• Title/Summary/Keyword: Floor level

Search Result 818, Processing Time 0.025 seconds

Comparison of Ventilation Efficiency in an Enclosed and Conventional Growing-Finishing Pig House (개방형과 무창형 육성비육돈사의 환기효율 비교)

  • Song, J.I.;Choi, D.Y.;Jung, J.W.;Yang, C.B.;Choi, H.L.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.3
    • /
    • pp.459-468
    • /
    • 2004
  • An experiment was conducted to establish comparison of ventulation efficiency in an enclosed and conventional growing-finishing pig house. The main results of the experiment are as follows : In the established temperature was sustained at the level of summer 24.8${\sim}$29.1$^{\circ}C$, winter 17.9${\sim}$23.1$^{\circ}C$ during the experimental period of enclosed growing-finishing pig house, and conventional growing-finishing pig house was at the lovel of summer 24.7${\sim}$32.3$^{\circ}C$, winter 14.5${\sim}$18.2$^{\circ}C$ during the experimental period respectively. As for the results of dertimental gas(ammonia) concentration ratio analysis, while the conventional pig house sustained of summer 9.3${\sim}$16.9 mg/$\ell$ level, enclosed growing-finishing pig house sustained of summer 7.9${\sim}$16.1 mg/$\ell$, and the latter one is lower than that of the conventional growing-finishing pig house. Air flow rate on the floor level which is the low part of pen and the active area of pigs in the enclosed growing and finishing pig house during winter was measured at 0 to 0.87 m/s at the 0.01 to 2.73 m/s at the maximum ventilation efficiency. As for breeding pigs in summer, the pigs from the conventional pig house weighed 100.2kg, on the other hand, the pigs from enclosed growing-finishing pig house weighed 107.3 kg ; the differnce between the two kinds was about 7 kg. This was because the most adequate environment, which was not influenced by the exterior atmosphere, was offered to the pigs from enclosed growing-finishing pig house, and all of this could reduce pigs stress effectively.

Tibial Torsion in Children of the Jeju Area (제주지역 소아의 경골 염전)

  • Song, Dong Ho;Eun, Baik-Lin;Park, Sang Hee;Lee, Joon Young;Tockgo, Young Chang
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.1
    • /
    • pp.75-80
    • /
    • 2005
  • Purpose : Internal tibial torsion is prevalent in East Asian countries such as Korea and Japan, where sitting on the floor is common behavior. Internal tibial torsion or excessive lateral tibial torsion may cause esthetical, functional, or psychological problems and also may induce degenerative arthritis in older age. The purpose of this study is to measure the tibial torsion in children of the Jeju area. Methods : Tibial torsion was measured in 1,042 lower extremities of 521 children from one to 12 years of age. The values of transmalleolar angles were analyzed for each age group divided by 6 months. Quadratic and linear regression models were used to fit patterns of changes in mean values of transmalleolar angles. The age at seven, which provides the highest coefficient of determination for quadratic regression analysis, was used as a cut-off point to fit different statistical models. Results : The mean transmalleolar angle was $0.10{\pm}5.79^{\circ}$ in all children,$ 0.90{\pm}5.49^{\circ}$ in males, and $-0.80{\pm}5.97^{\circ}$ in females. The value was $4.25{\pm}4.04$ in 1 year of age, gradually decreased to the lowest level of $-1.98^{\circ}$ in four years and seven months of age, increased again with age until it reached $0.67{\pm}1.10^{\circ}$ at seven years of age, and stayed at that level thereafter. Conclusion : Internal tibial torsion in infancy is known to correct spontaneously in the normal developing process. But in this study, the mean transmalleolar angle in children of Jeju area annually decreased after one year of age; to the lowest angle at four years and seven months of age; increased again gradually to the age of seven; and persisted in that level, about $10^{\circ}$ less than western children, not correcting further thereafter. These findings suggest tibial torsion might be caused by lifestyle, especially sitting on feet. To prevent abnormalities of joints and gaits, early diagnosis of tibial torsion in childhood and posture correction or early treatment when needed, seems to be necessary.

A Study on thinner's Physicochemical property and its effect on genital organ of rat (시너(thinner)의 물리화학적 특성과 랫트의 생식기에 미치는 영향 연구)

  • Kim, Hyeon-Yeong;Lee, Sung-Bae;Han, Jeong-Hee;Kim, Tae-Gyun;Lee, Jung-Suk;Kang, Min-Gu;Lee, Chae-Kwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.224-238
    • /
    • 2008
  • The aim of this study is to confirm the physicochemical property and hazard of thinner (012), which is a diluent of enamel paint used for floor coating for waterproofing and oil painting for the outer wall. The literatures of physicochemical property and hazard of thinner were surveyed and its physicochemical property were evaluated. And then, the inhalation toxicity of thinner affecting the central nervous system and reproductive organs in rats were examined by subchronic (6 h./day. 5 days/ week for 13 weeks) inhalation test. 1) According to the 13-week subchronic inhalation test, there were no significant changes in clinical test and body weight. However, a significant evidence of toxicity was observed in the hematological test and organ weight such as heart, kidney, liver and brain (p<0.01) in the 200 ppm and 1,000 ppm exposure groups in a dose response manner. In the histopathology analysis, there were no significant evidence of toxicity. Therefore, thinner was not classified as an organ targeted toxic agent. In case of Harmfulness, it could be classified as a chronic toxic agent 3($500 ppm/4hr, rat). 2) The reproductive toxicity such as extension of the period of estrous cycle, reduction of serum estradiol concentration and increase of frequency of the abnormal sperm was observed in the 1,000 ppm exposed animals. 3) The result of the physicochemical property of the test material showed that the specific gravity was 0.793, boiling point $155.8^{\circ}C$, steam pressure 2.1 kPa, ignition point $34.5^{\circ}C$, and spontaneous ignition point $280^{\circ}C$. The endothermic and exothermic values were 371.4 J/g and 159.1 J/g. respectively. The explosion limit was 214 mg/l. These data showed that thinner could be classified as an explosion agent level 1.2 and ignitive liquid agent 3 ($23-60^{\circ}C$) according to the notification No. 2008-1 of the Labor Ministry, "Classifying Standard of Chemical Materials."

Exposure status of welding fumes for operators of overhead traveling crane in a shipyard (대형조선소 천장크레인 운전원의 용접흄 노출 실태)

  • Lee, Kyeongmin;Kim, Boowook;Kwak, Hyunseok;Ha, Hyunchul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.301-311
    • /
    • 2015
  • Objectives: Operators of overhead traveling crane in a ship assembly factory perform work to transmit large vessel blocks to an appropriate working process. Hazardous matters such as metal dusts, carbon monoxide, carbon dioxide, ozone, loud noise and fine particles are generated by variable working activities in the factory. The operators could be exposed to the hazardous matters during the work. In particular, welding fumes comprised of ultra fine particles and heavy metals is extremely hazardous for humans when exposing a pulmonary through respiratory pathway. Occupational lung diseases related to welding fumes are increasingly on an upward tendency. Therefore, the objective of this study is to assess properly unknown occupational exposure to the welding fumes among the operators. Methods: This study intended to clearly determine an equivalence check whether or not chemical constituents and composition of the dusts, which existed in the driver's cab, matched up with generally known welding fumes. Furthermore, computational fluid dynamics program(CFD) was used to identify a ventilation assessment in respect of a contamination distribution of welding fumes in the air. The operators were investigated to assess personal exposure levels of welding fumes and respirable particulate. Results: The dust in an operation room were the same constituents and composition as welding fumes. Welding fumes, which caused by the welding in a floor of the factory, arose with an ascending air current up to a roof and then stayed for a long time. They were considered to be exposed to the welding fumes in the operation room. The personal exposure levels of welding fumes and respirable particulate were 0.159(n=8, range=0.073-0.410) $mg/m^3$ and 0.138(n=8, range=0.087-0.178) $mg/m^3$, respectively. They were lower than a threshold limit value level($5mg/m^3$) of welding fumes. Conclusions: These findings indicate that an occupational exposure to welding fumes can exist among the operators. Consequently, we need to be keeping the operators under a constant assessment in the operator process of overhead traveling crane.

Surgical Repair of Achilles Tendon Rupture by Minimal Incision Technique (최소 절개 기법에 의한 아킬레스건 파열의 수술적 봉합술)

  • Jung, Hong-Geun;Paik, Ho-Dong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.2
    • /
    • pp.173-178
    • /
    • 2005
  • Propose: There have been many debates about the ideal surgical technique for acute Achilles tendon rupture. The purpose of this study is to review and analyze the clinical outcome of the acute Achilles tendon ruptures that had been repaired by indirect suture technique with minimal incision that utilized an instrument called Achillon (Newdeal, France). Materials and Methods: This study is based on the 14 cases (14 patients) of acute Achilles tendon total ruptures that have been repaired by minimal incision technique utilizing Achillon instrument from June 2003 to December 2004. Two cases were reruptured before 8 weeks and repaired again using Krackow suture which left 12 feet for postoperative functional evaluation with at least 6 months of follow-up. Ten cases were men and average age at time of injury was 34.4 (26-49) years. The time from injury to surgery was an average of 4.5 (1-9) days and the postoperative evaluations were done by an Arner-Lindholm scale and AOFAS score. The ability to return to original work and sports activities as well as patient satisfaction were also evaluated. Results: The follow-up period was averaged for 13.2 (6-24) months. Seventy-one percent of cases were ruptured during sports activities. The ruptured level was the average of 5.1 cm (3.2-8 cm) above calcaneal attachment and the skin incision was averaged for 2.7 cm (2.5-3.0 cm) long. At final follow-up, standing on tip-toe was possible in all cases while the heel-floor height on ruptured side was shorter by 0.7 cm (0-2 cm). By Arner-Lindholm evaluation scale, 9 cases were excellent, and 3 cases were good. Overall AOFAS score was an average of 96.1 (94-100), and all patients were satisfied with the result. Patients returned to work at an average of 1.3 months after the surgery and pre-injury sports activities were all possible from at 6 months after operation. Conclusion: Since we have treated acute Achilles tendon ruptures with minimal incision technique utilizing the Achillon and gained encouraging functional results with all patients returning to previous work with high patient satisfaction, this technique could be recommended as one of the ideal surgical options for the Achilles tendon ruptures.

  • PDF

Comparison of Muscle Activity During a Push-up on a Suspension Sling and a Fixed Support (슬링(sling)과 고정된 지지면에서의 팔굽혀펴기 동작 시 근 활성도 비교)

  • Oh, Jae-Seop;Park, Jun-Sang;Kim, Suhn-Yeop;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.10 no.3
    • /
    • pp.29-40
    • /
    • 2003
  • The purpose of this study was to compare the muscle activity during a push-up on a suspension sling and a fixed support at the same level. Tests were performed on 15 male subjects. Electromyography using a surface EMG recorded the activity of the triceps, pectoralis major, and internal and external oblique muscles during each push-up. EMG activity was recorded at 0, 45, and 90 degrees of elbow flexion in the push-up position on a suspension sling or a fixed support at the same height above the floor (30 cm). The testing order was selected randomly. The subjects were asked to maintain the push-up position with straight knees, hips, and trunk for 5 seconds at each elbow angle. The mean root mean square (RMS) of EMG activity was calculated. EMG activity was normalized using the maximum voluntary isometric contractιn elicited using a manual muscle testing technique. Two-factor repeated measures analysis of variance (ANOVA) was used to compare the average RMS value of EMG activity for each condition. The EMG activity for the pectoralis major, and internal and external oblique muscles during a push-up on a sling was significantly higher than on a fixed support at all angles of elbow flexion (p<.01). There were significant differences in the EMG activity of the pectoralis major and triceps brachii muscles at difference angles of elbow flexion (p<.05). The pectoralis major muscle had the highest EMG activity at 90 degrees of elbow flexion on both the sling and fixed support. The triceps brachii muscle had the highest EMG activity at 45 degrees of elbow flexion on both the sling and fixed support. The internal and external oblique muscles had the highest EMG activity at 0 degrees of elbow flexion, although the difference with angle of flexion was not significant. These results suggest that to improve proximal and trunk stability and muscle strength, push-ups are more useful when performed on a suspension sling than On a fixed support.

  • PDF

A Case Study on Economic Analysis of a Solar Water Heating System and a Ground Source Heat Pump System Applied to a Military Building (군 복지시설의 지열시스템과 태양열시스템 경제성 평가 사례 연구)

  • Lee, Jong-Chan;Park, Young-Ho;Lee, Ghang;Lee, Sang-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.4
    • /
    • pp.111-118
    • /
    • 2009
  • This study is to analyze the performance of SWH(Solar Water Heating) and GSHP(Ground Source Heat Pump) systems by evaluating their energy efficiency and LCC(Life Cycle Cost) as being applied to the OO hall as a selected building in the Army. The OO hall, used as bathrooms, dining rooms, accommodations and offices, has reinforced concrete structure system with three floors above the ground and one underground, and its total floor area is approximately 2,917$m^2$. Two energy simulations are conducted to predict the yearly cooling and heating energy of the selected building: One is for analysis of an air-conditioning energy consumption using the e-Quest program, and another is for two new-renewable energy facilities as a water heating source using the RETScreen. The installed capacity of two new-renewable energy facilities is determined according to the 5% level of total standard construction cost. As a briefly result, SWH system is more energy-effective than GSHP system. Considering the break-even point, it is expected that SWH can take only 3 years 11 months to pay for itself in savings while the investment of GSHP can be recovered in more than 16 years 6 months.

A Study on Foodservice Facilities, Utilities, and Physical Environment in the Chonbuk Area of Korea (전북 지역 학교급식소의 시설.설비 및 물리적 환경에 대한 연구)

  • Kook, Sook-Ja;Choi, Byung-Sook;Rho, Jeong-Ok
    • The Korean Journal of Food And Nutrition
    • /
    • v.22 no.4
    • /
    • pp.497-507
    • /
    • 2009
  • The principal objective of this study was to assess the situation of foodservice facilities, utilities, and physical environment in the Chonbuk area. Self-administered questionnaires were collected from 252 nutrition teachers and school dietitians. Statistical data analysis was completed using the SPSS v. 11.5 program. The results were summarized as follows: Approximately 99.2% of the subjects were women 76.6% were married, over 87% were between the ages of 30 and 40(p<0.01) and 56.8% had more than 11 years of experience(p<0.001). Among the 252 school foodservice systems evaluated, 51.6% of the schools were located in urban areas and 48.0% were in rural areas(p<0.01). Approximately 68.0% of the schools prepared meals in the conventional way, and 32.3% prepared them in the commissary way(p<0.001). The number of employees at each institution was separated into the following categories: 1 to 3(37.7%), 4 to 6(27.8%), and 7 to 9(25.4%, p<0.01). Approximately 54.0% of schools had been running a school meal service for longer than 11 years(p<0.001). However, 67.5% of those facilities had not been remodeled since the initial implementation of foodservices. Approximately 94.0% of the school foodservice facilities were located on the first floor. 72.2% among them were constructed of reinforced concrete and 16.7% were prefabricated(p<0.001). As the result of our evaluation of related physical evidence and the atmosphere of the space, the average importance grade was $4.41{\pm}0.46$, and the average performance grade was $2.78{\pm}0.67$. Most nutrition teachers and school dietitians in elementary, middle, & high schools responded that the related physical evidence and the atmosphere of the space in school foodservice facilities were important, but the satisfaction level among the nutrition teachers and school dietitians was quite low. Therefore, it's important and necessary to analyze the opinions of the stakeholders in the foodservice industry prior to the remodeling of school foodservice facilities and utilities.

Evaluation of Ventilation Systems in an Enclosed Growing Pig House (무창육성돈사의 환기시스템에 따른 환기효율 평가)

  • Song, J.I.;Choi, H.L.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.135-144
    • /
    • 2002
  • An experiment was conducted to evaluate a ventilation system, which was devised to encourage farmers to use the enclosed growing and finishing pig housing system. A roof-air-entry ventilation system in winter and a side-wall-air-entry system in summer were evaluated. Air flow rate on the floor level which is the low part of pen and the living area of pigs in the enclosed growing and finishing pig house during winter was measured at 0 to 0.19 m/s at the minimum ventilation efficiency of 1,440 $m^{3}/h$. During summer the air flow rate was detected at 0.07 to 0.42 m/s at the maximum ventilation efficiency of 24,000 $m^{3}/h$. Therefore, it is concluded that the side-wall ventilation system is suitable for growing and finishing pigs in the enclosed house during the days of mid-summer and the roof-ventilation system was suitable during the coldest days of mid-winter. In addition, although the enclosed pig house has the system in which air exhausts through only one side wall, air should enter through both-side walls for the better ventilation performance.

Need Survey of Home Modification on Outpatient with Stroke and Spinal Cord Injury in Rehabilitation Center (재활치료를 받는 뇌졸중과 척추손상 외래환자들의 주거환경개선에 대한 요구도 조사)

  • Lim, Kyung-Min;Lee, Yu-Na
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.324-333
    • /
    • 2013
  • The purpose of this study was to investigate the need of home modification for outpatient with stroke and spinal cord injury. The subjects of this study were 54 outpatients who have experience in rehabilitation therapy at hospitals in Seoul and Gyeonggi-do. A questionnaire was distributed and collected form January 2th to February 4th, 2012. Descriptive statistics and $x^2$-test were used to analyze data. There were statistically significant difference in stairs of access, in width of front door, in bathroom, space of room according diagnosis. There were statistically significant difference in light of sensor, tissue holder and socket cover in bathroom for the comparison of demands for home modification by living type. There were statistically significant difference in width and threshold of front door, tissue holder and towel bar, nonslip floor in bathroom, space and table, chair of kitchen, space and threshold of porch, light for the comparison of demands for home modification according score of MBI. Based on the results of the survey, needs of home modification is different according disability level, diagnosis, living type, ADL performance. The results of this study show a need for the further occupational therapy of home modification and supporting policies in home modification.