• 제목/요약/키워드: Flow Efficiency

검색결과 4,870건 처리시간 0.035초

2차원 비정상 유동 해석 효율 향상을 위한 Wavelet 기법 응용 연구 (RESEARCH ON THE WAVELET METHOD FOR THE IMPROVEMENT OF COMPUTATIONAL EFFICIENCY OF TWO DIMENSIONAL FLOW PROBLEMS)

  • 강형민;홍상원;정지훈;김규홍;이도형;이동호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년 추계학술대회논문집
    • /
    • pp.42-49
    • /
    • 2008
  • A wavelet method is presented in order to improve the computational efficiency of two dimensional unsteady flow problems while maintaining the order of accuracy of conventional CFD schemes. First, by using the interpolating wavelet transformation including decomposition and thresholding, an adaptive dataset to a solution is constructed. Then, inviscid and viscous fluxes are calculated only at the points within an adaptive dataset, which enhances the computational efficiency. Second, thresholding step is modified to maintain the spatial and temporal accuracy of conventional CFD schemes automatically by selecting the threshold value between user-defined value and the magnitude of spatial or temporal truncation error. The wavelet method suggested in this study is successfully applied to various unsteady flow problems and it is shown that the computational efficiency is enhanced with maintaining the computational accuracy of CFD schemes.

  • PDF

유동해석을 이용한 고압증기터빈 단효율 변화 예측 (Rediction of Stage Efficiency Variation of a USC High Pressure Steam Turbine by Computational Fluid Dynamics)

  • 강수영;장혁준;이정진;김동섭;박성진;홍기원
    • 한국유체기계학회 논문집
    • /
    • 제20권2호
    • /
    • pp.17-25
    • /
    • 2017
  • Prediction of performance and operating characteristics of a state-of-the-art ultra-supercritical (USC) steam turbine is an important issue in many ways. Theoretical and empirical correlation equations, developed a few decades ago, have been widely used in commercial programs for a prediction of performance. To improve of these correlation equations and apply them to the high pressure turbine of a USC steam turbine, computational fluid dynamic analysis was carried out and correlation equations to calculate efficiency variation of each stage were made. Both fluid dynamic characteristic and thermodynamic performance was analyzed for the development of the correlation equations. In particular, the impact of flow addition through an overload valve (OLV) between stages was examined throughly. The trend of pressure drop due to the flow mixing by the OLV flow addition was analyzed and an efficiency correlation equation considering the OLV flow was also made.

가스보일러 코일형 열교환기의 열전달 특성에 관한 실험적 연구 (The Experimental Study on the Heat Transfer Characteristics)

  • 홍성혁;김영기;김일겸;김동춘;이창언;임장순
    • 태양에너지
    • /
    • 제17권4호
    • /
    • pp.57-66
    • /
    • 1997
  • The performance of gas-fired boilers were experimentally investigated. The heat exchanger used for the experiments consisted of circular tube with longitudinal fins for the gas side and a spiral coil for the water side. The burner was located at the top of the heat exchanger, and the burned gas flowed down to the exit. The experiments carried out for different water flow rates, the heat capacities of the boiler and the number of baffle. The thermal efficiency of the upward flow was higher than that of the downward flow of the water in the heat exchanger. As the boiler capacity increased, the thermal efficiency decreased. As the number of the baffles increase, the thermal efficiency increased and the increasing rate of the efficiency decreased. The gas-side overall heat transfer coefficient was independent of the flow rate of the water. The effect of the number of the baffles on the heat transfer coefficient was greater than that of the boiler capacity.

  • PDF

DPF의 PM 포집효율 예측을 위한 다양한 다공성 매질 유동장 모델 해석 (A Detailed Examination of Various Porous Media Flow Models for Collection Efficiency and Pressure Drop of Diesel Particulate Filter)

  • 정승채;윤웅섭
    • 한국자동차공학회논문집
    • /
    • 제15권1호
    • /
    • pp.78-88
    • /
    • 2007
  • In the present study a detailed examination of various porous media models for predicting filtration efficiency and pressure drop of diesel particulate filter (DPF), such as sphere-in-cell and constricted tube models, are attempted. In order for demonstrating their validities of correct estimation on permeability, geometry of property configurations common in commercial cordierite DPFs are correlated to the porous media flow models, and validations of predicted filtration efficiencies due to the use of different unit collectors are made with experiments. The result shows that the porosity, pore size and permeability of cordierite DPF can be successfully correlated by Kuwabara flow field with correction factor of 0.6. The unit collector efficiency predicted by sphere-in-cell model agrees very well with measurements in accumulation mode, whereas that by constricted tube model with significant prediction error.

기액 이상류시의 원심펌프특성에 관한 실험적 연구 (An Experimental Study on the Centrifugal Pump Characteristics in Air-Water Two-Phase Flow)

  • 김성윤;이상일;김유택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권6호
    • /
    • pp.685-692
    • /
    • 2006
  • In a general centrifugal pump, if it is operated in a two-phase flow the activity of the impeller usually degrades and occasionally losses its function. However, the effect of break down of centrifugal pump due to entrained air has not been clarified yet. This paper shows the air-water two-phase flow characteristics of closed type and semi-open type impellers. In a sing1e-phase flow, closed-type impeller has higher efficiency and head. But in air-water two-phase flow semi-open type impeller's rates of decreases of efficiency and head are decreased.

레인지 후드용 시로코 홴 성능 특성에 관한 연구 (A Study on the Performance Characteristics of the Sirocco Fan in a Range Hood)

  • 박상태;최영석;박문수;김철호;권오명
    • 한국유체기계학회 논문집
    • /
    • 제8권2호
    • /
    • pp.9-15
    • /
    • 2005
  • This paper presents an experimental and numerical study on the overall performance and local flow characteristics of sirocco fan in a range hood. Measurement of overall performance for sirocco fans were conducted based on AMCA standard 210. The effects of flow blockages due to the motor inside the fan on the fan performance were investigated by experimentally and numerically and the results were compared with each other. The numerical and experimental results show the inlet flow blockage reduces the performance (ie. fan static pressure, design flow rate, maximum efficiency and free delivery flow rate) of fan. It is found that the blockage makes the flow field highly non-uniform through the blade and cause the efficiency decrement.

비소음 측정을 이용한 저소음 축류홴 설계 (Design of Low Noise Axial Flow Fan Using Specific Sound Presssure Level)

  • 김창준;이동익
    • 소음진동
    • /
    • 제10권5호
    • /
    • pp.873-879
    • /
    • 2000
  • Experimental investigation was conducted to study the effects of pitch angle maximum camber on the performance and noise of an axial-flow fan used in outdoor-unit of air -conditioner. For this study the axial-flow fan whose pitch angle can be varied was made and the Specific sound Pressure Level and other coefficients were measured using the anechoic fan tester. It is found that pitch angle affects more severly than the maximum camber on the fan performance. On the while the maximum camber affects much on the specific sound power level. Present results show that it is important to choose the optimum pitch angle and maximum camber to design the high-performance and low-noise axial-flow fan and specific noise measured in the anechoic fan tester can be sued effectively for the design of low-noise fan.

  • PDF

1단 전기집진기에서 난류확산과 2차유동이 입자의 농도분포에 미치는 영향 (Effects of Turbulence Diffusion and Secondary Flows on the Particle Concentration Distribution in Single Stage ESP)

  • 정상현;김상수;김용진
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2271-2282
    • /
    • 1995
  • Numerical simulations for the effects of secondary flow and turbulence diffusion on the particle concentration distributions have been carried out for the single stage electrostatic precipitator. The electrohydrodynamic secondary flow, particle concentration distribution and collection efficiency have been evaluated as a function of dimensionless parameters such as Re, $N_{end}$, $P_{e}$ x. The results of simulations show that for increasing secondary flow intensity the concentration distribution is drastically deformed and collection efficiency is decreased which is more than due to turbulent diffusion.n.n.

엔진 냉각 시스템 개선에 관한 실험적 연구 (An Experimental Study on Engine Cooling System Improvement)

  • 전문수;황용하
    • 한국분무공학회지
    • /
    • 제9권4호
    • /
    • pp.77-82
    • /
    • 2004
  • This paper describes the improvement of engine cooling system. To improve engine cooling performance, the authors approached in two ways. One is to increase water pump performance, changing of impeller shape and lightening of material were carried out. The second one is cooling efficiency rise, which were investigated with head gasket coolant flow passage optimization with flow visualization technique. The test results show that water pump performance was increased effectively, reduction of pump drive torque, and increase of pump flow-rate and pressure rise. Gasket hole pattern optimization test results represent an optimized head coolant flow which stands cross flow from exhaust to intake port side and small vortex were removed.

  • PDF

맥동 유동이 있는 트윈 스크롤 터보과급기의 터빈 효율 측정 (Turbine Efficiency Measurement of Pulsating Flow in a Twin Scroll Turbocharger)

  • 정진은;전세훈
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.386-391
    • /
    • 2021
  • 터터보 과급은 디젤엔진과 가솔린엔진 모두에서 핵심기술이다. 특히 가솔린엔진에서 엔진 다운사이징 등 다른 제어 기술과 결합하여 이산화탄소(CO2) 배출을 감소시키는 데 효과적이다. 본 연구에서는 승용차용 가솔린엔진에 장착되는 트윈 스크롤 터빈 터보과급기에서 맥동유동의 터빈 효율을 측정하였다. 맥동 생성장치가 있는 저온 테스트 벤치를 제작하여 맥동 유동이 있는 비정상상태의 압력과 온도를 측정하고 터빈 효율을 산출하였다. 테스트 벤치는 공기 압축기, 트윈 스크롤 터빈, 온도 및 압력 측정 장치 등으로 구성되었다. 실제 승용차용 엔진에서 주로 사용되는 중저속 엔진 작동 영역에 해당하는 맥동 주파수 25.0 Hz와 33.3 Hz를 공급하면서 터보과급기 회전속도를 60,000 rpm에서 100,000 rpm까지 변화시키며 측정을 수행하였다. 이때 압축비를 1.088에서 1.600 사이의 값으로 조정하였다. 이 측정 조건에서 터빈 효율은 0.517~0.544 값을 보였다. 맥동 주파수 33.3 Hz의 경우, 터빈 회전수 60,000 rpm에서 터빈 효율의 변동은 7.7%이나 터빈 회전수 100,000 rpm에서 변동은 2.6%로 터빈 회전수가 증가함에 따라 맥동의 영향은 감소하였다. 맥동 유동에서의 터빈 효율은 정상 유동 터빈 효율에 비해 터빈 회전수 60,000 rpm 인 경우 7.0%, 회전수 100,000 rpm 인 경우 3.0% 낮은 값을 보이고 있어 맥동 유동이 터빈 효율을 악화시키는 결과를 보였으며 이러한 영향은 터빈 회전수가 증가함에 따라 감소하였다.