• Title/Summary/Keyword: Flow-chart

Search Result 261, Processing Time 0.026 seconds

Development of KD- Propeller Series using a New Blade Section (새로운 날개단면을 이용한 KD-프로펠러 씨리즈 개발)

  • J.T. Lee;M.C. Kim;J.W. Ahn;H.C. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.2
    • /
    • pp.52-68
    • /
    • 1991
  • A new propeller series is developed using the newly developed blade section(KH18 section) which behaves better cavitation characteristics and higher lift-drag ratio at wide range of angle-of-attack. The pitch and camber distributions are disigned in order to have the same radial and chordwise loading distribution with the selected circumferentially averaged wake input. Since the geometries of the series propeller, such as chord length, thickness, skew and rate distribations, are selected by regression of the recent full scale propeller geometric data, the performance prediction of a propeller at preliminary design stage can be mure realistic. Number of blades of the series propellers is 4 and the expanded blade area ratios are 0.3, 0.45, 0.6 and 0.75. Mean pitch ratios are selected as 0.5, 0.65, 0.8, 0.75 and 1.1 for each expanded area ratio. The new propeller series is composed of 20 propellers and is named as KD(KRISO-DAEWOO) propeller series. Propeller open water tests are performed at the experimental towing tank, and the cavitation observation tests and fluctuating pressure measurements are carried out at the cavitation tunnel of KRISO. $B_{P}-\delta$ curves, which can be used to select the optimum propeller diameter at the preliminary design stage, are derived from a regression analysis of the propeller often water test results. The KD-cavitation chart is derived from the cavitation observation test results by choosing the local maximum lift coefficient and the local cavitation number as parameters. The caviy extent of a propeller can be predicted more accurately by using the KD-cavitation chart at a preliminary design stage, since it is derived from the results of the cavitation observation tests in the selected ship's wake, whereas the existing cavitation charts, such as the Burrill's cavitation chart, are derived from the test results in uniform flow.

  • PDF

Designing of Block-Type Puzzle Assembly Robot Education System without Computer (언플러그드 블록형 퍼즐 조립 로봇교육 시스템 설계)

  • Song, Jeong-Beom
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.4
    • /
    • pp.183-190
    • /
    • 2013
  • Many researchers in the 21st century has found that robot education is effective to develop the learners' creativity and problem-solving ability. However, the robot education can only be applied to the students whose computer skills are high. Also it can be taught in the well-prepared computer classroom. Students have to learn machine language to control their robots, and robots are controlled by different types of software. Therefore this study has constructed command-based programming blocks to do a robot programming without computers. It also presents a prototype of the programming process and a technological method to combine the command and the programming blocks. We used the blocks which are similar with something in flow chart: to support intuition, and to help students transfer what they learned. And types of blocks and details are described for the Robot Programing Education. Combination of command blocks is made by RS-485 connection method and, it is designed to intercommunicate with connected blocks. It also presents a prototypes: of the programming process using designed command blocks, and of the possibility of Unplugged Robot Education System.

Qualitative Analysis of Patents Concerning Cathode Active Materials for Lithium-Ion Secondary Batteries Based on Layer Structure (층상구조기반의 리튬이차전지용 양극 활물질에 관한 특허정성분석)

  • Kim, Byung-Nam;Lim, Yong-Hwan;Lee, Chul-Tae
    • Applied Chemistry for Engineering
    • /
    • v.26 no.3
    • /
    • pp.294-305
    • /
    • 2015
  • We have quantitatively analyzed 1,294 effective patents on "Quantitative Analysis of Patents Concerning Cathode Active Materials for Lithium-Ion Secondary Batteries Based on Layer Structure" from Korea, USA, Japan, Europe and PCT (WO). The importance of technological and patent values of the aforesaid patents were evaluated by the factors shown in Table 1, and 104 major and 20 core patents were selected in compliance with the evaluation from the patents. The technological flow chart over time regarding the selected major and core patents was prepared, and the applying time and development process of patents, as well as the position of core patents were established on the time scale investigated. Finally, the differentiation plans and patent avoidance strategies for the next technology development, in comparison with the technologies of patents already applied and registered, were suggested.

Reengineering of the Data Collection Process for Discharge Abstract Database (퇴원환자 진료정보 DB의 데이터 수집 과정 재설계)

  • Hong, Joon Hyun;Choi, Kwisook;Lee, Eun Mee
    • Quality Improvement in Health Care
    • /
    • v.7 no.1
    • /
    • pp.106-116
    • /
    • 2000
  • Background : Severance Hospital is an university hospital which has 1,580 beds. A LAN system was installed in the Medical Record Department in 1992 and discharge abstract data have been added to the discharge abstract database(DB) The previous work flow in the Medical Record Department had 5 levels: 1) chart collection from wards, 2) assembling, 3) abstracting data from medical record on worksheet by 2 RRAs, 4) checking deficiencies and coding diagnosis and procedures by 4 RRAs, 5) inputting the data into the discharge abstract data base by 1 RRA. The average processing time took 19.3 days from the patient discharge date. It had the production of monthly statistical report delayed. Besides, it caused the users in the hospital to complain. Methods : A CQI team was organized to find a way to shorten the processing time less than 10 days. The team identified the factors making the processing time long and integrated three levels from the 3rd level into one. Each of 7 RRAs performed the integrated level on her workstation instead of taking one of three separate levels. The comparison of processing time before and after the changes was made with 3'846 discharges of April, 1999 and 4,189 discharges of August, 1999. Results : The average processing time was shortened from 19.3 days to 8.7 days. Especially the integrated level took only 3.6 days, compared with 12.3 days before the change. The percentage of finishing up the whole processing within 10 days from discharge was increased up to 77.6%, which was 2.4% before the integration. The prevalence of error in data input was not increased in the new method. Conclusions : The integrated processing method has the following advantages: 1) the expedition of production of monthly statistical report, 2) the increase of utilizing rate of dischare abstract data by Billing Dept, Emergency Room, QI Dept., etc., 3) the improvement of intradepartmental work follow, 4) the enhancement of medical record quality by checking the deficiencies earlier than before.

  • PDF

An Examination of an Efficient UI of Smartphone Home Screen Structure (스마트폰의 홈 화면구조에 따른 효율적 UI 방안 모색)

  • Choi, Jinhae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.437-446
    • /
    • 2017
  • Objective: This study aims to draw an efficient UI design by comparing the usability of App drawer and single-layered home screens, which are smartphone home screens. Background: Because smartphone home screen is frequently used including the installation, deletion, and editing of APPs, it should be designed with easily controllable information structure. There is a need to seek a user-friendly UI by comparing the usability of App drawer and single-layered home screens, of which methods to search Apps are different. There is also a need to examine an efficient UI and the factors to improve from the user perspective. Method: This study targeted 30 Android OS and iOS users to evaluate the App drawer and single-layered home screens, of which UI structures are different. Each participant was instructed to carry out an App searching task and App deleting task, and the execution time and the number of errors were measured. After the tasks were completed, they evaluated satisfaction through a questionnaire survey. Results: In the App searching task with low task level, there was no difference in execution level between the App drawer and single-layered home screens. However, the single-layered home screen showed higher efficiency and accuracy in the App deleting task with high task level. As for the group difference according to use experience, there was no difference in satisfaction among Android OS users, but iOS user satisfaction with single-layered home screen with which they were familiar was higher. Conclusion: As for home screen usability, the single-layered home screen UI structure can be advantageous, as task level is higher. Repulsion was higher, when users, who had used easier UI, used complex UI in comparison with user satisfaction, when users familiar with complex UI used easier UI. A UI indicating the current status with clear label marking through a task flow chart-based analysis, and a UI in which a user can immediately recognize by exposing hidden functions to the first depth were revealed as things to improve. Application: The results of this study are expected to be used as reference data in designing smartphone home screens. Especially, when iOS users use Android OS, the results are presumed to contribute to the reduction of predicted barriers.

A Study on Life-Cycle Environmental Impact of Synthetic Resin Formwork (합성수지 거푸집의 전과정 환경영향평가에 관한 연구)

  • Nam, Kyung-Yong;Yang, Keun-Hyeok;Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.245-252
    • /
    • 2020
  • Synthetic resin formwork is made of lightweight high-density polyethylene(HDPE). This study used a process flow chart that satisfies the system boundary (such as Cradle-to- Product shipmen ) required by ISO FDIS 13352 to evaluate the entire process of synthetic resin foam using. The entire life cycle inventory (LCI) database calculated from input energy sources, materials used, transportation methods, and manufacturing processes at the system boundary was analyzed. Based on the environmental impact assessment index methodology of the Ministry of Environment from the LCI data analysis of synthetic resin formwork, the environmental impact assessment was carried out through classification, normalization, characterization, and weighting process. The experimental results are as follows the amount of CO2 (carbon) emission considering the number of conversions was about 32% lower than that of the Euroform. This shows that the use of synthetic resin formwork reduces material production by half compared to Euroform and reduces CO2 (carbon) emissions.

Assessment Process Design for Python Programming Learning (파이선(Python) 학습을 위한 평가 프로세스 설계)

  • Ko, Eunji;Lee, Jeongmin
    • Journal of The Korean Association of Information Education
    • /
    • v.24 no.1
    • /
    • pp.117-129
    • /
    • 2020
  • The purpose of this paper is to explore ways to assess computational thinking from a formative perspective and to design a process for assessing programming learning using Python. Therefore, this study explored the computational thinking domain and analyzed research related to assessment design. Also, this study identified the areas of Python programming learning that beginners learn and the areas of computational thinking ability that can be obtained through Python learning. Through this, we designed an assessment method that provides feedback by analyzing syntax corresponding to computational thinking ability. Besides, self-assessment is possible through reflective thinking by using the flow-chart and pseudo-code to express ideas, and peer feedback is designed through code sharing and communication using community.

Evaluation of Kinetic Parameters and Thermal Stability of Melt-Quenched BixSe100-x Alloys (x≤7.5 at%) by Non-Isothermal Thermogravimetric Analysis

  • Ahmad, Mais Jamil A.;Abdul-Gader Jafar, Mousa M.;Saleh, Mahmoud H.;Shehadeh, Khawla M.;Telfah, Ahmad;Ziq, Khalil A.;Hergenroder, Roland
    • Applied Microscopy
    • /
    • v.47 no.3
    • /
    • pp.110-120
    • /
    • 2017
  • Non-isothermal thermogravimetry (TG) measurements on melt-quenched $Bi_xSe_{100-x}$ specimens (x=0, 2.5, 7.5 at%) were made at a heating rate ${\beta}=10^{\circ}C/min$ in the range $T=35^{\circ}C{\sim}950^{\circ}C$. The as-measured TG curves confirm that $Bi_xSe_{100-x}$ samples were thermally stable with minor loss at $T{\leq}400^{\circ}C$ and mass loss starts to decrease up to $600^{\circ}C$, beyond which trivial mass loss was observed. These TG curves were used to estimate molar (Se/Bi)-ratios of $Bi_xSe_{100-x}$ samples, which were not in accordance with initial composition. Shaping features of conversion curves ${\alpha}(T)-T$ of $Bi_xSe_{100-x}$ samples combined with a reliable flow chart were used to reduce kinetic mechanisms that would have caused their thermal mass loss to few nth-order reaction models of the form $f[{\alpha}(T)]{\propto}[1-{\alpha}(T)]^n$ (n=1/2, 2/3, and 1). The constructed ${\alpha}(T)-T$ and $(d{\alpha}(T)/dT)-T$ curves were analyzed using Coats-Redfern (CR) and Achar-Brindley-Sharp (ABS) kinetic formulas on basis of these model functions, but the linearity of attained plots were good in a limited ${\alpha}(T)-region$. The applicability of CR and ABS methods, with model function of kinetic reaction mechanism R0 (n=0), was notable as they gave best linear fits over much broader ${\alpha}(T)-range$.

Shear Strength of Retrofitted RC Squat Wall by Additional Boundary Element (단부 증타 보강된 RC 전단벽체의 전단강도)

  • Yi, You-Sun;Hong, Sung-Gul;Park, Young-Mi
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.5
    • /
    • pp.489-499
    • /
    • 2015
  • This study suggested shear strength prediction model for retrofitted single-layered RC squat wall by providing column element as additional boundary element. This model revised existing shear strength prediction model of shear wall to consider detail and shear deformation capacity of column by assuming the length that concentrated shear deformation of the column is occurred. It was able to suggest additional compatibility condition related to shear strain of retrofitted of retrofitted shear wall at the ultimate state by using this length. Therefore, this study proposed a flow chart for predicting shear strength of the retrofitted shear wall considering this additional condition. Moreover, this study also proposed a method for predicting initial stiffness of the retrofitted shear wall by transforming the wall's resisting mechanism against to lateral load to a single diagonal strut mechanism. The proposed methods can predict shear strength and initial stiffness of not only the retrofitted shear wall of this study, also infilled RC shear wall in RC frame.

Retrospective Study on the Flow and Characteristics of Dental Emergency Patients in Chosun University Hospital

  • Lee, Sung-Suk;Kim, Su-Gwan;Oh, Ji-Su;Moon, Seong-Yong;You, Jae-Seek;Yu, Kyoung-Hwan;Jo, Ji-Ho;Park, Jin-Sung;Yang, Wang-Sik;Seo, Dong-Kook
    • Journal of Korean Dental Science
    • /
    • v.8 no.1
    • /
    • pp.10-15
    • /
    • 2015
  • Purpose: The aim of the present study is to assess the importance of proper treatment timing for dental emergency patients by characterizing current patient care in the emergency room. Materials and Methods: A retrospective chart review of 3,211 patients who visited the Chosun University Hospital's dental emergency department (Gwangju, Korea) was conducted from January 1, 2011 to May 31, 2014. Information regarding age, gender, onset date, main causes, and diagnoses were collected and analyzed. The main causes were divided into six categories: assault, household/play, sports, traffic, work, and others. Result: Emergency visits were more common for men (69%), and the ratio of males to females was 2.2:1 On average, the major cause was household/play (49.8%), followed by others (18.9%), traffic (16.6%), assault (9.1%), sports (2.9%), and work (2.6%). The most frequent diagnosis on average was dental trauma with 82.4%, followed by infection (10.7%), others (4.7%), and bleeding (2.2%). Conclusion: The main reasons for visits to the dental emergency department are dental trauma, dental infection, bleeding, and others. The most frequent reason for dental emergency patients to visit the emergency department was dental trauma (82.4%).