Laterally-Averaged Two-Dimensional Hydrodynamic and Turbidity Modeling for the Downstream of Yongdam Dam (용담댐 하류하천의 횡방향 평균 2차원 수리·탁수모델링)

  • Kim, Yu Kyung;Chung, Se Woong
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.710-718
    • /
    • 2011
  • An integrated water quality management of reservoir and river would be required when the quality of downstream river water is affected by the discharge of upstream dam. In particular, for the control of downstream turbidity during flood events, the integrated modeling of reservoir and river is effective approach. This work was aimed to develop a laterally-averaged two-dimensional hydrodynamic and water quality model (CE-QUAL-W2), by which water quality can be predicted in the downstream of Yongdam dam in conjunction with the reservoir model, and to validate the model under two different hydrological conditions; wet year (2005) and drought year (2010). The model results clearly showed that the simulated data regarding water elevation and suspended solid (SS) concentration are well corresponded with the measured data. In addition, the variation of SS concentration as a function of time was effectively simulated along the river stations with the developed model. Consequently, the developed model can be effectively applied for the integrated water quality management of Yongdam dam and downstream river.

A Study on the Appropriate exposure time for Flood discharge measurement of Surface velocity radar (전자파표면유속계의 홍수량 측정을 위한 적정 노출시간 검토)

  • Tae Hee Lee;Jong Wan Kang;Jae Hoon Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.298-298
    • /
    • 2023
  • 전자파표면유속계는 홍수량 측정을 위해 사용되는 비접촉식 유속계로, 전자파를 발사한 후 수표면에 반사되는 전자파의 도플러 효과를 이용하여 표면유속을 측정하는 기기이다. 국제적으로 1980년대부터 홍수량 측정의 어려움을 극복하기 위해 하천 유량측정 업무에 활용하였다. 전자파표면유속계를 이용하여 정확한 표면유속을 측정하기 위해서는 측정 위치, 방향, 노출시간, 환경 등을 고려해야 한다. 여기서 노출시간은 표면유속 측정을 위해 전자파를 흐름 상태의 수표면에 노출시키는 시간을 의미한다. 특히, 노출시간은 유속에 따라 결정되며, 빠른 유속일수록 측정에 필요한 노출시간이 짧아진다. 그러나 노출시간이 너무 짧으면 측정 유속값이 부정확하거나 불안정해질 수 있으며, 반대로 너무 길면 수위 등 측정조건이 변화하여 측정값이 부정확해질 수 있다. 따라서 홍수량 측정을 위해 전자파표면유속계의 표면유속 측정의 적정한 노출시간을 설정해야 한다. 본 연구에서는 전자파표면유속계의 적정한 노출시간 검토를 위해 안동하천실험센터에서, 표면유속 최대 4.92 m/s에서 최소 0.457 m/s 범위의 19개 유속 조건에서 노출시간을 10초에서 40초까지 5초 간격으로 변화시키며 표면유속을 측정하였다. 현재 국내외 가이드라인에서 권고하고 있는 노출시간 30초에서 측정된 표면유속과 각 노출시간에서 측정된 표면유속의 정확도 검증을 통해 유사한 값을 가지는 표면유속을 검토하여, 수위변화에 대응하여 홍수량 측정을 위한 최소 노출시간을 검토하였다.

  • PDF

A Study on Travelling Characteristics and Choice of Proper Location of Dam Discharge Alarm Broadcasting (댐 방류 경보방송의 전달 특성 및 적정 위치 선정에 관한 연구)

  • Kim, Dae-Goon;Kim, Jae-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.8
    • /
    • pp.635-640
    • /
    • 2009
  • After 1960s, in accordance with getting bigger in changing range of annual rain precipitation, those dams were built in order to prevent any drought and flood through the regulation of flux. In case of such dam, when it reaches to some definite pondage, for its regulation of water volume, numerous volume of water in the reservoir should be discharged by opening the floodgate, at this time a severe damage can be occurred to those lives and properties of the residents and tourists at the river or riverside. Accordingly, despite the sounding alarm broadcasting for prevention and notice such damage could be clearly travelled to those people without influence by the discharging noise or other neighboring environmental factor, since it was only empirically installed without any peculiar research until now, the alarm broadcasting could not effectively travel, and the travelling distance also could not known correctly. On such point of view, this Study has ever grasped the characteristics by frequencies and its sound pressure level about the discharge noise and the alarm broadcasting of Daechung Dam, one of multipurpose dams through the measurement and analysis by distances, and based on this, also has ever presupposed the proper location of additional alarm broadcasting spot using a simulation program named Cadna-A.

Analysis of Effects on Soil Erosion Reduction of Various Best Management Practices at Watershed Scale (최적관리기법에 따른 토양유실 저감 효과 유역단위 분석)

  • Lee, Dong Jun;Lee, Ji Min;Kum, Donghyuk;Park, Youn Shik;Jung, Younghun;Shin, Yongchul;Jeong, Gyo-Cheol;Lee, Byeong Cheol;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.638-646
    • /
    • 2014
  • Soil erosion from agricultural fields leads to various environmental problems weakening the capabilities of flood control and ecosystem in water bodies. Regarding these problems, Ministry of Environment of South-Korea prepared various structural and non-structural best management practices (BMPs) to control soil erosion. However, a lot of efforts are required to monitor and develop BMPs. Thus, modeling techniques have been developed and utilized for these issues. This study estimated the effectiveness of BMPs which are a vegetation mat with infiltration roll and Roll type vegetation channel using Soil and Water Assessment Tool (SWAT) model through the adjustment of the conservation practice factors, P factors, for Universal Soil Loss Equation which were calculated by monitoring data collected at the segment plots. Each BMP was applied to the areas with slopes ranged from 7% to 13% in the Haeanmyeon watershed. As a result of simulation, the vegetation mat with infiltration roll and Roll type vegetation channel showed 55% and 59% efficiency of soil erosion reduction, respectively. Also, Vegetation mat with infiltration roll and Roll type vegetation channel showed each 11.2% and 11.8% efficiency in reduction of sediment discharge. These roll type vegetation channel showed greater efficiency of soil erosion reduction and sediment discharge. Based on these results, if roll type vegetation channel is widely used in agricultural fields, reduction of soil erosion and sediment discharge of greater efficiency would be expected.

Hydraulic & Hydrologic Design Criteria for an Emergency Discharge of Reservoir (I) (댐 비상방류 설계기준 선정을 위한 수리수문학적 검토(I))

  • Son, Kwang Ik;Yi, Jaeeung
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.3
    • /
    • pp.149-158
    • /
    • 2015
  • It is well known that emergency outlet works have to be provided for the safety of dams. However, concept of emergency outlet works did not applied for the design of the most dams in Korea. Korean design standard for low-level outlet works does not provide enough design criteria which could be used in design of emergency outlet works. In this research, as-built status and hydraulic design criteria of outlet works, such as drawdown rate or hydraulic pressure due to the impounded water depth, were examined. Another relationship between drawdown rate and the dam slope stability was also examined with SEEP model. It was found that 25% reduction of impounded water depth decreases the pressure forces about 50%. Therefore, outlet works should be designed to drawdown properly at the beginning of the emergency. Seepage analysis of dam bodies showed that most of Korean dams could safely stand for 1m/day drawdown rate. Higher drawdown rate could result high discharge so the drawdown rate must be related with the flood risk of downstream. Finally, multi-stage design was recommended that faster discharge for the initial 25% of water depth in 7-10 days than the rest of it in 1-2 months.

Formation and Evolution of Turbidity Maximum in thd Keum Estuary, West Coast of Korea (금강 하구에서의 최대혼탁수 형성 및 변화에 대한 연구)

  • 이창복;김태인
    • 한국해양학회지
    • /
    • v.22 no.2
    • /
    • pp.105-118
    • /
    • 1987
  • A series of anchor stations were occupied along the Keum EAstuary during six different periods of tidal and fluvial regimes. The results clearly show that the formation and evolution of the turbidity maximum play an important role in the sedimentary processes in this environment. The turbidity maximum in the Keum Estuary is primarily related to the tidal range at the mouth and is caused by the resuspension of bottom sediments. In this estuary, the turbidity maximum is not a permanent feature and shows semidiurnal, fortnightly and seasonal variations. Repetition of deposition and resuspension of fine sediments occur in response to the variation in current velocity associated with semidiurnal tidal cycles. The core of turbidity maximum shifts landward or seaward accordion to the flood-ebb succession. The turbidity maximum also shows a fortnightly variation in response to the spring-neap cycles. Thus, the turbidity maximum degenerates during neap-tide and regenerates during spring-tide. The freshwater discharge is also an important factor in the formation and destruction of the turbidity maximum. The increase in freshwater discharge in rainy season can create an ebb-dominant current pattern which enhances the seaward transport of suspended sediments, resulting in the shortening of residence time of suspended materials in the estuary. Thus, under this high discharge condition, the turbidity maximum exists only during spring-tide and starts to disappear as the tidal amplitude decreases.

  • PDF

Estimation of stream flow discharge using the satellite synthetic aperture radar images at the mid to small size streams (합성개구레이더 인공위성 영상을 활용한 중소규모 하천에서의 유량 추정)

  • Seo, Minji;Kim, Dongkyun;Ahmad, Waqas;Cha, Jun-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.12
    • /
    • pp.1181-1194
    • /
    • 2018
  • This study suggests a novel approach of estimating stream flow discharge using the Synthetic Aperture Radar (SAR) images taken from 2015 to 2017 by European Space Agency Sentinel-1 satellite. Fifteen small to medium sized rivers in the Han River basin were selected as study area, and the SAR satellite images and flow data from water level and flow observation system operated by the Korea Institute of Hydrological Survey were used for model construction. First, we apply the histogram matching technique to 12 SAR images that have undergone various preprocessing processes for error correction to make the brightness distribution of the images the same. Then, the flow estimation model was constructed by deriving the relationship between the area of the stream water body extracted using the threshold classification method and the in-situ flow data. As a result, we could construct a power function type flow estimation model at the fourteen study areas except for one station. The minimum, the mean, and the maximum coefficient of determination ($R^2$) of the models of at fourteen study areas were 0.30, 0.80, and 0.99, respectively.

A Case Study for the Determination of Time Distribution of Frequency Based Rainfall (확률강우의 적정시간분포 결정에 관한 연구)

  • Lee, Jeong Ki;Kim, Hung Soo;Kang, In Joo
    • Journal of Wetlands Research
    • /
    • v.6 no.3
    • /
    • pp.71-81
    • /
    • 2004
  • In recent, the heavy rainfall is frequently occurred and the damage tends to be increased. So, more careful hydrologic analysis is required for the designs of the hydraulic or disaster prevention structures. The time distribution of a rainfall is one of the important factors for the estimation of peak flow in hydrologic and hydraulic designs. This study is to suggest a methodology for the estimation of a rainfall time distribution which can reflect the meteorologic and topographical characteristics of Daejeon area. We collect the 34 years' rainfall data recorded in the range of 1969 to 2002 for Daejeon area and we performed the rainfall analysis with the data in between May and October of each year. According to the Huff method, the collected data corresponds to the first quartile which the rainfall is concentrated in the primary stage but the suggested method shows the different rainfall distribution with the Huff method in time. The reason is that the Huff method determines the quartile in each storm event while the suggested one determines it by estimating the dimensionless distribution of rainfall in duration after the accumulation of rainfall in time. The rainfall distributions estimated by two methodologies were applied to the Gabcheon basin in Daejeon area for the estimation of flood flow. Here we use the SCS method for the effective rainfall and unit hydrograph for the flood discharge. As the results, the peak flow for 24-hour of 100-year frequency was estimated as a $3421.20m^3/sec$ by the Huff method and $3493.38m^3/sec$ by the suggested one. We can see the difference of $72.18m^3/sec$ in between two methods and thus we may carefully determine the rainfall time distribution and compute the effective rainfall for the estimation of the peak flow.

  • PDF

Spatiotemporal Variations of Seawater Quality due to the Inflow of Discharge from Nakdong River Barrage (낙동강 하구둑 방류수에 의한 하구역 수질의 시공간적 변화)

  • Yoon, H.S.;Park, S.;Lee, I.C.;Kim, H.T.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.2
    • /
    • pp.78-85
    • /
    • 2008
  • We estimated the pollutant loads for the last 3 years based on the daily discharge at the Nakdong River dam(barrage) and spatiotemporal characteristics of seawater quality in the Nakdong river estuary to investigate the correlation between the pollutant load inflow rate and seawater quality. The main results from this research are summarized as follows. (1) The total discharge at the Nakdong River dam dam the last 11 years has been $224,576.8{\times}10^6m^3/day$. The discharge figures show that the maximum discharge occurs in August with $52,634.2{\times}10^6 m^3/day$ (23.4% of the year's volume), followed by July and Sep. in that order with 23.1 and 17%, respectively. (2) The pollutant load influx from the Nakdong River dam was composed of 307,591.3COD-kg/day, 128.746.1 TN-kg/day, and 107,625.8 TP-kg/day. (3) The surface temperature in the Nakdong River estuary was about $2.137^{\circ}C$ higher than that of the lower layer. The salinity of the lower layer was 2.209%o higher than that of the ocean surface. The salinity of the ocean surface decreased by up to 19.593%o due to the inflow of the discharge at the Nakdong River dam. (4) DO, COD, TN, and SS concentration levels tended to be higher at the ocean surface than in lower layers, whereas the reverse was true for TP. (5) The water mass at the ocean's surface and in the lower layers during the drought and flood seasons tended to be separated by the difference in densities due to the freshwater inflow.

  • PDF

Derivation of the Synthetic Unit Hydrograph Based on the Watershed Characteristics (유역특성에 의한 합성단위도의 유도에 관한 연구)

  • 서승덕
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.1
    • /
    • pp.3642-3654
    • /
    • 1975
  • The purpose of this thesis is to derive a unit hydrograph which may be applied to the ungaged watershed area from the relations between directly measurable unitgraph properties such as peak discharge(qp), time to peak discharge (Tp), and lag time (Lg) and watershed characteristics such as river length(L) from the given station to the upstream limits of the watershed area in km, river length from station to centroid of gravity of the watershed area in km (Lca), and main stream slope in meter per km (S). Other procedure based on routing a time-area diagram through catchment storage named Instantaneous Unit Hydrograph(IUH). Dimensionless unitgraph also analysed in brief. The basic data (1969 to 1973) used in these studies are 9 recording level gages and rating curves, 41 rain gages and pluviographs, and 40 observed unitgraphs through the 9 sub watersheds in Nak Oong River basin. The results summarized in these studies are as follows; 1. Time in hour from start of rise to peak rate (Tp) generally occured at the position of 0.3Tb (time base of hydrograph) with some indication of higher values for larger watershed. The base flow is comparelatively higher than the other small watershed area. 2. Te losses from rainfall were divided into initial loss and continuing loss. Initial loss may be defined as that portion of storm rainfall which is intercepted by vegetation, held in deppression storage or infiltrated at a high rate early in the storm and continuing loss is defined as the loss which continues at a constant rate throughout the duration of the storm after the initial loss has been satisfied. Tis continuing loss approximates the nearly constant rate of infiltration (${\Phi}$-index method). The loss rate from this analysis was estimated 50 Per cent to the rainfall excess approximately during the surface runoff occured. 3. Stream slope seems approximate, as is usual, to consider the mainstreamonly, not giving any specific consideration to tributary. It is desirable to develop a single measure of slope that is representative of the who1e stream. The mean slope of channel increment in 1 meter per 200 meters and 1 meter per 1400 meters were defined at Gazang and Jindong respectively. It is considered that the slopes are low slightly in the light of other river studies. Flood concentration rate might slightly be low in the Nak Dong river basin. 4. It found that the watershed lag (Lg, hrs) could be expressed by Lg=0.253 (L.Lca)0.4171 The product L.Lca is a measure of the size and shape of the watershed. For the logarithms, the correlation coefficient for Lg was 0.97 which defined that Lg is closely related with the watershed characteristics, L and Lca. 5. Expression for basin might be expected to take form containing theslope as {{{{ { L}_{g }=0.545 {( { L. { L}_{ca } } over { SQRT {s} } ) }^{0.346 } }}}} For the logarithms, the correlation coefficient for Lg was 0.97 which defined that Lg is closely related with the basin characteristics too. It should be needed to take care of analysis which relating to the mean slopes 6. Peak discharge per unit area of unitgraph for standard duration tr, ㎥/sec/$\textrm{km}^2$, was given by qp=10-0.52-0.0184Lg with a indication of lower values for watershed contrary to the higher lag time. For the logarithms, the correlation coefficient qp was 0.998 which defined high sign ificance. The peak discharge of the unitgraph for an area could therefore be expected to take the from Qp=qp. A(㎥/sec). 7. Using the unitgraph parameter Lg, the base length of the unitgraph, in days, was adopted as {{{{ {T}_{b } =0.73+2.073( { { L}_{g } } over {24 } )}}}} with high significant correlation coefficient, 0.92. The constant of the above equation are fixed by the procedure used to separate base flow from direct runoff. 8. The width W75 of the unitgraph at discharge equal to 75 per cent of the peak discharge, in hours and the width W50 at discharge equal to 50 Per cent of the peak discharge in hours, can be estimated from {{{{ { W}_{75 }= { 1.61} over { { q}_{b } ^{1.05 } } }}}} and {{{{ { W}_{50 }= { 2.5} over { { q}_{b } ^{1.05 } } }}}} respectively. This provides supplementary guide for sketching the unitgraph. 9. Above equations define the three factors necessary to construct the unitgraph for duration tr. For the duration tR, the lag is LgR=Lg+0.2(tR-tr) and this modified lag, LgRis used in qp and Tb It the tr happens to be equal to or close to tR, further assume qpR=qp. 10. Triangular hydrograph is a dimensionless unitgraph prepared from the 40 unitgraphs. The equation is shown as {{{{ { q}_{p } = { K.A.Q} over { { T}_{p } } }}}} or {{{{ { q}_{p } = { 0.21A.Q} over { { T}_{p } } }}}} The constant 0.21 is defined to Nak Dong River basin. 11. The base length of the time-area diagram for the IUH routing is {{{{C=0.9 {( { L. { L}_{ca } } over { SQRT { s} } ) }^{1/3 } }}}}. Correlation coefficient for C was 0.983 which defined a high significance. The base length of the T-AD was set to equal the time from the midpoint of rain fall excess to the point of contraflexure. The constant K, derived in this studies is K=8.32+0.0213 {{{{ { L} over { SQRT { s} } }}}} with correlation coefficient, 0.964. 12. In the light of the results analysed in these studies, average errors in the peak discharge of the Synthetic unitgraph, Triangular unitgraph, and IUH were estimated as 2.2, 7.7 and 6.4 per cent respectively to the peak of observed average unitgraph. Each ordinate of the Synthetic unitgraph was approached closely to the observed one.

  • PDF