• Title/Summary/Keyword: Flow failure

Search Result 882, Processing Time 0.028 seconds

Piping Analysis for Excavation in a Embankment (굴착에 따른 인접 제방의 파이핑 해석)

  • Lee, Song;Kook, Joong-Jin;Jung, Min-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.1 s.53
    • /
    • pp.59-68
    • /
    • 2009
  • One of the cause of embankment failure for piping is a routine design for piping consideration without exact understanding of that. Therefore, in this study, comparison and analysis of existing piping consideration methods had been conducted through embankment sections when sheet piles constructed on sandy ground. For the Terzaghi method and the critical hydraulic method, safety factors were changed up to double depending on the method. And for the critical velocity method, it was dramatically changed due to design parameters. Consequently, existing piping consideration method currently used is recommended not to be applied to all ground conditions uniformly but to applied with exact understanding of each consideration method characteristics depending on ground conditions.

Bronchial Responsiveness in Patients with Mitral Valvular Heart Disease (승모판 심장질환 환자에서 기관지 반응성에 대한 연구)

  • Kim, Ho-Cheol;Kim, Min-Gu;Hwang, Young-Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.752-759
    • /
    • 1995
  • Background: Bronchial asthma is characterized by noctunal dyspnea, cough and wheezing because of airway hyperresponsiveness to nonspecific stimuli. These symptoms and signs are also observed in patients with congestive heart failure. Therefore, this is so called "cardiac asthma". There are lots of experimental and clinical datas to suggest that airway dysfunctions occur in acute and chronic congestive heart failure. However, it is still controversial whether bronchial hyperresponsiveness is present in patients with congestive heart failure. To assess whether bronchial hyperresponsiveness is present in patients with congestive heart failure and to demonstrate the relationship between bronchial responsiveness and vascular pressure, we performed methacholine provocation test in 11 patients with mitral valvular heart disease. Methods: All patients were in the New York Heart Association functional class II and treated continuously with digoxin and/or dichlozid and/or angiotensin converting enzyme inhibitor except one patient. All patients were undergone right and left side heart catheterization for hemodynamic measurements. A 20 percent fall of peak expiratory flow rate were considered as positive response to methacholine provocation test. Results: 1) Only one patient who has normal pulmonary artery pressure, pulmonary capillary wedge pressure, cardiac index was positive in methacholine provocation test. 2) Their mean pulmonary artery pressure, pulmonary capillary wedge pressure were $21.72{\pm}9.70mmHg$, $15.45{\pm}8.69mmHg$ respectively which were significantly higher. Conclusion: It is speculated that in stable congestive heart failure patients, bronchial responsiveness as assessed by methacholine provocation test may not be increased.

  • PDF

Proposition of a Practical Hybrid Model for the Valuation of Technology (기술가치평가를 위한 실용적 하이브리드 모델의 제안)

  • Park, Hyun-Woo;Nah, Do-Baek;Park, Jong-Kyu
    • Management & Information Systems Review
    • /
    • v.28 no.4
    • /
    • pp.27-44
    • /
    • 2009
  • Economic value of a certain technology is of great interest and importance in a wide variety of investment circumstances. These vary from companies considering investing in R&D projects, to venture capitalists funding start-up companies. However, such valuation is extremely difficult in any case, and the cost of failure can be very high. Many techniques have been proposed to assist managers facing this issue, from traditional discounted cash flow analysis to more recent methods based on real options. In the meantime, the discounted cash flow method has limitations in applying the valuation of technology. At the same time, there have been various solutions to overcome theoretical problems of the method. Real options have been thought as a solution. However, there are another problems in using them in real world. This paper reviews the previous studies on the valuation of technology in several aspects, discusses the practicability of the various methods available, and explore the application of a hybrid model, which aims to make these rather aore the ideas more accessible to practicing managers.

  • PDF

Safety of Aprotinin Under Hypothermic Circulatory Arrest (초저체온 및 순환정지하에서 Aprotinin의 안전성)

  • 장병철;김정택
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.501-505
    • /
    • 1997
  • It was reported that use of aprotinin in elderly patients undergoing hypothermic circulatory arrest was associated with an increased risk of renal dysfunction, and myocardial infarction as a result of intravascular coagulation. We reviewed 20 patients who received high-dose aprotinin under deep hypothermic circulatory arrest with(NP group, n= 11) or without selective cerebral perfusion(SP group, n=9). The activated clotting time was exceeded 750 seconds in all but 1 patient. After opening aortic arch, retrograde low flow perfusion was maintained through femoral artery to prevent air embolization to the visceral arteries. Four patients among 20 died during hospitalization'due to bleeding, coronary artery dissection pulmonary hemorrhage and multiple cerebral infarction. Postoperatively, cerebrovascular accidents occurred in two patients; one with preoperative carotid artery dissection and the other with unknown multiple cerebral infarction. In conclusion, use of aprotinin in young patients undergoing hypothermic circulatory arrest did not increase the risk of renal dysfunction or intravascular coagulation if ACT during circulatory arrest is maintained to exceed 750 seconds with low-flow perfusion.

  • PDF

Pressure Regulation System for Optimal Operation of the Pneumatic VAD with Bellows-Type Closed Pneumatic Circuit (벨로우즈 방식의 폐회로를 가진 공압식 심실 보조장치의 최적 작동을 위한 압력 조절 시스템)

  • Kim, Bum-Soo;Lee, Jung-Joo;Nam, Kyung-Won;Jeong, Gi-Seok;Ahn, Chi-Bum;Sun, Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.569-576
    • /
    • 2007
  • Ventricular Assist Device(VAD) has switched its goal from a short-tenn use for bridge-to-transplantation to a long-tenn use for destination therapy, With this goal, the importance of long-tenn reliability gets more interests and importances, H-VAD is an portable extracorporeal biventricular assist device, and adopts an electro-pneumatic driving mechanism. The pneumatic pressure to pump out blood is generated with compression of bellows, and is transmitted in a closed pneumatic circuit through a pneumatic line. The existing pneumatic VAD adopts a air compressor which can generate stable pressures but has defects such as a noise and a size problem. Thus, it is not suitable for being used as a portable device, These problems are covered with adopting a closed pneumatic circuit mechanism with a bellows which has a small size and small noise generation, but it has defects that improper pneumatic setting causes a failure of adequate flow generation. In this study, the pneumatic pressure regulation system is developed to cover these defects of a bellows-type pneumatic VAD. The optimal pneumatic pressure conditions according to various afterload conditions for an optimal flow rate were investigated and the afterload estimation algorithm was developed, The final pneumatic regulation system estimates a current afterload and regulate the pneumatic pressure to the optimal point at a given afterload condition. The afterload estimation algorithm showed a sufficient performance that the standard deviation of error is 8.8 mmHg, The pneumatic pressure regulation system showed a sufficient performance that the flow rate was stably governed to various afterload conditions. In a further study, if a additional sensor such as ultrasonic sensor is developed to monitor the direct movement of diaphragm in a blood pump part, the reliability would be greatly increased. Moreover, if the afterload estimation algorithm gets more accuracy, it would be also helpful to monitor the hemodynamic condition of patients.

Study on Behaviour of Flood Wave-front Varied with Levee Breach Speed in Flat Inundation Area (평탄지형 제내지에서의 제방붕괴속도에 따른 범람홍수파 선단 거동에 관한 연구)

  • Yoon, Kwang Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.537-544
    • /
    • 2017
  • An experimental study was carried out to investigate the characteristics of the propagation distance of a flood wave considering the levee failure speed in a flat inundation area. The Ritter solution for one dimensional flow was considered to formulate the experimental results and a representative form with coefficients of k and m, which consider the three dimensional flow characteristics, was applied. The experiments showed that the propagation velocity of the wave front in the inundation area was influenced by the levee breach speed as well as the initial water level, which is a significant variable representing the flood wave behavior. In addition, coefficients k and m are not constants, but variables that vary with levee breach speed. An empirical formula was also suggested using the experimental results in the form of the relationships between k and m. In this study, a large-scale experiment for flood inundation was carried out to examine the behavior of flooding in the inundated area and the relationships between the levee breach speed and wave-front propagation velocity were suggested based on the experimental results. These research results are expected to be used as the baseline data to draw a flow inundation map, establish an emergency action plan, and verify the two-dimensional numerical model.

A PRELIMINARY EVALUATION OF UNPROTECTED LOSS-OF-FLOW ACCIDENT FOR A PROTOTYPE FAST-BREEDER REACTOR

  • SUZUKI, TOHRU;TOBITA, YOSHIHARU;KAWADA, KENICHI;TAGAMI, HIROTAKA;SOGABE, JOJI;MATSUBA, KENICHI;ITO, KEI;OHSHIMA, HIROYUKI
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.240-252
    • /
    • 2015
  • In the original licensing application for the prototype fast-breeder reactor, MONJU, the event progression during an unprotected loss of flow (ULOF), which is one of the technically inconceivable events postulated beyond design basis, was evaluated. Through this evaluation, it was confirmed that radiological consequences could be suitably limited even if mechanical energy was released. Following the Fukushima-Daiichi accident, a new nuclear safety regulation has become effective in Japan. The conformity of MONJU to this new regulation should hence be investigated. The objectives of the present study are to conduct a preliminary evaluation of ULOF for MONJU, reflecting the knowledge obtained after the original licensing application through CABRI experiments and EAGLE projects, and to gain the prospect of in-vessel retention for the conformity of MONJU to the new regulation. The preliminary evaluation in the present study showed that no significant mechanical energy release would take place, and that thermal failure of the reactor vessel could be avoided by the stable cooling of disrupted-core materials. This result suggests that the prospect of in-vessel retention against ULOF, which lies within the bounds of the original licensing evaluation and conforms to the new nuclear safety regulation, will be gained.

Numerical modelling of Fault Reactivation Experiment at Mont Terri Underground Research Laboratory in Switzerland: DECOVALEX-2019 TASK B (Step 2) (스위스 Mont Terri 지하연구시설 단층 내 유체 주입시험 모델링: 국제공동연구 DECOVALEX-2019 Task B(Step 2))

  • Park, Jung-Wook;Guglielmi, Yves;Graupner, Bastian;Rutqvist, Jonny;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.29 no.3
    • /
    • pp.197-213
    • /
    • 2019
  • We simulated the fault reactivation experiment conducted at 'Main Fault' intersecting the low permeability clay formations of Mont Terri Underground Research Laboratory in Switzerland using TOUGH-FLAC simulator. The fluid flow along a fault was modelled with solid elements and governed by Darcy's law with the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by creating interface elements between two separating rock blocks in FLAC3D. We formulate the hydro-mechanical coupling relation of hydraulic aperture to consider the elastic fracture opening and failure-induced dilation for reproducing the abrupt changes in injection flow rate and monitoring pressure at fracture opening pressure. A parametric study was conducted to examine the effects of in-situ stress condition and fault deformation and strength parameters and to find the optimal parameter set to reproduce the field observations. In the best matching simulation, the fracture opening pressure and variations of injection flow rate and monitoring pressure showed good agreement with field experiment results, which suggests the capability of the numerical model to reasonably capture the fracture opening and propagation process. The model overestimated the fault displacement in shear direction and the range of reactivated zone, which was attributed to the progressive shear failures along the fault at high injection pressure. In the field experiment results, however, fracture tensile opening seems the dominant mechanism affecting the hydraulic aperture increase.

Difference in Patient's Work of Breathing Between Pressure-Controlled Ventilation with Decelerating Flow and Volume-Controlled Ventilation with Constant Flow during Assisted Ventilation (보조환기양식으로서 감속형유량의 압력-조절환기와 일정형유량의 용적-조절환기에서 환자의 호흡일의 차이)

  • Kim, Ho-Cheol;Park, Sang-Jun;Park, Jung-Woong;Suh, Gee-Young;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.803-810
    • /
    • 1999
  • Background : The patient's work of breathing(WOBp) during assisted ventilation may vary according to many factors including ventilatory demand of the patients and applied ventilatory setting by the physician. Pressure-controlled ventilation(PCV) which delivers gas with decelerating flow may better meet patients' demand to improve patient-ventilator synchrony compared with volume-controlled ventilation(VCV) with constant flow. This study was conducted to compare the difference in WOBp in two assisted modes of ventilation, PCV and VCV with constant flow. Methods : Ten patients with respiratory failure were included in this study. Initially, the patients were placed on VCV with constant flow at low tidal volume($V_{T,\;LOW}$)(6-8 ml/kg) or high tidal volume($V_{T,\;HIGH}$)(10-12 ml/kg). After a 15 minute stabilization period, VCV with constant flow was switched to PCV and pressure was adjusted to maintain the same tidal volume($V_T$) received on VCV. Other ventilator settings were kept constant. Before changing the ventilatory mode, WOBp, $V_T$, minute ventilation($V_E$), respiratory rate(RR), peak airway pressure (Ppeak), peak inspiratory flow rate(PIFR) and pressure-time product(PTP) were measured. Results : The mean $V_E$ and RR were not different between PCV and VCV during the study period. The Ppeak was significantly lower in PCV than in VCV during $V_{T,\;HIGH}$. HIGH ventilation(p<0.05). PIFR was significantly higher in PCV than in VCV at both $V_T$ (p<0.05). During $V_{T,\;LOW}$ ventilation, WOBp and PTP in PCV($0.80{\pm}0.37\;J/min$, $164.5{\pm}74.4\;cmH_2O.S$) were significantly lower than in VCV($1.06{\pm}0.39J/mm$, $256.4{\pm}107.5\;cmH_2O.S$)(p<0.05). During $V_{T,\;HIGH}$ ventilation, WOBp and PTP in PCV($0.33{\pm}0.14\;J/min$, $65.7{\pm}26.3\;cmH_2O.S$) were also significantly lower than in VCV($0.40{\pm}0.14\;J/min$, $83.4{\pm}35.1\;cmH_2O.S$)(p<0.05). Conclusion : During assisted ventilation, PCV with decelerating flow was more effective in reducing WOBp than VCV with constant flow. But since individual variability was shown, further studies are needed to confirm these results.

  • PDF

FE analysis of RC structures using DSC model with yield surfaces for tension and compression

  • Akhaveissy, A.H.;Desai, C.S.;Mostofinejad, D.;Vafai, A.
    • Computers and Concrete
    • /
    • v.11 no.2
    • /
    • pp.123-148
    • /
    • 2013
  • The nonlinear finite element method with eight noded isoparametric quadrilateral element for concrete and two noded element for reinforcement is used for the prediction of the behavior of reinforcement concrete structures. The disturbed state concept (DSC) including the hierarchical single surface (HISS) plasticity model with associated flow rule with modifications is used to characterize the constitutive behavior of concrete both in compression and in tension which is named DSC/HISS-CT. The HISS model is applied to shows the plastic behavior of concrete, and DSC for microcracking, fracture and softening simulations of concrete. It should be noted that the DSC expresses the behavior of a material element as a mixture of two interacting components and can include both softening and stiffening, while the classical damage approach assumes that cracks (damage) induced in a material treated acts as a void, with no strength. The DSC/HISS-CT is a unified model with different mechanism, which expresses the observed behavior in terms of interacting behavior of components; thus the mechanism in the DSC is much different than that of the damage model, which is based on physical cracks which has no strength and interaction with the undamaged part. This is the first time the DSC/HISS-CT model, with the capacity to account for both compression and tension yields, is applied for concrete materials. The DSC model allows also for the characterization of non-associative behavior through the use of disturbance. Elastic perfectly plastic behavior is assumed for modeling of steel reinforcement. The DSC model is validated at two levels: (1) specimen and (2) practical boundary value problem. For the specimen level, the predictions are obtained by the integration of the incremental constitutive relations. The FE procedure with DSC/HISS-CT model is used to obtain predictions for practical boundary value problems. Based on the comparisons between DSC/HISS-CT predictions, test data and ANSYS software predictions, it is found that the model provides highly satisfactory predictions. The model allows computation of microcracking during deformation leading to the fracture and failure; in the model, the critical disturbance, Dc, identifies fracture and failure.