• Title/Summary/Keyword: Flow impedance

Search Result 234, Processing Time 0.025 seconds

Modification of the experimental method for measuring acoustic impedance of perforated elements with grazing flow (스치는 유동이 존재하는 원형 천공의 음향 임피던스 측정 방법 개선)

  • Lee Seong-Hyun;Ih Jeong-Guon;Peat Keith
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.297-300
    • /
    • 2004
  • Perforated elements are extensively used in mufflers for the intake and exhaust systems of various fluid machines. Perforated elements are usually exposed to grazing flow or cross flow. For analyzing performances of mufflers, the impedance of perforated elements with mean flow is very important. The impedance of perforates under both conditions are measured with different experimental setups. Even if there is no flow, the preceding experimental method for grazing flow shows different values with both theoretical ones and measured under cross flow setup. Using high-order analysis considering phase differences, the experimental method for grazing flow can be modified. The acoustical impedance of perforated impedance contains interaction effects between orifices. After correcting these effects, the measured impedance with grazing flow setup show similar results with both theoretical impedance and measured ones under cross flow setup.

  • PDF

Acoustic impedance model of perforated elements with both grazing and bias flow (스치는 유동과 관통 유동의 영향을 고려한 천공 요소의 음향 임피던스 모델)

  • Lee, Seong-Hyun;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1372-1375
    • /
    • 2006
  • The simplified impedance model which can consider a combined flow condition was suggested. Although the strength and position of the shear layer cannot be obtained by a linear sum of two separate contributions when both flows occur together, it was simply assumed that the impedance under the combined flow follows from summing the separate flow impedance. To validate the simplified impedance model, acoustic properties of a concentric resonator was predicted and measured. The predicted transmission loss using the simplified model shows reasonable agreements with measurements. One can find that the simplified impedance model obtained by the superposition of the separate flow impedances can be adjusted to predict the acoustic properties of a concentric resonator.

  • PDF

Void Fraction Measurements Using the Impedance Method (임피던스 방법을 이용한 기공율 측정에 대한 연구)

  • Kim, M.H.;Yang, H.C.;Song, C.H.;Jung, M.K.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.721-727
    • /
    • 2000
  • Impedance method was carried out to design the electrode that can measure the void fraction of the bubbly flow in pool reservoir. To find out the optimum electrode shape, Styrofoam-tests were performed in a specially designed acrylic reservoir. Three kinds of electrodes were designed to compare the characteristics of water-air flow. The resistance was increased as the void fraction increased and the capacitance was decreased as the void fraction increased. The resistance is a main parameter to express the nature of the water-air flow in impedance method. Almost all the values of impedance were involved in resistance. The degree of deviation from the mean-resistance values showed reasonable results. Electrode type-I expressed excellent results among the three electrode shapes. The impedance values in void fraction 0-10% were similar to those of Maxwell's equation. But the impedance values in void fraction 10-20% were not similar to those of Maxwell' equation because of the edge effect near electrode.

  • PDF

Measurement of Blood Flow Variation using Impedance Method (임피던스법을 이용한 혈류량 변화 측정)

  • Jeong Do-Un;Kang Seong-Chul;Jeon Gye-Rock
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.693-696
    • /
    • 2006
  • In this study, we made the system to measure variation of blood flow using bio-electrical impedance analysis method. The system, which could measure variation of impedance according to pressure change by artificial pressure, consists of pressure measurement and impedance measurement by 4-electrode method. Pressure measurement splits into semiconducting pressure sensor and electronic circuit for processing output signal. In addition, impedance measurement splits into constant current source circuit and lock-in amplifier for detection impedance signal. We experimented feature of impedance measurement using standard resistance to evaluate the system characteristic. As well as, we experimented to estimate variation of blood flow by measuring impedance and blood flow resistance ratio using mean arterial pressure and variation of blood flow with experimental group. As result of this study, blood flow resistance ratio and variation of blood flow were definitely in inverse proportion and were -0.96776 as correlation coefficient by correlation analysis.

  • PDF

Implementation of Impedance Method to Estimate Blood Flow Variation with Cuff Pressure Change (커프 압력 조절에 따른 혈류량 변화 평가를 위한 임피던스법의 구현)

  • Jeong, Do-Un;Bae, Jin-Woo;Shon, Jung-Man;Yae, Su-Yung;Choi, Byeong-Cheol;Nam, Ki-Gon;Kim, Cheol-Han;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.462-472
    • /
    • 2004
  • In this study, we measured the blood flow on arm by non-invasive method and implemented a system to measure variation of the blood flow by estimating bio-electrical impedance and arterial pressure according to cuff pressure. The implemented system measured impedance variation according to pressure variation applied by artificial cuff pressure on the measuring position. The system consisted of pressure measuring part and impedance measuring part using 4-electrode method. Pressure measuring part was composed of semiconductor pressure sensor and electronic circuit for signal processing of sensor output signal. In addition, impedance measuring part was composed of constant current source circuit and lock-in amplifier for detecting impedance signal. We conducted experiments of impedance measuring part using standard resistance for performance evaluation of the implemented system. In addition we experimented to estimate variation of the blood flow by measuring impedances of the experimental group. We estimated ratio of the blood flow resistance using mean arterial pressure and variation of the blood flow. As a result the ratio of the blood flow resistance and variation of blood flow were in an inverse relationship with each other and the correlation coefficient was -0.96776.

Impedance Characteristics of operate fluid about Frictional loss in seamless pipeline (SEAMLESS 관의 마찰손실에 따른 작동유체의 임피던스 특성)

  • 모양우;유영태;최병재
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.304-310
    • /
    • 2001
  • Flow pulsation often causes vibration and noise in piping systems and therefore has been a troublesome concern for fluid system engineers. According to frequency increase in this paper under the influence wave form of velocity in springly flow and viscosity are drop coefficient of viscosity become increase so that impedance and resistance. The transient variations of flow rate are measured by a modified impedance tube method which is realized by virtue of the present analytical technique. At pipe line in order to eliminate vibration, confirm happened intermittently impedance characteristics. We make a test and frequency analysis and have to minimize obstructive component at hydraulic circuit.

  • PDF

Acoustical Properties of Polyester Sound Absorbing Materials (폴리에스테르 흡음재의 음향특성)

  • 주경민;용호택;이동훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1347-1352
    • /
    • 2001
  • In this study, the acoustic properties of polyester sound absorbing materials with three different bulk densities were investigated by calculating and measuring the acoustic parameters in terms of characteristic impedance, propagation constant, and absorption coefficient. For the calculations, Delany and Bazley's empirical equation was used together with the experimentally obtained specific flow resistivities under steady flow conditions. For the experimental measurements, the well-known two-thickness method was accessed. The experimentally measured values of characteristic impedance and propagation constant were generally agreed well with the corresponding calculated values. Based on the comparisons between the calculations and measurements, it was found that the magnitude of the absorption coefficient was closely related to the characteristic impedance and the real part of the propagation constant. Especially, the maximum magnitude of the absorption coefficient was depended upon the imaginary part of the propagation constant indicating the phase change of the propagation constant.

  • PDF

Performance test of 100 W linear compressor

  • Ko, J.;Koh, D.Y.;Park, S.J.;Kim, H.B.;Hong, Y.J.;Yeom, H.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.3
    • /
    • pp.35-39
    • /
    • 2013
  • In this paper, we present test results of developed 100 W class linear compressor for Stirling-type pulse tube refrigerator. The fabricated linear compressor has dual-opposed configuration, free piston and moving magnet type linear motor. Power transfer, efficiency and required pressure waveform are predicted with designed and measured specifications. In experiments, room temperature test with flow impedance is conducted to evaluate performance of developed linear compressor. Flow impedance is loaded to compressor with metering valve for flow resistance, inertance tube for flow inertance and buffer volumes for flow compliance. Several operating parameters such as input voltage, current, piston displacement and pressure wave are measured for various operating frequency and fixed input current level. Behaviors of dynamics and performance of linear compressor as varying flow impedance are discussed with measured experimental results. The developed linear compressor shows 124 W of input power, 86 % of motor efficiency and 60 % of compressor efficiency at its resonant operating condition.

Note on the Two-Microphone Methods for the Measurement of Acoustic Impedance (음향 임피던스 측정을 위한 이중 마이크로폰 기법에 대한 고찰)

  • SEO, SEONGHYEON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.2
    • /
    • pp.163-169
    • /
    • 2018
  • The present article discusses about the measurement techniques of acoustic impedance that becomes one of the important acoustic characteristics of various boundaries found inside of propulsion systems. Acoustic characteristics including acoustic impedance and reflection coefficient can be often assessed and estimated by use of the two-microphone method. Theoretical expressions of acoustic impedance and reflection coefficient measured in an impedance tube are presented for both cases with mean flow and without flow, and the practical application of the method through calibration is also provided. The acoustic impedance and the reflection coefficient are related with axial locations of microphones, thermodynamic characteristics of gas inside, and the transfer function between the pressure wave measurements at multiple locations.

Measurement of the Void Fraction of Slug and Bubbly Flows Using Three-Ring Impedance Meters (3-ring 임피던스미터를 이용한 슬러그류 및 기포류의 기공률 측정)

  • Kim, Jong-Rok;Ahn, Yeh-Chan;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.83-88
    • /
    • 2012
  • Real slug and bubbly flows were measured using a three-ring impedance meter that can efficiently measure the void fraction of two-phase flows in a tube. First, the fitting curves between the signal from the impedance meters and the void fraction were found. The impedance meter had different fitting curves for slug and bubbly flows that had the same void fraction. An impedance meter should choose one of the two fitting curves according to the flow pattern, and the flow patterns can be recognized using the measured void fraction. The velocities and sizes of the bubbles were calculated using the void fraction curves measured by two impedance meters.