation of initial stagnation relative humidity are discussed. Furthermore, the relationship between initial stagnation relative humidity and load working on the nozzle wall, obtained by measuring static pressure at the nozzle centerline, is discussed.

The development and Performance test of the Cook Top type Gas valve for the slim-line style Gas Range (슬림라인형 가스레인지용 쿡탑형 가스 밸브의 개발과 작동 성능 검증)

  • Kim, Sang-Ju;Lee, Sang-Cheol;Ju, Kwang-Myung;Lee, Han-Jong;Chang, In-Bae
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.568-572
    • /
    • 2003
  • The height of valve body is limited to 30mm in the cook-top style gas valves for the domestic gas ranges. But the all the safety specifications of KS should be fulfilled and the magnetic power unit(MPU) should be installed in the valve body for the safety reason. The length of MPU body is longer than the 30mm that it should be located in the square direction of the knob shaft and therefore the implementation of the lever mechanism to transmit the press motion of the knob to the MPU valve is very difficult. In this paper, the hinged lever with inclined plate is used to transmit the press motion of the knob to the MPU valve. The analysis of the gas flow with using the commercial software of FLOW-3D shows that the gas flow capacity is fit for the domestic gas range. The performance and responsibility of the valve is tested for the mass production and the test results shows that the valve can be installed in the commercial gas range.

  • PDF

Erosion Characteristics of Kaolinite with respect to Contents of Silt (실트함량에 따른 카올리나이트의 침식특성 평가)

  • Lee, Ju-Hyung;Park, Jae-Hyun;Chung, Mun-Kyung;Kwak, Ki-Seok
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.593-596
    • /
    • 2008
  • The scour phenomenon involves the erosive potential of flowing water and the relative ability of the soil to resist erosion. The scour phenomenon in cohesive soils is much different from that in non-cohesive soils. Granular soils resist erosion by their buoyant weight and the friction between the particles. The soil particles are dislodged individually from the bed under the action of the eroding fluid. Scour in cohesive soils is much slower and more dependent on soil properties than that in non-cohesive soils. Therefore the analysis models for estimating erosion characteristics of cohesive soils should consider not only flowing water but also the relative ability of the soil to resist erosion. In this study, erosion characteristics for the clay-silt mixed soil will be analyzed as a fundamental study for development of bridge scour analysis and design system considering scour resistance capacity of a soil. For this analysis, the relationship between scour characteristics and soil properties was evaluated through scour rate test with Kaolinite samples remolded using various loading and contents of silt.

  • PDF

Experimental Quality Characteristics for Water Removal in Inner Flushing Oil in Process Piping of Offshore Plant (해양플랜트 프로세스 배관 내경 플러싱 오일속에서 수분제거를 위한 실험적 품질 특성)

  • Park, Chang-Soo;Sung, Ki-Young;Han, Seong Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.797-805
    • /
    • 2019
  • An important problem of offshore plant process piping is equipment accidents due to the removal of fine metal debris and foreign substances in the pipes that deliver fluids such as hydraulic oil, lubricating oil and thermal oil. Temporary flushing equipment to remove debris uses fluid equipment of centrifugal pump and gear pump to prevent equipment accident of offshore platform. The equipment manufacturer requires the shipyard to have a cleanliness rating inside the pipe to meet the international standards ISO4406 and NAS1638 quality levels to prevent damage to the equipment sold. The quality of the internal flushing of pipes conforms to the regulations suggested by the equipment manufacturer. In this paper, three types of electric heater capacity, which is a method of evaporating and removing water inside a pipe during an oil flushing process, were compared. In addition, the study was conducted to remove the flushing oil in the pipe and to improve oil quality.

Effects on TMR and Airflow in HDD Cavity due to Disk Damper Shapes (디스크 댐퍼 현상이 HDD 내부 유동 및 TMR에 미치는 영향)

  • Um, Yo-Han;Rhim, Yoon-Chul
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.32-37
    • /
    • 2006
  • The recording density of a hard disk drive(HDD) has been increased so rapidly that the storage capacity of a commercial HDD for the personal computer already reaches several hundred giga-bytes recently. Many technologies related to the HDD, such as servo, media, actuator dynamics, thermo and fluid dynamics, etc. must be developed together to realize higher recording density. Especially, airflow inside the HDD cavity has been concerned as the rotational speed of the disk increases. Typical problem due to the airflow is the off-track vibration of a head stack assembly(HSA) as the airflow collides with the E-block, suspensions, and sliders, i.e., the flow induced vibration(FIV). This problem is one of the most significant sources of the track mis-registration(TMR) so that it must be resolved. In this study, disk damper shape is modified to minimize the influence of airflow on the HSA. Modified disk dampers, which change the flow field of the inside cavity of a HDD, show good effects not only on the disk vibration but also on the off-track vibration of a HSA. Vibrations of E-block and slider have been measured with LDV and the airflow field inside the HDD cavity has been analyzed with commercial CFD program to verify these effects.

  • PDF

Numerical Predictions of Heat Transfer in the Fluidized Bed Heat Exchanger

  • Ahn, Soo-Whan
    • Journal of agriculture & life science
    • /
    • v.44 no.4
    • /
    • pp.29-43
    • /
    • 2010
  • The numerical analysis by using CFX 11.0 commercial code was done for proper design of the heat exchanger. The present experimental studies were also conducted to investigate the effects of circulating solid particles on the characteristics of fluid flow, heat transfer and cleaning effect in the fluidized bed vertical shell and tube type heat exchanger with counterflow, at which a variety of solid particles such as glass ($3mm{\Phi}$), aluminum ($2{\sim}3mm{\Phi}$), steel ($2{\sim}2.5mm{\Phi}$), copper ($2.5mm{\Phi}$) and sand ($2{\sim}4mm{\Phi}$) were used in the fluidized bed with a smooth tube. Seven different solid particles have the same volume, and the effects of various parameters such as water flow rates, particle diameter, materials and geometry were investigated. The present experimental and numerical results showed that the flow velocity range for collision of particles to the tube wall was higher with heavier density solid particles, and the increase in heat transfer was in the order of sand, copper, steel, aluminum, and glass. This behavior might be attributed to the parameters such as surface roughness or particle heat capacity.

Performance Comparison of Liquid-Cooling with Air-Cooling Heat Exchangers Designed for Telecommunication Equipment

  • Jeon, Jong-Ug;Choi, Jong-Min;Heo, Jae-Hyeok;Kang, Hoon;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.2
    • /
    • pp.64-69
    • /
    • 2008
  • Electronic and telecommunication industries are constantly striving towards miniaturization of electronic devices. Miniaturization of chips creates extra space on PCBs that can be populated with additional components, which decreases the heat transfer surface area and generates very high heat flux. Even though an air-cooling technology for telecommunication equipment has been developed in accordance with rapid growth in electrical industry, it is confronted with the limitation of cooling capacity due to the rapid increase of heat density. In this study, liquid-cooling heat exchangers were designed and tested by varying geometry and operating conditions. In addition, air-cooling heat exchangers were tested to provide performance data for the comparison with the liquid-cooling heat exchangers. The liquid-cooling heat exchangers had twelve rectangular channels with different flow paths of 1, 2, and 12. Silicon rubber heaters were used to control the heat load to the heat exchangers. Heat input ranged from 293 to 800W, and inlet temperatures of working fluid varied from 15 to $27^{\circ}C$. The heat transfer coefficients were strongly affected by flow conditions. All liquid-cooling heat exchangers showed higher cooling performance than the air-cooling heat exchanger. The heat exchanger with 2-paths could provide more controllability on the maximum temperature than the others.

Development of Nanofluidic Thermosyphon Heat Sink (나노유체를 이용한 열사이폰 히트싱크)

  • Rhi Seok-Ho;Shin Dong-Ryun;Lim Taek-Kyu;Lee Chung-Gu;Park Gi-Ho;Lee Wook-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.10
    • /
    • pp.826-834
    • /
    • 2006
  • A heat sink system using nanofluidic thermosyphon for electronics systems was studied. The experimental results indicate that a cooling capacity of up to 150 W at an overall temperature difference of $50^{\circ}C$ can be attainable. The heat sink design program also showed that a computer simulation can predict the most of the parameters involved. In the experimental study, the volume concentration of nano particles affect the system performance. Nanofluidic thermosyphon with 0.5% volume concentration showed the best performance. Nanofluid can increase CHF of the system compared with water as a working fluid. The current simulation results were close to the experimental results in acceptable range. The simulation study showed that the design program can be a good tool to predict the effects of various parameters involved in the optimum design of the heat sink.

A Study of Application on the Pulsating Heat Pipe for Heat Transfer Enhancement of Metal Hydride Alloy (수소 저장합금층의 열전달 촉진을 위한 진동형 히트 파이프 적용에 관한 연구)

  • Lee, Min-Jae;Im, Yong-Bin;Bae, Sang-Chul;Kim, Jong-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.346-351
    • /
    • 2006
  • When metallic alloys are reacted to hydrogen, heat transfer of storage tank effects hydrogen storage rate and capacity. If pulsating heat pipe are used to improve heat transfer efficiency, production of hydrogen storage tank can be more simple and economical. Experiment of heat pipe was conducted by varying working fluids and heat flux. According to supply heat flux, test indicate that R-22 and R-l42b were found lower temperature difference between evaporator and condenser than R-134a and Ethanol. Thermal resistances of R-22 and R-142b were also lower than others. Using R-142b as a working fluid, heat pipe type hydrogen storage tank is tested in absorption and desorption processes.

  • PDF

Changes in Antioxidant Activity and Total Phenolic Content of Water Spinach (Ipomoea aquatic Forsk.) under In Vitro Biomimicking System

  • Lee, A-Young;Kim, Young-Suk;Shim, Soon-Mi
    • Food Engineering Progress
    • /
    • v.14 no.4
    • /
    • pp.342-345
    • /
    • 2010
  • The purpose of current study was to examine bioaccessibility of antioxidant activity and total phenolic content in each part of water spinach (Ipomoea aquatic Forsk.). In vitro biomimicking system simulated human digestive fluid was employed in order to measure bioavailable anti-oxidative effect and phenolic content. Antioxidant activity and total phenolic content was measured by using the DPPH method and the Folin-Ciocalteu assay, respectively. Stem of water spinach had a higher DPPH free radical scavenging effect (5.43 mg/mL for $IC_{50}$) than leaf (5.95 mg/mL for $IC_{50}$), while leaf had a greater level of total phenolic content (287.45 ${\mu}g$ GAE/mL) than stem (216.45 ${\mu}g$ GAE/mL). Bioaccessible antioxidant capacity and digestive stability of total phenolic content showed a similar pattern to what found in raw materials. Our result also indicated that total phenolic content was not found to be a major marker for prediction of antioxidant activity. It is plausible that other constituents such as vitamin E and C in water spinach could be contributors for antioxidant activities.