• Title/Summary/Keyword: Flow map

Search Result 606, Processing Time 0.032 seconds

Experimental study on two-phase flow behavior inside a vertical tube evaporator under flashing phenomenon (후래시 현상을 수반하는 수직증발관내에서의 2상유동에 관한 실험적 연구)

  • 이상용;송시홍;이상호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.4
    • /
    • pp.833-846
    • /
    • 1988
  • Two-phase flow heat transfer phenomena with flash evaporation inside a vertical tube were studied experimentally. Void fractions were measured using electrical probes, and the flow patterns were identified from the output voltage signal itself. The flow pattern as well as the beat transfer rates were changing along the axial distance from the tube inlet with the system pressure. As the pressure inside the tube decreases with fixed inlet temperature, the overall heat transfer coefficient through the tube wall and the boiling heat transfer coefficient inside the tube increase whereas the condensation heat transfer coefficient outside the tube decreases. The boiling heat transfer coefficient inside the tube measured by the experiments appeared to be somewhat larger than the value obtained from the Chen's correlation. Also, the flow patterns identified from present experiments are at the larger quality region of the low pattern map based on the transition criteria of Mishima and Ishii. This may be due to the non-equilibrium flashing phenomenon occurred at the nozzle exit and the tube inlet ; this also implies that the flow pattern of the two-phase flow depends strongly on the inlet conditions.

Thruster Modeling for Underwater Vehicle with Ambient Flow Velocity and its Incoming Angle (외부 유체의 영향을 고려한 무인잠수정의 추진기 모델)

  • Kim, Jin-Hyun;Chung, Wan-Kyun
    • The Journal of Korea Robotics Society
    • /
    • v.2 no.2
    • /
    • pp.109-118
    • /
    • 2007
  • The thruster is the crucial factor of an underwater vehicle system, because it is the lowest layer in the control loop of the system. In this paper, we propose an accurate and practical thrust modeling for underwater vehicles which considers the effects of ambient flow velocity and angle. In this model, the axial flow velocity of the thruster, which is non-measurable, is represented by ambient flow velocity and propeller shaft velocity. Hence, contrary to previous models, the proposed model is practical since it uses only measurable states. Next, the whole thrust map is divided into three states according to the state of ambient flow and propeller shaft velocity, and one of the borders of the states is defined as Critical Advance Ratio (CAR). This classification explains the physical phenomenon of conventional experimental thrust maps. In addition, the effect of the incoming angle of ambient flow is analyzed, and Critical Incoming Angle (CIA) is also defined to describe the thrust force states. The proposed model is evaluated by comparing experimental data with numerical model simulation data, and it accurately covers overall flow conditions within 2N force error. The comparison results show that the new model's matching performance is significantly better than conventional models'.

  • PDF

Experimental research on flow regime and transitional criterion of slug to churn-turbulent and churn-turbulent to annular flow in rectangular channels

  • Qingche He;Liang-ming Pan;Luteng Zhang;Wangtao Xu;Meiyue Yan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.3973-3982
    • /
    • 2023
  • As for two-phase flow in rectangular channels, the flow regimes especially like churn-turbulent and annular flow are significant for the physical problem like Countercurrent Flow Limitation (CCFL). In this study, the rectangular channels with cross-sections of 4 × 66 mm, 6 × 66 mm, 8 × 66 mm are adopted to investigate the flow regimes of air-water vertical upward two phase flow under adiabatic condition. The gas and liquid superficial velocities are 0 ≤ jg ≤ 20m/s and 0.25 ≤ jf ≤ 3m/s respectively which covering bubbly to annular flow. The flow regimes are identified by random forest algorithm and the flow regime maps are obtained. As the results, the transitional void fraction from slug to churn turbulent flow fluctuate from 0.47 to 0.58 which is significantly affected by the dimensional size of channel and flow rate. Besides, the void fraction at transitional points from churn-turbulent (slug) to annular flow are 0.66-0.67, which are independent with the gap size. Furthermore, a new criteria of slug to churn-turbulent flow is established in this study. In addition, by introducing the interfacial force model, the criteria of churn-turbulent (slug) flow to annular flow is verified.

Vertical Articulation in Chemical Reaction (화학반응에 대한 수직적 연계성)

  • ImKyu Park;JongKeun Park;SeongBae Moon
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.4
    • /
    • pp.376-390
    • /
    • 2003
  • The contents of chemical reaction in the science textbooks, used by starting from elementary school to college level, were investigated how much closely connected with them. For this purpose, nineteen subjects of chemistry contents were selected and the articulation analysis, classified into 5 criteria, was carried out. The results indicated that the articulation from elementary school to middle school looked quite acceptable, but there was a big gap from middle school to high school and the articulation from high school to college exhibited a big overlap and gap. Finally, the flow map of chemical reaction was suggested.

The Heightfield Based Cartoon Liquid Simulation Using GPU (GPU를 이용한 높이맵 기반 카툰 액체 시뮬레이션)

  • Song, gi-won;Ryoo, seung-tack
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.152-156
    • /
    • 2009
  • The goal of this study is to represent heightfield-map based cartoon liquid simulation using GPU. To do this, we examine the optical and flow features of liquid. So far, NPR represent study for gas and liquid advanced in computer graphics. In this study the flow of fluid represent using a trivial algorithm using a non-physical method, and optical of liquid represent ratio of value of reflection and refraction using fresnel equation. Cartoon represent of liquid different from the existing method, that the value of reflection and refraction on the environment map. Edge detection represent jump edge of liquid. As a result, the liquid simulation could represent a cartoon.

  • PDF

Subglottic Air Pressure in Different Phonetic Context (음성학적 문맥에 따른 성문하압의 차이에 관한 연구)

  • 박상희;정옥란;석동일
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.1
    • /
    • pp.23-27
    • /
    • 2002
  • The purpose of the study is to examine differences in subglottic air pressure as a function of phonetic context. The phonetic contexts consisted of $/i:{p^h}i:{p^h}i:/,/{p^h}i:{p^h}i:/, and /{p^h}{p^h}/$. The aerodynamic and phonatory parameters are investigated in 20 female normal adults. All measurements are taken and analysed using Aerophone II voice function analyzer. The aerodynamic parameters are Peak Air Pressure(PAP) and Mean Air Pressure(MAP), and the phonatory parameters are Phonatory Flow Rate(PFR) Maximum SPL(MSPL), Phonatory SPL(PSPL), Phonatory Power (PP), Phonatory Efficiency(PE), and Phonatory $Resistance^*$ 10-5(PR). A one-way ANOVA revealed the following results. First, the aerodynamic parameters are not significantly different. Second, Peak Air Pressure(PAP) and Mean Air Pressure(MAP), as well as the phonatory parameters such as Phonatory Flow Rate(PFR) Maximum SPL(MSPL), Phonatory SPL(PSPL), and Phonatory Efficiency(PE) were significantly different. Therefore, it is advised that clinicians use only aerodynamic parameters but phonatory parameters when using Aerophone II.

  • PDF

A study on the pulse boiling occurring inside the liquid pool of a closed two-phase thermosyphon (밀폐형 2상 열사이폰의 Pool 내부 Pulse Boiling에 관한 연구)

  • Kim, Cheol-Ju;Mun, Seok-Hwan;Gang, Hwan-Guk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1254-1261
    • /
    • 1997
  • Pulse boiling, the unsteady periodic boiling phenomenon appearing in the evaporator of thermosyphons was investigated by many researchers. In the present study investigations were conducted to examine the evolution of flow patterns at the evaporator, and changes in thermodynamic state that each of liquid pool and vapor experiences through 1 cycle of pulse boiling process. For wall and liquid pool the degree of superheat for the onset of nucleation was examined. It revealed that the degree of superheat increased with the increase of pulse period, reaching to 16.5 deg.C and 23 deg.C for liquid pool and evaporator wall respectively at .tau.=80 sec. The data on flow patterns obtained through series of operation tests were plotted in the coordinates of heat flux and vapor pressure to get a regime map. Further this map could be used to figure out the conditions of pulse boiling for a thermosyphon.

Application of kriging approach for estimation of water table elevation (Kriging 기법을 이용한 지하수위 분포 추정)

  • Park, Jun-Kyung;Park, Young-Jin;Wye, Yong-Gon;Lee, Sang-Ho;Hong, Chang-Soo;Choo, Suk-Yeon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.3
    • /
    • pp.217-227
    • /
    • 2002
  • Geostatistical methods were used for the groundwater flow analysis on the ${\bigcirc}{\bigcirc}$ tunnel area. Linear regression analysis shows that the topographic elevation and ground water level of this area have very high correlation. Groundwater-level contour maps produced by ordinary kriging and cokriging have little differences in mountain areas. But, comparing two maps on the basis of an elevation contour map, a groundwater-level contour map using cokring is more accurate. Analyzing the groundwater flow on two groundwater-level contour maps, the groundwater of study area flows from the north-west mountain areas to near valleys, and from the peak of the mountain to outside areas. In the design steps, the groundwater-level distribution is reasonably considered in the tunnel construction area by cokriging approach. And, geostatistics will provide quantitative information in the unknown groundwatrer-level area.

  • PDF

An upgrade of Landslide Hazard Map with Analysis of Debris Flow using High-Quality Geospatial Information (고품질 공간정보를 이용한 토석류 분석을 통한 산사태위험지도의 갱신방안 - 춘천지역을 중심으로 -)

  • Yang, In Tae;Yu, Young Geol;Park, Kheun;Park, Jae Kook
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.4
    • /
    • pp.17-24
    • /
    • 2015
  • This study utilized high quality three-dimensional geospatial information produced by high-resolution Digital Aerial Photograph and Airborne LiDAR data in order to analyse landslides and debris flows induced by the heavy rainfall in Chuncheon area. Also, this study analysed correlation between the established landslide hazard map and the landslide factor effect and reviewed the analysis result of debris flows on the area where landslides with debris flows occurred frequently. Finally;the study proposed ways to renew the established landslide hazard map effectively and utilize the high quality three-dimensional Geospatial information on the landslide risk area.

Evaluation of Applicability of SWAT-CUP Program for Hydrologic Parameter Calibration in Hardware Watershed (Hardware 유역의 수문매개변수 보정을 위한 SWAT-CUP 프로그램의 적용성 평가)

  • Sang Min, Kim
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.3
    • /
    • pp.63-70
    • /
    • 2017
  • The purpose of this study was to calibrate the hydrologic parameters of SWAT model and analyze the daily runoff for the study watershed using SWAT-CUP. The Hardware watershed is located in Virginia, USA. The watershed area is $356.15km^2$, and the land use accounts for 73.4 % of forest and 23.2 % of pasture. Input data for the SWAT model were obtained from the digital elevation map, landuse map, soil map and others. Water flow data from 1990 to 1994 was used for calibration and from 1997 to 2005 was for validation. The SUFI-2 module of the SWAT-CUP program was used to calibrate the hydrologic parameters. The parameters were calibrated for the highly sensitive parameters presented in previous studies. The P-factor, R-factor, $R^2$, Nash-Sutcliffe efficiency (NS), and average flow were used for the goodness-of-fit measures. The applicability of the model was evaluated by sequentially increasing the number of applied parameters from 4 to 11. In this study, 10-parameter set was accepted for calibration in consideration of goodness-of-fit measures. For the calibration period, P-factor was 0.85, R-factor was 1.76, $R^2$ was 0.51 and NS was 0.49. The model was validated using the adjusted ranges of selected parameters. For the validation period, P-factor was 0.78, R-factor was 1.60, $R^2$ was 0.60 and NS was 0.57.