• Title/Summary/Keyword: Flow Correlation

Search Result 2,018, Processing Time 0.024 seconds

Measure Correlation Analysis of Network Flow Based On Symmetric Uncertainty

  • Dong, Shi;Ding, Wei;Chen, Liang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.6
    • /
    • pp.1649-1667
    • /
    • 2012
  • In order to improve the accuracy and universality of the flow metric correlation analysis, this paper firstly analyzes the characteristics of Internet flow metrics as random variables, points out the disadvantages of Pearson Correlation Coefficient which is used to measure the correlation between two flow metrics by current researches. Then a method based on Symmetrical Uncertainty is proposed to measure the correlation between two flow metrics, and is extended to measure the correlation among multi-variables. Meanwhile, the simulation and polynomial fitting method are used to reveal the threshold value between different correlation degrees for SU method. The statistical analysis results on the common flow metrics using several traces show that Symmetrical Uncertainty can not only represent the correct aspects of Pearson Correlation Coefficient, but also make up for its shortcomings, thus achieve the purpose of measuring flow metric correlation quantitatively and accurately. On the other hand, reveal the actual relationship among fourteen common flow metrics.

A PROPOSED CORRELATION FOR CRITICAL FLOW RATE OF WATER FLOW

  • KIM, YEON-SIK
    • Nuclear Engineering and Technology
    • /
    • v.47 no.1
    • /
    • pp.135-138
    • /
    • 2015
  • A new correlation predicting the idealized critical mass-flow rates of water for subcooled and saturated liquid water including two-phase water flow was developed for a wide range of upstream stagnation pressures (e.g., 0.5-20.0 MPa). A choking correction factor dependent on the upstream stagnation pressure and subcooled temperature was introduced into a new correlation, and its values were suggested to satisfy the idealized nozzle data within 10% error ranges. The suggested correlation will be instructive and helpful for related studies and/or engineering works.

Comparison of Correlation Coefficients and Intraclass Correlation Coefficients Between Two-way FSI Flow Velocity of Simulated Abdominal Aorta and Human 4D Flow MRI Flow Velocity (시뮬레이션 복부 대동맥의 양방향 FSI 유속과 인체 4D flow MRI 유속의 상관계수, 급내상관계수 비교)

  • Ahn, Hae Nam;Kim, Jung Hun;Park, Ji eun;Choi, Hyeun Woo;Lee, Jong Min
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.143-149
    • /
    • 2021
  • In order to predict and prevent the disease of the abdominal aorta, which is the largest artery in the human body and the most common aneurysm, the normal arterial blood flow operation should be considered. To this end, we are trying to solve problems that may arise in the future by executing FSI based on the data obtained from 4D flow MRI. However, to match the similarity between the 4D flow MRI flow and the FSI flow, correlation was used in previous papers, but the correlation did not show the degree of agreement. Therefore, in this paper, we analyzed the correlation between the 4D flow MRI flow velocity of the human abdominal aorta and the two-way FSI flow velocity in which the three physical properties used for the aortic FSI were added to the CT abdominal aorta 3D model and the interclass correlation coefficient. As a result, the physical property M2 showed the highest similarity in correlation and intraclass correlation coefficient, and this property is intended to be helpful in the future study of the abdominal aortic two-way FSI flow rate.

Condensation Heat Transfer Correlation for Smooth Tubes in Annular Flow Regime

  • Han Dong-Hyouck;Moon C.;Park C.;Lee Kyu-Jung
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.8
    • /
    • pp.1275-1283
    • /
    • 2006
  • Condensation heat transfer coefficients in a 7.92 mm inside diameter copper smooth tube were obtained experimentally for R22, R134a, and R410A. Working conditions were in the range of $30-40^{\circ}C$ condensation temperature, $95-410 kg/m^2s$ mass flux, and 0.15-0.85 vapor quality. The experimental data were compared with the eight existing correlations for an annular flow regime. Based on the heat-momentum analogy, a condensation heat transfer coefficients correlation for the annular flow regime was developed. The Breber et al. flow regime map was used to discern flow pattern and the Muller-Steinhagen & Heck pressure drop correlation was used for the term of the proposed correlation. The proposed correlation provided the best predicted performance compared to the eight existing correlations and its root mean square deviation was less than 8.7%.

A Convective Heat Transfer Correlation for Turbulent Gas-Liquid Two-Phase Flow in Vertical Pipes

  • Kim, Dong-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.4
    • /
    • pp.27-36
    • /
    • 2001
  • A new two-phase non-boiling convective heat transfer correlation for turbulent flow $(Re_{SL}>4000)$ in vertical tubes with different fluid flow patterns and fluid combinations was developed using experimental data available from the literature. The correlation presented herein originates from a careful analysis of the major non-dimensional parameters affecting two-phase heat transfer. This model takes into account the appropriate contributions of both the liquid and gas phases using the respective cross-sectional areas occupied by the two phases. A total of 255 data points from three available studies (which included the four sets of data) were used to determine the curve-fitted constants in the improved correlation. The performance of the new correlation was compared with two-phase correlations from the literature, which were developed for specific fluid combinations.

  • PDF

A Study of Performance Improvement of Internet Application Traffic Identification using Flow Correlation (플로우 상관관계를 통한 인터넷 응용 트래픽 분석의 성능 향상에 관한 연구)

  • Yoon, Sung-Ho;Kim, Myung-Sup
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.6B
    • /
    • pp.600-607
    • /
    • 2011
  • As network traffic is dramatically increasing due to the popularization of Internet, the need for application traffic identification becomes important for the effective use of network resources. In this paper, we present an Internet application traffic identification method based on flow correlation to overcome limitation of signature-based identification methods and to improve performance (completeness) of it. The proposed method can identify unidentified flows from signature-based method using flow correlation between identified and unidentified flows. We propose four separate correlation methods such as Server-Client, Time, Host-Host, and Statistic correlation and describe a flow correlation-based identification system architecture which incorporates the four separate methods. Also we prove the feasibility and applicability of our proposed method by an acceptable experimental result.

An Empirical Correlation of Refrigerant Flow Rate Through Coiled Capillary Tubes (코일 형상을 고려한 모세관 냉매유량 예측 상관식)

  • Park, Cha-Sik;Jang, Yong-Hee;Lee, Young-Soo;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.1 s.256
    • /
    • pp.91-98
    • /
    • 2007
  • Air-conditioners use a spirally coiled capillary tube as an expansion device to enhance compactness of the unit. However, most empirical correlations in open literature were developed for straight capillary tubes without considering coiled effects on the mass flow rate. The objectives of this study are to investigate the flow characteristics of coiled capillary tubes and to develop a generalized correlation for mass flow rate through coiled capillary tubes. The mass flow rates through the coiled capillary tubes and straight capillary tubes were measured by varying operating conditions and tube geometry. The condensing temperatures varied at 40.5, 47.5 and $54.5^{\circ}C$, and subcoolings altered at 3.5, 6.5 and $11.5^{\circ}C$. The mass flow rates of the coiled capillary tubes decreased by 5 to 16% compared with those of the straight capillary tubes at the same operating conditions. An empirical correlation was developed by introducing equivalent length of capillary tube with non-dimensional parameters for coiled shape. The present correlation predicts the data with average and standard deviations of 0.33% and 3.24%, respectively.

A Study on Flow Characteristics of a Ginseng Cleaner Using PIV (PIV에 의한 인삼세척기의 특성연구)

  • 송치성
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.140-145
    • /
    • 2000
  • The objective of experimental study is to apply simultaneous measurement by PIV(Particle Image Velocimetry) to high_speed flow characteristics within ginseng cleaner model. Three different kinds of flow rate(15.20 27ℓ/min) are selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. The instantaneous velocity distribution time0mean velocity distribution and velocity profile are represented quantitatively for the deeper understanding of the flow characteristics in a ginseng cleaner model.

  • PDF

The Relationship Between Job Stress and Teaching Flow of Early Childhood Teachers : The Mediating Effect of Early Childhood Teachers' Resilience (유아교사의 직무스트레스와 교수몰입의 관계 : 내적·외적 회복탄력성의 매개효과)

  • Kim, Sung Hee;Ahn, Hyo Jin
    • Journal of Families and Better Life
    • /
    • v.34 no.4
    • /
    • pp.37-49
    • /
    • 2016
  • The purpose of this study was to examine the mediating effect of inner resilience and external resilience on the relationship between the job stress of early childhood education teachers and their teaching flow. Data were collected through questionnaires from 221 early childhood Korean teachers in the InCheon area. The instruments used in this study were the Kindergarten Teachers' Job Stress Scale, Early Childhood Teachers' Resilience Scale, and Teaching Flow Scale. The data were analyzed by Pearson's correlation analysis, multiple regression analysis, and Baron and Kenny's method. It was adapted to SPSS ver. 18.0 for Windows. This study followed a mediated effect model. First, there was a negative correlation between the job stress and teaching flow. There was a positive correlation between the teaching flow and the resilience. Secondly, there was a negative correlation with job stress and teaching flow in path model 1. In path model 2, there was a positive correlation with resilience and teaching flow. Teaching flow was statistically and significantly influenced by resilience. Thirdly, there was the mediating effect of inner resilience and external resilience on the relationship between the job stress of early childhood education teachers and their teaching flow. These results can be used as the basic data for the improvement of early childhood education teachers' teaching flow in the future.

Correlation of Convective Boiling Heat Transfer in a Horizontal Tube for Pure Refrigerants and Refrigerant Mixtures (순수 및 혼합냉매의 유동증발 열전달 상관식)

  • Shin, J.Y.;Kim, M.S.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.254-266
    • /
    • 1996
  • Boiling heat transfer coefficients of pure refrigerants(R22, R32, R125, R134a, R290, and R600a) and refrigerant mixtures(R32/R134a and R290/R600a) are measured experimentally and compared with several correlations. Convective boiling term of Chen's correlation predicts experimental data for pure refrigerants fairly well(root-mean-square error of 12.1% for the quality range over 0.2). An analysis of convective boiling heat transfer of refrigerant mixtures is performed for an annular flow to study degradation of heat transfer. Annular flow is the subject of this analysis because a great portion of the evaporator in refrigeration or air conditioning system is known to be in the annular flow regime. Mass transfer effect due to composition difference between liquid and vapor phases, which is considered as a driving force for mass transfer at interface, is included in this analysis. Correction factor $C_F$ is introduced to the correlation for the pure substances through annular flow analysis to apply the correlation to the mixtures. The flow boiling heat transfer coefficients are calculated using the correlation considering nucleate boilling effect in the low quality region and mass transfer effect for nonzazeotropic refrigerant mixtures.

  • PDF