• Title/Summary/Keyword: Floor Panel

Search Result 177, Processing Time 0.031 seconds

Shaking Table Experimental Study on 3-Dimensional Floor Isolation in Main Control Room of Nuclear Power Plant (원전 주제어실 3차원 층 지진격리시스템의 진동대 실험 연구)

  • Lee, Kyung-Jin;Ham, Kyung-Won;Suh, Yong-Pyo;Yoon, Hyun-Do
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.1
    • /
    • pp.57-66
    • /
    • 2008
  • An experimental study was performed to evaluate seismic reduction performance and applicability of 3-dimensional floor isolation system to the main control room of nuclear power plant. A friction pendulum system(FPS) and air spring were designed and fabricated for 3-dimensional floor isolation system. Two kind of the partial experimental model of a main control room attached to the FPS and air spring were tested on the shaking table. The experimental model consisted of a control panel, a $2.5m{\times}2.5m$ access floor, four FPS and air springs. The artificial time histories based on the vertical and horizontal floor response spectrums(OBE, SSE) of the main control room were used as the earthquake input signals in the test. Compared to non-isolated system, the seismic response of experimental models using 3-dimensional floor isolation system were shown considerable seismic reduction performance.

Characteristics of Temperature Distribution of Wall, Floor, Air and Hot Water by Burying the Excel Pipe on the Floor and Wall of a Container House (컨테이너하우스의 바닥과 벽면에 엑셀파이프 매설에 의한 벽면, 바닥, 공기, 온수의 온도분포 특성)

  • Cho, Dong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.2
    • /
    • pp.94-100
    • /
    • 2022
  • A study was conducted to significantly increase the heat transfer area by simultaneously burying the excel pipe in the floor and wall of a container house, thereby greatly reducing the initial heating time. In addition, a small hot water boiler suitable for the heating load of a small container house with a maximum area of 6 m2 was studied. A wall-mounted hot water boiler was developed as a result of the study. When a hot water boiler is installed outdoors for heating, heat radiation energy is lost in winter from the hot water boiler and hot water pipe due to the low temperature. We propose an approach through which the energy loss was greatly reduced and the temperature of hot water increased in proportion to the operating time. Moreover, as the mass flow rate of the hot water flowing inside the excel pipe increased, the temperature of the hot water decreased. The temperature of the wall and floor surfaces of the container house increased in proportion to the increase in the mass flow rate of hot water flowing inside the excel tube. Natural convection heat transfer was realized from the wall and floor surfaces of the container house, and the heat transfer area was increased by a factor of 3 with respect to heat transfer area limited to the floor by the existing hot water panel. As a result, the initial temperature increase rate was much higher because of the larger heat transfer area.

A Study Interior Noise Reduction of a Maglev Train at Low Speed (저속 주행시 자기부상열차의 실내소음저감에 관한 연구)

  • 김현실;김재승;강현주;김봉기;김상렬
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.7
    • /
    • pp.253-260
    • /
    • 2001
  • A Study of interior noise reduction in the magelv train is presented. Tarin speed of interest is low such that aero-dynamic noise is negligible and power supply system is a dominant noise source. Based on the measurements of interior noise and acceleration levels during running and zero speed conditions, dominant noise sources are identified. After spectra characteristics of noise sources are investigated several noise reducing methods are studied such as STL increasement of floor panels. sealing. and absorption treatment It is found that the most important noise sources are VVVF inverter and SLM in running condition, whereas air conditioner and DC/DC converter are dominant in zero speed. Sine the major noise sources are under the floor complete sealing and high STL of the floor panel are shown to be the most crucial factors in noise reduction After sound absorbing material, which is polyurethan foam of 50 mm thickness, is thickness, is attached to the downward side of the floor in addition to sealing treatment, the interior noise is reduced by 3~4 dB.

  • PDF

Acoustic Performance Improvement for Dome-typed Gymnastics Training Floor using Acoustic Simulation (음향 시뮬레이션을 이용한 돔형 체조연습장의 음향성능 개선)

  • Yun, Jae-Hyun;Jung, Chul-Woon;Kuk, Joung-Hun;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.696-700
    • /
    • 2007
  • In case of dome-typed gymnastics training floor, since its form takes shape of the focus of sound, in the occasion when the finishing-material was used with the sandwich panel that prominent in reflexibility, and because the reverberation of sound in indoor is too loud, a smooth practice and teaching is very difficult. As this indoor gymnastics training floor, standing at its character, is required simultaneously the idea communication between the player and the coach, and the acoustic capability regarding to the clearness of music, besides the sport activity, the method to minimize the acoustic defect should be urgently contrived from the stages of design and beginning of construction. On this viewpoint, after investigation on the confidence of the surveyed value and the estimated value using acoustic simulation, and use of the changed finish-material, this thesis intends to design the dome-typed gymnastics training floor that secured the optimized acoustic condition. It is also considered that such result of the study could be utilized as the useful data that enables to improve the retrenchment effect of the construction cost as well as the acoustic performance, by means of the prediction control on the acoustic problem from the stage of design, for the occasion when the similar indoor sport gymnasium is planning to build for the near future.

  • PDF

A Study on the Improvement of Easy Elevator Equipment (간이용 엘리베이터 장치 개선에 관한 연구)

  • Wee, Sung-Dong;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.82-88
    • /
    • 2001
  • Manufactured easy elevator can drives from the first floor to fifth floor as sequence control circuit in cause opening than existing equipment of experiment and practice, the structure of in the first implementation process are hand-worked control component with push-button, L/S and relay, it is structured a lamp to express that the door open and moving of cage by mechanical action of For/Rev motor-braker of which load. The second structure of implement process to control from the first floor to the fifth floor with the PLC elevator program can control by the sensor of hand-operated function of L/Sl~L/S5 in time that the S/Wl~S/W5 of PLC control panel operates to the For/Rev. The function of two kind process that an elevator is driven by PLC program and the sequence control relay circuit is a mechanical relay sequence control field and it is equipment apparatus of it to get appropriately the technology of For/Rev in that mechanical operating cause of a load using the PLC program. Also the wring circuit using a plug, dissembly. the circuit and the principle of component, and PLC program with the function test can be used the implementation field to the total technology theory about FA.

  • PDF

A Study on the Method of Estimating Optimum Supply Water Temperature Considering the Heating Load and the Heat Emission Performance of Radiant Floor Heating Panel (난방부하와 온수온돌의 방열성능을 고려한 적정 공급온수온도 산출방법에 관한 연구)

  • Choi, Jeong-Min;Lee, Kyu-Nam;Ryu, Seong-Ryong;Kim, Yong-Yee;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.795-800
    • /
    • 2006
  • A common approach to achieve better thermal comfort with hydronic radiant floor heating system is supply water temperature control. This is the control method through which supply water temperature is varied with outdoor temperature. In this study, a comprehensive, yet simple calculation method to find optimum supply water temperature is evaluated by combining heat loss from the building and heat emission from the hydronic radiant floor heating system. And then the control performance of suggested calculation method is confirmed through experiment. It is shown that indoor air temperature is stably maintained around the set point.

  • PDF

Investigation of the level difference of floor impact noises through the shape variation of EVA resilient materials with composite floor structure (EVA 완충재의 형상변환을 통한 복합구조의 바닥충격음 변이 조사)

  • Jakin Lee;Seung-Min Lee;Chan-Hoon Haan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.60-71
    • /
    • 2024
  • The present study aims to investigate the level difference of floor impact noises of composite floor structure using EVA resilient materials. In order to this, four different types of resilient materials were designed combining PET, PP sheet and EVA mount including Flat type, Deck type, Cavity type and Mount type. Totally 9 different samples were made for acoustic measurements which were carried out twice with bang-machine and impact ball as the heavy-weight floor impact noise sources. All the floor impact noise measurements were undertaken at the authentication institution. As a result, concerning Flat and Cavity types, it was found that 2 dB ~ 5 dB of heavy-weight floor impact noise was reduced supplementally when PET was added, while floor impact noise larger than 50 dB was acquired when single resilient material was used. Especially, most high performance was obtained for Mount type with 1st grade of light-weight floor impact noise and 2nd grade of heavy-weight floor impact noise. This is because of material property with low dense PET sound absorption materials which fill all around EVA mounts. Also, it was considered that this results are due to the sound impact absorption by the both EVA mounts and the air cavity between EVA mount and PP sheet. Also, it was found that at least 36 EVA mounts per 1m2 area of resilient panel make more noise reduction of heavy-weight floor impact noises.

Development of Housing Conceptual Framework through Changes in Korean Family Houses -Kitchen Lifespace(I)- (한국주거형태 변천과정에서 본 주거학의 생태학적 개념정립 제1부 부엌변천)

  • 윤복자
    • Journal of the Korean Home Economics Association
    • /
    • v.28 no.3
    • /
    • pp.67-85
    • /
    • 1990
  • The purpose of this study was (1) to investigate changes in house and kitchen forms and behaviors in the kitchen area of Korean family houses from the Yi-dynasty to the present, and (2) to develop a housing conceptual framework on the basis of the ecosystem approach through analysis of changes in Korean family houses. The documentary research method wad used fro this study. The major findings were that the traditional Korean houses were composed of separate buildings and had various floor levels with the maru(a wooden floor) as the center of the open plan. The introduction of foreign style house forms from the era of enlightenment, in the year 1876 to the Korean war in 1950 changed traditional Korean houses into Korean-western style houses. More recent increased population and urbanization accelerated to change from the traditional Korean house form to an apartment style. At the present time, however, many kinds of house forms, from a highly modernized style with convenient facilities to a primitive style, which cannot even meet the basis needs of daily life, coexist together. The Kitchens in traditional Korean houses had no plumbing, drainage, or work centers. They had simple adobe furnaces which were used for cooking and for heating the ondol, a kind of panel heated floor by which the heat and smoke run under the floor to the chimney. This made the kitchen floor level lower than the floors of other spaces. The residents entered the kitchen through the madang(atrium). The influence of the western style kitchen, the development of technology, and improvements of nation-wide economic status have made today's kitchen space covenient and hygienic. The floor level of the kitchen was raised to the same level of other spaces. Formerly the major function of the kitchen was raised to the same level of other spaces. Formerly the major function of the kitchen space was cooking and heating floors. This had changed, and the kitchen is now, the place for family and social interaction. A housing conceptual framework was developed on the basis of these findings.

  • PDF

Construction of Scheduling Support System for Panel Lines by Digital Manufacturing Simulation (디지털 생산 시뮬레이션 기반의 판넬라인 일정계획지원 시스템 구축)

  • Lee, Kwang-Kook;Choi, Dong-Hwan;Han, Sang-Dong;Park, Ju-Young;Shin, Jong-Gye
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.2 s.146
    • /
    • pp.228-235
    • /
    • 2006
  • Nowadays, digital manufacturing has been known to be very effective method in manufacturing fields. It is aimed to estimate process time, to improve operation efficiency, and to prevent bottleneck processes in advance of real manufacturing. This paper addresses a scheduling support system for panel hues in a shipyard through digital manufacturing simulation. The proposed system supports operators to make better decisions on the shop-floor scheduling in panel lines. It ,would provide a complete schedule that is at least as good as any schedule currently obtained. Furthermore, it can evaluate the operator's schedule by simulating it with 3-dimensional models before the work orders and schedules are released.

Study on Structural Reliability Assessment of a Partition Panel Made of a CFRP(Carbon Fiber Reinforced Plastic) (탄소복합재 부품 파티션패널의 구조 강성/강도 신뢰성 평가에 관한 연구)

  • Lee, Jaejin;Mun, Jihun;Yoon, Wonho;Kang, Dakyung;Ahn, Minsu;Roh, Hyungjin;Kang, Jiheon;Lee, Jaewook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.68-74
    • /
    • 2019
  • In the case of a partition panel for a vehicle, it is used as a vehicle chassis component that serves to distinguish the indoor and outdoor spaces of a vehicle and is mounted on a backrest portion of the vehicle's back seat to ensure the convenience of passengers by connecting the floor and the side of the vehicle. Because it is a relatively large-sized plate material among automobile chassis parts except the moving parts and non-ferrous materials can be applied, it is considered as a part having a large light-weight effect. However, the partition panel is one of the vehicle parts that must satisfy the light-weight effect as well as various structural reliability, such as torsional rigidity, vibration, and impact characteristics, for securing the running stability of the vehicle when driving at the same time. So, In this study, the possibility of replacing the aluminum partition panel as CFRP(Carbon Fiber Reinforced Plastic) partition panel is evaluated through comparing the two partition panels by using the structural reliability(stiffness/strength analysis), vibration analysis, impact analysis.