• Title/Summary/Keyword: Floor level

Search Result 818, Processing Time 0.023 seconds

Improvement of Calculating Method of the Officially Assessed Individual House Price of Aged Apartment Remodeling Reflecting Feasibility Analysis (사업성분석을 반영한 공동주택 맞춤형 리모델링의 공시가격 산정방법 개선)

  • Bae, Byungyun;Kim, Kyungrai;Shin, Dongwoo;Cha, Heesung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.6
    • /
    • pp.89-97
    • /
    • 2017
  • The number of Aged Apartment units is expected to increase as time went on. Living standards are getting better and they want a new apartment space as the economy progresses. Therefore, it is necessary to prepare for the increasing remodeling market through the feasibility evaluation method that can be applied to the remodeling project of the apartment house. The purpose of this study is to analyze the social pricing factors affecting the Officially assessed individual House Price for the analysis model of commercial house remodeling. The collected samples were analyzed using multiple regression analysis of 350 prices included in 127 lots. Middle school level, high school level, total number of households, and floor area ratio were extracted. As a result of comparing the Officially assessed individual House Price by applying to the remodeling case, the difference between the existing Officially assessed individual House Price and the improvement Officially assessed individual House Price is different. The accessibility with the subway station is included in the land price, and there is no change in the number of stories and directions because it is customized remodeling. There was a difference in the disclosure price depending on the type of factor extraction by the evaluator in a batch application of the disclosure price factors. The research can be used as a model for future remodeling business feasibility analysis.

Application of Gamma Ray Densitometry in Powder Metallurgy

  • Schileper, Georg
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2002.07a
    • /
    • pp.25-37
    • /
    • 2002
  • The most important industrial application of gamma radiation in characterizing green compacts is the determination of the density. Examples are given where this method is applied in manufacturing technical components in powder metallurgy. The requirements imposed by modern quality management systems and operation by the workforce in industrial production are described. The accuracy of measurement achieved with this method is demonstrated and a comparison is given with other test methods to measure the density. The advantages and limitations of gamma ray densitometry are outlined. The gamma ray densitometer measures the attenuation of gamma radiation penetrating the test parts (Fig. 1). As the capability of compacts to absorb this type of radiation depends on their density, the attenuation of gamma radiation can serve as a measure of the density. The volume of the part being tested is defined by the size of the aperture screeniing out the radiation. It is a channel with the cross section of the aperture whose length is the height of the test part. The intensity of the radiation identified by the detector is the quantity used to determine the material density. Gamma ray densitometry can equally be performed on green compacts as well as on sintered components. Neither special preparation of test parts nor skilled personnel is required to perform the measurement; neither liquids nor other harmful substances are involved. When parts are exhibiting local density variations, which is normally the case in powder compaction, sectional densities can be determined in different parts of the sample without cutting it into pieces. The test is non-destructive, i.e. the parts can still be used after the measurement and do not have to be scrapped. The measurement is controlled by a special PC based software. All results are available for further processing by in-house quality documentation and supervision of measurements. Tool setting for multi-level components can be much improved by using this test method. When a densitometer is installed on the press shop floor, it can be operated by the tool setter himself. Then he can return to the press and immediately implement the corrections. Transfer of sample parts to the lab for density testing can be eliminated and results for the correction of tool settings are more readily available. This helps to reduce the time required for tool setting and clearly improves the productivity of powder presses. The range of materials where this method can be successfully applied covers almost the entire periodic system of the elements. It reaches from the light elements such as graphite via light metals (AI, Mg, Li, Ti) and their alloys, ceramics ($AI_20_3$, SiC, Si_3N_4, $Zr0_2$, ...), magnetic materials (hard and soft ferrites, AlNiCo, Nd-Fe-B, ...), metals including iron and alloy steels, Cu, Ni and Co based alloys to refractory and heavy metals (W, Mo, ...) as well as hardmetals. The gamma radiation required for the measurement is generated by radioactive sources which are produced by nuclear technology. These nuclear materials are safely encapsulated in stainless steel capsules so that no radioactive material can escape from the protective shielding container. The gamma ray densitometer is subject to the strict regulations for the use of radioactive materials. The radiation shield is so effective that there is no elevation of the natural radiation level outside the instrument. Personal dosimetry by the operating personnel is not required. Even in case of malfunction, loss of power and incorrect operation, the escape of gamma radiation from the instrument is positively prevented.

  • PDF

The Last Interglacial Sea Levels Estimated from the Morphostratigraphic Comparison of the Late Pleistocene Fluvial Terraces in the Eastern Coast of Korea (한국 동해안에 있어서 최종간빙기의 구정선고도 연구 후기 경신세 하성단구의 지형층서적 대비의 관점에서)

  • 최성길
    • The Korean Journal of Quaternary Research
    • /
    • v.7 no.1
    • /
    • pp.1-26
    • /
    • 1993
  • The estimation of the Last Interglacial sea level was made by using the thalassostatic terrace which had been developed in the lower reach of Namdaechon river in Kangneung, eastern coastal area of Korea. The fluvial terraces, which have been developed since late Pleistocene, were investigated. The main findings were as follows; 1) That Kangneung terrace I had been formed in the climax period of the Last Interglacial (Oxygen isotope stage 5e) was revealed. It was estimated that Kangneung terrace II had been formed during a certain warmer period between the climax period of the Last Interglacial and the early Last Glacial(probably Oxygen isotope stage 5c or 5a). 2) Being judged from the relative heights of the Kangneung terrace I and II, the sea levels of the formation periods of these terraces were estimated to have been relatively 17~20m and l0m higher than the present sea level, respectively. 3) The formation periods of the Wangsan terrace I and II were supposed to be the early and late Last Glacial respectively, being judged from the following 3 details ; a) the characteristics of the terrace deposits, b) the relation Wangsan terrace II to the buried valley floor, and c) the cross phenomena of the above two terraces to the Kangneung terraces. 4) The formation period of the pseudogleyed red soil in the Kangneung terrace I was estimated to be the middle or late period of the Last Interglacial.

  • PDF

Paleoclimatic Implication of Cave Speleothems in the Submerged Parts of the Seongnyu Cave, Republic of Korea (성류굴 내 호수구간의 수중통로에서 발견되는 동굴생성물의 고기후적 의미)

  • Kim, Ryeon;Woo, Kyung-Sik;Kim, Bong-Hyeon;Park, Jae-Suk;Park, Hun-Young;Jeong, Hee-Jeong;Lee, Jong-Hee
    • The Korean Journal of Quaternary Research
    • /
    • v.24 no.1
    • /
    • pp.11-24
    • /
    • 2010
  • Seongnyu Cave have developed along the NE-SW direction in carbonate rocks of the Joseon Supergroup. The cave mostly shows horizontal passages and contains three lakes. The main passage is about 330 m long with 540 m-long branches, thus the total length of the cave is about 870 m. Through cave diving, about 85 m-long new passages were discovered. Numerous speleothems such as soda straws, stalactites, stalagmites, columns, flowstones, rimstones, cave shields, cave corals, curtains (and bacon sheets), cave pearls, cave flowers, helictites and calcite rafts can be found in the cave. Especially, some speleothems which were believed to have grown in the past were discovered in the submerged passage, and a few stalactites, stalagmites, flowstones and columns were eroded (or corroded) by the cave stream that flowed on the floor. Because these speleothems only grow in subaerial environments within limestone caves, it appears that they grew when there was no lake in the cave and became submerged as the lake level rose in the cave. The presence of these speleothems in the lakes indicate that they only grew during glacial periods when sea-level was lower. Therefore, detailed investigation of these speleothems will provide invaluable information on paleoclimatic evolution around the Korean peninsula in the future.

  • PDF

Preparation of Styrene-Ethyl acylate Core-shell Structured Detection Materials for aMeasurement of the Wall Contamination by Emulsion Polymerization

  • Hwang, Ho-Sang;Seo, Bum-Kyoung;Lee, Dong-Gyu;Lee, Kune-Woo
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.06a
    • /
    • pp.84-85
    • /
    • 2009
  • New approaches for detecting, preventing and remedying environmental damage are important for protection of the environment. Procedures must be developed and implemented to reduce the amount of waste produced in chemical processes, to detect the presence and/or concentration of contaminants and decontaminate fouled environments. Contamination can be classified into three general types: airborne, surface and structural. The most dangerous type is airborne contamination, because of the opportunity for inhalation and ingestion. The second most dangerous type is surface contamination. Surface contamination can be transferred to workers by casual contact and if disturbed can easily be made airborne. The decontamination of the surface in the nuclear facilities has been widely studied with particular emphasis on small and large surfaces. The amount of wastes being produced during decommissioning of nuclear facilities is much higher than the total wastes cumulated during operation. And, the process of decommissioning has a strong possibility of personal's exposure and emission to environment of the radioactive contaminants, requiring through monitoring and estimation of radiation and radioactivity. So, it is important to monitor the radioactive contamination level of the nuclear facilities for the determination of the decontamination method, the establishment of the decommissioning planning, and the worker's safety. But it is very difficult to measure the surface contamination of the floor and wall in the highly contaminated facilities. In this study, the poly(styrene-ethyl acrylate) [poly(St-EA)] core-shell composite polymer for measurement of the radioactive contamination was synthesized by the method of emulsion polymerization. The morphology of the poly(St-EA) composite emulsion particle was core-shell structure, with polystyrene (PS)as the core and poly(ethyl acrylate) (PEA) as the shell. Core-shell polymers of styrene (St)/ethyl acrylate (EA) pair were prepared by sequential emulsion polymerization in the presence of sodium dodecyl sulfate (SOS) as an emulsifier using ammonium persulfate (APS) as an initiator. The polymer was made by impregnating organic scintillators, 2,5-diphenyloxazole (PPO) and 1,4-bis[5-phenyl-2-oxazol]benzene (POPOP). Related tests and analysis confirmed the success in synthesis of composite polymer. The products are characterized by IT-IR spectroscopy, TGA that were used, respectively, to show the structure, the thermal stability of the prepared polymer. Two-phase particles with a core-shell structure were obtained in experiments where the estimated glass transition temperature and the morphologies of emulsion particles. Radiation pollution level the detection about under using examined the beta rays. The morphology of the poly(St-EA) composite polymer synthesized by the method of emulsion polymerization was a core-shell structure, as shown in Fig. 1. Core-shell materials consist of a core structural domain covered by a shell domain. Clearly, the entire surface of PS core was covered by PEA. The inner region was a PS core and the outer region was a PEA shell. The particle size distribution showed similar in the range 350-360 nm.

  • PDF

Analysis of Current Situation for Environmental Facilities and Disinfection in Hanwoo Farms (한우농가의 환경시설관리 및 방역실태 분석)

  • Kim, Gye-Woong;Kim, Kon-Joong
    • Journal of Animal Environmental Science
    • /
    • v.17 no.2
    • /
    • pp.61-70
    • /
    • 2011
  • This survey was conducted to investigate the current situation of ground condition of barn, moisture condition, feeding facilities, disinfection tool, etc. The data from a total of 305 farms were collected and analysed for establishment of managemental target in Hanwoo farm. The ground condition of barn was evaluated as a result of "moderate level" (46.4%). The moisture removal on the ground was conducted with the aid of electric fan (36.4%). The natural wind and sunlight should be used gradually for economic effect in farm. The exchange of floor straw was mostly conducted to remove the bad smell of barn (33.7%). 37.0% of farms had no the electric fan in internal barn, this instrument must be installed for control of body temperature and internal moisture in the future. Most of feeding facilities were operated by hand(88.2%). Modern farms should be installed with automatic feeding system. Farmer's skill of management was evaluated as a "2.80" of 5 points. Accordingly, farmers should be trained with high level of technical competitive skill. In conclusion, Hanwoo farms should be promoted and improved for enhancement of income through introduction to scientifically modern feeding skill.

PSM based Price Estimating for Local Mixed-Use Apartment Development (PSM기반 중소도시 주상복합 아파트의 분양가 추정에 관한 연구)

  • Park, Jaekyung;Cho, Yongkyung;Lee, Sangyoub
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.4
    • /
    • pp.86-94
    • /
    • 2014
  • Since the late 1990s, mixed-use apartment, armed with high qualities and large scales with a high ratio of TFA(Total Floor Area) have been continuously provided accommodating exclusive community facilities along with high-tech securities, not to mention excellent skyline view. However, especially in mid-small cities, there have been only a few supplies. As a result, none of the mixed-use housing provided by high-end brands has ever been built in non-metropolitan area. But constructors couldn't plan the projects which aims to build the mixed-use apartment in local city, because they couldn't get the basic data or advanced research for feasibility analysis. Therefore, to suggest the useful price for mixed-use apartment supply project of local city, the PSM(Price Sensitivity Method) widely used for determining the price preferences as a market research tools has been applied. As analysis results, the estimated price of mixed-use apartment is 10.8% higher than general apartment, and mixed-use apartment has lower price sensitivity than general apartment. As price determinants, the age, education level and family size influence on UTP in significant level. It is expected that these research findings can be applied for establishing the solid marketing strategy of mixed-use apartment development project in local city.

The Effects of Lumbar Stabilizing Exercise on the Functional Recovery and the Range of Motion of Low Back Pain Patients (요부 안정화 운동이 요통환자의 기능회복과 가동범위에 미치는 영향)

  • Jung Yeon-Woo;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.157-182
    • /
    • 2004
  • The purpose of this study was to evaluate effects of lumbar stabilizing exercise on the functional recovery and the range of motion of low back pain patients. The subjects were consisted of sixty patients who had non specific chronic low back pain(32 females. 28 males; mean aged 37.3) from 19 to 65 years of age(mean age : 37.3). All subjects randomly assigned to the lumbar stabilizing exercise group, the modalities treatment group, the manual treatment group. Lumbar stabilizing exercise group received manual treatment with lumbar stabilizing exercise for 30minutes, modalities treatment group received hot pack used thermal therapy for 20minutes and ICT used electrical therapy for 20minutes and US or MWD used deep thermal therapy for 15minutes, manual treatment group received modalities treatment with therapeutic massage for 10minutes and joint mobilization or manipulation for 10minutes per day and three times a week during 4 weeks period. The Multilevel Roland-Morris Disability Questionnaire(MR-MDQ) was used to measure functional disability level. Visual Analogue Scale(VAS) was used to measure subjective pain level. Remodified Schober test(RST) was used to measure forward flexion range of motion of lumbar segment. Finger-to-Floor test(F-T-FT) was used to measure forward flexion range of motion of full spine of low back pain patients. All measurements of each patients were measured at pre-treatment and 4 week post-treatment. The results of this study were summarized as follows : 1. The MR-MDQ of lumbar stabilizing exercise group, modalities treatment group, and manual treatment group was significantly reduced between pre-treatment and post-treatment(p<.05). 2. The VAS of lumbar stabilizing exercise group, modalities treatment group, and manual treatment group was significantly reduced between pre-treatment and post-treatment(p<.05). 3. The RST of lumbar stabilizing exercise group, modalities treatment group, and manual treatment group was significantly reduced between pre-treatment and post-treatment(p<.05). 4. The F-T-FT of lumbar stabilizing exercise group, modalities treatment group, and manual treatment group was significantly reduced between pre-treatment and post-treatment(p<.05). 5. The results of analyzed effects of MR-MDQ, RST, F-T-FT were significantly reduced (p<.05), but VAS wasn't significantly reduced(p>.05) between treatment type of lumbar stabilizing exercise group and modalities treatment group and manual treatment group according to pre-treatment and post-treatment. 6. The results of LSD post-hoc to find difference between treatment type of lumbar stabilizing exercise group and modalities treatment group and manual treatment group according to pre-treatment and post-treatment that MR-MDQ was significantly reduced stabilizing exercise group than modalities treatment group(p<.05), and VAS wasn't significantly reduced all treatment group(p>.05), and RST was significantly reduced stabilizing exercise group than modalities treatment group(p<.05), and F-T-FT was significantly reduced stabilizing exercise group than modalities treatment group and manual treatment group (p<.05).

  • PDF

Development of Work Breakdown Structure and Analysis of Precedence Relations by Activity in School Facilities Construction Work (학교시설 건설공사의 작업분류체계 구축 및 단위작업별 선후행 관계 분석)

  • Bang, Jong-Dae;Sohn, Jeong-Rak
    • Land and Housing Review
    • /
    • v.8 no.3
    • /
    • pp.189-200
    • /
    • 2017
  • The work breakdown structure and the precedence relations by work activity are very important because they are the basic data for estimating the construction duration in the construction work. However, there is no standard to accurately estimate the construction duration since the size of the school facilities construction is smaller than the general construction work. Therefore, some schools are unable to open in March or September and the delay of the construction duration can cause damage to the students. To solve this problem, this study developed a work breakdown structure of school facilities construction work and analyzed the precedence relations by work activities. The work breakdown structure of the school facilities construction is composed of three steps. The operations corresponding to level 1 and level 2 are as follows. (1) 2 preparatory work categories; preparation period and temporary construction. (2) 17 architectural work categories; temporary construction, foundation & pile work, reinforced concrete work, steel roof work, brick work, plaster work, tile work, stone work, waterproof construction, wood work, interior construction, floor work, metal work, roof work, windows construction, glazing work and paint construction. (3) 7 mechanic and fire work categories; outside trunk line work, plumbing work, air-conditioning equipment work, machine room work, city gas plumbing work, sanitation facilities and inspection & test working. (4) 4 civil work categories; wastewater work, drainage work, pavement work and other work. (5) 1 landscaping work categories; planting work. The work breakdown structure was derived from interviews with experts based on the milestones and detailed statements of existing school facilities. The analysis of precedence relations by school facilities work activity utilized PDM(Precedence Diagramming Method)which does not need a dummy and the relations were applied using FS(Finish to Start), FF(Finish to Finish), SS(Start to Start), SF(Start to Finish). The analysis of this study shows that if one work activity is delayed, the entire construction duration may be delayed because the majority of the works are FS relations. Therefore, it is necessary to use the Lag at the appropriate time to estimate the standard construction duration of the school facility construction. Lag is a term used only in the PDM method and it is used to define the relationship between the predecessor and the successor in creating the network milestone. And it means the delay time applied to the two work activities. The results of this study can reasonably estimate the standard construction duration of school facilities and it will contribute to the quality of the school facilities construction.

Evaluation of Intensity of Extremely Low Frequency Magnetic Fields (ELF-MF) Inside of Cabins as Generated During Subway Operation (지하철 운행 중 발생하는 객차 내부 극저주파 자기장(ELF-MF) 세기 평가)

  • Lee, Jihyun;Kang, Myeongji;Park, Yunkyung;Park, Donguk;Choi, Sangjun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.2
    • /
    • pp.185-194
    • /
    • 2019
  • Objective: This study was conducted to investigate the intensity of the extremely low frequency magnetic fields(ELF-MF) generated inside of the cabins during subway operation. Methods: The ELF-MF intensity were investigated on 30 subway lines in Korea, including in the Greater Seoul Metropolitan Area(Seoul and Gyeonggi-do Province), Incheon, Busan, Daegu, Daejeon, and Gwangju. ELF-MF intensity was measured at 0.9 m from the floor using EMDEX II meters with a resolution of $0.01{\mu}T$. All data were collected every three seconds and analyzed with EMCALC 2013 version 3.0B software. Basic characteristics of subway operation, including alternative current(AC) or direct current(DC), voltage level, and opening year of the line were investigated. Real-time information during measurement, such as the time of departure, moving and arrival of trains, were also recorded. Results: The arithmetic mean(AM) and maximum(Max) intensity of ELF-MF were $0.62{\mu}T$ and $11.51{\mu}T$, respectively. Compared by region, the ELF-MF intensity measured inside cabin were the highest in the Seoul Metropolitan Area($AM=0.80{\mu}T$), followed by Busan($AM=0.30{\mu}T$), Daegu($AM=0.29{\mu}T$), Incheon($AM=0.14{\mu}T$), Gwangju($AM=0.04{\mu}T$) and Daejeon($AM=0.03{\mu}T$). The average ELF-MF level measured in AC trains($AM=1.36{\mu}T$) was also significantly higher than in DC trains($AM=0.28{\mu}T$). In terms of the opening year of the subway, trains opened before 1990($AM=0.85{\mu}T$) was the highest and the lowest was 2000-2009($AM=0.24{\mu}T$). Conclusions: The AC supply has the greatest influence on the generation of the ELF-MF intensity in subway cabins.