• Title/Summary/Keyword: Flow conditioner

Search Result 172, Processing Time 0.029 seconds

Study on Flow Structure inside Room Air Conditioner Using Visualization Technique (가시화기법을 이용한 룸 에어컨 내부의 유동 구조에 관한 연구)

  • Lee, Soo-Hong;Na, Seon-Uk;Kang, Geun;Ko, Han-Seo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2713-2717
    • /
    • 2008
  • Whole flow fields of a room air conditioner (RAC) have been visualized by a Particle Image Velocimetry (PIV) technique to analyze the flow structure with various inlet and outlet angles, and to control an eccentric vortex which affects an efficiency and noise of the RAC. A test model with 5 stages of a cross flow fan has been manufactured and a transparent acryl has been installed at the side of the test model for the PIV experiment. The inlet and outlet flows and the flow inside the cross flow fan have been analyzed by varying the inlet grill angles and outlet blade angles. The movement of the eccentric vortex has been investigated experimentally by developing the measurement technique for the inner flow field of the cross flow fan. From the visualization of the inner flows, the origins of the noise inside the RAC and the condensation points around the outlet parts of the cold air have been observed and the solution of the problems can be proposed in this study.

  • PDF

The Effect of Flow Rate into Room by Natural Convection in Air Conditioner Duct (공조기 덕트 내의 자연대류가 실내 유입유량에 미치는 영향)

  • 공태우;정한식;정효민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.160-166
    • /
    • 2001
  • A numerical analysis has been performed for natural convection in an air conditioner duct system. The governing equations were solved a finite volume method using a SIMPLE algorithm. In the calculation mode of duct, the room temperature was preserved at $25.0^{\circ}C$ and duct wall temperature had a temperature of 15, 20.0, 22.5, 23.75, 26.25, 27.5 30 and $35^{\circ}C$. The results of velocity vectors and contours have been represented for various parameters. Based on the numerical data, the relationships between temperature difference and flow rate into room was represented. In the case of $T_\gamma>T_\omega$, the equation for temperature difference and flow rate was $Q=0.0285\triangleT^0.4005$, and in the case of $T_\gamma>T_\omega$, the equation was $Q=0.0099\triangleT^0.4752$. The duct system has an important relation to room temperature and duct wall temperature.

  • PDF

Design of Centrifugal Impeller for Passenger Car by Flow Field Analysis (유동장 해석을 통한 승용차 원심 회전차의 형상 설계)

  • Lee, Dong-Ryul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.49-55
    • /
    • 2011
  • For the purpose of the enhancement of the air conditioner performance and fuel effciency, several cases of centrifugal impeller for passenger car air conditioner have been numerically analyzed by changing central angle of blades and length of outlet for shape optimization of the impeller. Commercial CFD program Fluent 6.3.26 has been used to compute velocity, temperature, pressure and turbulence intensity that can lead numerous results. The central angles of two blades and three cases of outlet length led 4~12% and 3.5~6.4% differences of velocity and flow rate, respectively. The velocity distribution near the blade surface was axisymmetric and had a maximum value of 22.19 m/s and velocity of the vertical direction of the impeller showed linear increase with horizontal direction. At case 3 of oultet length, there existed a a minimum pressure value of -133320 Pa.

Study on Measurement of Flow Distribution for Design of Room Air Conditioner with High-Efficiency (고효율 룸 에어컨 설계를 위한 유동 분포 측정에 관한 연구)

  • Lee, Soo-Hong;Na, Seon-Uk;Kang, Geun;Ko, Han-Seo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.853-856
    • /
    • 2009
  • Test models which have geometrical similarities with a real room air conditioner (RAC) have been manufactured including visualization windows so that a laser beam can pass through a cross flow fan. Then, flow distributions of the RAC have been investigated using a visualization technique such as a Particle Image Velocimetry (PIV) to analyze an efficiency and noise of the RAC. Pitot tubes have also been used to measure the flow velocity inside the RAC with various positions to confirm the measurement accuracy of the PIV technique. The measured flow velocities have been analyzed and new designs of the RAC have been proposed to improve the efficiency and to reduce the noise for the RAC in this study.

  • PDF

Development of Simulation Program of Automotive Engine Cooling System (자동차 엔진냉각계의 해석 프로그램의 개발)

  • 배석정;이정희;최영기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.11
    • /
    • pp.943-956
    • /
    • 2003
  • A numerical program has been developed for the simulation of automotive engine cooling system. The program determines the mass flow rate of engine coolant circulating the engine cooling system and radiator cooling air when the engine speed is adopted by appropriate empirical correlation. The program used the method of thermal balance at individual element through the model for radiator component in radiator analysis. This study has developed the program that predicts the coolant mass flow rate, inlet and outlet temperatures of each component in the engine cooling system (engine, transmission, radiator and oil cooler) in its state of thermal equilibrium. This study also combined the individual programs and united into the total performance analysis program of the engine cooling system operating at a constant vehicle speed. An air conditioner system is also included in this engine cooling system so that the condenser of the air conditioner faces the radiator. The effect of air conditioner to the cooling performance, e.g., radiator inlet temperature, of the radiator and engine system was examined. This study could make standards of design of radiator capacity using heat rejection with respect to the mass flow rate of cooling air. This study is intended to predict the performance of each component at design step or to simulate the system when specification of the component is modified, and to analyze the performance of the total vehicle engine cooling system.

Flux Analysis of Air-conditioner Coupling (에어컨디셔너의 냉매배관을 연결하는 커플링의 유동해석)

  • Lee, Su-Yul;Kim, Woo-Seung;Cho, Soo;Sung, Uk-Joo;Park, Hee-Mun;Sim, Kyung-Jong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1031-1036
    • /
    • 2009
  • This study is intended to identify how quick disconnect coupling which connects with refrigerant piping of air-conditioner using R-22 refrigerant has effect on characteristics of flux. in the case where the air-conditioner installs utilizes quick disconnect coupling, COP has an effect on the quantity of cooling load because of changing flow rate and physical properties of refrigerant which flow into an entrance of expansion valve from coupling. Variation of flow rate can be regulated by changing expansion-contraction angle; $\alpha$ of an entrance and an exit of coupling. In this study, quick disconnect coupling is presented flow of coupling by using FLUENT as heat flow program. To have an effect on the expansion entrance valve, and by changing expansion-contraction angle; $\alpha$ of an entrance and an exit

  • PDF

Evaluation of the operating reliability on the concurrent heating-cooling system air conditioner for different refrigerant flow rates with high-head and long-line conditions (동시냉난방 시스템 에어컨의 냉매량 변화에 따른 고낙차 장배관 운전 신뢰성 평가)

  • Lee, Seung-Chan;Kim, Tae-An;Tae, Sang-Jin;Jung, Gyoo-Ha;Moon, Je-Myung;Kim, Youn-Jea
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.304-309
    • /
    • 2008
  • The heating and cooling performances of system multi-air conditioner for various refrigerant flow rates with high-head and long-line conditions are experimentally investigated. The maximum head and tube length were 110 m and 1000 m, and the two different adjustments of refrigerant flow rates were +20 % and -20 %, respectively. The experimental system was composed of 4 outdoor units with module systems, and 13 indoor units which were joined with the mode change unit by single-tube circuit. Field tests without indoor and outdoor temperature control were performed in a general office building with two different refrigerant flow rates. Especially, the oil level in the compressor was normally maintained at the safety zone. Experimental results were prepared on the p-h diagram.

  • PDF

Analysis on Performance of Axial Flow Fan for Outdoor Unit of Air-conditioner: Noise Characteristics (에어컨 실외기용 축류홴의 성능에 관한 연구: 소음 특성)

  • Kim, Yong-Hwan;Lee, Jang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.5
    • /
    • pp.29-34
    • /
    • 2010
  • In this paper, aerodynamic noise of axial flow fans for outdoor unit of air-conditioner was analyzed by both experiment and numerical simulation. The three-dimensional incompressible turbulent flow was predicted by the commercial computational fluid dynamics code SC/Tetra, while the aeroacoustic noise of an axial flow fan was predicted by FlowNoise. Computations and experiments were performed with two types of axial flow fans, in which very different noise source distributions were presented. The results obtained from this study are expected to show the way to reduce the noise of axial flow fans in industrial applications.

Analysis on Performance of Axial Flow Fan for Outdoor Unit of Air-conditioner: Flow Characteristics (에어컨 실외기용 축류홴의 성능에 관한 연구: 유동 특성)

  • Kim, Yong-Hwan;Jeong, Jin-Hwan;Lee, Jang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.6
    • /
    • pp.30-35
    • /
    • 2010
  • The aerodynamic performance of axial flow fans for outdoor unit of air-conditioner is investigated by numerical and experimental approaches in this study. The pressure drop and volumetric flow rate are compared each other in several different conditions and fan speeds. It is shown that the predicted fan performances are quite well matched with the experimental results. It is also shown that the curvature of the fan arc and hub height have significant influences on the flow distribution after hub. By the results of this study, it can be suggested that several ways to improve the aerodynamic performance of the axial flow fan can be found using the numerical analysis.

Source localization of impact noise on an indoor unit of air-conditioner (에어컨 실내기에서 발생하는 충격 소음원의 위치 추정)

  • 최영철;김양한;이종구;김구영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.324-329
    • /
    • 2003
  • An air-conditioner has various noise sources such as cooling fan noise, pumping noise, flow noise and impact noise. Among these, impact noise is the most unpleasant source. This is because the noise is produced in indoor unit of air-conditioner. To control the noise source effectively, first we must identify the noise sources. When we identify impact noise source, the measurement have to be carried out simultaneously. So we use beamforming method that requires less measurement points than intensity method and acoustic holography. The objective of this paper is to estimate the location of impact source. This objective can be achieved by using minimum variance cepstrum that is able to detect impulse embedded in noise. In this study, modified beamforming method based on cepstrum domain is proposed. Then this method applied to air-conditioner noise sources which produce impact noise.

  • PDF