• Title/Summary/Keyword: Flow Table

Search Result 337, Processing Time 0.026 seconds

Design optimization of vibration isolation system through minimization of vibration power flow

  • Xie, Shilin;Or, Siu Wing;Chan, Helen Lai Wa;Choy, Ping Kong;Liu, Peter Chou Kee
    • Structural Engineering and Mechanics
    • /
    • v.28 no.6
    • /
    • pp.677-694
    • /
    • 2008
  • A vibration power minimization model is developed, based on the mobility matrix method, for a vibration isolation system consisting of a vibrating source placed on an elastic support structure through multiple resilient mounts. This model is applied to investigate the design optimization of an X-Y motion stage-based vibration isolation system used in semiconductor wire-bonding equipment. By varying the stiffness coefficients of the resilient mounts while constraining the dynamic displacement amplitudes of the X-Y motion stage, the total power flow from the X-Y motion stage (the vibrating source) to the equipment table (the elastic support structure) is minimized at each frequency interval in the concerned frequency range for different stiffnesses of the equipment table. The results show that when the equipment table is relatively flexible, the optimal design based on the proposed vibration power inimization model gives significantly little power flow than that obtained using a conventional vibration force minimization model at some critical frequencies. When the equipment table is rigid enough, both models provide almost the same predictions on the total power flow.

Environmental Change of Groundwater due to Urbanization (도시화(都市化)에 의한 지하수환경(地下水環境)의 변화(變化))

  • KIM, Su Won;BAE, Sang Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.1
    • /
    • pp.69-77
    • /
    • 1996
  • To evaluate the change of the groundwater flow and the water table response resulting from urbanization, two cases of the transient three-dimensional numerical simulations were performed. Variations of the groundwater flow system caused by withdrawals were analyzed. Two cases of infiltration rates were applied in this study to verify the water table changes. One is the rate under the circumstance during 1994 and the other is the revised rate. The numerical results from this study indicated that groundwater flow was influenced by human impacts. Groundwater flow has been concentrated to Taegu Textile Complex area where had large amount of pumping. Water table so far decreased -2.76m a year due to withdrawals. Water tables of many points were increased more than 30cm when the surface was reformed by infiltrating the rainfall. It was appeared that the improvement of surface to recharge the precipitation was very important to preserve and manage for the groundwater.

  • PDF

Coloration Analysis of Korean Table Settings (한식상차림의 색채분석 연구)

  • Lee, Hyeran;Kim, Hyewon;Cho, Wookyoun
    • Journal of the Korean Society of Food Culture
    • /
    • v.28 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • The purpose of this study is to obtain basic materials to complement the 'time series table serving' by analyzing external color elements. We selected traditional Korean restaurants in two five-star hotels and two famous traditional Korean style restaurants and analyzed their colors and the coloration of the Korean table settings. The results are as follows. By using strong luminosity contrast, restaurant A made its customer focus on the food and used red as the principal point (highlighted) color. Desserts, which have small dimensions, were served in 'Buncheong' ware with 'bakji' method, which has strong contrast; this broke the color balance. The use of small patterned dishes with 'johwa' method would achieve color harmony. Restaurant B used a stronger color for the tables than the foods, making the point color inconspicuous. Lowering the brightness and saturation of the table color would be beneficial. In restaurant C, thick green napkins provided the point color, making the atmosphere of the restaurant dull and dark and interfering with the overall bright atmosphere of the restaurant. Using lower saturation, high luminosity, and yellowish colors would bring harmony to the overall atmosphere. In restaurant D, the point colors were divided into three groups; their diversification during the entire course of the meal made the flow of the meal more natural. However, the use of the violet color, which gives a cold feeling, in the middle of the meal courses broke the overall flow of warm color in the meal. Considering the already-present contrast between red and green, it would be better not to use the violet chrysanthemum in the course of the meal. As mentioned above, there are several issues in terms of the color arrangement, the usage of table pads, and the natural flow of colors. Those issues indicate the necessity for an overall plan for the banquet table set-up in terms of color.

A Study on the Trapezoidal Cutthroat Flumes for Measuring Flow in Open-Channels (개수로의 유량 측정을 위한 제형 Cutthroat Flume에 관한 연구)

  • 윤주상;정하우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.19 no.4
    • /
    • pp.4533-4543
    • /
    • 1977
  • The purpose of this study was to investigate and compare flow discharges of rectangular, V-notch and trapezoidal type of cutthrooat flumes, and the published data for trapezoidal parshall flumes. And the trapezoidal cutthroat flumes were also compared in their accuracy of discharge measurements for various convergence ratios in the inlet section and divergence ratios in the outlet section. Five flumes were studied, and all the flumes were 45cm long with flat-bottom and were made of well-finished transparent acryl plate of 3mm thickness. One rectangular, one V-notch and three trapezoidal types were numbered 1 to 5 as shown in Fig. III-1. The measured depth of water was ranged from 5 to 20cm. The results obtained in this study are summarized as follows: 1. The general discharge equations for tested prototypes are listed for free flow in Table IV-1 and for submergence flow in Table IV-4. 2. In both free and submerged flow, the accuracy of the discharge formula obtained by this test is highly significant at 1% level as shown in Table IV-2 and Table IV-6. The accuracy of disharges measured depends upon the convergence and divergence ratios in the trapezoidal types: the less the ratios of convergence as well as divergence, the lower the accuracy. 3. Submergence ratios tend to increase in the order of flume number except flume No. 4. This implies that trapezoidal cutthroat flumes are more acceptable than rectangular or V-notch ones for free flow. 4. The transition submergence for the trapezoidal Parshall flumes ranges from 80-85 percent, which is slightly higher than the tested flume. However, the trapezoidal cutthroat flume No. 5 has higher transition submergence ratio, ranging from 73-78 percent, than other trapezoidal ones. The difference between the trapezoidal Parshall flumes and the trapezoidal cutthroat flumes in transition submergence seems small enough to be ignored in their field use. 5. Trapezoidal cutthroat flume is simple and economical to construct in existing openchannels whose shapes are generally trapezoidal. In order to obtain the best rating accuracy, flume No. 3 among the tested trapezoidal types is recommended, because it shows the highest accuracy for both free and submerged flow.

  • PDF

UDP Flow Entry Management for Software-Defined Networking (사용자 정의 네트워크를 위한 사용자 데이터그램 프로토콜 플로우 엔트리 관리 기법)

  • Choi, Hanhimnara;Raza, Syed Muhammad;Kim, Moonseong;Choo, Hyunseung
    • Journal of Internet Computing and Services
    • /
    • v.22 no.2
    • /
    • pp.11-17
    • /
    • 2021
  • Software-defined networking provides a programmable and flexible way to manage the network by separating the control plane from data plane. However, the limited switch memory restricts the number of flow entries in the flow table used to forward packets. This leads to flow table overflow and flow entry reinstallation, which severely degrade the network performance. Therefore, this paper proposes a comprehensive policy for timely eviction of inactive flow entries to optimally maintain flow tables usage. In particular, statistics of user datagram protocol flow entries are periodically sampled to enable the inactive entries to be evicted early. Through traffic-based experiments, we found that the proposed system reduces the number of overflow occurrences and flow entries reinstallation compared to the random and FIFO policies.

ESTIMATION OF LOCAL LIQUID FILM THICKNESS IN TWO-PHASE ANNULAR FLOW

  • Lee, Bo-An;Yun, Byong-Jo;Kim, Kyung-Youn;Kim, Sin
    • Nuclear Engineering and Technology
    • /
    • v.44 no.1
    • /
    • pp.71-78
    • /
    • 2012
  • In many semi-empirical analyses of flow boiling heat transfer, an annular flow is often assumed as a model flow and the local liquid film thickness is a key parameter in the analysis. This work considers a simple electrical conductance technique to estimate the local liquid film thickness in two-phase annular flows. In this approach, many electrodes are mounted flush with the inner wall of the pipe. Voltage differences between two neighboring electrodes for concentric annular flows with various liquid film thicknesses are obtained before the main experiments and logged in a look-up table. For an actual application in the annual flow, voltage differences of neighboring electrodes are measured and then corresponding local film thicknesses are determined by the interpolation of the look-up table. Even though the proposed technique is quite simple and straightforward, the numerical and static phantom experiments support its usefulness.

Attitudes Estimation for the Vision-based UAV using Optical Flow (광류를 이용한 영상기반 무인항공기의 자세 추정)

  • Jo, Seon-Yeong;Kim, Jong-Hun;Kim, Jung-Ho;Cho, Kyeum-Rae;Lee, Dae-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.4
    • /
    • pp.342-351
    • /
    • 2010
  • UAV (Unmanned Aerial Vehicle) have an INS(Inertial Navigation System) equipment and also have an electro-optical Equipment for mission. This paper proposes the vision based attitude estimation algorithm using Kalman Filter and Optical flow for UAV. Optical flow is acquired from the movie of camera which is equipped on UAV and UAV's attitude is measured from optical flow. In this paper, Kalman Filter has been used for the settlement of the low reliability and estimation of UAV's attitude. Algorithm verification was performed through experiments. The experiment has been used rate table and real flight video. Then, this paper shows the verification result of UAV's attitude estimation algorithm. When the rate table was tested, the error was in 2 degree and the tendency was similar with AHRS measurement states. However, on the experiment of real flight movie, maximum yaw error was 21 degree and Maximum pitch error was 7.8 degree.

Table Flow Evaluation of CNT-Mixed Fiber Reinforced Cement Composite by Dispersion Method (분산방법에 따른 CNT를 혼입한 섬유보강 시멘트복합체의 유동성 평가)

  • Kim, Moon-Kyu;Kim, Gyu-Yong;Pyeon, Su-Jeong;Choi, Byung-Cheol;Park, Jun-Young;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.95-96
    • /
    • 2023
  • In this study, the table flow of fiber reinforced cement composites mixed with CNTs dispersed differently according to the dispersion method was evaluated. The mixture was composed of plain mixture according to the presence or absence of ultrasonic dispersion and PCE-based dispersants A and B of 0.5% and 1.0%, respectively, CNT was mixed with 0.03% of cement weight and fiber was mixed with 1.5% of total volume. As a result of the experiment, NC-A0.5 showed a fluidity similar to that of P without CNT. The fluidity of NC-A0.5 and P-N showed a similar tendency, which is considered to be due to the distribution of evenly dispersed CNT particles without agglomeration between cement particles due to the dispersant. NC-B0.5 showed a similar level of firmness to P-U, but after hitting 250 mm, B Agent seems to have a significant effect on liquidity improvement.Both NC-A1.0 and NC-B1.0 seem to have increased flow due to excessive dispersion.

  • PDF

Scientific Appreciation of Groundwater in the Hydrologic Cycle. - Some Experimental Results Concerning Rapid Water Table Response to Surface Phenomena.

  • Kayane, Isamu
    • Water for future
    • /
    • v.22 no.3
    • /
    • pp.289-298
    • /
    • 1989
  • A review is made of transient phenomena ralation to flow in the vadose zone. Reviewed topics include rapid water table response to rainfall, pulsating flow due to pressure perturbations in the vasoes zone, and the wave-like propagation of increased soil moisture caused by intermittent rainfall. As a basis of interpreting these phenomena, zoning of the vadose zone into a residual water zone, an unsaturated capillaty zone, and a saturated capillary zone are proposed. Possible implications with respect to hydrological processes relating to these phenomena are discussed.

  • PDF

Simulations of the Flow and Distribution of LNAPL in Heterogeneous Porous Media under Water Table Fluctuation Condition (불균질한 다공성 매질에서의 지하수위 변동을 고려한 저밀도 비수용성유체(LNAPL)의 흐름 모의)

  • 천정용;이진용;이강근
    • The Journal of Engineering Geology
    • /
    • v.13 no.1
    • /
    • pp.51-65
    • /
    • 2003
  • A series of numerical simulations were carried out using STOMP( Subsurface Transport over Multiple Phase) simulator. The flow and distribution of LNAPL were analyzed in homogeneous fine and coarse sand. Vertical movement of LNAPL is faster in the coarser sand. But the total volume of LNAPL retained in the unsaturated zone is larger in the finer sand. A fine layer in the coarse sand domain is also simulated. The results showed that the retained LNAPL volume and shape are highly influenced by the Position of the fine layer. Flow and distributions of LNAPL were simulated when there were heterogeneous lenses in the sand domain. Water table fluctuation was also considered. In these cases, it was found that the heterogeneous lens was a barrier to LNAPL flow, and water table fluctuation stimulated the downward movement of retained LNAPL. The LNAPL flow and distribution observed in these numerical experiments show that in the subsurface environment, the behaviors of LNAPL highly depend on heterogeneities of unsaturated zone and the dynamic hydrogeologic condition such as water table fluctuation. These results can explain some of the complexity of LNAPL flow and distribution Patterns in LNAPL contaminated field sites.