• 제목/요약/키워드: Flexural-torsional performance

검색결과 19건 처리시간 0.023초

Flexural-Torsional Coupled Vibration of Slewing Beams Using Various Types of Orthogonal Polynomials

  • Kapania Rakesh K.;Kim, Yong-Yook
    • Journal of Mechanical Science and Technology
    • /
    • 제20권11호
    • /
    • pp.1790-1800
    • /
    • 2006
  • Dynamic behavior of flexural-torsional coupled vibration of rotating beams using the Rayleigh-Ritz method with orthogonal polynomials as basis functions is studied. Performance of various orthogonal polynomials is compared to each other in terms of their efficiency and accuracy in determining the required natural frequencies. Orthogonal polynomials and functions studied in the present work are: Legendre, Chebyshev, integrated Legendre, modified Duncan polynomials, the special trigonometric functions used in conjunction with Hermite cubics, and beam characteristic orthogonal polynomials. A total of 5 cases of beam boundary conditions and rotation are studied for their natural frequencies. The obtained natural frequencies and mode shapes are compared to those available in various references and the results for coupled flexural-torsional vibrations are especially compared to both previously available references and with those obtained using NASTRAN finite element package. Among all the examined orthogonal functions, Legendre orthogonal polynomials are the most efficient in overall CPU time, mainly because of ease in performing the integration required for determining the stiffness and mass matrices.

Experimental evaluation on the seismic performance of high strength thin-walled composite members accounting for sectional aspect ratio effect

  • Hsu, H.L.;Juang, J.L.;Luo, K.T.
    • Steel and Composite Structures
    • /
    • 제9권4호
    • /
    • pp.367-380
    • /
    • 2009
  • This study focuses on the experimental evaluation of the flexural-torsional performance of high strength thin-walled composite members. A series of tests on composite members with various sectional aspect ratios subjected to eccentric cyclic loads were conducted. Test results show that the composite member's torsional strength could be approximated using a series of linear segments and evaluated using the superposition of the component steel and reinforced concrete responses. It is also validated from the tests that the strength deterioration of members subjected to combined loads is closely related to the aspect ratios of the sections. An interaction expression between the bending and torsion for high strength thin-walled composite members is proposed for engineering practice references.

Experimental and Numerical Assessment of the Service Behaviour of an Innovative Long-Span Precast Roof Element

  • Lago, Bruno Dal
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.261-273
    • /
    • 2017
  • The control of the deformative behaviour of pre-stressed concrete roof elements for a satisfactory service performance is a main issue of their structural design. Slender light-weight wing-shaped roof elements, typical of the European heritage, are particularly sensitive to this problem. The paper presents the results of deformation measurements during storage and of both torsional-flexural and purely flexural load tests carried out on a full-scale 40.5 m long innovative wing-shaped roof element. An element-based simplified integral procedure that de-couples the evolution of the deflection profile with the progressive shortening of the beam is adopted to catch the experimental visco-elastic behaviour of the element and the predictions are compared with normative close-form solutions. A linear 3D fem model is developed to investigate the torsional-flexural behaviour of the member. A mechanical non-linear beam model is used to predict the purely flexural behaviour of the roof member in the pre- and post-cracking phases and to validate the loss prediction of the adopted procedure. Both experimental and numerical results highlight that the adopted analysis method is viable and sound for an accurate simulation of the service behaviour of precast roof elements.

Cold-formed steel channel columns optimization with simulated annealing method

  • Kripka, Moacir;Chamberlain Pravia, Zacarias Martin
    • Structural Engineering and Mechanics
    • /
    • 제48권3호
    • /
    • pp.383-394
    • /
    • 2013
  • Cold-formed profiles have been largely used in the building industry because they can be easily produced and because they allow for a wide range of sections and thus can be utilized to meet different project requirements. Attainment of maximum performance by structural elements with low use of material is a challenge for engineering projects. This paper presents a numerical study aimed at minimizing the weight of lipped and unlipped cold-formed channel columns, following the AISI 2007 specification. Flexural, torsional and torsional-flexural buckling of columns was considered as constraints. The simulated annealing method was used for optimization. Several numerical simulations are presented and discussed to validate the proposal, in addition to an experimental example that qualifies its implementation. The ratios between lips, web width, and flange width are analyzed. Finally, it may be concluded that the optimization process yields excellent results in terms of cross-sectional area reduction.

자기변형 센서 바이어스 자기계의 요크 위상최적설계 (Yoke Topology Optimization of the Bias Magnetic System in a Magnetostrictive Sensor)

  • 김윤영;김우철
    • 대한기계학회논문집A
    • /
    • 제28권7호
    • /
    • pp.923-929
    • /
    • 2004
  • A magnetostrictive sensor is a sensor measuring elastic waves. Because of its unique non-contact measurement feature, the sensor receives more attentions in recent years. These sensors have been mainly used to measure longitudinal and torsional waves in ferromagnetic waveguides, but there increases an interest in using the sensor for flexural wave measurement. Since the performance of the sensor is strongly influenced by the applied bias magnetic field distribution, the design of the bias magnetic system providing the desired magnetic field is critical. The motivation of this investigation is to design a bias magnetic system consisting of electromagnets and yokes and the specific objective is to formulate the design problem as a bias yoke topology optimization. For the formulation, we employ linear magnetic behavior and examine the optimized results for electromagnets located at various locations. After completing the design optimization, we fabricate the prototype of the proposed bias magnetic system, and test its performance through flexural wave measurements.

Flexural Strength of cold-formed steel built-up composite beams with rectangular compression flanges

  • Dar, M. Adil;Subramanian, N.;Dar, Dawood A.;Dar, A.R.;Anbarasu, M.;Lim, James B.P.;Mahjoubi, Soroush
    • Steel and Composite Structures
    • /
    • 제34권2호
    • /
    • pp.171-188
    • /
    • 2020
  • The past research on cold-formed steel (CFS) flexural members have proved that rectangular hollow flanged sections perform better than conventional I-sections due to their higher torsional rigidity over the later ones. However, CFS members are vulnerable to local buckling, substantially due to their thin-walled features. The use of packing, such as firmly connected timber planks, to the flanges of conventional CFS lipped I-sections can drastically improve their flexural performance as well as structural efficiency. Whilst several CFS composites have been developed so far, only limited packing materials have been tried. This paper presents a series of tests carried out on different rectangular hollow compression flanged sections with innovative packing materials. Four-point flexural tests were carried out to assess the flexural capacity, failure modes and deformed shapes of the CFS composite beam specimens. The geometric imperfections were measured and reported. The North American Specifications and Indian Standard for cold-formed steel structures were used to compare the design strengths of the experimental specimen. The test results indicate clearly that CFS rectangular 'compression' flanged composite beams perform significantly better than the conventional rectangular hollow flanged CFS sections.

Static performance of a new GFRP-metal string truss bridge subjected to unsymmetrical loads

  • Zhang, Dongdong;Yuan, Jiaxin;Zhao, Qilin;Li, Feng;Gao, Yifeng;Zhu, Ruijie;Zhao, Zhiqin
    • Steel and Composite Structures
    • /
    • 제35권5호
    • /
    • pp.641-657
    • /
    • 2020
  • A unique lightweight string truss deployable bridge assembled by thin-walled fiber reinforced polymer (FRP) and metal profiles was designed for emergency applications. As a new structure, investigations into the static structural performance under the serviceability limit state are desired for examining the structural integrity of the developed bridge when subjected to unsymmetrical loadings characterized by combined torsion and bending. In this study, a full-scale experimental inspection was conducted on a fabricated bridge, and the combined flexural-torsional behavior was examined in terms of displacement and strains. The experimental structure showed favorable strength and rigidity performances to function as deployable bridge under unsymmetrical loading conditions and should be designed in accordance with the stiffness criterion, the same as that under symmetrical loads. In addition, a finite element model (FEM) with a simple modeling process, which considered the multi segments of the FRP members and realistic nodal stiffness of the complex unique hybrid nodal joints, was constructed and compared against experiments, demonstrating good agreement. A FEM-based numerical analysis was thereafter performed to explore the effect of the change in elastic modulus of different FRP elements on the static deformation of the bridge. The results confirmed that the change in elastic modulus of different types of FRP element members caused remarkable differences on the bending and torsional stiffness of the hybrid bridge. The global stiffness of such a unique bridge can be significantly enhanced by redesigning the critical lower string pull bars using designable FRP profiles with high elastic modulus.

HSA800 후판재의 완전용입 맞댐용접부 휨-인장강도 실험 (Flexural Tensile Strength of CJP Groove Welded Joints Connecting Thick HSA800 Plates)

  • 이철호;김대경;한규홍;박창희;김진호;이승은;김도환
    • 한국강구조학회 논문집
    • /
    • 제26권5호
    • /
    • pp.407-418
    • /
    • 2014
  • 본 연구에서는 HSA800 후판 강재에 적합한 용접재를 선정하고자 휨-인장실험을 수행하였다. 본 연구 수행 당시 HSA800 강재에 적용가능한 용접재로 GMAW 용접재(외국산)와 FCAW 용접재(국내산) 두 가지가 추천되어 이들을 사용하였다. 선행연구인 표준인장실험 결과를 바탕으로 맞댐용접상세와 루트간격을 주요 실험변수로하여 실물크기의 보 실험을 통해 용접부의 성능을 평가하였다. 강도 측면에서 모멘트 및 플랜지 축력 전달에 대한 조건은 두 용접재 모두 만족하였으나 연성능력 측면에서 GMAW 용접재보다는 FCAW 용접재가 일관되고 우수한 거동을 보임이 실험적으로 확인되었다. 특히 GMAW 용접재는 용접효율과 작업성의 문제로 현장에서의 상향용접이 어려운 것으로 파악되었다. 같은 완전용입용접이라도 Single bevel보다는 V-groove가 안정적인 구조거동을 보이는 것으로 나타났다. 표준인장실험결과와 휨-인장실험결과를 토대로 HSA800 후판재의 용접상세 및 용접재를 제시하였다.

Bridge widening with composite steel-concrete girders: application and analysis of live load distribution

  • Yang, Yue;Zhang, Xiaoguang;Fan, Jiansheng;Bai, Yu
    • Advances in concrete construction
    • /
    • 제3권4호
    • /
    • pp.295-316
    • /
    • 2015
  • A bridge widening technology using steel-concrete composite system was developed and is presented in this paper. The widened superstructure system consists of a newly built composite steel-concrete girder with concrete deck and steel diaphragms attached to the existing concrete girders. This method has been applied in several bridge widening projects in China, and one of those projects is presented in detail. Due to the higher stiffness-to-weight ratio and the rapid erection of composite girders, this widening method reveals benefits in both mechanical performance and construction. As only a few methods for the design of bridges with different types of girders are recommended in current design codes, a more accurate analytical method of estimating live load distribution on girder bridges was developed. In the analytical model, the effects of span length, girder pacing, diaphragms, concrete decks were considered, as well as the torsional and flexural stiffness of both composite box girders and concrete T girders. The study shows that the AASHTO LRFD specification procedures and the analytical models proposed in this paper closely approximate the live load distribution factors determined by finite element analysis. A parametric study was also conducted using the finite element method to evaluate the potential load carrying capacities of the existing concrete girders after widening.

Compression tests of cold-formed channel sections with perforations in the web

  • Kwon, Young Bong;Kim, Gap Deuk;Kwon, In Kyu
    • Steel and Composite Structures
    • /
    • 제16권6호
    • /
    • pp.657-679
    • /
    • 2014
  • This paper describes a series of compression tests performed on cold-formed steel channel sections with perforations in the web (thermal studs) fabricated from a galvanized steel plate whose thickness ranged from 1.0 mm to 1.6 mm and nominal yield stress was 295 MPa. The structural behavior and performance of thermal studs undergoing local, distortional, or flexural-torsional buckling were investigated experimentally and analytically. The compression tests indicate that the slits in the web had significant negative effects on the buckling and ultimate strength of thin-walled channel section columns. The compressive strength of perforated thermal studs was estimated using equivalent solid channel sections of reduced thickness instead of the studs. The direct strength method, a newly developed and adopted alternative to the effective width method for designing cold-formed steel sections in the AISI Standard S100 (2004) and AS/NZS 4600 (Standard Australia 2005), was calibrated to the test results for its application to cold-formed channel sections with slits in the web. The results verify that the DSM can predict the ultimate strength of channel section columns with slits in the web by substituting equivalent solid sections of reduced thickness for them.