• 제목/요약/키워드: Flow impedance

검색결과 235건 처리시간 0.02초

전위강하법에 의한 접지임피던스 측정 시 오차요인 분석 (Analysis of error factors of the Fall-of-potential test method in measurements of grounding impedance)

  • 전병욱;이수봉;정동철;이복희;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.313-316
    • /
    • 2008
  • This paper presents the error factors of Fall-of-potential test method used in measurements of the grounding-system impedance. This test methods inherently can introduce two possible errors in the measurements of grounding-system impedance: (1) ground mutual resistance due to current flow through ground from the ground electrode to the current probe, (2) ac mutual coupling between the current test lead and the potential test lead. The errors of ground mutual resistances and ac mutual coupling are expressed by the equation in calculating grounding impedance. These equations were calculated by Matlab that is commercial tool using mathematical calculation. The results of calculation were applied to correct grounding impedance.

  • PDF

방향성 결합기 및 핀 다이오드 스위치를 이용한 10 비트 임피던스 튜너 (10-Bit Full-Coverage Impedance Tuner Using a Directional Coupler and PIN Diodes)

  • 이동규;이상효;권영우
    • 한국전자파학회논문지
    • /
    • 제18권7호
    • /
    • pp.698-703
    • /
    • 2007
  • 본 논문에서는 방향성 결합기를 이용한 새로운 형태의 임피던스 튜너를 제안하였다. 이 튜너를 signal flow graph를 이용하여 해석하였고, 이 방식은 직렬 라인의 길이 변화가 어려운 single stub 방식에 비해 구현이 용이하고 double stub 방식에 비해 넓은 튜닝 범위를 가진다. 10개의 핀 다이오드를 이용하여 제작된 튜너는 10개의 스위치가 비트 형태로 동작하면서 Smith 차트 전 영역에서 $2^{10}$개의 균일한 임피던스 분포를 가지도록 설계되었다. 제작된 튜너는 $1.8{\sim}2.2GHz$의 대역폭에서 넓은 튜닝 영역을 가지며, 반사 계수 크기는 최대 0.9까지 측정되었다. 측정된 임피던스 값을 바탕으로 load-pull 시스템을 구성하였고, 전력 소자용 트랜지스터의 최적 출력단 임피던스를 찾아내었다.

낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작 (Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection)

  • 길형준;송길목;김영석;김종민;김영진
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

선로용량 산정법을 이용한 상정사고 선택 (Contigency Ranking Technique Using Line Capacity Calculation Method)

  • 박규홍;정재길;현승범;이인용;정인학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.285-288
    • /
    • 2000
  • This paper presents a technique for contingency ranting using line capacity calculation method and outage distribution factors(LODF) which are established by generation shift distribution factors from DC load flow solutions. By using the LODF, the line flow can be calculated a ccording to the modification of base load flow if the contingency occur. To obtain contingency ranting, maximum power tansferred to the load is obtained when load impedance $Z_r$ equal to line impedance $Z_s$. ( $Z_r$/ $Z_s$=1) The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

맥동관 냉동기에서 관성관의 모델링에 관한 연구 (A study on the modeling of the inertance tube in the pulse tube refrigerator)

  • 남관우;정상권
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.153-156
    • /
    • 1999
  • In this paper, the inertance tube is modeled by the distributed impedance model. This model is verified by the analytical solutions for the long tube without the reservoir. In this model the distributed impedace effect of the inertance tube is included and mass flow rate and pressure distributions are calculated along the inertance tube for various inertance tube lengths. Mass flow rate at the inlet of the inertance tube is also calculated by this model and compared to the lumped impedance method. Mass flow rate by the distributed model shows quite different behaviors from the lumped model when the operating frequency is high and the length of the tube becomes large.

  • PDF

소형 digital computer를 이용한 대전력계통의 해석 (Analysis of Large Power System by Small Digital Computer)

  • 박영문;정재길
    • 전기의세계
    • /
    • 제23권1호
    • /
    • pp.61-68
    • /
    • 1974
  • This paper attempts to develop the algorithms and computer program for load flow solution and faults analysis of large power system by small digital computer. The Conventional methods for load flow solution and fault analysis of large power system require too much amount of computer memory space and computing time. Therefore, this paper describes the methad for reducing the computer memory space and computing time as follows. (1) Load Flow Solution; This method is to store each primitive impedance of lines along with a list of bus numbers corresponding to the both terminals of lines, and to store only nonzero element of bus admittance matrix. (2) Faults Analysis: This method is to partition a large power system into several groups of subsystems, form individual bus impedance matrix, store them in the storage, and assemble the only required portion of them to original total system by algorithm.

  • PDF

새로운 선로용량을 고려한 전력계통의 상정사고 선택 (Contigency Ranking Technique Using New Line Capacity)

  • 박규홍;조양행
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.95-98
    • /
    • 2000
  • This paper presents a technique for contingency ranking using line capacity calculation method and outage distribution factors (LODF) which are established by generation shift distribution factors from DC load flow solutions. By using the LODF, the line flow can be calculated a ccording to the modification of base load flow if the contingency occur. To obtain contingency ranking, maximum power tansferred to the load is obtained when load impedance $Z_r$ equal to line impedance $Z_s$. The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

ISO 10767-1에 기초한 유압 펌프의 유량 맥동 측정 및 정밀도 평가 (Measurement of Hydraulic Pump Flow Ripple Characteristics Based on the ISO 10767-1 and the Evaluation of the Measuring Accuracy)

  • 김지웅;강만곤;이일영
    • 유공압시스템학회논문집
    • /
    • 제4권3호
    • /
    • pp.22-27
    • /
    • 2007
  • The source flow ripple and the source impedance in hydraulic pump are characteristic values showing fluid-borne vibration characteristics decisively. We cannot measure these two characteristic values directly, but can measure them by some indirect methods. One representative indirect measuring method is ISO 10767-1. The authors constructed a hardware and a software for the measuring method based on ISO 10767-1. Through the error evaluation of the measured results, accuracy of the measuring method using ISO 10767-1 was examined in detail.

  • PDF

유동 및 음압의 변화가 천공의 임피던스에 미치는 영향 (Effects of Flow Field and Sound Pressure on the Acoustic Impedance of Perforates)

  • 이성현;이정권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.379-382
    • /
    • 2003
  • 천공요소는 자동차의 배기 소음기, 공조기의 소음기 등을 포함하는 다양한 소음계에 널리 사용된다. 일반적으로 천공요소 들은 평균 유동과 소음원이 동시에 존재하는 환경에서 사용되며, 평균 유동 및 관 내부의 음압 레벨의 변화가 천공 부근에서의 임피던스에 큰 영향을 미치게 된다. 천공요소의 임피던스의 변화는 소음기의 음향학적 특성에 영향을 미치게 되므로, 유동이나 음압 조건이 임피던스에 미치는 영향에 대한 연구가 중요하다. 본 연구에서는 정밀 계측 및 전산유체역학적 모형을 이용해 천공요소의 임피던스에 영향을 미치는 주요 세 가지 인자 - 스치는 유동, 통과하는 유동, 음압 레벨 - 들을 고려하여 임피던스를 분석하고, 그 상관관계를 밝혔다.

  • PDF

혈류의 유동이 혈관-인조혈관 접속부 혈관 내막 세포증식에 미치는 영향 (Hemodynamic Effects on Artery-Graft Anastomotic Intimal Hyperplasia)

  • 이계한
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권2호
    • /
    • pp.143-150
    • /
    • 1994
  • Wall shear rate or stress is believed to be a major hemodynamic variable influencing atherosclerosis and artery-graft anastomic intimal hyperplasia. The purpose of this study is to verify the effects of radial wall motion, artery-graft compliance and diameter mismatch, and impedance phase angle on the wall shear rate distribution near an end-to-end artery-graft anastomosis model. The results show that radial wall motion of the elastic artery model lowers the mean wall shear rates under pulsatile flow condition by 15 to 20 % comparing to those under steady flow condition at the same mean flow rate. Impedance phase angle seems to have small effects on the mean and amplitude of the wall shear rate distribution. In order to study the effects of compliance and diameter mismatch on the wall shear rates, two models are studied-Model I has 6% and Model I has 6% and Model II has 11% smaller graft diameter. Divergent geometry caused by diameter mismatch near the distal sites reduces the mean wall shear rates significantly, and this low shear region is believed to be prone to intimal hyperplasia.

  • PDF