• 제목/요약/키워드: Flow Rate Deviation

Search Result 181, Processing Time 0.031 seconds

A Fundamental Study on the Improvements of Speed Limit at the Ports and Fairways in Korea (항만과 수로의 제한속력 개선방안에 관한 기초 연구)

  • Kim, Deug-Bong;Yun, Byeong-Won;Jeong, Jae-Yong;Park, Jin-Soo;Park, Young-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.5
    • /
    • pp.423-430
    • /
    • 2012
  • The purpose of Speed limit at sea is to keep harbor calmness, to maintain efficient traffic flow and to prevent maritime accidents. The Korean Regional Maritime Affairs and Port Office(KRMAPO) specified and enforced the ship's speed limits at the 19 harbors around the Korean coasts. However, problems have been raised to the adequacy of speed limits. This paper made a research on the speed limit set standards, analyzed vessel traffic survey and the dilemma on the specified speed limits imposed by KRMAPO. The result of this study has shown an overall average of 48 % violation rate on speed limit with passenger ships and large vessels of more than 5,000 tons having higher violation rate. Average speed was higher than the limit speed in some harbors and deviation of 4.2 to 5.2 knots was investigated. Further, harbors having higher average speed also have higher deviation accident incidence. Therefore, this paper had confirmed that there is a need for institutional review and improvement of Korea's port and fairways speed traffic management.

Estimation of Exploitable Groundwater in the Jinju Region by Using a Distributed Hydrologic Model (분포형 수문모형을 이용한 진주지역의 지하수 개발가능량 추정)

  • Lee, Jeong Eun;Chung, Il-Moon;Lee, Jeongwoo;Kim, Min Gyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.655-662
    • /
    • 2021
  • This study aimed to estimate exploitable groundwater for the sustainable supply of groundwater in the Jinju region of South Gyeongsang Province. As an integrated hydrologic analysis model, SWAT-MODFLOW was used to estimate the distributed groundwater recharge in consideration of land use and soil distribution. As a result of calibration of the model, the coefficient of determination between the observed flow and the simulated flow was 0.75-0.80, which was good. The simulated groundwater recharge rate showed a spatio-temporal distribution due to heterogeneous watershed characteristics. The amount of groundwater recharge shows lower values over winter and spring, but it increases according to the pattern of precipitation in summer and autumn. The calculated average annual groundwater recharge was compared with the result using the baseflow separation method of natural flow, and the deviation of both results was small, within 3 %, confirming the validity of the estimated groundwater recharge. Exploitable groundwater is defined as the amount of recharge corresponding to low flow with 10 years of return period. Therefore, in this study, 14.2 % of the annual precipitation was found to be exploitable as a result of calculating the amount of recharge at a 10-year frequency using a statistical frequency analysis technique.

Fertigation Techniques Using Fertilizers with Peristaltic Hose Pump for Hydroponics (연동펌프를 이용한 비료염 공급 관비재배기술 연구)

  • Kim, D.E.;Lee, G.I.;Kim, H.H.;Woo, Y.H.;Lee, W.Y.;Kang, I.C.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2015
  • This study was conducted to develop the fertigation system with a peristaltic hose pump and brushless DC motor. The fertigation system was consisted of sensor, main controller, motor control unit, peristaltic pump, water supply pump, control panel, and filter. The peristaltic pump discharges liquid by squeezing the tube with rollers. Rollers attached to the external circumference of the rotor compresses the flexible tube. The fluid is contained within a flexible tube fitted inside a circular pump casing. The developed fertigation system has no mixing tank but instead injects directly a concentrated nutrient solution into a water supply pipe. The revolution speed of the peristaltic pump is controlled by PWM (Pulse width modulation) method. When the revolution speed of the peristaltic pump was 300rpm, the flow rate of the 3.2, 4.8, 6.3mm diameter tube was 202, 530, 857mL/min, respectively. As increasing revolution speed, the flow rate of the peristaltic pump linearly increased. As the inner diameter of a tube larger, a slope of graph is more steep. Flow rate of three roller was more than that of four roller. Flow rate of a norprene tube with good restoring force was more than that of a pharmed tube. As EC sensor probe was installed in direct piping in comparison with bypass piping showed good performance. After starting the system, it took 16~17 seconds to stabilize EC. The maximum value of EC was 1.44~1.7dS/m at a setting value of 1.4dS/m. The developed fertigation system showed ±0.06dS/m deviation from the setting value of EC. In field test, Cucumber plants generally showed good growth. From these findings, this fertigation system can be appropriately suitable for fertigation culture for crops.

A Study on Inflow Rate According to Shape of Dual Structure Perforated Pipe Applied to Seawater Intake System (해수취수시스템에 적용된 2중구조 유공관의 형태에 따른 취수효율에 대한 연구)

  • Kim, Sooyoung;Lee, Seung Oh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.721-728
    • /
    • 2016
  • 97% of water on earth exists in the form of seawater. Therefore, the use of marine resources is one of the most important research issues at present. The use of seawater is expanding in various fields (seawater desalination, cooling water for nuclear power plants, deep seawater utilization, etc.). Seawater intake systems utilizing sand filters in order to take in clean seawater are being actively employed. For the intake pipe used in this system, assuring equal intake flows through the respective holes is very important to improve the efficiency of the intake and filtering process. In this study, we analyzed the efficiency of the dual structure perforated pipe used in the seawater intake system using 3D numerical simulations and the inflow rate according to the gap of the up holes. In the case of decreasing gaps in the up holes toward the pipe end, the variation of the total inflow rate was small in comparison with the other cases. However, the standard deviation of the inflow rate through the up holes was the lowest in this case. Also, stable flow occurred, which can improve the efficiency of the intake process. In the future, a sensitivity analysis of the various conditions should be performed based on the results of this study, in order to determine the factors influencing the efficiency, which can then be utilized to derive optimal designs suitable for specific environments.

Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device (액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

Study on the Applicability Analysis of HPLC for Fuel Marker (Unimark 1494DB) in Petroleum Products (석유제품의 식별제(Unimark 1494DB) 분석을 위한 HPLC 적용가능성 분석 연구)

  • Hwang, In-ha;Youn, Ju-min;Doe, Jin-woo;Park, Tae-seong;Kang, Hyung-kyu;Ha, Jong-han;Na, Byung-gi
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.1076-1084
    • /
    • 2017
  • For analyzing the qualitative and quantitative analysis of fuel marker in petroleum products, the applicability of HPLC was studied. For the qualitative analysis of fuel marker in kerosene and automotive diesel, optimal analytical conditions(ratio of mobile phase solvent, flow rate, etc) in HPLC were selected and calibration curve for quantitative analysis of fuel marker was prepared based on the result of qualitative analysis. In particular, the correlation coefficient of calibration curve in kerosene and automotive diesel was shown to be 0.999 in a certain concentration range and it could be applied to the quantitative analysis. The results of analysis using the UV/Vis spectrometer, which is the current analysis method of fuel marker, were compared with the analysis results using the HPLC. The kerosene showed a low deviation of about 7 % and the automotive diesel showed a somewhat large deviation of about 20 %.

Surface soil moisture memory using stored precipitation fraction in the Korean peninsula (토양 내 저장 강수율을 활용한 국내 표층 토양수분 메모리 특성에 관한 연구)

  • Kim, Kiyoung;Lee, Seulchan;Lee, Yongjun;Yeon, Minho;Lee, Giha;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.2
    • /
    • pp.111-120
    • /
    • 2022
  • The concept of soil moisture memory was used as a method for quantifying the function of soil to control water flow, which evaluates the average residence time of precipitation. In order to characterize the soil moisture memory, a new measurement index called stored precipitation fraction (Fp(f)) was used by tracking the increments in soil moisture by the precipitation event. In this study, the temporal and spatial distribution of soil moisture memory was evaluated along with the slope and soil characteristics of the surface (0~5 cm) soil by using satellite- and model-based precipitation and soil moisture in the Korean peninsula, from 2019 to 2020. The spatial deviation of the soil moisture memory was large as the stored precipitation fraction in the soil decreased preferentially along the mountain range at the beginning (after 3 hours), and the deviation decreased overall after 24 hours. The stored precipitation fraction in the soil clearly decreased as the slope increased, and the effect of drainage of water in the soil according to the composition ratio of the soil particle size was also shown. In addition, average soil moisture contributed to the increase and decrease of hydraulic conductivity, and the rate of rainfall transfer to the depths affected the stored precipitation fraction. It is expected that the results of this study will greatly contribute in clarifying the relationship between soil moisture memory and surface characteristics (slope, soil characteristics) and understanding spatio-temporal variation of soil moisture.

A Development of Hydrological Model Calibration Technique Considering Seasonality via Regional Sensitivity Analysis (지역적 민감도 분석을 이용하여 계절성을 고려한 수문 모형 보정 기법 개발)

  • Lee, Ye-Rin;Yu, Jae-Ung;Kim, Kyungtak;Kwon, Hyun-Han
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.337-352
    • /
    • 2023
  • In general, Rainfall-Runoff model parameter set is optimized using the entire data to calculate unique parameter set. However, Korea has a large precipitation deviation according to the season, and it is expected to even worsen due to climate change. Therefore, the need for hydrological data considering seasonal characteristics. In this study, we conducted regional sensitivity analysis(RSA) using the conceptual Rainfall-Runoff model, GR4J aimed at the Soyanggang dam basin, and clustered combining the RSA results with hydrometeorological data using Self-Organizing map(SOM). In order to consider the climate characteristics in parameter estimation, the data was divided based on clustering, and a calibration approach of the Rainfall-Runoff model was developed by comparing the objective functions of the Global Optimization method. The performance of calibration was evaluated by statistical techniques. As a result, it was confirmed that the model performance during the Cold period(November~April) with a relatively low flow rate was improved. This is expected to improve the performance and predictability of the hydrological model for areas that have a large precipitation deviation such as Monsoon climate.

HPLC Analysis of Piroxicam in the Rabbit Plasma and its Bioavailability after the Transdermal Administration of Patches (토끼 혈장 중 피록시캄의 HPLC 분석 및 패취제 투여 후 경피흡수)

  • Shin, Dae-Hwan;Park, Seong-Hyeok;Lee, Gyeong-Bok;Lee, Chong-Kil;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.3
    • /
    • pp.177-183
    • /
    • 2009
  • A rapid and sensitive reversed-phase high performance liquid chromatography (HPLC) method was developed for the determination of piroxicam in the rabbit plasma. After a treatment of plasma sample by liquid-liquid extraction, the drug was analyzed on an HPLC system with ultraviolet detection at 330 nm. HPLC was carried out using reversed-phase isocratic elution with a C18 column, a mobile phase of a mixture of acetonitril, doubly deionized water and acetic acid 43.74:56.00:0.26 v/v%) at a flow rate of 1.1 mL/min. The chromatograms showed good resolution and sensitivity and no interference of plasma. The calibration curve for the drug in plasma sample was linear over the concentration range of 0.01-2.0 ${\mu}$g/mL. The intra- and inter-day assay accuracies of this method ranged from 86.82% to 108.33% of normal values and the precision did not exceed 13% of relative standard deviation. The plasma concentration of piroxicam decreased to below the quantifiable limit at 12 hr after the i.v. bolus administration to rabbits following dose of 0.375 mg/kg yielding a apparen t plasma half life of 1.38 hr. The transdermal route prolongs plasma levels of piroxicam. The bioavailability, calculated from the dose-adjusted ratio of the $AUC_{transdermal}$ to the $AUC_{i.v.}$, was 7.44%. The plasma concentration of piroxicam was detected by 48 hr after the transdermal administration of patch at a dose of 32 mg/kg. This method was suitable for cutaneous absorption studies of piroxicam in the rabbit after transdermal administration of different types of dosages of the drug.

A Study on the Characteristic of Emission for Air Pollutant by Small Two-stroke Engines (2행정 소형엔진의 대기오염물질 배출특성에 관한 연구)

  • Kim, Pil-Su;Choi, Sang-Jin;Park, Geon-Jin;Han, Yong-Hee;Kim, Dai-Gon;Yeo, So-Young;Kim, Jeong;Goh, Ji-Won;Jang, Young-Kee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.6
    • /
    • pp.613-623
    • /
    • 2016
  • In this study, pilot experiments were conducted by setting operation conditions to analyze characteristics of emission for air pollutant from small two-stroke engines. Emission factors of the measured concentration of pollutant were compared with EEA. Emission factor of CO analyzed by experiments - concentration, flow rate, fuel consumption, etc.- was estimated at 816,011 g-CO/ton-fuel in average. It was confirmed that more than 80% of the fuel consumption is discharged to the Carbon Monoxide, and that as the engine load becomes higher, emission factor of CO increases in the form of log function. The average emission factor of $NO_x$ and $PM_{10}$ was $3,801g-NO_x/ton-fuel$ and $3,730g-PM_{10}/ton-fue$l each. The deviation was not large by comparing the fuel-based emission factor of EEA and the result of this study. Since considerable pollutants are expected to be discharged from the small two-stroke engines, continuous research and support of the policy is required.