• Title/Summary/Keyword: Floor spectrum

Search Result 118, Processing Time 0.029 seconds

Seismic Rehabilitation of Nonductile Reidorced Concrete Gravity Frame (비연성 철근 콘크리트 중력 프레임에 의한 지진 보강)

  • Dong Choon Choi;Javeed A. Munsh;Kwang W. Kim
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.5
    • /
    • pp.116-123
    • /
    • 2001
  • This paper represents results of an effort to seismically rehabilitate a 12-story nonductile reinforced concrete frame building. The frame located in the most severe seismic area, zone 4, is assumed to be designed and detailed for gravity load requirements only. Both pushover and nonlinear time-history analyses are carried out to determine strength, deformation capacity and the vulnerability of the building. The analysis indicates a drift concentration at the $1^{st}$ floor level due to inadequate strength and ductility capacity of the ground floor columns. The capacity curve of the structure, when superimposed on the average demand response spectrum for the ensemble of scaled earthquakes indicates that the structure is extremely weak and requires a major retrofit. The retrofit of the building is attempted using viscoelastic (VE) dampers. The dampers at each floor level are sized in order to reduce the elastic story drift ratios to within 1%. It is found that this requires substantially large dampers that are not practically feasible. With practical size dampers, the analyses of the viscoelastically damped building indicates that the damper sizes provided are not sufficient enough to remove the biased response and drift concentration of the building. The results indicate that VE-dampers alone are not sufficient to rehabilitate such a concrete frame. Concrete buildings, in general, being stiffer require larger dampers. The second rehabilitation strategy uses concrete shearwalls. Shearwalls increased stiffness and strength of the building, which resulted in reducing the drift significantly. The effectiveness of VE-dampers in conjunction with stiff shearwalls was also studied. Considering the economy and effectiveness, it is concluded that shearwalls were the most feasible solution for seismic rehabilitation of such buildings.

  • PDF

Effect of Bouc-Wen Model and Earthquake Characteristics for Responses of Seismically Isolated Nuclear Power Plant by Lead-Rubber Bearing (납-고무 받침에 의해 면진된 원전구조물의 응답에 대한 Bouc-Wen 모델 및 지진특성의 영향)

  • Song, Jong-Keol;Son, Min-Kyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.95-103
    • /
    • 2017
  • In order to modeling seismic isolation system such as lead-rubber bearing (LRB), bilinear model is widely used by many researchers. In general, an actual force-displacement relationship for LRB has a smooth hysteretic shape. So, Bouc-Wen model with smooth hysteretic shape represents more accurately actual hysteretic shape than bilinear model. In this study, seismic responses for seismically isolated nuclear power plant (NPP) with LRB modelled by Bouc-Wen and bilinear models are compared with those of NPP without seismic isolation system. To evaluate effect of earthquake characteristics for seismic responses of NPP isolated by LRB, 5 different site class earthquakes distinguished by Geomatrix 3rd Letter Site Classification and artificially generated earthquakes corresponding to standard design spectrum by Reg. Guide 1.60 are used as input earthquakes. From the seismic response results of seismically isolated NPP, it can be observed that maximum displacements of seismic isolation modelled by Bouc-Wen model are larger than those by bilinear model. Seismic responses of NPP with LRB is significantly reduced than those without LRB. This reduction effect for seismic responses of NPP subjected to Site A (rock) earthquakes is larger than that to Site E (soft soil) earthquakes.

Design of Pulse Tranceiver for Antipodal Ultra Wideband System (Antipodal 초광대역 통신 시스템의 변·복조기 설계)

  • Lee, Jung Suk;Kim, Yoo Chang;Kim, Won Hoo
    • Journal of Advanced Navigation Technology
    • /
    • v.5 no.2
    • /
    • pp.134-140
    • /
    • 2001
  • Ultra Wideband(UWB) system uses wide band signal, which power spectral density likes as a noise floor, so UWB system can be used high speed communication without interfering with other communication system. As this system doesn't use carrier, its structure would be very simple and consume very low power. But conventional UWB system uses Pulse Positioning Modulation(PPM) Method. Therefore it could be to produce discrete power spectrum which decreases system efficiency unintentionally. For eliminating discrete power spectrum and further Euclidean distance, we propose UWB system using Antipodal signal. And we design and simulate antipodal tranceiver using Advanced Design System(ADS).

  • PDF

Optimal earthquake intensity measures for probabilistic seismic demand models of ARP1400 reactor containment building

  • Nguyen, Duy-Duan;Thusa, Bidhek;Azad, Md Samdani;Tran, Viet-Linh;Lee, Tae-Hyung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4179-4188
    • /
    • 2021
  • This study identifies efficient earthquake intensity measures (IMs) for seismic performances and fragility evaluations of the reactor containment building (RCB) in the advanced power reactor 1400 (APR1400) nuclear power plant (NPP). The computational model of RCB is constructed using the beam-truss model (BTM) for nonlinear analyses. A total of 90 ground motion records and 20 different IMs are employed for numerical analyses. A series of nonlinear time-history analyses are performed to monitor maximum floor displacements and accelerations of RCB. Then, probabilistic seismic demand models of RCB are developed for each IM. Statistical parameters including coefficient of determination (R2), dispersion (i.e. standard deviation), practicality, and proficiency are calculated to recognize strongly correlated IMs with the seismic performance of the NPP structure. The numerical results show that the optimal IMs are spectral acceleration, spectral velocity, spectral displacement at the fundamental period, acceleration spectrum intensity, effective peak acceleration, peak ground acceleration, A95, and sustained maximum acceleration. Moreover, weakly related IMs to the seismic performance of RCB are peak ground displacement, root-mean-square of displacement, specific energy density, root-mean-square of velocity, peak ground velocity, Housner intensity, velocity spectrum intensity, and sustained maximum velocity. Finally, a set of fragility curves of RCB are developed for optimal IMs.

Application of Response Spectrum Method for Analysis of a Floor System Subjected to Dynamic Loads on Multiple Locations (복수 절점에 가진되는 건물 바닥판의 해석을 위한 응답스펙트럼 해석법의 응용)

  • 김태호;이동근
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.21-32
    • /
    • 2002
  • In general, the response spectrum analysis method (R.S.A) is widely used for seismic analysis of building structure. But, it is not common to apply R.S.A for the analysis of structural vibration caused by dynamic loads of equipments, machines and moving leads, etc. The time history analysis method(T.H.A) for the vibration analysis, compared with R.S.A, is very complex, difficult and time consuming. So the application of R.S.A, that is convenient to calculate maximum responses for structural vibration, is proposed in this study. At first, the procedure for the application of the R.S.A to calculate of the maximum vibration response induced by dynamic load applied on the single point is described. And then, the process, which can save the time and the memory for calculation of the maximum vibration response induced by dynamic loads on the multi-point is proposed, and the maximum structural response caused by moving loads are obtained. Lastly, the accuracy of the proposed method is verified by comparing the results of R.S.A to T.H.A for some example models.

Spatial Variation Characteristics of Seismic Motions through Analysis of Earthquake Records at Fukushima Nuclear Power Plant (후쿠시마 원자력발전소 지진 계측 기록 분석을 통한 지진파의 공간적 변화 특성 평가)

  • Ha, Jeong-Gon;Kim, Mi Rae;Kim, Min Kyu
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.5
    • /
    • pp.223-232
    • /
    • 2021
  • The spatial variation characteristics of seismic motions at the nuclear power plant's site and structures were analyzed using earthquake records obtained at the Fukushima nuclear power plant during the Great East Japan Earthquake. The ground responses amplified as they approached the soil surface from the lower rock surface, and the amplification occurred intensively at about 50 m near the ground. Due to the soil layer's nonlinear characteristics caused by the strong seismic motion, the ground's natural frequency derived from the response spectrum ratio appeared to be smaller than that calculated from the shear wave velocity profile. The spatial variation of the peak ground acceleration at the ground surface of the power plant site showed a significant difference of about 0.6 g at the maximum. As a result of comparing the response spectrums at the basement of the structure with the design response spectrum, there was a large variability by each power plant unit. The difference was more significant in the Fukushima Daiichi site record, which showed larger peak ground acceleration at the surface. The earthquake motions input to the basement of the structure amplified according to the structure's height. The natural frequency obtained from the recorded results was lower than that indicated in the previous research. Also, the floor response spectrum change according to the location at the same height was investigated. The vertical response on the foundation surface showed a significant difference in spectral acceleration depending on the location. The amplified response in the structure showed a different variability depending on the type of structure and the target frequency.

Design of a Seismic Isolation Table for both indoor and outdoor Electrical Communication Equipment (전기통신설비를 위한 옥내외 겸용 면진테이블 설계)

  • Lee, Chun-Se;Ahn, Hyeong-Joon;Lee, Taek-Won;Son, In-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.472-472
    • /
    • 2009
  • The safety of cultural properties, medical treatment and electrical communication equipments in a building was hardly considered against the earthquake induced vibration, while the integrity of the building structure has been taken into account through the resistant earthquake design. This paper presents design of a seismic isolation table for both indoor and outdoor electrical communication equipment. First of all, artificial earthquake waves compatible with floor and ground response spectra for electrical communication equipments are generated using previously recorded seismic waves. Two kinds of one-degree-of-freedom seismic isolation table systems: spring-linear damper and spring-friction damper systems are considered and their responses to artificial earthquake waves are simulated. Design parameter study for two seismic isolation tables are performed through simulations and a seismic isolation table for both indoor and outdoor electrical communication equipment is designed considering the simulation results.

  • PDF

Multi-Step Analysis of Seismically Isolated NPP Containment Structures with Lead-Rubber Bearings (납-고무받침에 의해 면진된 원전 격납구조물의 다중단계해석)

  • Lee, Jin Hi;Song, Jong-Keol;Lee, Eun-Haeng
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.261-269
    • /
    • 2014
  • In order to increase the seismic safety of nuclear power plant (NPP) structures in high seismicity regions, seismic isolation techniques can be adapted to NPP structures. In this paper, the applicability of multi-step analysis of seismically isolated NPP containment structures with lead-rubber bearings (LRB) is evaluated. The floor response spectrum of NPP containment structures with equivalent linear LRB and nonlinear LRB are compared. In addition, the force-displacement relationships for equivalent linear LRB and nonlinear LRB are compared.

Subtraction of excess noise in a gyroscope employing a high-power erbium-doped fiber source (고출력 Erbium 첨가 광섬유 광원을 사용하는 자이로스코프에서 광원 과잉잡음의 소거)

  • 진영준;박태용;박희갑
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.396-400
    • /
    • 1999
  • In the fiber-optic gyroscope employing a high-power erbium-doped fiber source, the source excess noise was subtracted from the gyro output through a single processing to improve the gyroscope sensitivity. As the result, we obtained the reduction of noise by 13.5 dB (electrical) which was measured from the noise floor spectrum when the gyro was modulated with the depth of 1.8 rad. In addition, the random walk coefficient of the gyro output was reduced by a factor of 4~5.

  • PDF

Comparison of The Attenuation Measurement Methods for Electromagnetic Partial Discharge Signal in 25.8 kV Gas Insulated Switchgear (25.8 kV GIS에서 전자기파 부분방전신호 감쇠특성 측정방법 비교)

  • Goo, Sun-Geun;Han, Ki-Sun;Kwak, Joo-Sik;Joo, Hyung-Jun;Jeong, Moon-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1281-1287
    • /
    • 2015
  • We report the characteristics and differences of two types of attenuation measurement methods for electromagnetic partial discharge signal in GIS. The pulse method is to measure the attenuated waveforms in time domain and coverts them into frequency domain to get the attenuation spectra of given GIS section. This method simulates the real partial discharge signal. The frequency swept continuous wave method can obtain attenuation spectra directly so that it gives attenuation with low noise floor and simplicity. We show that both methods are effective and exchangeable because the attenuation results measured by two methods have similar trends