• 제목/요약/키워드: Flow-3D

Search Result 3,748, Processing Time 0.03 seconds

Study on the Flow Characteristics at Natural Curved Channel by 2D and 3D Models (2·3차원 모형을 이용한 자연하도 만곡부에서의 흐름특성 연구)

  • Ahn, Seung-Seop;Jung, Do-Joon;Lee, Sang-Il;Kim, Wi-Seok
    • Journal of Environmental Science International
    • /
    • v.21 no.4
    • /
    • pp.471-478
    • /
    • 2012
  • In this study, the flow characteristic analysis at the curved-channel of the actual channel section is compared and reviewed using the 2D RMA-2 model and the 3D FLOW-3D model. the curve section with curve rate 1.044 in the research section is analyzed applying the frequency of he project flood of 100 years. According to the result, the issue for the application of the FLOW-3D Model's three-dimensional numeric analysis result to the actual river is found to be reviewed with caution. Also, application of the 3D model to the wide basin's flood characteristic is determined to be somewhat risky. But, the applicability to the hydraulic property analysis of a partial channel section and the impact analysis and forecast of hydraulic structure is presumed to be high. In addition, if the parameters to reflect the vegetation of basin and the actual channel, more accurate topological measurement data and the topological data with high closeness to the current status are provided, the result with higher reliability is considered to be drawn.

Sensitivity Analysis of Sediment Scour Model in FLOW-3D (FLOW 3D모형의 세굴 매개변수 민감도분석)

  • Yeo, Chang-Geon;Lee, Jin-Eun;Lee, Seung-Oh;Song, Jae-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1750-1754
    • /
    • 2010
  • 구조물 주변의 국부세굴에 대한 예측은 현장관측 및 수리실험 결과를 이용한 다양한 경험식과 수리모형 실험, 수치 모의 등을 통하여 이루어진다. 본 연구에서는 최근 국내에서 많이 사용되고 있는 3차원 수치모형인 FLOW-3D의 세굴분석 능력 검토를 제고하기 위하여 민감도 분석을 실시하였다. FLOW 3D의 입력 매개변수는 평균입경(Average particle diameter), 유사 비중(Density of the sediment particle), 한계 무차원 소류력(Critical Shields number), 세굴 조절개수(Scour erosion adjustment), 한계 유사비(Critical sediment fraction), 점착성 유사비(Cohesive sediment fraction), 유사 항력(sediment drag force), 안식각(Angle of repose)이 있다. 이 중에서 평균입경, 안식각, 세굴조절개수, 한계 유사 fraction 등의 매개변수에 대해 초기값을 중심으로 일정 비율로 구분하여 민감도 분석을 실시하였다. 주요 매개변수의 민감도 분석 결과는 수리실험 결과치와 비교 검토 후에 민감도의 변화 범위와 선행하여 조정할 수 있는 매개변수를 제시할 수 있다. 이러한 결과를 바탕으로 수공구조물 주변의 국부 세굴에 관한 해석시 FLOW-3D를 이용한 분석에서 보다 신뢰도 높은 결과 산출이 가능할 것으로 판단된다.

  • PDF

2D/3D image Conversion Method using Simplification of Level and Reduction of Noise for Optical Flow and Information of Edge (Optical flow의 레벨 간소화 및 노이즈 제거와 에지 정보를 이용한 2D/3D 변환 기법)

  • Han, Hyeon-Ho;Lee, Gang-Seong;Lee, Sang-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.827-833
    • /
    • 2012
  • In this paper, we propose an improved optical flow algorithm which reduces computational complexity as well as noise level. This algorithm reduces computational time by applying level simplification technique and removes noise by using eigenvectors of objects. Optical flow is one of the accurate algorithms used to generate depth information from two image frames using the vectors which track the motions of pixels. This technique, however, has disadvantage of taking very long computational time because of the pixel-based calculation and can cause some noise problems. The level simplifying technique is applied to reduce the computational time, and the noise is removed by applying optical flow only to the area of having eigenvector, then using the edge image to generate the depth information of background area. Three-dimensional images were created from two-dimensional images using the proposed method which generates the depth information first and then converts into three-dimensional image using the depth information and DIBR(Depth Image Based Rendering) technique. The error rate was obtained using the SSIM(Structural SIMilarity index).

Recovery of 3-D Motion from Time-Varying Image Flows

  • Wohn, Kwang-Yun;Jung, Soon-Ki
    • Journal of Electrical Engineering and information Science
    • /
    • v.1 no.2
    • /
    • pp.77-86
    • /
    • 1996
  • In this paper we deal with the problem of recovering 3-D motion and structure from a time-varying 2-D velocity vector field. A great deal has been done on this topic, most of which has concentrated on finding necessary and sufficient conditions for there to be a unique 3-D solution corresponding to a given 2-D motion. While previous work provides useful theoretical insight, in most situations the known algorithms have turned out to be too sensitive to be of much practical use. It appears that any robust algorithm must improve the 3-D solutions over time. As a step toward such algorithm, we present a method for recovering 3-D motion and structure from a given time-varying 2-D velocity vector field. The surface of the object in the scene is assumed to be locally planar. It is also assumed that 3-D velocity vectors are piecewise constant over three consecutive frames (or two snapshots of flow field). Our formulation relates 3-D motion and object geometry with the optical flow vector as well as its spatial and temporal derivatives. The linearization parameters, or equivalently, the first-order flow approximation (in space and time) is sufficient to recover rigid body motion and local surface structure from the local instantaneous flow field. We also demonstrate, through a sensitivity analysis carried out for synthetic and natural motions in space, that 3-D motion can be recovered reliably.

  • PDF

Development of the 3-D Bulk Motion Index for In-Cylinder Flow Induced by Induction System (I) - Based on the 3-D CFD Simulation Results - (흡기시스템을 통해 실린더로 유도되는 공기의 3차원 Bulk Motion Index 개발 (I) - 3차원 유동해석결과를 중심으로 -)

  • Yun, Jeong-Eui;Nam, Hyeon-Sik;Kim, Myung-Hwan;Min, Sun-Ki;Park, Pyeong-Wan;Kim, Ki-Seong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.11 s.254
    • /
    • pp.1057-1065
    • /
    • 2006
  • In order to figure out the physical meaning of 3-D angular flow index for in-cylinder bulk motion, CFD analysis for the swirl and tumble steady flow test rig were made using commercial package STAR-CD. Computer simulations and rig tests on some kinds of induced flow conditions were carried out. Finally, based on the comparison between the simulated results and measured results, the physical meaning of 3-D angular flow index $|\longrightarrow_{N_B}|$, $\beta$ composed of swirl and tumble coefficients measured by steady flow test rig was described.

Investigation for flow characteristics of ice-harbor type fishway installed at mid-sized streams in Korea (국내 중소하천에 설치된 아이스하버 어도 내부 흐름 특성 규명)

  • Baek, Kyong Oh;Min, Byong Jo
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.1
    • /
    • pp.33-42
    • /
    • 2022
  • In this study, flow patterns in the ice-harbor fishway were analyzed according to fluctuations of the upstream water level, an increase of weir interval, and the presence or absence of orifices using a three-dimensional commercial numerical model, Flow-3D. In order to prove the suitability of the numerical simulation results, the flow velocity and flow rate at the exit of the fishway were observed using a 3D ultrasonic velocimetry on an actual ice-harbor fishway installed downstream of the Daegok bridge in Gyeongan-Cheon. Four types of turbulence modules can be selected for the Flow-3D model. As a result of verification with observation data, the RNG model best described the flow characteristics in the ice-harbor fishway. The velocity structure in the fishway according to fluctuations of the upstream water level was simulated. The results showed that the plunging flow and the streaming flow were mixed at the lowest water level. When the water level increased about 10 cm or more from the lowest water level, the plunging flow disappeared in all pools and only the streaming flow occurred. Contrary to expectations, even when the water level is rose a little, the flow simply occurred mainly on the streaming flow. If the interval between the weirs is increased, both the plunging flow and the streaming flow are showed continued even if the water level rises. In addition, compared to the case where there are no orifices at the bottom of the weirs, the plunging flow tends to be generated in several pools. It is necessary to prevent blocking orifices through active management so that various flow patterns in the fishway can be generated in multiple pools.

3-D Groundwater Flow Analysis of Excavated Ground by Reliability Method (신뢰성기법에 의한 굴착지반에서의 3차원 지하수 흐름해석)

  • Kim, Hong-Seok;Park, Joon-Mo;Jang, Yeon-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.10
    • /
    • pp.69-76
    • /
    • 2006
  • A reliability-groundwater flow analysis is performed and the influence of flow parameters on the probability of exceeding the threshold value is examined. For this study, the 3-D numerical groundwater flow program, DGU-FLOW, is developed by extending the 2-D flow program and is coupled to the first and second order reliability program. The 3-D flow program is verified by solving the examples of groundwater flow through the underground excavation and comparing the results from commercial MODFLOW program. Reliability routine of the program is also verified by comparing the probability of failure with that of Monte-Carlo Simulation. The reliability analysis of the groundwater flow showed that the probability of failure from the first and second order reliability method are quite close to that of Monte-Carlo Simulation. from the parametric study of hydraulic conductivity of soil layers, the increase of both mean and variance of hydraulic conductivity results in the increase of probability of exceeding the threshold flow quantity. The probability of failure was more sensitive to constant head located at the end of the flow domain than the other parameters.

Measurement of Flow inside Curved Microtube Using a Digital Micro Holographic Particle Velocimetry (디지털 홀로그래픽 입자유속계를 이용한 미세곡관 내부유동 측정)

  • Kim, Seok;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.116-118
    • /
    • 2007
  • Three-dimensional (3D) velocity field information of a laminar flow in a curved micro tube of circular cross-section has been measured using a digital micro holographic particle tracking velocimetry (HPTV). The temporal evolution of instantaneous velocity field of a water flow in a curved micro tube of $100\;{\mu}\;m$ and $300\;{\mu}\;m$ in inner diameter was obtained. The 3D mean velocity field distribution was obtained quantitatively by statistical-averaging of instantaneous velocity fields. At low Dean number (De), a secondary flow was not generated in the curved tube. With increasing Dean number, the secondary flow constituted of two large-scale counter-rotating vortices was formed due to enhanced centrifugal force. To reveal the flow characteristics of high Dean numbers, trajectories of fluid particles were evaluated experimentally from the 3D velocity fields data measured by the HPTV technique. The present experimental results, especially the 3D particle trajectories, would be helpful to design and to understand the mixing phenomena in 3D curved passages of various curved micro-tubes or micro-channels.

  • PDF

A Study on PIV Measurement of Unsteady Flow around Disk caused by Slide Type Valve Quick Closing (슬라이드 밸브 급폐쇄에 따른 디스크 주위 비정상유동의 PIV계측에 관한 연구)

  • Lee, Chul-Jae;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.3
    • /
    • pp.251-256
    • /
    • 2009
  • In this research, we experimentally studied flow characteristic by applying PIV measuring techniques which could measure the point velocity of all flow field and measuring the unsteady velocity of surrounding disk generated in a short time. Time range of great velocity change following quick closing of the slide valve was within 0.1s and the cycle was presumed to be 0.12s as a result of comparison study between the result of point flow field and of existing pressure change. Also, surrounding disk flow inside the circular pipe was closed from the upper part and flow road was getting narrow and advanced to the lower part incidentally quickly there was a tendency that the size of the flow back velocity to the upper part immeadiately after the closure decreased to 4/120s and increased again. There was flow back velocity component in y/D=0.2 lower part by the influence of flow back to the upper part after complete closure and the vortex flow of 0.2D-size near y/D=0.7, x/D=-0.3 was observed.

  • PDF

Analysis of Flow in the Spillway of Flood Control Reservoir Using CFD Model (CFD 모형을 이용한 홍수조절지 여수로의 흐름해석)

  • Lee, Ho-Jin;An, Sang-Do;Jun, Kye-Won;Son, Yong-Koo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.4
    • /
    • pp.51-57
    • /
    • 2007
  • In this study, the flow in the spillway of Gun-nam flood control reservoir were simulated by using FLOW-3D model. The discharge in the overflow weir and flow stability in approach channel were investigated with the original design plan. The results show that the scale of spillway is unsuitable and the flow in approach channel is unstable. To solve this problem, therefore, the alternative design plan were formulated. The flow in the spillway were simulated with the alternative design plan. The results show that the scale of spillway is suitable and the flow in approach channel is stable.