• 제목/요약/키워드: Flow Tube

검색결과 2,190건 처리시간 0.026초

평균 양방향 튜브의 설계 최적화를 위한 FLUENT 코드해석 (FLUENT Code Analyses for Design Optimization of an Average Bi-directional Flow Tube)

  • 강경호;윤병조;어동진;백원필
    • 한국유체기계학회 논문집
    • /
    • 제8권4호
    • /
    • pp.14-19
    • /
    • 2005
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. 3-dimensional steady state flow analyses using FLUENT 5.4 code were performed to validate the application of the average bi-directional flow tube in case of water and air flow. In this study, sensitivity studies have been performed to optimize the design features of the average bi-directional flow tube which can be applied for the various experimental conditions. For Re numbers above 1000, the k values are nearly constant regardless of the Re numbers and flow types and calculation results and experimental data coincides quite well. The current FLUENT calculation results suggest that linearity of the k values in various design features of the average BDFT is highly promising, which means that it is quite reasonable to select the typical design of the average BDFT for the convenience of the experimental conditions.

평균 양방향 튜브의 설계 최적화를 위한 FLUENT코드해석 (FLUENT Code Analyses for Design Optimization of an Average Bi-directional Flow Tube)

  • 강경호;윤병조;어동진;백원필
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.180-186
    • /
    • 2004
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. 3-dimensional steady state flow analyses using FLUENT 5.4 code were performed to validate the application of the averagebi-directional flow tube in case of water and air flow In this study, sensitivity studies have been performed to optimize the design features of the average hi-directional flow tube which can be applied for the various experimental conditions. For Re numbers above 1000, the k values are nearly constant regardless of the Re numbers and flow types and calculation results and experimental data coincides quite well. The current FLUENT calculation results suggest that linearity of the k values in various design features of the average BDFT is highly promising, which means that it is quite reasonable to select the typical design of the average BDFT for the convenience of the experimental conditions.

  • PDF

다공튜브 오리피스 면적비 변화가 출구유동에 미치는 영향 (Effect of the Orifice Area Ratio on the Exit Flow of a Multi-Perforated Tube)

  • 이상규;이지근
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.317-323
    • /
    • 2013
  • A multi-perforated tube indicates the existence of multiple holes of various shapes on the surface of a long cylinder-type or rectangular tube, and a hole installed on the surface is called an orifice, as it is relatively small in size, compared with the surface area of the tube. In this study, the flow characteristics of a circular multi-perforated tube with many orifices on the surface were investigated experimentally and numerically. The volume flowrate issuing from each orifice, discharge angle, effective flow area ratio, and the flow fields around the orifices were measured and visualized, with the variation of the orifice area ratio, at the same blockage ratio. The volume flowrate distributions along the flow direction of the multi-perforated tube tends to be more uniform, as larger orifices were positioned at the inlet side of the multi-perforated tube, compared with no orifice area change along the flow direction.

MEASUREMENT OF THE SINGLE AND TWO PHASE FLOW USING A NEWLY DEVELOPED AVERAGE BIDIRECTIONAL FLOW TUBE

  • Yun, Byong-Jo;Euh, Dong-Jin;Kang, Kyunc-Ho;Song, Chul-Hwa;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • 제37권6호
    • /
    • pp.595-604
    • /
    • 2005
  • A new instrument, an average BDFT (Birectional Flow Tube), was proposed to measure the flow rate in single and two phase flows. Its working principle is similar to that of the Pilot tube, wherein the dynamic pressure is measured. In an average BDFT, the pressure measured at the front of the flow tube is equal to the total pressure, while that measured at the rear tube is slightly less than the static pressure of the flow field due to the suction effect downstream. The proposed instrument was tested in air/water vertical and horizontal test sections with an inner diameter of 0.08m. The tests were performed primarily in single phase water and air flow conditions to obtain the amplification factor(k) of the flow tube in the vertical and horizontal test sections. Tests were also performed in air/water vertical two phase flow conditions in which the flow regimes were bubbly, slug, and churn turbulent flows. In order to calculate the phasic mass flow rates from the measured differential pressure, the Chexal drift-flux correlation and a momentum exchange factor between the two phases were introduced. The test results show that the proposed instrument with a combination of the measured void fraction, Chexal drift-flux correlation, and Bosio & Malnes' momentum exchange model could predict the phasic mass flow rates within a $15\%$ error. A new momentum exchange model was also proposed from the present data and its implementation provides a $5\%$ improvement to the measured mass flow rate when compared to that with the Bosio & Malnes' model.

중수로 기기냉각수 열교환기 내부 유동 해석 (Analysis of Internal Flow for Component Cooling Water Heat Exchanger in CANDU Nuclear Power Plants)

  • 송석윤
    • 한국압력기기공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.33-41
    • /
    • 2012
  • The component cooling water heat exchangers are critical components in a nuclear power plant. As the operation years of the heat exchanger go by, the maintenance costs required for continuous operation also increase. Most heat exchangers have carbon steel shells, tube support plates and flow baffles. The titanium tube is susceptible to flow induced vibration. The damage on carbon steel tube support rod and titanium tube around cooling water entrance area is inevitable. Therefore, analysis of internal flow around the component cooling water entrance and tube channel is a good opportunity to seek for failure prevention practice and maintenance method. The numerical study was carried out by FLUENT code to find out the causes of tube failure and its location.

공기-횡 유동장에 놓인 유연성 실린더 관군의 유체탄성 불안정 (Fluidelastic Instability of Flexible Cylinders in Tube Bundle Subjected to Cross Air-flow)

  • 심우건
    • 한국소음진동공학회논문집
    • /
    • 제17권6호
    • /
    • pp.498-506
    • /
    • 2007
  • Using wind tunnel, experimental approaches were employed to investigate fluidelastic instability of tube bundles, subjected to uniform cross flow. There are several flow-induced vibration excitation mechanisms, such as fluidelastic instability, periodic wake shedding resonance, turbulence-induced excitation and acoustic resonance, which could cause excessive vibration in shell-and tube heat exchanges. Fluidelastic is the most important vibration excitation mechanism for heat exchanger tube bundles subjected to cross flow. The system comprised of cantilevered flexible cylinder(s) and rigid cylinders of normal square array, In order to see the characteristics of flow in tube bundles, particle image velocimetry was used. From a practical design point of view, Fluidelastic instability may be expressed simply in terms of dimensionless flow velocity and dimensionless mass-damping. The threshold flow velocity for dynamic instability of cylinder rows is evaluated and the data for design guideline is proposed for the tube bundles of normal square array.

Effect of Flow Direction on Two-Phase Flow Distribution of Refrigerants at a T-Junction

  • Tae Sang-Jin;Cho Keum-Nam
    • Journal of Mechanical Science and Technology
    • /
    • 제20권5호
    • /
    • pp.717-727
    • /
    • 2006
  • The present study experimentally investigated the effect of flow direction and other flow parameters on two-phase flow distribution of refrigerants at a T-junction, and also suggested a prediction model for refrigerant in a T-junction by modifying previous model for air-water flow. R-22, R-134a, and R-410A were used as test refrigerants. As geometric parameters, the direction of the inlet or branch tube and the tube diameter ratio of branch to inlet tube were chosen. The measured data were compared with the values predicted by the models developed for air-water or steam-water mixture in the literature. We propose a modified model for application to the reduced T-junction and vertical tube orientation. Among the geometric parameters, the branch tube direction showed the biggest sensitivity to the mass flow rate ratio for the gas phase, while the inlet quality showed the biggest sensitivity to the mass flow rate ratio among the inlet flow parameters.

Internal Flow Characteristics in the Draft Tube of a Francis Turbine

  • Wei, Qingsheng;Zhu, Baoshan;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.618-626
    • /
    • 2012
  • Suppression of abnormal flow phenomena in the Francis hydro turbine is very important to improve the turbine performance. Especially, as cavitation and cavitation surge makes serious problems when the turbine is operated in the range of partial flow rate, optimum method of suppressing the abnormal flow characteristics is required necessarily. Moreover, as swirl flow in the draft tube of the Francis turbine decreases pressure at the inlet of the draft tube, suppression of the swirl flow can be an useful method of suppressing the occurrence of cavitation. In order to clarifying the possibility of suppressing the swirl flow by J-Groove in the draft tube, a series of CFD analysis has been conducted in the range of partial load, designed condition and excessive flow rate of a Francis turbine. A kind of J-Groove is designed and applied to the draft tube of the Francis hydro turbine model. The pressure contours, circumferential velocity vectors and vortex core regions in the draft tube are compared by the conditions with or without J-Groove. In addition, a group of data about the velocity in the draft is presented to show the influence of J-Groove.

하나로 원형 조사공의 안내관 제트유동 억제에 대한 해석 (THE ANALYTIC ANALYSIS OF SUPPRESSING JET FLOW AT GUIDE TUBE OF CIRCULAR IRRADIATION HOLE IN HANARO)

  • 박용철;우상익
    • 한국전산유체공학회지
    • /
    • 제10권2호
    • /
    • pp.1-6
    • /
    • 2005
  • The HANARO, a multi-purpose research reactor of 30 MWth, open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. The HANARO is composed af inlet plenum, grid plate, core channel with flow tubes and chimney. The reactor core channel is located at about twelve meters (12 m) depth of the reactor pool and cooled by the upward flow that the coolant enters the lower inlet of the plenum, rises up through the grid plate and the core channel and comes out from the outlet of chimney. A fission moly guide tube is extended from the reactor core to the top of the reactor chimney for easily loading a fission moly target under the reactor normal operation. But active coolant through the core can be quickly raised up to the top of the chimney through the guide tube by jet flow. This paper describes an analytical analysis that is the study of the flow behavior through the guide tube under reactor normal operation and unloading the target. As results, it was conformed through the analysis results that the flow rate, reduced to about fourteen kilogram per second (14 kg/s) from the original flow rate of sixteen point three kilogram per second (16.3 kg/s) did not show the guide tube jet.

단상 및 이상유동 유량 계측을 위한 평균 양방향 유동 튜브 개발 (Development of an Average Bi-directional Flow Tube for the Measurement of Single and Two phase Flow Rate)

  • 윤병조;강경호;어동진;백원필
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.172-179
    • /
    • 2004
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. The suggested instrumentation was tested in the air-water vertical test section which has 80mm inner diameter and 10m length. The flow tube was installed at 120 of L/D from inlet of test section. From the test, single air and water flow rate was measured successfully. For the emasurement of two phase flow rate, Chexal drift-flux correlation was used. In the test a new correlation of momentum exchange factor was suggested. The test result shows that the suggested instrumentation using the measured void fraction and Chexal drift-flux correlation can predict the mass flow rates within $10\%$ error of measured data.

  • PDF