• 제목/요약/키워드: Flow measurement

검색결과 3,195건 처리시간 0.034초

ANSI/AMCA 210 기준에 의한 대형 축류 송풍기의 성능시험 및 측정 불확도 평가 (An Estimation of Performance Test and Uncertainty of Measurement for a Large Axial-flow Fan Based on ANSI/AMCA 210 Standard)

  • 고희환;정철영;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제17권2호
    • /
    • pp.24-29
    • /
    • 2014
  • In general, a large-capacity axial flow fan is used for industrial processes or ventilation in a social overhead capital infrastructure. The main characteristics of the large axial-flow fan need a lot of electrical power consumption and operate 24 hours a day, 365 days a year. Since the large axial flow fan consumes several hundreds to thousands kW per hour, both manufacturer and consumer are struggling to select high efficiency products for saving energy and reducing operation cost. Therefore, the performance testing should be accurately conducted in experimental equipments. The performance estimation and uncertainty of measurement of the axial-flow fan gathered from the result from nozzle shaped testing equipments certified with ANSI/AMCA standard and duct shaped testing equipment under the same experimental condition. The experimental results from both facilities have maximum 17% differences in performance evaluation and uncertainty of measurement. As considering that the differences, it is doubt about the reliability of testing result. The test was repeated with the specific term during 12 months because it is important to fully reflect the real conditions and to decide the repeatability of data. The evaluation of duct type testing facilities was failed to get an uncertainty measure. Testing results were previously published. As a series of previous paper, axial fan (∅1690 mm) and duct type testing facilities were fabricated. The purpose of fabricating testing equipment was testing an uncertainty measurement under the controlled environments.

뒤시엔느 근 이영양증 환자에서 기능 수준과 측정 자세에 따른 최대호기유량, 1초간노력성호기량 및 최대기침유량의 변화 (Changes in Peak Expiratory Flow, Forced Expiratory Volume in 1 Second and Peak Cough Flow Related to Functional Level and Measurement Position in Patients With Duchenne Muscular Dystrophy)

  • 김기송;신헌석
    • 한국전문물리치료학회지
    • /
    • 제16권3호
    • /
    • pp.1-8
    • /
    • 2009
  • It is important to find the effective position for cough and sputum clearance in respiratory physical therapy. The purpose of this study was to compare the changes in peak expiratory flow (PEF), forced expiratory volume in 1 second ($FEV_1$), and peak cough flow (PCF) related to functional level and measurement position in patients with Duchenne muscular dystrophy. Twenty one subjects were classified into three functional levels, and measurements was undertaken in three different measurement positions (upright sitting, $45^{\circ}$ reclining and supine). Vitalograph PEF/FEV DIARY was used to measure PEF and $FEV_1$, and Ferraris Pocket Peak was used to measure PCF. Mixed two-way analysis of variance and Bonferroni post-hoc test were used for statistical analysis. The results of the study were as follows: 1) Significant main effects for measurement position were found. 2) PEF was the highest in upright sitting, followed by $45^{\circ}$ reclining, and supine in order. 3) $FEV_1$ in upright sitting and $45^{\circ}$ reclining were significantly greater compared with that in supine. 4) PCF in upright sitting and $45^{\circ}$ reclining were significantly greater compared with that in supine. 5) No significant main effects for functional level were found in PEF, $FEV_1$, and PCF. 6) No significant functional level by measurement position interactions were found in PEF, $FEV_1$, and PCF. Therefore, it is concluded that upright sitting and $45^{\circ}$ degree reclining positions are recommended for effective cough and sputum clearance.

  • PDF

중성자 래디오그래피를 이용한 액체금속 유동장 측정 (Measurement of Liquid-Metal Flow with a Dynamic Neutron Radiography)

  • 차재은;사이토
    • 한국가시화정보학회지
    • /
    • 제9권4호
    • /
    • pp.63-68
    • /
    • 2011
  • The flow-field of a liquid-metal system is very important for the safety analysis and the design of the steam generator of liquid-metal fast breeder reactor. Dynamic neutron radiography (DNR) is suitable for a visualization and measurement of a liquid metal flow and a two-phase flow in a metallic duct. However, the three dimensional DNR techniques is not enough to obtain the velocity information in the wide channel up to now. In this research, a high speed DNR technique was applied to visualize the heavy liquid-metal flow field in the narrow channel with the HANARO-beam facility. The images were taken with a high frame-rate neutron radiography at 250 fps and analyzed with a Particle Image Velocimetry(PIV) method. The images were compared with the results of the commercial CFX code to study the feasibility of DNR technique for the measuring the heavy liquid-metal flow field. The PIV images could discern the turbulent vortex flow in the two-dimensional narrow channel.

4밸브 직분식 디젤엔진의 SCV 개구율에 따른 흡입유동특성 (Intake Flow Characteristics with SCV Open Ratio in a 4-Valve Direct Diesel Engine)

  • 최승환;전충환;장영준;이진욱
    • 한국자동차공학회논문집
    • /
    • 제7권7호
    • /
    • pp.66-75
    • /
    • 1999
  • Many researchers have developed the measurement technique of in-cylinder flow. Recently, there are lots of studies on steady flow with different SCV geometries. In this study the flow characteristics of four-valve cylinder head were examined in a steady test rig for different SCV open ratios. Each swirl ratio of several SCV angle was quantified by swirl impulse meter and 2D-LDV measurement. The results showed that the swirl ratio was controlled between 2.3 and 3.8 based on SCV angles. The velocity distributions of in-cylinder flow field were measured by 2-D LDV test and visualized swirl and tumble flow pattern at different positions. In this engine , we found out that the swirl was dominant flow.

  • PDF

전달 시간차 방식 초음파 가스 유량계 (Development of an Ultrasonic Gas Flow Meter Using Transit Time Difference)

  • 박상국;황원호
    • 제어로봇시스템학회논문지
    • /
    • 제9권9호
    • /
    • pp.707-713
    • /
    • 2003
  • We investigate the ultrasonic gas flow meter for the measurement of gas volume quantity, which passing through pipe, using the transit time difference method. We have designed a receiving system of an ultrasonic signal and hardware system of a flow meter Also, we have designed an experimental system for the characteristic test and calibration of a gas flow meter system. We have developed an ultrasonic gas flow meter, which has a measurement uncertainty within $\pm$ 1.7 %. For the test, we have compared our system with a difference pressure type flow meter for a few months in the real field. Through the test, we have confirmed that our system have a good reliability and durability. Also, we have confirmed that our system follows very well the variation of gas volume quantity, which was measured by a difference pressure type flow meter.

반도체용 시간식 질량유량계의 특성에 관한 연구 (An experimental study of the time based mass flow controller for semiconductor industry)

  • 장영철
    • 반도체디스플레이기술학회지
    • /
    • 제7권2호
    • /
    • pp.55-58
    • /
    • 2008
  • The objective of the research is to design, manufacture and test a Mass Flow Controller(MFC) capable of measuring compressible fluid flows based on a "bucket and stop-watch"method. The basic principle is the measurement of time, where the time taken to fill and empty a bucket of known volume is measured. This method of flow measurement is a new concept when compared to a commercilized current mass flow controller. For the flow meter to be able to compete with established designs it not only must be comparable in cost and robustness, it must be very accurate and reliable as well. This device should be able to handle fluid flows in the range of 0.1ml/min to 10ml/min within an accuracy of ${\pm}$1%. A possible application for a device such as this is in electronics industry where arsenic gas is used in the production of silicon chips.

  • PDF

처리분구별 하수발생 특성 조사 - A시 O, M 처리분구 - (Investigating Wastewater Flow Characteristics - O and M Treatment Basins of A City -)

  • 황병기
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.348-356
    • /
    • 2005
  • Water quality sampling surveys and continuous measurement of flow were conducted to identify wastewater flow characteristics for representative catchment of O and M treatment basins in A city. For HS-1 station representing commercial area, wastewater flow rises in the beginning of office-working hours, moves up and down within narrow range, and lasts till office-leaving hour, and falls gradually reflecting worker's returning home. However, in HS-2 station representing residential area, wastewater flow has two peaks, which are before office-going hour and after office-leaving hour. In residential area, the flow rate of weekends is higher than that of weekdays because it reflects population, being not contributed to generate wastewater during the working hours of weekdays, stay home and produce wastewater for weekends period. To determine the priority for rehabilitation of sewer system, infiltration rate was computed by dividing infiltration flow by mean diameter and total length of sewer, and HS-1 station ranked the first.

천연가스 유량 측정에서 헬름홀츠 자유에너지를 이용한 임계유동함수 계산 (Evaluation of Critical Flow Function by Using Helmholtz Free Energy for Natural Gas Flow Measurement)

  • 하영철;허재영
    • 대한기계학회논문집B
    • /
    • 제37권12호
    • /
    • pp.1167-1173
    • /
    • 2013
  • 본 연구에서는 천연가스 유량 측정에서 2차 표준으로 사용되는 소닉노즐 뱅크 -12개 노즐 패키지로 구성-의 임계유동함수 계산 시간을 1초 이하로 단축하고자 하였다. 이를 위해 AGA 8-dc 상태방정식을 적용한 헬름홀츠 자유에너지를 유도하고 이로부터 적분 항이 없는 열역학 상태량 식을 도출하여 CFF 계산에 적용하였다. 그 결과 CFF 계산 시간이 기존 6.7초/12개에서 0.6초/12개로 크게 감소하는 것을 확인할 수 있었고 이 계산 시간은 가스 성분 수와 거의 무관함도 알 수 있었다. 또한 본 계산 결과의 정확도를 확인하기 위해 기존 CFF 국제비교연구의 결과와 비교한 결과 차이가 없음도 확인하였다.

유체-구조 연동운동 3차원 측정시스템의 성능 검증 (Performance Tests on the 3D-Flow-Structure-Interactions-Measurement System(FSIMS))

  • 도덕희;조효제;백태실;황태규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.81-89
    • /
    • 2009
  • Performance tests on the 3-Dimensional Flow-Structure-Interactions-Measurement System(FSIMS) have been carried out. Experimental data obtained by the FSIMS on a floating cylinder have been used to generate a set of artificial images. Comparisons between the data obtained by the use of the artificial images and those original experimental data have been made. Another set of artificial images have also been generated based on theoretically modulated sinusoidal motions, and comparisons between the data obtained by the use of these artificial images and the theoretical ones have been carried out. It has been verified that the FSIMS has a measurement uncertainty of 0.04-0.06mm/frame for velocity vectors and 0.002-0.01mm for the cylinder's positions.

자동차 배출가스 측정을 위한 Photoacoustic Spectroscopy Cell의 3차원 유동장 해석 (Three-Dimensional Fluid Flow Analysis of Photoacoustic Spectroscopy Cell for Measurement of Automotive Exhaust Gas)

  • 김현철;박종호
    • 한국자동차공학회논문집
    • /
    • 제11권2호
    • /
    • pp.111-118
    • /
    • 2003
  • Recently, environmental damage to urban area becomes serious problem due to the exhaust emissions by increasing the number of vehicle. Especially, exhaust emission from diesel vehicles are blown to be harmful to human health and environment. Photoacoustic Spectroscopy system is very useful technology for simultaneous and continuous measurement of the various components of the automotive exhaust gas. In this study, in order to reduce emission gases from automobile, we tried to develop the measurement system of Photoacoustic Spectroscopy. To improve performance of high sensitive Photoacoustic Spectroscopy system for automotive exhaust emissions, the shape of Photoacoustic Spectroscopy cell was optimized to use the flow analysis. And Exhaust emission data of the 1,500cc gasoline engine was fixed the working fluid. The characteristics of fluid flow for cell were analyzed by various conditions in detail.