• Title/Summary/Keyword: Floor Temperature

Search Result 471, Processing Time 0.026 seconds

Establishment of Optimum Floor Surface Temperature Floor in Ondol Heating System (온수온돌 난방시 바닥면의 중성온도 설정에 관한 연구)

  • 공성훈
    • Journal of the Korean housing association
    • /
    • v.6 no.2
    • /
    • pp.51-55
    • /
    • 1995
  • This study presents a real neutral floor surface temperature in floor panel heating system(Ondol). The Ondol heating system can keep the constant temperature. However, the actual temperature when a person sits on a floor can be different from the surface temparature of a floor it self. The contents of this study are as follows : 1) measuring the spatial distributions of thermal conditions 2) the thermal sensation vote of residents is taken in order to investigate the relation between thermal condition and human thermal sensation in sedentary condition 3) estimating the neutral floor surface temperatures by measuring floor surface temperatures.

  • PDF

A Study on Application of Radiant Floor Heating in Large Space (대공간의 바닥 복사 난방 적용에 관한 연구)

  • Ahn, Min-Hee;Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.79-85
    • /
    • 2007
  • This paper addresses the indoor air quality when radiant floor heating is applied in large space. Radiant heat exchange between surfaces depends on the orientation and the temperature of the surfaces. Also, the temperature and the radiant characteristic of the wall and the roof that face the floor have great influence on the indoor air environment due to the largeness of the wall and the roof in large spaces. In this study, we simulate a test-cell(25X20X10) using a ies YE And using a CFD(microflo in VE), an indoor air environment was investigated to establish the optimum temperature of floor. At the first time of the heating, high floor temperature is demanded. At the middle of the heating, however, the temperature of the residential space was formed appropriately, although the temperature of the floor was set low.

A Study on the Mean Skin Temperature of the Man Who Stay in the Room (재실자의 평균피부온(平均皮膚溫)에 관한 연구)

  • Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.3 no.4
    • /
    • pp.307-317
    • /
    • 2000
  • The purpose of this study is to form a calculation formula of the mean skin temperature on the human body in a heated room by the use of floor heating system. Korean traditional floor heating system is a long way from being defunct. The floor heating systems based on hot water have been coming into wide use mainly in the apartment house. However, it is considered that the design process and evaluation method for the floor heating systems in the standpoint of human being are not established so far. In the floor heating systems, air temperature as well as floor temperature should be considered as physical factors which affect the sensation of human body. Furthermore, extremely few studies have been performed on the sitting with legs crossed posture sedentary which is the typical dwelling life style of residents from the ancient times in Korea, while a large number of studies on the influence of the floor heating systems on the human body in standing and sitting on a chair sedentary have been carried out. Especially, it is essential to elucidate how mean skin temperature on the human body is affected by thermal conduction in the contact area between the sitting with legs crossed posture sedentary human body and floor including thermal radiation due to the combination of air temperature and floor temperature, but the studies dealt with such issues have hardly been performed. Based on the above statements, the influence of the environment condition due to the combination of air temperature and floor temperature is discussed in the present investigation through theoretical of mean skin temperature on the human body in the floor heating systems.

  • PDF

A Study on Comparison of Capacity between Wet.Dry Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.567-570
    • /
    • 2009
  • The present study conducted comparative evaluation of wet dry floor heating systems using geothermal heat pump. Circulation hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler was used. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.89^{\circ}C$ for wet type and $32.66^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. In the results, for floor heating system using low temperature circulation water, wet type was not enough to meet stable and comfortable radiant floor heating due to low floor temperature and access time to indoor set temperature. While dry type was practicable for stable floor heating due to fast rise of indoor set temperature and comfortable floor temperature.

  • PDF

Comparison of the Preference for Floor Temperature between Young and Old People in a Winter Season (겨울철 젊은이와 노인의 선호 바닥온도 비교)

  • Ahn, Tae-Kyung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.2
    • /
    • pp.29-36
    • /
    • 2018
  • Even in modern times, we are accustomed to the lifestyle of floor heating system in which the floor is heated for warmth like Ondol, which is the traditional Korean heating system. So, this study was designed to understand the preferred floor temperature through the questionnaires targeting the local residents living in K region. This study would also find out the floor temperature which is preferred by young people and old people through the experiments. The findings are as follows; (1) the old people do not prefer the temperature higher than young people do. It was found that the old people prefer the floor temperature of $40^{\circ}C$ under the air temperature of $20^{\circ}C$ or the floor temperature of $41^{\circ}C$ under the air temperature of $20^{\circ}C$. (2) Both young people and old people tend to like the average skin temperature of $35.5^{\circ}C$. The skin temperature which both young and old people like was $35.2^{\circ}C$ under the air temperature of $24^{\circ}C$ and the skin temperature preferred by young people was $0.4^{\circ}C$ higher than that preferred by under the air temperature of $20^{\circ}C$ (p<0.01). (3) It was found in the questionnaires that the young people prefer the higher floor temperature in terms of age and that the people who get older in their 50s or higher tend to prefer the lower temperature.

A Study on the Korean Ondol-System Application in Apartment Houses (공동주택의 한국형 온돌시스템 적용에 관한 연구)

  • Ahn, Min-Hee;Choi, Chang-Ho;Yu, Ki-Hyung;Cho, Dong-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.860-865
    • /
    • 2006
  • The traditional Korean Ondol System that is a radiant floor heating system was made as warm floor and cool indoor temperature. Nowaday, Ondol is developed as the hydronic floor heating system. But unbalance of floor temperature and indoor temperature is occurred bocause strengthen thermal insulation and airtightness in building changes thermal performance. To solve these problems, we examine actual indoor environment of heating system methods in existing apartments and present the new method of floor heating system. The existing heating system made definite indoor temperatures but floor temperatures that is $22^{\circ}C-26^{\circ}C$ was maintained. To solve these problems, we adopted the differential heating system which made warm area and cool area. A differential heating system was made different pitches of heating pipe in single zone and ratio of warm area to cool area is 1 to 2. As a result of experiments, warm area temperature is $40.7^{\circ}C$, cool area temperature is $36.1^{\circ}C$. A difference of temperature between both area is 4K. A distribution of indoor vertical temperature is similar to both warm area and cool area.

  • PDF

Physiological Responses of the Human Body on a Change of the Floor Temperature in Indoor (인공기후실내의 바닥온도 변화에 의한 인체의 생리적 반응)

  • Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.1 no.1
    • /
    • pp.21-30
    • /
    • 1998
  • The purpose of this study is to clarify the floor temperature on the human body and to estimate thermal comfort zone in a heated room. In order to evaluate the effects of floor heating, a series of experiments were carried out using Korean subjects. The following experiments were conducted: 1) to obtain the effective radiation area and configuration factors of the person in the sitting posture on a floor to get the mean radiant temperature, 2) to measure contacted area of the person to the floor to calculate conduction heat rate, 3) to measure convective heat transfer coefficient of the body and 4) to know the thermal comfort zone of indoor environment heated by ON-DOL. Subjects were exposed to the following conditions: combinations of air temperature $20^{\circ}C$, $22.5^{\circ}C$, $25^{\circ}C$, and floor temperature $20^{\circ}C$, $22.5^{\circ}C$, $25^{\circ}C$, $27.5^{\circ}C$, $30^{\circ}C$, $32.5^{\circ}C$, $35^{\circ}C$, $37.5^{\circ}C$, $40^{\circ}C$ under still air and 50% relative humidity in the controllable artificial climate chamber. To evaluate the effect of heat conduction between the body and a floor modified mean skin temperature was defined. Weighting coefficient to calculate mean skin temperature were modified with the contacted area. The experiments revealed a positive correlation between the modified operative temperature and the modified mean skin temperature. The modified mean skin temperature can indicate the effect of heat conduction between body and a floor surface.

  • PDF

A Study on the Influence Affect of Thermal Sensation in Korean and Japanes to Sit Directly on a Heated Floor (바닥난방시 바닥 접촉면에 의한 한국인과 일본인의 온열감 반응에 대한 비교 연구)

  • Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.1
    • /
    • pp.81-89
    • /
    • 2002
  • The objective of this paper is to clarify the combined effect of heat conduction, air temperature and thermal radiation on the person seated on the floor under operation of floor heating system. Experiments were conducted for summer seasons under 8 kinds of condition: combinations of air temperature $20^{\circ}C$, $22.5^{\circ}C$ and floor temperature $20^{\circ}C$, $22.5^{\circ}C$, $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$ under still air. Japanese and Koreans were adopted as subjects. To evaluate the effect of conduction operative temperature modified by heat conduction was derived from the human heat balance equation. New weighting coefficients were estimated from the modified operative temperature and modified mean skin temperature. As for thermal sensation the modified operative temperature more significantly correlated to that sensation each heat transfer processes. As the floor temperature is higher, the human conduction heat gain from floor increase and the dry heat from the human body decrease.

  • PDF

An Experimental Study on Difference of Thermal Sensation by Radiant Floor Heating (바닥난방 복사열에 의한 온열감 차이에 대한 실험연구)

  • Choi, Yoon-Jung;Shim, Hyun-Suk;Jeong, Youn-Hong
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.65-71
    • /
    • 2007
  • The purpose of this study was to analyze the difference of thermal sensation by radiant floor heating as ecological design element. The experimental investigations were carried out in climate chamber, and subjects were 34 college-age females in good health. The experimental variable was radiant heat by floor heating, and experimental controlled conditions were indoor temperature, relative humidity, and air velocity in climate chamber and clothing value and activity of subjects. The results are as follows. (1) Indoor temperature($21{\pm}0.5^{\circ}C$) in climate chamber were maintained as controlling. Clothing values of the subjects were controlled as average 0.73 clo. In the floor heating-off, globe temperature was average $23.2^{\circ}C$(22.4~24.1), but in the floor heating-on, globe temperature was average $24.8^{\circ}C$(23.0~25.5). (2) In the floor heating-off, thermal sensation rating was average -1.03(slightly cool), in the floor heating-on, thermal sensation rating was average +1.03(slightly warm). (3) There were the differences of thermal sensation by radiant floor heating although indoor temperatures were maintained in an equal state. (4) The thermal sensation rating was tending upward according as the globe temperature was getting higher.

The comparison of thermal characteristics of new Han-ok floor heating for applying modern On-dol system (현대 온돌 시스템 적용을 위한 신한옥 바닥난방의 열적특성 비교)

  • Lee, Tai-Gang;Lee, Ju-Yeob;Song, Min-Jeong;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.61-69
    • /
    • 2013
  • The experiment on thermal characteristics of on-dol systems were carried out to apply to New Han-ok's heating system. Change of surface temperature varied with heating times, distribution of surface temperature, radiation property were surveid on four on-dol system in laboratory conditions. Followings are results. 1) "Hwang-to unit" was most favorable condition of the distribution of floor surface temperature. And the results from reaching time to thermal comfort temperature of on-dol system showed that "Hwang-to unit" was the most favorable to continuance of floor temperature. 2) There were a little difference in surface floor radiations of $30^{\circ}C$ for three wet on dol-systems. 3) It was suggested that "Hwang-to unit" is the most appropriate to floor heating system of new han-ok considering eco-friendship and continuance of floor temperature in intermittent heating condition.