• 제목/요약/키워드: Flow front

검색결과 888건 처리시간 0.031초

일부 대학교 미생물실험실 및 화학실험실에서의 진균 분포 및 관련인자 (Levels and Related Factors of Airborne Fungi in Microbial and Chemistry Laboratories in Universities)

  • 황성호;조현우;박동욱;윤충식;류경남;하권철
    • 한국산업보건학회지
    • /
    • 제20권1호
    • /
    • pp.41-46
    • /
    • 2010
  • The purpose of this study is to assess the level of fungi concentration in the university laboratories in Seoul, Korea, and to investigate factors contributing to these concentrations. The samples were taken from three spots in each laboratory; the top of sink, the center of laboratory, and the front of ventilation system, i.e fume hood at the chemical laboratory and clean bench/biosafety cabinet at the microbial laboratory. Air samples were collected using the single-stage Anderson sampler (Quick Take 30) at a flow rate of 28.3 l/min for 5 min on nutrient media in Petri-dishes located on the impactor. Fifty-two air samples were collected from 19 different laboratories (13 microbiology laboratories, 6 chemistry laboratories) in the university, and concentrations of airborne fungi showed no significant difference (p>0.05) between microbiology and chemistry laboratory, and also no significant difference at three locations (sink, center, front of ventilation system) in microbiology and chemistry laboratories. Average concentrations of fungi in 19 laboratories ranged from 7 to 459 cfu/$m^3$, with an overall Geometric Mean of 52 cfu/$m^3$. Airborne fungi concentrations of 6 samples (12 %) exceeded 150 cfu/$m^3$, the guideline of WHO. The ratios of Indoor/Outdoor for airborne fungi ranged from 0.2 to 4.8 (mean = 1.6). Related factors were measured such as relative humidity, temperature, and laboratory area. Temperature and laboratory area showed no significant relations to concentrations of airborne fungi except for relative humidity in the laboratory Concentrations of fungi were significant different (p<0.01) between rainy or cloudy and sunny. However, there was no significant difference between general ventilation and nongeneral ventilation.

점 오염원 조사를 통한 목포 내항의 수질관리 (Management of Water Quality by the Point Source in Mokpo Inner Bay)

  • 김도희
    • 해양환경안전학회지
    • /
    • 제12권4호
    • /
    • pp.273-283
    • /
    • 2006
  • 2004년 강수량이 많았던 8월 목포 주변해역의 8개 지점에서 COD를 조사한 결과, 북항 앞바다에서 6.80 ppm, 영산강 하구둑 부근 해역에서 4.42 ppm, 신안비치 호텔 앞 해역에서 4.60 ppm으로 나타나 해양환경 기준치의 3등급을 초과하고 있었고 나머지 지점에서는 2-3등급 수준을 보였다. 총질소 농도는 1.23-3.56 ppm으로 전 지점에서 3등급 이상이었고, 총인의 농도는 0.07-0.12 ppm으로 2-3등급의 수질을 보였다. 이와 같은 수질은 수산생물의 서식, 양식 및 해수욕 등의 해양레저 활동을 하기에 부적합하며 공업용수와 선박의 정박 등에 이용 할 수 있는 수질 상태를 보였다. 육상으로부터의 목포 내항으로 유입되는 12개 지점의 점원 유입 부하량과 그 기여율을 조사한 결과, 전체 유입양 중 영산강으로부터 유입되는 총질소의 양이 70-93 %, 총인의 유입량도 31-91%를 차지하고 있어 목포 내항의 수질개선을 위해서는 영산강의 수질개선이 급선무이며, 다음으로 북항 하수처리장, 임암천, 남해 하수처리장 순으로 방류수 중의 질소와 인을 우선적으로 제어해야 될 것으로 판단되었다.

  • PDF

발전소 터빈건물의 창문 위치에 따른 온도저감 (Temperature Reduction with the Location of Window in a Turbine Building of Power Plant)

  • 하지수;김태권;정경호
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.207-213
    • /
    • 2016
  • 본 연구에서는 화력발전소 터빈 건물의 온도저감 방안을 도출하기 위해 전산유체역학 상용코드인 ANSYS-FLUENT를 이용하여 열유동 해석을 수행하였다. 터빈 건물의 운전층(operating floor)과 탈기기층(deaerator floor)을 검사체적으로 선정하여 모델링을 하였으며 탈기기층에 설치된 기존의 채광창을 활용하여 환기창으로 대체하는 경우에 대해 해석을 수행하였다. 본 연구를 통하여 첫째, 운전층의 온도를 저감하기 위한 방안은 탈기기층의 모든 창문을 열지 않아야 됨을 알았다. 둘째, 탈기기층의 온도를 저감하기 위한 방안으로 탈기기층의 전면부의 창문을 개방하면 탈기기 영역과 크레인 영역은 각각 $1.5^{\circ}C$$1.6^{\circ}C$를 저감할 수 있었고, 탈기기 후면부의 창문을 개방하면 탈기기 영역은 $1.4^{\circ}C$, 크레인 영역은 $0.5^{\circ}C$의 온도를 저감할 수 있었다. 따라서 고온의 탈기기층 전체 영역의 온도를 저감하기 위해서는 탈기기층 전면부의 창문을 개방하는 것이 유리할 것으로 판단된다.

통일신라시대(統一新羅時代) 불교건축(佛敎建築)의 변화(變化) (The Change in the Buddhist Architecture of the Unified Silla Period (668-935))

  • 김성우
    • 건축역사연구
    • /
    • 제1권2호
    • /
    • pp.68-84
    • /
    • 1992
  • The development of Buddhist architectures of the Unified Silla period have been generally understood to have paired pagoda instead of one which had been popular until before the unification. Besides the stylistic categorization of paired pagoda system, there had been no further investigation reported concerning whether there was any detailed process of change within the development of paired pagoda style. This paper aims to identify such change inside the development of paired pagoda style, which, externally, seems to be the same pattern of site design maintained throughout the period of Unified Silla that lasted for about three centuries. Since the temple sites of study are in the same pattern of layout, the method of investigation has to be such that can identify the subtle changes that, in external appearance, are not easily discernible. Hence, this research compared the dimensions of important measurement of five temple sites to be able to clarify the process of minor changes. Among many sites of Silla temples, only five were suitable for the research since detailed measurement were possible through field research or the report of excavation. They are the sites of Sachonwang-sa, Mangduk-sa, site of Kunsuri, and Bulguk-sa. Although the five sites have the same style of paired pagoda, it is clear that there were consistant flow of change. Even though the motivation of such change were not strong enough to change the site pattern itself, it resulted continuous minor changes such as the size and location of architectures. The size of image hall, for example, was growing larger and larger as time goes on, while, the size of Pagoda was getting smaller. In the same way, the size of middle gate became smaller while the size of lecture hall became larger, although the rate of change in these cases were not as severe as that of image hall and pagoda. At the same time, pagoda was coming closer to the middle gate leaving larger space in front of the image hall. Such aspect is even more meaningful considering the fact that the pagoda, from the 8th century in Japan and China, moved outside of the major precinct. The image hall, too, moved toward the middle gate slightly so that the space in front of the lecture hall became more spacious. Such changes, of course, were not accidental but they are the same continuous motivation of change that caused the changes before the period of unification. Enlargement of image hall and reduction of pagoda, for example, represent the changing relative importance of religious meaning. Hence, it is evident that one can not easily imterprete the development of one style only by categorizing it to be one same style. In the veiwpoint of the underlying motivation of change, the fact that one style persisted for a certain period of time, does not mean there had been no change, but means that it was the time of motivational accumulation, causing minor changes within the same style, to be able to create major change coming after.

  • PDF

충돌공기(衝突空氣) 분류계(噴流系)에서의 전열촉진기술(傳熱促進技術)에 관(關)한 연구(硏究) (Technique of Heat Transfer Augmentation in Impinging Air Jet System)

  • 최두섭;금성민;이용화;서정윤
    • 태양에너지
    • /
    • 제13권1호
    • /
    • pp.11-21
    • /
    • 1993
  • 이차원(二次元) 충돌공기분류계(衝突空氣噴流系)에서 흐름방향과 수직(垂直)이 되게 설치한 평판전열면(平板傳熱面) 전방(前方)에 난류촉진체(亂流促進體)인 정4각(正4角) 로드군(群)(로드폭=4mm, 로드피치=50mm)을 설치하고 로드와 전열면(傳熱面)사이의 간극(間隙)(C=1, 2, 4, 6mm), 노즐출구와 전열면간(傳熱面間) 거리(H/B=2, 6, 10, 14) 및 Re수($Re=6.410{\times}10^3{\sim}5.769{\times}10^4$)를 변화시켜 실험한 결과, 평판(平板)에서 열전달계수(熱傳達系數)의 감소율이 큰 영역에서도 로드를 설치하므로써 높은 열전달계수(熱傳達係數)를 얻을 수 있었으며, 실험범위내의 Re수와 H/B에 대하여 열전달계수(熱傳達係數)가 최대(最大)가 되는 최적간극(最適間隙)은 C=1mm이고, 최대(最大) 열전달증진율은 H/B=2, C=1mm에서 로드를 설치하지 않은 평판(平板)보다 약 43% 증진한다.

  • PDF

LES와 One Equation Dynamic Smagorinsky 난류모형을 이용한 Beach Cusps 쇄파역에서의 경계층 Streaming 수치해석 (Numerical Analysis of the Hydraulic Characteristics of a Boundary Layer Streaming over Beach Cusps Surf-Zone Using LES and One Equation Dynamic Smagorinsky Turbulence Model)

  • 조용준
    • 한국해안·해양공학회논문집
    • /
    • 제32권1호
    • /
    • pp.55-68
    • /
    • 2020
  • 너울이 우세한 온화한 해양환경에서 출현하는 beach cusp에서의 경계층 streaming 수리특성을 살펴보기 위해 edge waves의 천수 과정을 수치 모의하였다. Beach cusp을 유지하는 것으로 알려진 synchronous edge waves는 같은 주기와 파고를 지니는 두 개의 Cnoidal wave가 전면해역에서 비스듬히 조우 되도록 조파하여 재현하였다. Beach cusp의 진폭 AB과 파장 LB은 맹방 해변에서 수행된 관측결과를 토대로 각각 1.25 m, 18 m로 선정하였다. 모의결과 천수 각 단계에서 예외 없이 경계층 streaming을 관측할 수 있었으며 최대 경계층 streaming은 사주 정점에서 발생하였다. 주기가 가장 짧은 RUN 1의 경우 그 세기는 약 0.32 m/s 내외에 분포하며 이러한 수치는 free stream 유속 u 진폭의 두 배에 달하는 것으로 wave Reynolds 응력에 기반한 Longuet-Higgins(1957)의 해석 해와는 상당한 차이를 보였다. 수치 모의과정에서 온화한 해양환경에서 해빈이 복원되는 과정을 특정할 수 있었으며 이 과정을 정리하면 다음과 같다: 너울로 구성된 파랑 무리에서 성분 파랑 간의 공진성 상호작용으로 생성된 외 중력파가 쇄파선 인근에 도달하는 경우 중력으로 인한 가속이 더해진 Phase II 파랑 궤도 운동으로 수면 가까이 상승한 많은 모래가 쇄파 시 발생하는 파 마루로부터 시작된 up-rush에 의해 전 빈 정점 가까이 이동하며 이 과정에서 발생하는 침투로 인해 퇴적되는 것으로 모의 되었다.

독성 가스 누출 시 건물 방향이 대피 기준에 미치는 영향에 관한 수치 해석 연구 (A Numerical Study of Building Orientation Effects on Evacuation Standard in Case of Toxic Gas Leakage)

  • 조승범
    • 한국가스학회지
    • /
    • 제27권4호
    • /
    • pp.12-18
    • /
    • 2023
  • 독성 가스 누출 사고 발생 시 인명 피해를 최소화하기 위해서는 사고 시나리오에 따른 적절한 대피 방법이 사전에 수립되어야 한다. 본 연구에서는 동일 누출 조건에서 건축물의 방향과 산업단지 위치가 실내 농도 증가와 실외 확산에 미치는 영향을 살펴보고 효과적인 대피 기준을 마련하였다. 또한 이러한 기준을 바탕으로 화학사고 인명 피해 최소화라는 관점에서 건물을 건설할 때 건물 방향에 대한 기준도 마련하였다. 건물의 방향이 누출 방향에 대해 정면, 측면, 후면인 경우에 대해 전산 수치 해석을 수행하였으며, 그 결과 건물 창문이 누출되어 오는 방향과 마주보고 있을 때의 실내 오염농도가 반대편에 창문이 있을 때의 실내 오염농도와 비교하여 120배 정도 높게 나왔다. 또한, 급격한 실내 농도 증가율로 동일 시간에 실내 공간이 2배 이상 독성 가스 물질로 가득하게 되었다. 이러한 현상은 건물 창문이 정면에 위치한 경우 창문 주위의 압력 차와 속도 저하로 건물 주위에 독성 가스가 정체하게 되는 것으로 나타났다. 본 연구 결과를 바탕으로 최적 대피를 위한 건축물 방향 기준을 설정한다면 화학사고 발생 시 주민들의 피해를 최소화하는 데 도움이 될 것으로 판단된다.

포화 사질토에서 전방 차수층이 쉴드터널 초과 이수압에 미치는영향 (Effect of a frontal impermeable layer on the excess slurry pressure during the shield tunnelling in the saturated sand)

  • 이용준;이상덕
    • 한국터널지하공간학회 논문집
    • /
    • 제13권4호
    • /
    • pp.347-370
    • /
    • 2011
  • 이수가압식 쉴드공법은 이수압을 적정 수준으로 관리하면 특히 사질토에서 적용성이 우수하지만, 이수압이 낮으면 이수 유출 및 지반변형이 발생하기도 한다. 따라서 이수가압식 쉴드공법에서는 초기 막장압보다 큰 초과 이수압을 가하여 막장의 안정을 유지한다. 그러나 이수압이 너무 높으면 전방 지반의 수동 파괴를 유발하므로 전방 지반의 수동 파괴 위험성을 배제하고 이수압을 증가시키는 방법으로 막장 전방에 수평 차수층을 설치하는 방안이 있으나 그 위치와 규모 및 효과가 잘 알려져 있지 않다. 따라서 본 연구에서는 포화된 사질토에서 막장 전방에 차수 그라우팅을 적용할 경우에 발생하는 효과를 규명하기 위하여 모형실험을 수행하였다. 실험에서는 차수층의 위치와 길이를 변화시거면서 이수의 유출이나 지반 파괴 이전까지 이수압을 가하여 최대 이수압과 지반 변위 및 이수의 유출로 인한 파괴 형상을 측정하여 분석하였다. 실험 결과, 전방 차수층이 없는 경우에 최대 이수압과 초과 이수압은 토피고에 선형비례 하였으며, 차수층이 존재하는 경우에는 차수층이 없는 경우보다 이수압을 크게 가할 수 있어서 전방 차수층이 막장 안정성을 증대시킬 수 있다는 것을 확인할 수 있었다. 막장 안정성 증대에 가장 큰 영향을 주는 적정 차수층의 규격은 길이 1.0 ~ 1.5D, 설치높이 1.0D로 나타났다. 초기 막장압 대비 최대 이수압의 비로 막장의 자립 안전율(F)을 제안할 수 있으며, 전방 차수층을 적정 위치에 설치할 경우 초기 막장압보다 3.5~4.0배 크게 이수압을 가할 수 있는 것으로 나타났다.

SOOT YIELD OF TURBULENT PREMIXED PROPANE-OXYGEN-INERT GAS FLAMES IN A CONSTANT-VOLUME COMBUSTOR AT HIGH PRESSURES

  • Bae, M.W.;Bae, C.W.;Lee, S.K.;Ahn, S.W.
    • International Journal of Automotive Technology
    • /
    • 제7권4호
    • /
    • pp.391-397
    • /
    • 2006
  • The soot yield has been studied by a premixed propane-oxygen-inert gas combustion in a specially designed disk-type constant-volume combustion chamber to investigate the effect of pressure, temperature and turbulence on soot formation. Premixtures are simultaneously ignited by eight spark plugs located on the circumference of chamber at 45 degrees intervals in order to observe the soot formation under high temperature and high pressure. The eight converged flames compress the end gases to a high pressure. The laser schlieren and direct flame photographs with observation area of 10 mm in diameter are taken to examine the behaviors of flame front and gas flow in laminar and turbulent combustion. The soot volume fraction in the chamber center during the final stage of combustion at the highest pressure is measured by the in-situ laser extinction technique and simultaneously the corresponding burnt gas temperature by the two-color pyrometry method. The changes of pressure and temperature during soot formation are controlled by varying the initial charging pressure and the volume fraction of inert gas compositions, respectively. It is found that the soot yield increases with dropping the temperature and raising the pressure at a constant equivalence ratio, and the soot yield in turbulent combustion decreases as compared with that in laminar combustion because the burnt gas temperature increases with the drop of heat loss for laminar combustion.

PSP를 이용 다양한 공동 후류의 전역적 압력분포 측정 (The Whole Region Pressure Measurement of Cavity Downstream using PSP Technique)

  • 서형석;오주영;전영진;이재우;변영환
    • 한국추진공학회지
    • /
    • 제11권6호
    • /
    • pp.50-57
    • /
    • 2007
  • Pressure Sensitive Paint(PSP)는 압력에 반응하는 도료를 뜻한다. PSP는 압력에 반응하는 대기 중의 산소량을 측정하여 전역적인 압력정보를 광학적으로 측정 할 수 있다. 본 연구에서는 PSP를 사용하여 제트 분사 후류의 표면압력 분포를 알아보았다. 또한 제트 분사구 5mm앞에 종횡비 1에서 4까지의 사각형 공동을 위치시켜 후류에 미치는 영향을 알아보았다. 제트 분사 후류의 압력 분포는 공동의 전단층의 영향으로 공동이 없을 때와 비교해서 옆으로 넓게 퍼지면서 강도는 약해지는 모습을 보였다. 또한 공동의 종횡비가 커짐에 따라서 전단층의 크기가 커지고 그 영향이 커졌다. 현재까지의 계산 결과는 압력공과 같은 불연속점에서의 압력측정 결과와 비교하였다. 본 연구에서는 전영역에서의 압력을 측정하여 전산해석 결과와 근접함을 증명함으로써 공동 후류에서의 유동현상을 보다 명확히 파악하였다.