• Title/Summary/Keyword: Flow data acquisition

Search Result 183, Processing Time 0.023 seconds

A Study on the Estimation of Regional Myocardial Blood Flow in Experimental Canine Model with Coronary Thrombosis using Rb-82 Dynamic Myocardial Positron Emission Tomography (실험 개에서 Rb-82 심근 Dynamic PET 영상을 이용한 국소 심근 혈류 예측의 기본 모델 연구)

  • Kwark, Cheol-Eun;Lee, Dong-Soo;Kang, Keon-Wook;Hwang, Eun-Kyung;Jeong, Jae-Min;Chang, Kee-Hyun;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.48-53
    • /
    • 1995
  • This study investigates a simple mathematical model for the quantitative estimation of regional myocardial blood flow in experimental canine coronary artery thrombosis using Rb-82 dynamic myocardial positron emission tomography. The coronary thrombosis was induced using the new catheter technique by narrowing the lumen of coronary vessel gradually, which finally led to partial obstruction of coronary artery. Ten Rb-82 dynamic myocardial PET scans were performed sequentially for each experiment using our 5, 10 and 20 second acquisition protocol, respectively, and three regions of interest were drawn on the transaxial slices, one on left ventricular chamber for input function and the other two on normal and decreased perfusion segments for the flow estimation in those regions. Single compartment model has been applied to the measured sets of regional PET data, and the rate constants of influx to myocardial tissue were calculated for regional myocardial flow estimates with the three parameter fits of raw data by the Levenberg-Marquardt method. The results showed that, (1) single compartment model suggested by Kety-Schmidt could be used for the simple estimation of regional myocardial blood flow, (2) the calculated regional myocardial blood flow estimates were dependent on the selection of input function, which reflected partial volume effect and left ventricular wall motion, and (3) mathematically fitted input and tissue time activity curves were more suitable than the direct application of the measured data in terms of convergence.

  • PDF

Extraction of the hydrologic terrain factor in n watershed using GRID analysis technology of GSIS (GSIS의 그리드 분석 기법에 의한 수문 지형인자 추출)

  • 양인태;최영재
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.17 no.4
    • /
    • pp.349-357
    • /
    • 1999
  • Hydrologic parameters vary spatially and require interpretation of maps which often vary in scale and accuracy. Data requirements can be extensive, and acquisition and manipulation of the data are time-consuming. The purpose of this study is to develop Hydrologic Terrain Factor Extract System (HTFES) using Geo-Spatial Information System(GSIS). The HTFES is a package of spatial data and menu-driven programs that allows user-interactive determination of hydrologic parameters. The program employs Arc/Info, a commercial Geo-Spatial Information System. Spatial analysis techniques were employed to define watershed outlets and to determine important hydrologic parameters. The system delineates drainage boundaries, flow paths, average watershed slope and etc. using relevant digital elevation data.

  • PDF

The Construction and Performance Test of Complex Networks based on Ubiquitous (유비쿼터스 기반의 복합통신망 구축 및 성능시험)

  • Hong, Sung-Taek;Shin, Gang-Wook
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.23-29
    • /
    • 2011
  • We try to build the base for implementation of smart water treatment plant through identifying status by data acquisition such as temperature, humidity, flow, level, pump status and CCTV by using USN terminal such as Zigbee, Wi-Fi, UHF at the center of the flowmeter calibration center in K-water institute. The data obtained from various sensors is transmitted to data processing device through different types of USN network, the processed data is implemented to monitor by smart phone and we try to perform low cost and high efficient USN-based pilot project by implementing remote monitoring system using network performance analysis and mobile devices.

Leakage Rates Measurement System Development of NPP Primary Containment using Wireless Data Communication Method (원전 격납건물 누설시험용 무선데이터전송을 적용한 시험장치 개발)

  • Ryu, Jae-Kyu;Sohn, Chang-Ho;Hwang, Hee-Jung;Kim, Gun-Soo;Choi, Kyong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.916-919
    • /
    • 2003
  • In this paper, we deal with a development of measurement system to apply the leakage rates test of primary containment in nuclear power plant. The measurement test about leakage rates in primary containment is one sort of test to prove safety of nuclear power plant. The parameters which are measured to calculate leakage rates are drybulb temperature, dew point temperature(or relative humidity), absolute pressure and flow. Overall, the measurement system consists of sensor module for data acquisition of the parameters, transfer module for wireless data communication and control module to control system and to calculate leakage rates. Because existing measurement systems are difficult to set in field, we pursued convenience of use, we applied wireless data communication and individual form module using battery. We also changed for the better in confidence. Recently, we are developing a drybulb temperature and a dew point temperature sensor module. We describe about function of developed measurement system, its standard and an plan for verification of measurement system.

  • PDF

Designing an Context Awareness System for Effectively Managing City Facilities (도시 시설물의 효과적인 관리를 위한 상황인지 시스템 설계)

  • Jang, Seok-Woo;Cho, Sung-Youn;Hong, Sang-Ki
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.3
    • /
    • pp.65-74
    • /
    • 2011
  • With the rapid development of cites, urban facilities have rapidly been increasing, and the task of managing them have also become complicated more and more. In this paper, we propose and design an intelligent context awareness system that effectively operates underground facilities in u-City. The suggested system consists of three major steps. The information acquisition step receives alarm information of sensors from the integrated platform. The analysis and inference step analyzes the alarm data and related information and infers the reason why the alarm happens. The information transmission step sends the final results of context awareness to the platform and other related modules. We produced some design products such as data flow diagram, function diagram, etc. We expect that the proposed context awareness system will be embedded in the integrated platform and used for an active management strategy of urban facilities.

MR Angiography with Simultaneous Data Acquisition of Arteries and Veins(SAAV) Method and Artery-Vein Color Mapping in 0.3T MRI System (0.3T MRI 시스템에서의 동.정맥 동시 획득을 위한 자기공명 혈류 영상 기법(SAAV)과 동.정맥 color mapping)

  • 조종운;조지연;서성만;은충기;문치웅
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.275-280
    • /
    • 2003
  • The method of simultaneous data acquisition of arteries and veins(SAAV) was suggested to obtain MR angiography of arteries and veins at 0.3T low filed MRI system (Magfinder, AlLab. Korea). Two separated artery- and vein-images were put together using AVCM(Artery-Vein Color Mapping) algorithm and presented in the same image. In this study, artery- and vein-separated angiograms of volunteer's neck were obtained. Two dimensioal blood-enhanced images wre sequentially obtained using SAAV pulse sequence based on time-of-flight(TOF) method with flow compensation. Imaging parameters were TR/TE=70/12msec. FOV=230mm, slice thickness = 3mm, flip angle=90$^{\circ}$, matrix size=256${\times}$256${\times}$64mm. TSat TH/SPA=15/20mm, Ts_v=10msec and Ts_a=40ms. 3D MRA images were reconstructed using the maximum intensity projection(MIP) and the artery-vein color mapping(AVCM) algorithm. This study showed good possibility of clinical applications of MRA in 0.3T which provides valuable diagnostic information of clinical vascular diseases.

Study on the Gastrodiae rhizoma as Applications in YackSun(Medicated Diets) for Preventing of Cerebral Cardiovascular Disease (1) Effects of Gastrodiae rhizoma on the Regional Cerebral Blood Flow and Blood Pressure (천마를 이용한 뇌혈관성 질환의 예방을 위한 양생약선(養生藥膳)의 개발을 위한 연구 (1) 천마 열수 추출물이 국소 뇌혈류량과 혈압에 미치는 영향)

  • Park Sung-Hye;Shin Mee-Kyung;Han Jong-Hyun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.15 no.3
    • /
    • pp.283-291
    • /
    • 2005
  • This study was penonned to provide basic data that predict the usefulness of Gastrodiae rhizoma as food materials for oriental medicinal cuisine(YakSun). We measured the changes of regional cerebral blood flow(rCBF) and blood pressure(BP) in rats, following the intravenous injection of Gastrodiae rhizoma water extract The measurement was continually monitored by laser-doppler flowmeter and pressure transducer in anesthetized adult Sprague-Dawley rats for about two to two and half hours through the data acquisition system composed of MacLab and Macintosh computer. The results of this experiment were as follows. Gastrodiae rhizoma increased the changes of rCBF in rats significantly. The rCBF of Gastrodiae rhizoma did not change by pretreated propranolol, atropin, methylene blue and indomethacin. But the rCBF of Gastrodiae rhizoma was increased by pretreated L-NNA. Gastrodiae rhizaoma decreased the changes of BP significantly. The BP of Gastrodiae rhizoma did not change by pretreated propranolol, atropin, methylene blue and indomethacin. But the BP of Gastrodiae rhizoma was decreased by pretreated L-NNA. These results indicated that Gastrodiae rhizoma might increase the rCBF and the BP which related to nitric oxide synthesis. Also these results indicate that Gastrodiae rhizoma can be used as a safe and clinically applicable to diet therapy of cerebral cardiovascular disease.

  • PDF

Effects of Lumbricus on the Change of Cerebral Hemodynamics in Rats (구인(蚯蚓)이 흰쥐의 뇌혈류역학 변화에 미치는 효과)

  • Lee, Chong-Woo;Kwon, Young-Dal;Yeom, Seung-Ryong;Song, Yung-Sun
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.1
    • /
    • pp.65-74
    • /
    • 2008
  • Objectives : This experimental study was designed to investigate the effects of Lumbricus extract (LE) on the changes in regional cerebral blood flow (rCBF) and mean arterial blood pressure (MABP) in normal rats, and further to determine the mechanism of action of LE. Methods : The changes of rCBF were observed by Laser-Doppler flowmetry (LDF) and the changes of MABP were recorded by a data acquisition system assembled with MacLab and Macintosh. Results : LE significantly increased rCBF in a high dosage(10.0 mg/kg, i.p), but MABP was somewhat increased as compared with baseline. This result suggests that LE significantly increased rCBF by dilating pial arterial diameter. Increase of LE-induced rCBF was significantly inhibited by pretreatment with indomethacin (1 mg/kg, i.p), an inhibitor of cyclooxygenase, but was not significantly inhibited by pretreatment with methylene blue ($10{\mu}g/kg$, i.p), an inhibitor of guanylate cyclase. Conclusions : LE increased rCBF by dilating pial arterial diameter, and the action of this response was mediated by cyclooxygenase.

Effects of Flos Sophora japonica Extract on the Changes of Cerebral Hemodynamics

  • Rha, Young-Ah;Lee, Woo-Sik;Park, Sung-Jin
    • Culinary science and hospitality research
    • /
    • v.20 no.5
    • /
    • pp.67-70
    • /
    • 2014
  • The purpose of this study was to measure the changes of regional cerebral blood flow(rCBF) and blood pressure(BP) in rats, following the intravenous injection of Flos Sophora japonica L.(FSJ) water extract. The measurement was continually monitored by Laser-Doppler Flowmeter and pressure transducer in anaesthetized adult Sprague-Dawley rats for 2 hours to 2 hours and a half through the data acquisition system. FSJ increased the changes of rCBF in rat significantly. The rCBF of FSJ did not change by pretreated propranolol, atropine, L-NNA($N^G$-nitro-L-argininine) and indomethacin. But the rCBF of Flos Sophora japonica L. was increased by pretreated methylene blue. FSJ decreased the changes of BP, significantly. The BP of FSJ did not change by pretreated propranolol, atropine, L-NNA and indomethacin. But the BP FSJ was decreased by pretreated methylene blue. There results indicated that FSJ can increase the rCBF and decrease the BP, that is related to guanylyl cyclase activity.

Velocity Profiles and Entrance Length of Transitional Oscillatory Flows in the Entrance Region of a Square Duct (정(正)4각(角)덕트 입구영역(入口領域)에서 천이(遷移) 진동유동(振動流動)의 입구(入口)길이와 속도분포(速度分布))

  • Choi, J.H.;Choi, B.M.;Yoo, Y.T.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.3
    • /
    • pp.275-287
    • /
    • 1993
  • The flow characteristics of the transitional oscillatory flows are investigated analytically and experimentally in the entrance region of a square duct. The systems of conservation equations are analytically solved by linearizing the non-linear convective terms for the developing transitional oscillatory flows in a square duct. The analytical solutions are obtained in the form of infinite series for the velocity profiles. The experimental study for the air flow in a square duct is carried out to measure the velocity profiles and waveforms by using a hot-wire anemometer with the data acquisition and processing systems. The theoretical and experimental results provide the major characteristics of the developing transitional oscillatory flows, such as velocity profiles, velocity waveforms, and entrance length. The velocity profiles in the decelerating phase are larger than those in the accelerating phase for the developing transitional oscillatory flows. The correlations of the entrance length of the transitional oscillatory flows in a square duct are found to be $Le/Dh=K{\cdot}Re_{os}/2({\omega}^+)^2$, where K is 1.23 of an experimental constant.

  • PDF