• Title/Summary/Keyword: Floor Area

Search Result 1,188, Processing Time 0.029 seconds

A Study on the Location and Area Composition of the Operation Department in Regional Public Hospitals - Focused on Net Floor Area (지방의료원 수술부 배치 및 규모에 관한 연구 - 순면적을 중심으로)

  • Yun, Woo Yong;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.4
    • /
    • pp.93-104
    • /
    • 2019
  • Purpose: To establish the building guidelines and to analyze the function of Regional Public Hospitals, the survey was conducted primarily on the current status focusing on the location and relationship of the department, area composition ratio, area per bed, and area per operating room. Methods: The research methods of this paper are as follows. 1) A literature survey on the function of the operating and related departments, 2) A drawing analysis for spatial composition and net area calculation. Results: The area of the Operation Department in the Regional Public Hospitals with 200 to 300 beds are as follows. Area ratio: 3.35%, area per Bed: 2.53㎡/bed, the number of beds per operating room: 64.37bed, area per operating room: 146.46㎡/n, area per operating room by plan type: integration corridor 133.84㎡/n, separation corridor 184.82㎡/n. Implications: This paper analyzed data on the current state of Operation Departments for setting up the function and role for the Regional Public Hospital. In the future, it is also required to provide size that takes into account user behavior and the user's psychological aspect in order to suggest appropriate area.

A Study on the Floor Plan Characteristics of Component Schools in Small Schools Complexes -by Analyzing Spatial Structures of School Facilities in Foreign Countries- (집합형 소규모 학교의 단위학교 평면구성 특성에 관한 연구 -외국학교 사례의 공간구성 분석을 통하여-)

  • Kweon, Ji-Hoon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.14 no.4
    • /
    • pp.86-95
    • /
    • 2007
  • This study clarifies the theoretical background and the floor plan characteristics of component schools in Small Schools Complexes. The recent researches have proved the enhancement of students' social relationship and school security in the new school environment. The findings fur the characteristics by analyzing the component schools from six school complexes follow: (1) Students can access their classrooms in component schools through main entrances, shared corridors and private corridors. (2) Teachers' area is segregated from students' area, which does not encourage the social relationship between teachers and students. (3) Some of special classrooms, which are generally considered as shared facilities in a Small Schools Complex, are planned within component schools for accommodating specialized educational programs. (4) A component school occupying multiple floors reduces Intelligibility of space and chances of users' visual contact to colleagues. Finally, this study proposed the alternative floor planning directions in order to improve users' social relationship in a component school.

Dementia Units' Architectural Features in the Metropolitan Area (수도권 치매요양시설의 건축적 특성)

  • Cho Young-Hang;Lyou Joung-Woo
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.15-24
    • /
    • 2006
  • The purpose of this study is to unveil the characteristics of residential space organizations in dementia units. Observation, interview, and drawing analysis of the sample units were used to collect the data for new dementia unit plans. The findings revealed the lack of minimum requirement of residential spaces per person in some sample units, the necessity of consideration of group units, and the change of units based plans to each floor based plans. However, insufficient recreation rooms and the lack of caregivers' resting spaces in the sample units were uncovered. Thus, various recreation rooms such as a reading room, flower room, pottery room, bakery room, or game room should be provided in the sample units. The conclusion is that asylum oriented residential types should be changed to each floor based units having privacy and high satisfaction of residential life. The study of floor oriented residential units focusing on minimum spaces of the floor, space numbers, number of elderly persons on each floor should be studied in the near future.

Strength Measurements of Slim Floor Composite Beams used Perforated Square Shape Steel Pipe (천공된 각형강관을 이용한 슬림플로어 합성보의 내력실험)

  • Kim, Dong-Yeon;Rhim, Hong-Chul;Park, Sung-Woon;Kim, Do-Kyun;Lyum, Seung-Il;Park, Dae-Won
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.189-190
    • /
    • 2015
  • Slim Floor construction method has to increase the available surface area thereby reducing the depth beams and slab. In addition, In this study compostie beam assembly of plates, square-shape steel pipe and deck plate. So workabiltiy is superior to the upper concrete possible without formwork. In the present study is strength test in progress in development slim floor composite beam used plate and perforated square shape steel pipe and obtained anlysis and conclustion of the experimental results.

  • PDF

The Preliminary Research on the Relationship between Carbon Emissions and Typical Floor Design of High-Rise Office Buildings in Shanghai

  • Zhixin, Dong;Yi, Chen
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.2
    • /
    • pp.153-159
    • /
    • 2018
  • The greenhouse effect caused by human activities is becoming increasingly serious. The building industry, which is directly related with carbon emissions, has the responsibility and potentiality to reduce carbon emissions. Recently, Chinese and foreign academics have achieved some research results with respect to building carbon emissions. This paper tries to examine these issues in the context of climate conditions in the Shanghai area. Based on the typical floor plans of high-rise office buildings, analysis was performed via software simulation and data analysis; the paper explores the relationship between different design methods of typical floor plans and carbon emissions. The objective is to deliver results beneficial to typical floor-design methods with respect to the reduction of carbon emissions, so as to provide a reference for architects.

Which is Your Favorite?: The Impact of Robot's Height on Consumer's Acceptance of a Telepresence Robot

  • Choi, Jung Ju;Kwak, Sonya S.
    • Design Convergence Study
    • /
    • v.15 no.4
    • /
    • pp.59-70
    • /
    • 2016
  • Due to the newly emerging market for telepresence robots and the research in the area, designers and developers lack guidelines for specifying the physical characteristics of telepresence robots. On the basis of the previous literature, we attempted to make a distinction between two robot height approaches for telepresence robot designs: floor- versus desk-based robot designs. This research investigated the effects of these robot height approaches on consumer acceptance. We predicted that there would be difference between floor-based robots and desk-based robots regarding consumers' evaluation of and intent to purchase social robots. A study using two types of robots was conducted with sixty university students. The results showed that participants perceived desk-based robots as more useful than floor-based robots. In addition, the participants evaluated desk-based robots more positively than floor-based robots. Purchase intention and willingness to pay also showed similar results as evaluation. The implications for the design of telepresence robots in terms of increasing acceptance of robots are discussed in detail.

A Study on Upper-Class House in North Kyeung-Buk Region (경북북부지역의 상류주택에 관한 조사연구)

  • 백영흠
    • Journal of the Korean housing association
    • /
    • v.5 no.1
    • /
    • pp.59-69
    • /
    • 1994
  • This paper was made to examine floor plan and block plan of traditional upper-class houses in the north Kyeungsangbukdo region with consideration into city and country each. The results of this study were as following; First, Munkyung area is latitudinally located in northern area along with the Yechon and Andong. However, Munkyung area has open plot system while Yechon and Andong has not. It is because even if Munkyung area is located in the western of Nak-Dong river and belongs to the northern region, it has belonged to the cultural area which is developed around Sangju area. Second, Youngduk area belongs to the east-coast but it had frequent cultural exchange and marriage with Andong which is located on the road along with Tae-Baek Mountain. Due to the cultural exchange, their housing type is very similar to those of Andong which is close plot plan of "ㅁ" type. Therefore, even if Youngduk is located in the east-coast area, it should belong to the cultural background of Andong area. Regionally, the culture of Kyongsangbukdo has been divided into northern area, southern area, and east-coast area. But, the findings of this study indicate that the analysis of location and floor plan of housing should not be based on the natural environment oand geographic characteristics. Hence, it should be based on the all aspects of environment, including social and cultural nature to find more reliable and accurate results.e results.

  • PDF

A Study on the Mean Skin Temperature of the Man Who Stay in the Room (재실자의 평균피부온(平均皮膚溫)에 관한 연구)

  • Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.3 no.4
    • /
    • pp.307-317
    • /
    • 2000
  • The purpose of this study is to form a calculation formula of the mean skin temperature on the human body in a heated room by the use of floor heating system. Korean traditional floor heating system is a long way from being defunct. The floor heating systems based on hot water have been coming into wide use mainly in the apartment house. However, it is considered that the design process and evaluation method for the floor heating systems in the standpoint of human being are not established so far. In the floor heating systems, air temperature as well as floor temperature should be considered as physical factors which affect the sensation of human body. Furthermore, extremely few studies have been performed on the sitting with legs crossed posture sedentary which is the typical dwelling life style of residents from the ancient times in Korea, while a large number of studies on the influence of the floor heating systems on the human body in standing and sitting on a chair sedentary have been carried out. Especially, it is essential to elucidate how mean skin temperature on the human body is affected by thermal conduction in the contact area between the sitting with legs crossed posture sedentary human body and floor including thermal radiation due to the combination of air temperature and floor temperature, but the studies dealt with such issues have hardly been performed. Based on the above statements, the influence of the environment condition due to the combination of air temperature and floor temperature is discussed in the present investigation through theoretical of mean skin temperature on the human body in the floor heating systems.

  • PDF

Study on the Spatial Standard for Reading Rooms in University Libraries (대학도서관 열람실 공간기준에 관한 연구)

  • Lim, Ho-Kyun
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.5
    • /
    • pp.140-147
    • /
    • 2016
  • This research aims to establish the size standard of university library's user space, and present the standard and method to calculate total area required in the planning of new building construction and remodeling. Nine university libraries newly constructed or remodeled since 2000 were selected among the libraries of large scale universities with more than 10,000 enrolled students as the target libraries in this research. The target libraries were classified into A group (five cases partially remodeled) and B group (four cases newly constructed or fully remodeled) on the basis of the change of times. A university library can be divided into three spaces (user space, administration space and public space). This research classified the reading room in the user space into bookshelf zone, reading zone, information/office zone and hall/other zone, and analyzed area ratio according to each zone. B group's bookshelf zone decreased 12% more than A group, and B group's reading zone increased 10% more than A group. However, there was no big change in the area ratio of information/office zone and hall/other zone. This can be interpreted that university library changes from book and archive preservation-oriented space to user-oriented space. This research presented a proper reading room area calculation method, based on the capacity of books, by reflecting such a change. Each zone's standard was set up through classification of domestic and international standards, based on which, the calculation method of university library's total floor area required was presented. The reason why there was difference in university library's total floor area required according to domestic standard and international standard was that the number of enrolled students per seat in the reading room was different. The area calculation methods presented in this research can be utilized as useful data upon planning university library construction or remodeling.