• Title/Summary/Keyword: Flowing particles

Search Result 96, Processing Time 0.028 seconds

Flow Characteristics of Dispersive ER Fluid Clearance between ER-Valve (ER-Valve 간극내에서 분산계 ER유체의 유동특성)

  • 장성철;염만오;이종두;장성수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1123-1126
    • /
    • 2003
  • In this research 4 plate type ER-Valves which have same surface but different width and length are designed and an experimental apparatus is constructed. With this experimental apparatus, flow rate and pressure drop of ER fluid flowing in ER-Valve are measured by varying electric field strength of ER-valve, and relation between valve types and pressure drop is also experimented. ER fluid is made silicon oil mixed with 40wt% starch having hydrous particles. The pressure drop according to the strength of electric field by differential pressure gauge in the present ER-Valve was used. This test reviewed experiment for the special changes of ER fluids in the steady flow condition.

  • PDF

Preparation and Evaluation of the Controlled-release Dosage Form of Amoxicillin (제어방출형 Amoxicillin제제의 제조 및 평가)

  • Jee, Ung-Kil;Jeon, Un-Jong;Lee, Gye-Won;Han, Kun;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.167-176
    • /
    • 1994
  • The microcapsules of amoxicillin using stearyl alcohol and polyethyleneglycol 8000 (PEG 8000) were prepared by a emulsion melted-cooled process in water phase. The size distribution, dissolution test, observation with SEM and in vivo test were investigated. The microcapsules obtained were spherical, uniform and free flowing particles. The release of drug from microcapsule was increased in proportional to the content of PEG 8000. As the PEG 8000 content increased, the particle size of microcapsule was decreased. Sanning electron micrograph study revealed that microcapsules had comparatively rough surfaces as drug content was increased. The $AUC_{0-12}$ after administration of amoxicillin microcapsules was more increased 40% as compared with the AUC after administration of amoxicillin powder in rabbits.

  • PDF

Experimental Study on the Discharge Electrode of A Two-Stage Electrostatic Air Cleaner (2단 평행판 전기집진기의 방전부 특성 실험)

  • Kim, I.S.;Lee, J.O.;Kim, Y.J.;Choi, H.O.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.1
    • /
    • pp.27-34
    • /
    • 1993
  • The two-stage electrostatic air cleaner is a particle control device that uses electrical forces to move particles in the flowing gas stream onto collector plates. Despite a general understanding of electrostatic air cleaner operation and their successful use in industry, many questions regarding flow, electric fields and particle collection have remained unanswered. In this paper, an experimental investigation for designing the discharge electrode, including ionizer wire diameter, plate length and wire-to-plate spacing, is carried out. The electrical conditions, namely the electric field intensity, the space current and the particle charge intensity, in wire-plate electrostatic air cleaner are reported and examined.

  • PDF

Preparation of Substained-Release Microspheres of Phenylpropanolamine HCI and Their Release Characteristics

  • Kim, Chong-Kook;Lee, Kyung-Mi;Hwang, Sung-Joo;Yoon, Yong-Sang
    • Archives of Pharmacal Research
    • /
    • v.13 no.4
    • /
    • pp.293-297
    • /
    • 1990
  • Sustained release microspheres containing phenylpropanolamine HCI (PPA) were prepared with acrylic polymer (Eudragit RL/RS) sand hydroxypropylmethylcellulose phthalate (HPMCP) using a emulsion-solvent evaporation method. Magnesium strate was used a smoothing agent for preparation of microspheres. The microspheres obtained were very spherical and free-flowing particles. Scanning electron microscopy showed that microspheres have a smooth surface and a sponage-like internal structure. The dissolution rate of PPA from the microspheres was dependent on the pH of dissolution media. PPA showed faster relase in hP 1. 2 solution than in pH 7.4 solution due to the solubility of PPA. Therefore we prepared new microspheres containing 5% (w/v) HPMCP in order to control the release of PPA. The release rate of PPA from these new microspheres was similar in pH 1.2 and pH 7.4 solution.

  • PDF

Flow Analysis of the Rotating Sludge Suction Collector by Numerical Simulation (수치시뮬레이션을 이용한 흡입식 슬러지 수집기의 유동해석)

  • Suh, Sang-Ho;Roh, Hyung-Woon;Byun, Jong-Youn
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.5 s.38
    • /
    • pp.22-27
    • /
    • 2006
  • Sedimentation phenomenon of suspended solids occurs by the gravitational force. Pollution particles are separated from slowly flowing waste water in clarifier. Recently, the sludge suction collector is Preferred rather than the scraper type sludge collector due to the enhancement of the clarifier efficiency. The sludge suction collector is usually operated by the user's experiences without any scientific and/or technical consideration. To evaluate the performance of sludge suction collector, the three dimensional numerical simulation was conducted by the finite volume method. To analyze the performance, the velocity vectors and the suction flow rates of the orifices were investigated. The result showed that each suction flow rate through out the collector was equivalent in the sludge suction collector and the efficiency of suction collector was good to remove high concentrated sludge in clarifier.

Variation of Flow Characteristics in the Rotating Suction Sludge Collector (흡입식 슬러지 수집기가 회전할 때의 유동특성 변화)

  • Jin, Hee-Nam;Byun, Jong-Youn;Roh, Hyung-Woon;Suh, Sang-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1851-1856
    • /
    • 2004
  • Sedimentation phenomenon of suspended solids occurs by the gravitational force. Pollution particles are separated from slowly flowing wastewater in clarifier. Recently, the sludge suction collector is preferred rather than the scraper type sludge collector due to enhancement of the clarifier efficiency. The sludge suction collector is usually operated by the user's experiences without any scientific and/or technical consideration. To evaluate the performance of sludge suction collector, the three dimensional computer simulation was conducted by the finite volume method. To analyze the performance, the velocity vectors and the suction flow rates of the orifices were investigated. The result showed that each suction flow rate through out the collector was equivalent in the sludge suction collector and the efficiency of suction collector was good to remove high concentrated sludge in clarifier.

  • PDF

Performance Analysis for Sludge Suction Collector in Clarifier (침전지의 흡입식 슬러지 수집기에 대한 성능해석)

  • Jin, Hee-Nam;Byun, Jong-Youn;Suh, Sang-Ho;Roh, Hyung-Woon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.415-420
    • /
    • 2003
  • Sedimentation phenomenon of suspended solids occurs by the gravitational force. Pollution particles are separated from slowly flowing wastewater in clarifier. Recently, the sludge suction collector is preferred rather than the scraper type sludge collector due to enhancement of the clarifier efficiency. The sludge suction collector is usually operated by the user's experiences without any scientific and/or technical consideration. To evaluate the performance of sludge suction collector, the three dimensional computer simulation was conducted by the finite volume method. To analyze the performance, the velocity vectors and the suction flow rates of the orifices were investigated. The result showed that each suction flow rate through out the collector was equivalent in the sludge suction collector and the efficiency of suction collector was good to remove high concentrated sludge in clarifier.

  • PDF

A Study of Reduced and Carburized Reactions in Dry-milled $WO_3+Co_3O_4+C$ Mixed Powders with Different Carbon Content

  • Im, Hoo-Soon;Lee, Wan-Jae
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.648-649
    • /
    • 2006
  • The dry-milling technique was used for mixing and crushing oxides and graphite powders. The ratio of ball-to-powder was 30:1 and argon gas was filled in jar. The excess carbon was $10{\sim}20wt%$ of the stoichiometric amount. The dry-milling was carried for 20 hours. The mixed powders were reduced and carburized at $900{\sim}980^{\circ}C$ for 3 hours flowing Ar gas in tube furnace. The dry-milled powders showed the wide diffraction patterns of X-ray. The reactions of reduction and carburization were completed in 3 hours at $980^{\circ}C$. After the reactions, the mean size of WC particles was about 200 nm. The content of free carbon in WC/Co mixed powders was less as the reaction temperature increased.

  • PDF

Effects of Aluminum Tristearate in the Preparation of Sustained Release Ethambutol Hydrochloride Microcapsules (지속 방출형 염산에탐부톨 마이크로캅셀의 제조에 있어서 스테아린산알루미늄의 효과)

  • Yoo, Bong-Shin
    • Journal of Pharmaceutical Investigation
    • /
    • v.18 no.4
    • /
    • pp.175-180
    • /
    • 1988
  • The role and effect of aluminum tristearate in microencapsulation were investigated based on the dispersion system of ethambutol hydrochloride in acetone-liquid paraffin. Eudragit RS was used as a wall-forming material. Eudragit RS microcapsules prepared using aluminum tristearate were uniform, free-flowing particles. The phase diagram of ethambutol hydrochloride-Eudragit RS-aluminum tristearate indicated that spherical microcapsules ranging from 250 to 1400 ${\mu}m$ in diameter could be prepared only in a very limited region. Instrumental analysis using an energy dispersive-type X-ray microanalyser and a scanning electron microscope showed that aluminum tristearate was localized near the surface of microcapsules. From these results, it was presumed that aluminum tristearate reduced the phase tension between Eudragit microcapsules and liquid paraffin. The dissolution rates of ethambutol hydrochloride from Eudragit RS microcapsules were consideraly lower than those from ethambutol hydrochloride powders and decreased as the amount of aluminum tristearate decreased.

  • PDF

Data Visualization of Site-Specific Underground Sounds

  • Tae-Eun, Kim
    • International journal of advanced smart convergence
    • /
    • v.13 no.1
    • /
    • pp.77-84
    • /
    • 2024
  • This study delves into the subtle sounds emanating from beneath the earth's surface to unveil hidden messages and the movements of life. It transforms these acoustic phenomena into digital data and reimagines them as visual elements. By employing Sismophone microphones and utilizing the FFT function in p5.js, it analyzes the intricate frequency components of subterranean sounds and translates them into various visual elements, including 3D geometric shapes, flowing lines, and moving particles. This project is grounded in the sounds recorded in diverse 'spaces of death,' ranging from the tombs of Joseon Dynasty officials to abandoned areas in modern cities. We leverage the power of sound to transcend space and time, conveying the concealed narratives and messages of forgotten places .Through the visualization of these sounds, this research blurs the boundaries between 'death' and 'life,' 'past' and 'present,' aiming to explore new forms of artistic expression and broaden perceptions through the sensory connection between sound and vision.