• 제목/요약/키워드: Flow conditioner

검색결과 172건 처리시간 0.024초

실외기 shroud 형상 최적 설계 (Optimization of design parameters on the shroud of air conditioner outdoor unit)

  • 유기정;예휘열;이상봉;이관수;차우호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.453-458
    • /
    • 2009
  • This paper presents a numerical evaluation of the flow rate of air conditioner outdoor unit as function of shroud design parameters. To determine the optimal design parameters, we investigated the flow rate by changing bell mouth height, fan height, fan guide height, fan width. The evaluation of the relative priority of the design parameters was performed to choose three important parameters in order to use a response surface method. The flow rate of the optimum model, compared to that of the base model, was increased by about 6.25%.

  • PDF

R407C 및 R410B 적용 창문형 에어컨의 성능에 관한 실험적 연구 (An experimental study on the performance of a window system air-conditioner using R407C and R410B)

  • 김만회;신정섭;김권진
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.536-544
    • /
    • 1997
  • This study presents test results of a residential window system air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests was performed for the basic and liquid-suction heat exchange cycle in a psychrometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-line suction-line heat exchange cycle was also considered to improve the performance of the system. Test results were compared to those for the basic R22 system.

  • PDF

MILLING CHARACTERISTICS OF BROWN RICE USING A CONTINUOUS TYPE CONDITIONER

  • Song, D.B.;Han, K.Y.;Kim, S.T.;Choi, B.J.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.II
    • /
    • pp.423-429
    • /
    • 2000
  • The water conditioning experiments of brown rice were performed to verify the effect of brown rice conditioner and to decide the optimum operating variables for the conditioner. The initial moisture contents of 13-14%(wb) brown rice were used as experimental samples. The flow rate of brown rice passing through the conditioner was 2,940 kg/hr and water was supplied proportionally from 80 cc/min to 240 cc/min. The differences between expected and measured moisture contents were neglected except 0.25%(wb) of the maximum differences at 0.2920((cc/min)-water/(kg/min)'%-brown rice) of water supply rate. For the initial moisture contents of 13-14%(wb) brown rice, it was found that a proper water supply rate was 0.2415((cc/min)-water/(kg/min).%-brown rice) and the increments of whole rice was 2.3% compared to non conditioned ones. It was considered that the conditioning process did not influence the whiteness of milled rice because the whiteness differences between conditioned and non-conditioned milled rice were negligible.

  • PDF

열교환기가 공기조화용 터보팬의 성능에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Effect of heat exchanger on turbo fan for air conditioning)

  • 장승용;남임우;주원구;조강래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.615-618
    • /
    • 2002
  • Turbo-fan for ceiling cassette type air conditioner doesn't operate in general volute. It is operated by porous material, heat exchanger. Heat exchanger increases resistance of air conditioning system and disturbs exit-flow of impeller. Therefore it has some influences on impeller capacity. In this study, we want to how that influence of exchanger on impeller capacity for ceiling cassette type air conditioner. To research, we made circular case that didn't have asymmetric part unlike rectangular case. With and without heat exchanger we measured total pressure and static pressure of impeller and three-dimensional rear flow field From the result, a turbo fan , installed in the 35mm back of fan and operated in heat exchanger, experienced $2{\%}{\~}5{\%}$% total pressure loss over all flow rate. With heat exchanger impeller efficiency decrease as flow rate decrease when flow rate coefficient was below 0.18. Especially when flow rate coefficient was below 0.12, there was $20{\%}{\~}30{\%}$ decrease of impeller efficiency.

  • PDF

룸에어콘 실내기의 설계인자 변화에 따른 관류홴의 공력성능 연구 (Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Design Factors of an Indoor Room Air-Conditioner)

  • 김장권;정규조
    • 동력기계공학회지
    • /
    • 제9권3호
    • /
    • pp.33-38
    • /
    • 2005
  • The aerodynamic performance of a cross-flow fan is strongly influenced by the various design factors of a rear-guider and a stabilizer. The purpose of this paper is to investigate the effects of a rear-guider and a stabilizer on the aerodynamic performance of a cross-flow fan. The design factors considered in this paper are a rear-guider clearance, a stabilizer clearance, and a stabilizer setup angle, respectively. This experiment was carried out with a constant revolution number of 700 rpm in a cross-flow fan installed in the fan tester. The static pressure, flowrate, torque, and revolution number were measured in this paper. Also, the pressure coefficient and the efficiency were analysed according to the various assembly conditions using a stabilizer setup angle, a stabilizer clearance, and a rear-guider clearance in the indoor room air-conditioner.

  • PDF

리어가이더 선단각도에 따른 룸에어콘용 관류홴의 공력성능에 관한 실험적 연구 (Experimental Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Leading Angles of a Rear-Guider for a Room Air-Conditioner)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제17권3호
    • /
    • pp.35-43
    • /
    • 2013
  • Generally, the chassis of an indoor RAC is composed of a rear-guider and a stabilizer. The aerodynamic performance of a cross-flow fan is strongly influenced by the various design factors of the chassis of an indoor RAC. The purpose of this paper is to select the optimum design factors through the aerodynamic performance of a cross-flow fan. The design factors are the leading angle of a rear-guider (${\theta}_1$), a stabilizer setup angle(${\theta}_2$), a rear-guider clearance(${\epsilon}_1$), and a stabilizer clearance(${\epsilon}_2$), respectively. As a result, the optimum design factors of an indoor RAC can be presented as a combination of ${\theta}_1=33^{\circ}$, ${\theta}_2=55^{\circ}$, ${\epsilon}_1=6{\sim}8mm$, and ${\epsilon}_2=7mm$ through the analysis of a static pressure coefficient and a static pressure efficiency.

차량용 공조 팬의 소음 저감에 대한 실험적 연구 (Experimental Study on Noise Reduction of Fan for Automotive Air Conditioner)

  • 이진갑;정병훈
    • 한국산학기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.51-56
    • /
    • 2013
  • 본 논문은 철도 차량에 사용하는 라인 플로우 팬의 소음 저감을 위해 소음원을 규명하여 저감하는 실험적인 연구이다. 라인 플로우 팬의 소음은 공기 유동에 의한 난류성 유동 및 랜덤성 소음, 블레이드 통과 주파수(681Hz)의 소음, 모터 회전에 의한 로터의 불균형(28.4Hz)의 구조물 진동에 의한 소음 등 여러 요인에 의해 발생된다. 각각의 소음원에 대해 대책을 수립하여 하우징 가이드 각도 및 거리 조정, 유동 통로의 형상 변경, 로터 밸런싱을 통해 총 5.7dB(A)의 소음을 저감하였다.

리어가이더 곡률반경에 따른 룸에어콘용 관류홴의 공력성능에 대한 실험적 연구 (Experimental Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Curvature Radius of a Rear-Guider for a Room Air-Conditioner)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.36-44
    • /
    • 2013
  • The aerodynamic performance of a cross-flow fan is strongly influenced by the various design factors of a rear-guider and a stabilizer. The design factors considered in this paper are a rear-guider clearance, a stabilizer clearance, and a stabilizer setup angle, respectively. Also, these factors are given to the various diameter ratio between a basic circle and a impeller. The static pressure and the flowrate of a cross-flow fan were measured with a fan-tester. It could be found that the useful design factors with a good aerodynamic performance exist in the certain assembly conditions of an indoor RAC. Therefore, it could be known that a new published patent determining the easy design of an indoor RAC can be applied in a variety of goods.

자동차용 에어컨의 단품 성능에 관한 연구 (A Study on the Component Performance for Automotive Air Conditioner)

  • 이대웅;유성연
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.293-303
    • /
    • 2002
  • For successful design of component, performances of one-tank plate type evaporator, gas-liquid separation type condenser, swash plate type compressor and thermostatic expansion valve for automotive air conditioner are investigated experimentally. Heat transfer characteristics in the evaporator are examined by means of air temperature, relative humidity, air volume flow, outlet refrigerant pressure and superheat, and heat transfer characteristics in the condenser are examined by means of air temperature, air velocity and inlet refrigerant pressure. Pressure drops for both evaporator and condenser are measured arid empirical correlations are derived. Volumetric efficiencies and isentropic efficiencies for trio types of compressors with different capacity are measured and compared. Thermostatic expansion valve is tested to investigate the pressure variation according to temperature changes.