• Title/Summary/Keyword: Flow Prediction

Search Result 2,408, Processing Time 0.028 seconds

Numerical Simulation on the Behavior of Air Cloud Discharging into a Water Pool (수조로 방출되는 기포 거동에 대한 수치해석)

  • 김환열;김영인;배윤영;송진호;김희동
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.237-246
    • /
    • 2002
  • If the safety depressurization system of APR-1400, the Korean next generation reactor, is in operation, water, air and steam are successively discharging into a in-containment refueling water storage tank through spargers. Among the phenomena occurring during the discharging processes, the air bubble clouds produce a low-frequency and high-amplitude oscillatory loading, which may result in the most significant damages to the submerged structures if the oscillation frequency is the same or close to the natural frequency of the structures. The involved phenomena are so complicated that most of the prediction of frequency and pressure loads has been resorted to experimental work and computational approach has been precluded. This study deals with a numerical simulation on the behavior of air bubble clouds discharging into a water pool through a sparger, by using a commercial thermal hydraulic analysis code, FLUENT, version 4.5. Among the multiphase flow models, the VOF (Volume Of Fluid) model was selected to simulate the water, air and steam flows. A satisfactory result was obtained comparing the analysis results with the ABB-Atom test results which had been performed for the development of sparser.

The Development and Application of the Quasi-dynamic Wetness Index and the Dynamic Wetness Index (유사 동력학적 습윤지수와 동력학적 습윤지수의 개발과 적용)

  • Han, Ji-Young;Kim, Sang-Hyun;Kim, Nam-Won;Kim, Hyun-Jun
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.6
    • /
    • pp.961-969
    • /
    • 2003
  • Formulation of quasi-dynamic wetness index was derived to predict the spatial and temporal distribution of the soil moisture. The algorithm of dynamic wetness index was developed through introducing the convolution integral with the rainfall input. The spatial and temporal behaviors of the wetness index of the Sulmachun Watershed was calculated using the digital elevation model(DEM) and the rainfall data for two years. The spatial distribution of the dynamic wetness index shows most dispersive feature of flow generation among the three assumptions of steady, quasi-dynamic and dynamic. The statistical distribution of the quasi-dynamic wetness index and the dynamic wetness index approximate to the steady state wetness index as the time step is increased. The dynamic wetness index shows mixed distribution of the normalized probability density function.

Prediction of Microstructure During High Temperature Forming of Ti-6Al-4V Alloy (Ti-6Al-4V 합금의 고온 성형시 미세조직 예측에 관한 연구)

  • Lee You Hwan;Shin Tae Jin;Park No Kwang;Shim In Ok;Hwang Sang Moo;Lee Chong Soo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.4 s.19
    • /
    • pp.70-78
    • /
    • 2004
  • A study has been made to investigate the high temperature deformation behavior of Ti-6Al-4V alloyand to predict the final microstructure under given forming conditions. Equiaxed and $Widmanst\ddot{a}tten$ microstructures of Ti-6Al-4V alloys were prepared as initial microstructures. By performing the compression tests at high temperatures$(700\~1100^{\circ}C)$ and at a wide range of strain rates$(10^{-4}\~10^2/s)$, various parameters such as strain rate sensitivity(m) and activation energy(Q) were calculated and used to establish constitutive equations. When the specimens were deformed up to strain 0.6, equiaxed microstructure did not show any significant changes in microstructure, while $Widmanst\ddot{a}tten$ microstructure revealed considerable flow softening, which was attributed to the globularization of a platelet at the temperature range of $800\~970^{\circ}C$ and at the strain rate range of $10^{-4}\~10^{-2}/s$. To predict the final microstructure after forming, finite element analysis was performed considering the microstructural evolution during the deformation. The grain size and the volume fraction of second phase of deformed body were predicted and compared with the experimental results.

3-Dimensional Finite Element Analysis for Collecting Structure of Combustible Metal Dust During Explosion (가연성 금속분진 폭발시 저장 및 포집용 구조물에 대한 3차원 유한요소 해석)

  • Jang, Chang-Bong;Yong, Jong-Won;Baek, Jong-Bae;Kwon, Hyuck-Myun;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.5
    • /
    • pp.19-24
    • /
    • 2011
  • Due to the latest industrial flow comes mainly switch to high-tech industries, combustible metals as Al, Mg, Li, Zn more require to use for the aircraft, car, cell phones, electronics and others. As a result, Increasing the processing of combustible metals due to increase in amount of combustible metals giving rise dust explosions also. Most Explosions caused by combustible metal dust, occurred in air cleaning device of local exhaust ventilation to capture and store the combustible dust. Therefore, this study was conducted to present and analyze technically that deformation and rupture shape of air cleaning device structure by Finite Element Analysis(FEA) rather than a simple prediction, in case of explosion occurs in an air cleaning device.

Effect of Sea Surface Temperature Gradient Induced by the Previous Typhoon's Cold Wake on the Track of the Following Typhoon: Bolaven (1215) and Tembin (1214) (선행 태풍의 해수 냉각에 의한 해수면 온도 경도가 후행 태풍의 진로에 미치는 영향: 볼라벤(1215)과 덴빈(1214))

  • Moon, Mincheol;Choi, Yumi;Ha, Kyung-Ja
    • Atmosphere
    • /
    • v.26 no.4
    • /
    • pp.635-647
    • /
    • 2016
  • The effects of sea surface temperature (SST) gradient induced by the previous typhoon on the following typhoon motion over East Asia have been investigated using Weather Research and Forecasting (WRF) model for the previous Typhoon Bolaven (1215) and following Typhoon Tembin (1214). It was observed that Typhoon Bolaven remarkably reduced SST by about $7^{\circ}C$ at Yellow Sea buoy (YSbuoy). Using the WRF experiments for the imposed cold wake over West of Tembin (WT) and over East of Tembin (ET), this study demonstrates that the effects of eastward SST gradient including cold wake over WT is much significant rather than that over ET in relation to unexpected Tembin's eastward deflection. This difference between two experiments is attributed to the fact that cold wake over WT increases the magnitude of SST gradient under the eastward SST gradient around East Asia and the resultant asymmetric flow deflects Typhoon Tembin eastward, which is mainly due to the different atmospheric response to the SST forcing between ET and WT. Therefore, it implies that the enhanced eastward SST gradient over East Asia results in larger typhoon deflection toward the region of warmer SST according to the location of the cold wake effect. This result can contribute to the improvement of track prediction for typhoons influencing the Korean Peninsula

A Study of Smoke Movement in a Short Tunnel (짧은 터널 내의 연기거동에 관한 연구)

  • Kim, Sung-Chan;Ryou, Hong-Sun;Kim, Chung-Ik;Hong, Ki-Bae
    • Tunnel and Underground Space
    • /
    • v.12 no.1
    • /
    • pp.31-36
    • /
    • 2002
  • This paper concerns smoke propagation in tunnel fires with various size of fire source. Experiments carried out in model tunnel and those results were compared with numerical results. The Froude scaling law was used to scale model tests for comparison with larger scale tests. In order to validate for numerical analysis, temperature distribution of predicted data was compared with measured data. Examining the temperature distribution, we found that smoke layer does not come down under 50% of tunnel heights for a short tunnel heights for a short tunnel firs without ventilation. Front velocity of smoke layer is proportional to the cube root of heat release rate. And it is in good agreement with existing empirical expression and numerical prediction. In a short tunnel fire, horizontal propagation of smoke layer is more important than vertical smoke movement for evacuation plan.

PERFORMANCE ASSESSMENT OF THE RANS TURBULENCE MODELS IN PREDICTION OF AERODYNAMIC NOISE FOR AIR-CONDITIONER INDOOR UNIT (에어컨 실내기의 공력소음 예측을 위한 RANS 난류모델의 성능 평가)

  • Min, Y.H.;Kang, S.;Hur, N.;Lee, C.;Park, J.
    • Journal of computational fluids engineering
    • /
    • v.17 no.4
    • /
    • pp.81-86
    • /
    • 2012
  • The objective of the present study is to investigate the effects of various turbulence models on the aerodynamic noise of an air-conditioner (AC) indoor unit. The results from URANS (unsteady Reynolds-averaged Navier-Stokes) simulations with the standard k-$\varepsilon$, k-$\omega$ shear stress transport (SST) and Spalart-Allmaras (S-A) turbulence models were analyzed and compared with the noise data from the experiments. The frequency spectra of the far-field acoustic pressure were computed using the Farrasat equation derived from the Ffowcs Williams-Hawkings (FW-H) equation based on the acoustic analogy model. Two fixed fan casings and the rotating cross-flow fan were used as the source surfaces of the dipole noise in the Farrasat equation. The result with the standard k-$\epsilon$ model showed a much better agreement with the experimental data compared to the k-w SST and S-A models. The differences in the pressure spectra from the different turbulence models were discussed based on the instantaneous vorticity fields. It was found that the over-estimated power spectra with the k-w SST and S-A models are related to the emphasized small-scale vortices produced with these models.

Prediction methods for two-phase flow frictional pressure drop of FC-72 in parallel micro-channels (병렬 마이크로 채널에서 FC-72의 2상 유동 마찰 압력 강하 예측)

  • Choi, Yong-Seok;Lim, Tae-Woo;You, Sam-Sang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.821-827
    • /
    • 2014
  • In this study, an experimental study was performed to predict the two-phase frictional pressure drop of FC-72 in parallel micro-channels. The parallel micro-channels consist of 15 channels with depth 0.2 mm, width 0.45 mm and length 60 mm. And tests were performed in the ranges of mass fluxes from 152.2 to $584.2kg/m^2s$ and heat fluxes from 7.5 to $28.3kW/m^2$. The experimental data was compared and analyzed with existing correlations to predict the pressure drop. The existing methods to predict the pressure drop used the homogeneous model and the separated model. In this study, the new correlation was proposed by modified existing correlation using the separated model, and the new correlation predicted consequently with the experimental data within MAE of 9.6%.

Optimal Design of Rotor Profile of Internal Gear Pump for Noise Reduction (내접형 기어펌프용 로터의 소음저감을 위한 치형 최적설계)

  • Bae, Jun Ho;Bae, Won Byong;Joo, Ung Tak;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.3
    • /
    • pp.295-302
    • /
    • 2014
  • An internal gear pump is required to improve the flow rate and noise. Furthermore, such pumps are durable and small in size. In this study, equations of the rotor shape with multiple profiles (ellipse 1-involute-ellipse 2) were derived, and relevant performance parameters (pressure angle, irregularity, and specific sliding) of the internal gear pump to noise were predicted and compared. Rotor profiles and performance parameters were obtained by a prediction algorithm for theoretical analysis, and the effects between the design parameters and the performance parameters were analyzed. Based on the analysis results of the effects, an optimal design of the rotor profile was proposed, and a noise test of the prototype was performed to evaluate the reliability of the design.

Impact of Climate Change on the Groundwater Recharge and Groundwater Level Variations in Pyoseon Watershed of Jeju Island, Korea (기후 변화에 따른 제주도 표선 유역의 함양률 및 수위변화 예측)

  • Shin, Esther;Koh, Eun-Hee;Ha, Kyoochul;Lee, Eunhee;Lee, Kang-Kun
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.6
    • /
    • pp.22-35
    • /
    • 2016
  • Global climate change could have an impact on hydrological process of a watershed and result in problems with future water supply by influencing the recharge process into the aquifer. This study aims to assess the change of groundwater recharge rate by climate change and to predict the sustainability of groundwater resource in Pyoseon watershed, Jeju Island. For the prediction, the groundwater recharge rate of the study area was estimated based on two future climate scenarios (RCP 4.5, RCP 8.5) by using the Soil Water Balance (SWB) computer code. The calculated groundwater recharge rate was used for groundwater flow simulation and the change of groundwater level according to the climate change was predicted using a numerical simulation program (FEFLOW 6.1). The average recharge rate from 2020 to 2100 was predicted to decrease by 10~12% compared to the current situation (1990~2015) while the evapotranspiration and the direct runoff rate would increase at both climate scenarios. The decrease in groundwater recharge rate due to the climate change results in the decline of groundwater level. In some monitoring wells, the predicted mean groundwater level at the year of the lowest water level was estimated to be lower by 60~70 m than the current situation. The model also predicted that temporal fluctuation of groundwater recharge, runoff and evapotranspiration would become more severe as a result of climate change, making the sustainable management of water resource more challenging in the future. Our study results demonstrate that the future availability of water resources highly depends on climate change. Thus, intensive studies on climate changes and water resources should be performed based on the sufficient data, advanced climate change scenarios, and improved modeling methodology.