• Title/Summary/Keyword: Flicker Test

Search Result 41, Processing Time 0.021 seconds

Subjective Symptoms and Flicker Test Vlaues in Relation to Chronic Low Dose Organic Solvent Exposure (저농도 만성적인 유기용제 폭로시 자각증상과 Flicker 검사치와의 연관성)

  • Son, Myung-Ho;Sohn, Seok-Joon;Choi, Jin-Su
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.557-567
    • /
    • 1994
  • This study was conducted to examine the effect of chronic low dose organic solvent exposures in the industries towards then neurobehavioral functions of workers. Subjective symptoms on neurobehavioral function as well as a visual reaction time test (Flicker test) were administered to 94 exposed and 162 unexposed workers in a oil refinery and some other auto-repair shops. The results obtained were as follows : 1. Symptom complaints were higher and Flicker test values were lower in exposed workers than in unexposed workers. 2. Flicker valus were Inversely correlated with urinary Hippuric acid concentration in exposed workers(r=-0.26, p<0.05). 3. Flicker valus were inversely co..elated with Subjective symptom score(r=-0.15, p<0.05). Low Flicker value were also related with some subjetive symptoms such as 'Dimmed vision', 'Nightmare', 'Weakness on extrimity' in workers as a whole. While symptoms of 'Dimmed vision ', 'Nightmare' only observed among exposed workers.

  • PDF

Implementation and Performance Evaluation of Digital Flickermeter Algorithm According to IEC61000-4-15 Edition 2 for Korean Distribution Power System (국내 계통 특성을 고려한 IEC61000-4-15 Edition 2 기반의 디지털 플리커 미터 알고리즘 구현 및 평가)

  • Shin, Hoon-Chul;Han, Su-Kyoung;Park, Sang-Ho;Kim, Kern-Joong;Cho, Soo-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1017-1024
    • /
    • 2017
  • The International Electrotechnical Commission(IEC) 61000-4-15 is a standard proposing techniques for a flicker meter test and measurement method. The IEC61000-4-15 ed1 announced in 1997 was not include tests for accurate verification. Also it was not explained flicker meter algorithm that can be directly applied to the other power systems. But the new edition of IEC61000-4-15 ed2 prescribes a variety of tests for verify flicker meter algorithm and it explains 'correction factor' used for measuring flicker in other power systems. It can measure flicker severity in 220V system by multiplying correction factor to the measured values with the 230V algorithm. This paper compared the method of measuring flicker severity in korea power system using the correction factor and the modified weighting filter, after verifying of digital flicker meter algorithm created by using matlab based on IEC61000-4-15 ed2.

The Determination of Reference Impedance on 1P2W Low Voltage System in Korea (국내 단상2선식 저압 배전계통 기준임피던스 선정에 관한 연구)

  • Kang, Moon-Ho;Song, Yang-Hyao;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.35-39
    • /
    • 2007
  • Home appliances, like air-conditionals, washers, refrigerators, etc., can cause voltage fluctuations and light flicker. A standardized flicker test has been established in Europe(IEC 61000-3-3, IEC 61000-3-11). The supply impedance of power supply system varies from plate to place, and for the flicker test in KOREA, the appliance manufacturers do need standardized impedance like the one indicated in IEC 61000-3-3 for 230[V]/50[Hz]. Without it, the same appliance will have different flicker level at different places. For appliance manufacturers, the flicker limit should be related to the reference impedance. However, the European flicker test is designed for 230[V]/50[Hz] power and needs to be modified for a 1P2W(220[V]/60[Hz]) supply system in KOREA. In this paper, the reference impedance for KOREA(220[V]/60[Hz]) systems is proposed. The measured result provided in this paper was served as a proposal for establishing KOREA reference impedance for 220[V]/60[Hz] and has been published in IEC 60725.

Effects of 3D Images of a LCD Shutter Glass on Human Body in Virtual Environment (가상환경에서 Shutter glass 방식의 입체영상이 인체에 미치는 영향에 관한 연구)

  • 김종윤;송철규;김동욱;김남균
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.6
    • /
    • pp.607-614
    • /
    • 2000
  • 본 논문은 가상환경 노출에 따른 가상멀미와 같은 인체의 영향을 평가하기 위한 연구이다. 이를 위해 20명의 피험자를 대상으로 하여 30분 동안의 가상현실 환경 노출 전과 노출 후에 나타나는 인체의 영향을 분석하였다. 실험평가를 위한 파라미터로는 SSQ test, COP, flicker test, 체온변화, 심박수 변화, 그리고 눈 깜빡임 값들이 이용되었다. 3D 입체영상의 제시는 LSG에 의해서 이루어졌으며, 특히 flicker test시에서는 모니터, LSG, HMD를 모두 사용하여 피로도를 측정, 비교하였다. 본 연구결과, 가상현실 환경의 노출 전 보다 노출 후에서 SSQ score, COP, 체온, 눈 깜빡임, 그리고 심박수가 증가함을 알 수 있다.

  • PDF

A Study of Human Factor induced by Exposure to Virtual Environment (가상현실환경 노출이 인체에 미치는 영향에 관한 연구)

  • 김종윤;김호성;송철규;김남균
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.231-235
    • /
    • 2000
  • 본 논문은 가상환경 노출에 따른 가상멀미를 포함한 인체의 영향을 평가하기 위한 연구이다. 이를 위해 20명의 피험자를 대상으로 하여 30분 동안의 가상현실 환경 노출 전과 노출 후에 나타나는 인체의 영향을 분석하였다. 실험평가를 위한 파라미터로는 550 test, COP, flicker test, 체온변화, 그리고 심박수 변화, 눈 깜빡임 값들이 이용되었다. 3D 입체영상의 제시는 LSG에 의해서 이루어졌으며, 특히 flicker test시에서는 모니터, LSG, HMD를 모두 사용하여 피로도를 측정, 비교하였다. 본 연구결과, 가상현실 환경의 노출 전 보다 노출 후에서 SSe Score, COP, 체온, 눈 깜빡임, 심박수가 증가함을 알 수 있다.

  • PDF

A Study on the Condition of LED Lights Flicker (국내 LED 조명등에서 플리커 현상에 관한 연구)

  • Heo, Min;Ko, Jae-jun;Kim, Chung-hyeok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.11
    • /
    • pp.729-735
    • /
    • 2016
  • It is highly important issue to use an energy efficiently for sustainable prosperity of mankind. From this point of view, using LED lighting can be a good alternative because it has a lot of advantages such as high efficiency, long life time and eco-friendly manufacturing process. That is the reason why using LED lighting has been encouraged worldwide. However, in situations that LED lighting is replacing traditional lighting quickly, the problem of the flicker of LED lighting has emerged as an important issue. Therefore, in foreign countries like US or Japan in order to ensure the reliability of LED lighting, study for flickering effects of the human body and test methods are have been actively conducted. But related research in domestic situation is an insufficient condition. In this study, a flicker characteristic was measured conventional lamps such as incandescent lamps or fluorescent lamp and 81 items of LED lightings which are distributed in domestic markets.

Flicker Reduction Algorithm using Gamma Correction Parameter (감마보정 요소를 이용한 동영상 플리커 제거 알고리즘)

  • Choi, Heon-Hoi;Lee, Im-Geun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.397-400
    • /
    • 2010
  • The changing light condition of scene cause the luminance fluctuation of the captured image sequences. this artifact is called flicker, and would be easily recognized as visually unstable fluctuation. As the flicker degrades the performance of extracting useful information from image sequences, such as motion information or segmentation, it should be correction and linear flicker model. The algorithm model the flicker effects as a linear system with gain and offset parameter and estimates gain parameter with Gamma correction. The flicker reduction is performed by applying these parameters inversely th the ordinal sequences. To show the performance, we test out algorithm th the ground-truth sequences with the artificially added luminance fluctuation and real sequence with object motion.

  • PDF

2MVA SSFG(Sag Swell Flicker Generator) Development for Actual Test of Custom Power Device (전력품질 향상기기의 실증시험을 위한 2MVA SSFG(Sag Swell Flicker Generator) 개발)

  • Kim H.J.;Chung Y.H.;Kwon G.H.;Park T.B.;Moon J.I.;Jeon Y.S.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.626-633
    • /
    • 2005
  • This paper proposes a new 2MVA SSFG(Sag Swell Flicker Generator) injecting voltage by using series inverter. The proposed SSFG composes series inverter, DC capacitor as energy storage, rectifier and voltage clamp circuit. This SSFG is designed to generate typical power disturbances, such as voltage sag/swell, over/under voltage and voltage flicker. Also it is designed to generate unexpected voltage phase jumping waveform by controlling the series inverter. In this paper, three kinds of control methods for the proposed 2MVA SSFG we investigated by PSIM simulation. Also typical voltage sag, swell, flicker waveforms are implemented by adopting effective control method.

Analysis of the Distribution STATCOM for Improving the power factor and Mitigation of Voltage Flicker in Real System (전압플리커 저감과 역률 보상 기능을 갖는 배전용 STATCOM의 실계통연계 운전결과 분석)

  • Oh, Kwan-Il;Jeon, Young-Soo;Park, Sang-Tae;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.245-248
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, mitigation of voltage flicker and improving the power factor. It is shown that the STATCOM has clear advantages in areas such as: mitigation of voltage flicker and improving power factor.

  • PDF

A Study on Effect Estimation for Power Quality of Office Appliances (사무용 기기의 전기품질 영향 평가에 관한 연구)

  • 김응상;이재복;명성호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.55-63
    • /
    • 2002
  • Meet in the internationalization period recently and van every county is progressing unionization work of every county standard with the Europe, the United States of America. If our county does not correspond actively by age, economical disadvantage is expected. Tested PC, PC monitor, printer and harmonic for device for company business of FAX 4 kinds and flicker occurrence disgrace to achieve and analyze electricity quality test for office appliances by link of confrontation in such current in treatise that see therefore. As result that test printer and PC monitor ware stable but Desktop PC and FAX are presented in valid EN standard to January, 2004 that more than limit higher harmonics and flicker phenomenon appeared, and presented countermove in reply.