• Title/Summary/Keyword: Flow measurement

Search Result 3,208, Processing Time 0.031 seconds

The Treatment of Domestic Wastewater by Coagulation-Crossflow Microfiltration (응집-정밀여과에 의한 도시하수의 처리)

  • Sim, Joo-Hyun;Kim, Dae-Hwan;Seo, Hyung-Joon;Chung, Sang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.581-589
    • /
    • 2005
  • Recently, membrane processes have been replacing the conventional processes for waste water treatment to produce better quality of effluent and to meet more stringent regulations because of water shortage. However, using membrane processes for water treatment has confronted with fouling and difficulty in treating dissolved organic pollutants. In this study, membrane process equipped with crossflow microfiltration is combined with coagulation process using alum and PAC to improve permeability and treatment efficiency. The effects of coagulant dosage and optimum membrane operating conditions were investigated from measurement of permeate flow, cumulative volume, total resistance, particle size, dissolved organic pollutant, dissolved aluminium and quality of effluent. Characteristic of PAC coagulation was compared with that of alum coagulation. PAC coagulation reduced membrane fouling because of forming larger particle size and increased permeate velocity and cumulative volume. Less dissolved organic pollutants and dissolved aluminum made decreasing-rate of permeate velocity being lowered. At using $0.2\;{\mu}m$ membrane, cake filtration observed. At using $0.45\;{\mu}m$ membrane, there was floc breakage due to shear stress occurred born circulating operation. It made floc size smaller than membrane pore size, which subsequently to decrease permeate velocity and to increase total resistance. The optimum coagulation dosage was $300{\pm}50\;mg/L$ for both alum and PAC. PAC coagulation was more efficiently used with $0.2\;{\mu}m$ membrane, and the highest permeate flux was in using $0.45\;{\mu}m$membrane. The greatest efficiency of treatment was as follows; turbidity 99.8%, SS 99.9%, $BOD_5$ 94.4%, $COD_{Cr}$ 95.4%, T-N 54.3%, T-P 99.8%.

Data-driven event detection method for efficient management and recovery of water distribution system man-made disasters (상수도관망 재난관리 및 복구를 위한 데이터기반 이상탐지 방법론 개발)

  • Jung, Donghwi;Ahn, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.8
    • /
    • pp.703-711
    • /
    • 2018
  • Water distribution system (WDS) pipe bursts are caused from excessive pressure, pipe aging, and ground shift from temperature change and earthquake. Prompt detection of and response to the failure event help prevent large-scale service interruption and catastrophic sinkhole generation. To that end, this study proposes a improved Western Electric Company (WECO) method to improve the detection effectiveness and efficiency of the original WECO method. The original WECO method is an univariate Statistical Process Control (SPC) technique used for identifying any non-random patterns in system output data. The improved WECO method multiples a threshold modifier (w) to each threshold of WECO sub-rules in order to control the sensitivity of anomaly detection in a water distribution network of interest. The Austin network was used to demonstrated the proposed method in which normal random and abnormal pipe flow data were generated. The best w value was identified from a sensitivity analysis, and the impact of measurement frequency (dt = 5, 10, 15 min etc.) was also investigated. The proposed method was compared to the original WECO method with respect to detection probability, false alarm rate, and averaged detection time. Finally, this study provides a set of guidelines on the use of the WECO method for real-life WDS pipe burst detection.

The Relationship between FEV1 and PEFR in the Classification of the Severity in COPD Patients (만성 폐쇄성 폐질환 환자의 중증도 분류시 FEV1과 PEFR의 연관성)

  • Shin, Sang Youl;Ho, Yoon Jae;Kim, Sun Jong;Yoo, Kwang Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.5
    • /
    • pp.507-514
    • /
    • 2005
  • Background : Measurement of the $FEV_1$ and PEFR in COPD patients is a significant indicator of the disease severity, the response to treatment and the acute exacerbation. However, it is not known if PEFR can be used to determine the severity of COPD because the agreement between PEFR and $FEV_1$ in COPD patients is not well known. Methods : From September, 2003 to August, 2004, 125 out patients with COPD who were treated at the pulmonary clinic in KonKuk University Hospital were enrolled in this study. The $FEV_1$ and PEFR of each patient were measured and all the data was analyzed using SPSS. Results : The average predicted $FEV_1$ % and PEFR % was $56.98{\pm}18.21%$ and $70{\pm}27.60%$, respectively. There was linear correlation between the predicted $FEV_1$ % and predicted PEFR %. There was no correlation between age of the COPD patients and the predicted PEFR %. There was correlation between dyspnea, which is a subjective symptom of the patients, and the predicted PEFR %. Conclusion : In COPD patients, the classification of the severity by PEFR tends to underestimate the state of the disease compared with the classification of the severity by the $FEV_1$. Therefore, the classification of the severity by PEFR should be interpreted carefully in patients with severe symptoms. Once the classification of the severity has made, the follow-up examination may use the PEFR instead of the $FEV_1$.

Development of Rating Curve for High Water Level in an Urban Stream using Monte Carlo Simulation (Monte Carlo Simulation을 이용한 도시하천의 고수위 Rating Curve 개발)

  • Kim, Jong-Suk;Yoon, Sun-Kwon;Moon, Young-Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1433-1446
    • /
    • 2013
  • In this study, we proposed a methodology to develop Rating Curves for high water level using rainfall generation by the Monte Carlo Simulation (MCS) technique, optimized rainfall-runoff model, and flood routing model in an urban stream. The developed stage discharge Rating Curve based on observed data was contained flow measurement errors and uncertainties. The standard error ($S_e$) for observations was 0.056, and the random uncertainty ($2S_{mr}$) was analyzed by ${\pm}1.43%$ on average, and up to ${\pm}4.27%$. Moreover, it was found that the Rating Curve extensions by way of logarithmic and Stevens methods were overestimated to compare with the urban basin scale. Finally, we confirmed that the high water level extension by random generation of hydrological data using MCS can be reduced uncertainty of the high water level, and it will consider as a more reliable approach for high water level extension. In the near future, this results can be applied to real-time flood alert system for urban streams through construction of the high water level extension system using MCS procedures.

Dynamic Analysis of CRM Strategy for Online Shopping-mall (온라인쇼핑몰의 CRM 전략에 관한 동태적 분석: System Dynamics 기법을 활용한 고객만족도 분석을 중심으로)

  • Kang, Jae-Won;Lim, Jay-Ick;Lee, Sang-Gun
    • Information Systems Review
    • /
    • v.9 no.3
    • /
    • pp.99-132
    • /
    • 2007
  • As customer management rises by important issue in electronic commerce, virtue study about CRM have proceeded much. However, because existent researches were positive researches of most statistical base, There are some limitation that does not show dynamic change with CRM flow by flowing of time, and can not forecast propriety and future result about CRM strategy. Therefore, in order to overcome existent limitation on these CRM study, this study designed dynamic model which draws factors that compose CRM strategy of on-line shopping mall, and do based on technique in system dynamics so that can analyze dynamic change between these factors. Concretely, atomized customer focuses in the on-line shopping mall and does based on Permission marketing theory, and applied CRM of different level to atomized customers and know change of customer satisfaction measurement and discomfort degree accordingly. According to the result of Simulation practice, situation that achieve CRM strategy of different level by atomize customer more increase the customer satisfaction than situation that is not so. Dynamic pattern that presented in this study is expected that can verify validity about CRM achievement strategy of different level at each CRM point of contact & how Internet enterprise including on-line shopping mall is establishing CRM strategy reasonably.

An Experimental Approach to Evaluate the Desulfurization Yield in Spray Drying Sorber (반건식 세정기의 산성가스 제거성능에 관한 실험적 연구)

  • Yang, Hyun-Mo;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.4
    • /
    • pp.589-598
    • /
    • 2000
  • A pilot-scale Spray Drying Sorber (SDS) system was set up to evaluate the effect of spray characteristics on the desulfurization yield. The size distribution and the Sauter Mean Diameters of slurry droplets were measured in advance using the optical size measurement system, Malvern 2600. The desulfurization yield of the drying chamber by size was measured for the conditions of inlet gas and spray injection. As a reagent, 10% limestone slurry of $Ca(OH)_2$ was treated with flue gas containing $SO_2$, and the combustion gas analyzer and gas detectors were attached to measure the $SO_2$ concentration. With a flow rate of 144 Nm3/h and a temperature range of $200{\sim}300^{\circ}C$, the experiments were performed for the Stoichiometric Ratio (SR) of 1.0 to 3.0 and droplet mean diameter of 6.5 to $34.3{\mu}m$. In case of smaller spray droplets, the desulfurization efficiency improved due to the increase of total droplet surface area, while the reduction in evaporation time reduced the contact time between the droplets and $SO_2$ gas. In some typical region of droplet diameter, this negative effect, reduction of contact time, became dominant and the desulfurization yield decreases the desulfurization yield in spite of the expansion in absorption area. These results revealed that there exists the optimal size of spray droplets for a given state, which is determined by the compromise between the total surface area of slurry droplets and the evaporation time of droplets. The measurements also indicated that the inlet temperature of flue gas changes the optimal injection condition by varying the driving force for evaporation. The results confirm that the effect of the evaporation time of slurry droplets should be considered in analyzing the desulfurization yield as well as the total surface area, for it is a significant aspect of the correlation with the capabilities of $SO_2$ absorption in wet droplets. In conclusion, the optimal condition of spray can be determined based on these results, which might be applied to design or scale-up of SDS system.

A Study on the Self-annealing Characteristics of Electroplated Copper Thin Film for DRAM Integrated Process (DRAM 집적공정 응용을 위한 전기도금법 증착 구리 박막의 자기 열처리 특성 연구)

  • Choi, Deuk-Sung;Jeong, Seung-Hyun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.3
    • /
    • pp.61-66
    • /
    • 2018
  • This research scrutinizes the self-annealing characteristics of copper used to metal interconnection for application of DRAM fabrication process. As the time goes after the copper deposited, the grain of copper is growing. It is called self-annealing. We use the electroplating method for copper deposition and estimate two kinds of electroplating chemicals having different organic additives. As the time of self-annealing is elapsed, sheet resistance decreases with logarithmic dependence of time and is finally saturated. The improvement of sheet resistance is approximately 20%. The saturation time of experimental sample is shorter than that of reference sample. We can find that self-annealing is highly efficient in grain growth of copper through the measurement of TEM analysis. The structure of copper grain is similar to the bamboo type useful for current flow. The results of thermal excursion characteristics show that the reliability of self-annealed sample is better than that of sample annealed at higher temperature. The self-annealed sample is not contained in hillock. The self-annealed samples grow until $2{\mu}m$ and develop in [100] direction more favorable for reliability.

A Study of Teachers' Pedagogical Content Knowledge about Area of Plane Figure (평면도형의 넓이 지도에 대한 교사의 PCK 분석)

  • Park, Sun Young;Kang, Wan
    • Journal of Educational Research in Mathematics
    • /
    • v.22 no.4
    • /
    • pp.495-515
    • /
    • 2012
  • This study is to diversely analyze teachers' Pedagogical Content Knowledge (PCK) regarding to the area of plane figures and discuss the consideration for the materialization of the effective class in learning the area of plane figures by identifying the improvements based on problems indicated in PCK. The subjects of inquiry are what the problems with teachers' PCK regarding to the area of plane figures are and how they can be improved. In which is the first domain of PCK, teachers need to fully understand the concept of the area and the properties and classification of the area and length, recognized the sequence structure as a subject of guidance and improve the direction which naturally connects the flow of measurement by using random units in guidance of the area. In which is the second domain of PCK, teachers need to establish understanding of the concept for the area and understanding of a formula as a subject matter object and improve the activity, discovery and research oriented class for students as a guidance method by escaping from teacher oriented expository class and calculation oriented repetitive learning. They also need to avoid the biased evaluation of using a formula and evenly evaluate whether students understand the concept of the area as a performance evaluation method. In which is the third domain of PCK, teachers need to fully understand the concept of the area rather than explanation oriented correction and fundamentally teach students about errors by suggesting the activity to explore the properties of the area and length. They also need to plan a method to reflect student's affective aspects besides a compliment and encouragement and apply this method to the class. In which is the fourth domain of PCK, teachers need to increase the use of random units by having an independent consciousness about textbooks and supplementing the activity of textbooks and restructure textbooks by suggesting problematic situations in a real life and teaching the sequence structure. Also, class groups will need to be divided into an entire group, individual group, partner group and normal group.

  • PDF

Development of the Automated Ultrasonic Testing System for Inspection of the flaw in the Socket Weldment (소켓 용접부 결함 검사용 초음파 자동 검사 장비 개발)

  • Lee, Jeong-Ki;Park, Moon-Ho;Park, Ki-Sung;Lee, Jae-Ho;Lim, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.275-281
    • /
    • 2004
  • Socket weldment used to change the flow direction of fluid nay have flaws such as lack of fusion and cracks. Liquid penetrant testing or Radiography testing have been applied as NDT methods for flaw detection of the socket weldment. But it is difficult to detect the flaw inside of the socket weldment with these methods. In order to inspect the flaws inside the socket weldment, a ultrasonic testing method is established and a ultrasonic transducer and automated ultrasonic testing system are developed for the inspection. The automated ultrasonic testing system is based on the portable personal computer and operated by the program based Windows 98 or 2000. The system has a pulser/receiver, 100MHz high speed A/D board, and basic functions of ultrasonic flaw detector using the program. For the automated testing, motion controller board of ISA interface type is developed to control the 4-axis scanner and a real time iC-scan image of the automated testing is displayed on the monitor. A flaws with the size of less than 1mm in depth are evaluated smaller than its actual site in the testing, but the flaws larger than 1mm appear larger than its actual size on the contrary. This tendency is shown to be increasing as the flaw size increases. h reliable and objective testing results are obtained with the developed system, so that it is expected that it can contribute to safety management and detection of repair position of pipe lines of nuclear power plants and chemical plants.

Aerodynamic Characteristics and Galloping Possibility of Ice Accreted Transmission Conductors by Wind Tunnel Tests (풍동실험을 통한 착빙 가공송전선의 공력 특성 측정 및 갤러핑 발생 분석)

  • Lee, Dooyoung;Goo, Jaeryang;Park, Sooman;Kim, Donghwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.79-88
    • /
    • 2017
  • In this paper, the wind tunnel test for the measurement of aerodynamic characteristics of transmission conductors with asymmetric sections is described. A single conductor model and bundled conductor models with ice accreted shapes are tested both in steady and turbulent flow, and the aerodynamic coefficients are acquired. Transmission conductor galloping is a kind of wind-induced vibration which is characterized by primarily vertical oscillation with a very low frequency and a high amplitude. It is well known that transmission conductor galloping is generally caused by moderately strong, steady winds when a transmission conductor has an asymmetric cross-section shaped by accreted ice. Galloping should be considered from the design stage of overhead lines because it can cause severe wear and fatigue damage to attachments as well as transmission conductors. It is reported that there have been normally 20 events of galloping per year in Korea, which may be followed by serious consequences in the electric power system. Therefore, this research is performed to measure aerodynamic characteristics of ice accreted transmission conductors to understand and control transmission conductor galloping so that it would help to prevent unexpected failures and reduce the maintenance costs caused by galloping.