• Title/Summary/Keyword: Flexible Array

Search Result 175, Processing Time 0.028 seconds

Inspection of Welded Zone and Flat Plate Using Flexible ECA Probe (Flexible ECA Probe를 이용한 평판 및 용접부 검사)

  • Lee, Chang-Jun;Lee, Kyu Sung;Shin, Chung-Ho;Lee, Kyoung-Jun;Jang, Yoon Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.4
    • /
    • pp.288-294
    • /
    • 2016
  • This paper aims to compare the ability to detect notch defects existing in the plate and welded area using a flexible ECA (eddy current array) probe with OmniScan MX and MS-5800E. The characteristics of signals with various frequencies and lift-offs were also compared. As a result, when signals of frequencies 500, 1000, and 1500 kHz were used, the amplitude of the signal increased, as the depth of the notch increased, but reduced linearly in accordance with the lift-off variation. In addition, the detection sensitivity of the weld defect was found to be closely related to the contact surface of the probe and specimen. In this paper, it was demonstrated that the detection sensitivity was excellent when the contact surface of the probe and the specimen was sufficient, but it was poor when the contact surface was insufficient.

Material & Structural Characteristics of Composite Material Flexible Propeller (복합재료 유연 프로펠러의 재료 및 구조적 특성 연구)

  • Lee, Sang-Gab;Hwang, Jeong-Oh;Byun, Joon-Hyung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.2
    • /
    • pp.203-217
    • /
    • 2009
  • The researches on the development of composite material propeller with outstanding damping effects have been actively attempted for the reduction of radiation noise of underwater vehicle propeller. Composite material suitable for the flexible propeller has the following advantages, such as high specific strength and specific stiffness, low thermal expansion coefficient, high resistance against environmental deterioration, low possibility of corrosion due to cavitation, nonoccurrence of rapid fracture due to fatigue, easy molding of complicated shape, easy repair maintenance and low production costs, etc. For the confirmation of optimal fiber array structures of composite material for the production of the flexible propeller blades, in this study, mechanical characteristics of its specimens according to materials were obtained and structural characteristics of propeller blade were also examined according to materials and stacking fiber arrays.

Development of silicon based flexible tactile sensor array mounted on flexible PCB (연성회로기판에 실장된 실리콘 기반의 유연 촉각센서 어레이 제작 및 평가)

  • Kim, K.N.;Kim, Y.K.;Lee, K.R.;Cho, W.S.;Lee, D.S.;Cho, N.K.;Kim, W.H.;Park, J.H.;Kim, S.W.;Ju, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.277-283
    • /
    • 2006
  • We presented that fabrication process and characteristics of 3 axes flexible tactile sensor available for normal and shear force fabricated using Si micromachining and packaging technologies. The fabrication processes for 3 axes flexible tactile sensor were classified in the fabrication of sensor chips and their packaging on the flexible PCB. The variation rate of resistance was about 2.1 %/N and 0.5 %/N in applying normal and shear force, respectively. The flexibility of fabricated 3 axes flexible tactile sensor array was good enough to place on the finger-tip.

Fabrication and Performance Evaluation of Temperature Sensor Matrix Using a Flexible Printed Circuit Board for the Visualization of Temperature Field (온도장 가시화를 위한 연성회로기판을 이용한 온도센서 어레이 제작 및 성능평가)

  • Ahn, Cheol-Hee;Kim, Hyung-Hoon;Cha, Je-Myung;Kwon, Bong-Hyun;Ha, Man-Yeong;Park, Sang-Hu;Jeong, Ji-Hwan;Kim, Kui-Soon;Cho, Jong-Rae;Son, Chang-Min;Lee, Jung-Ho;Go, Jeung-Sang
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.2
    • /
    • pp.17-21
    • /
    • 2010
  • This paper presents the fabrication and performance measurement of a temperature sensor array on a flexible substrate attachable to a curved surface using MEMS technology. Specifically, the fabrication uses the well-developed printed circuit board fabrication technology for complex electrode definition. The temperature sensor array are lifted off with a $10{\times}10$ matrix in a $50\;mm{\times}50\;mm$ to visualize temperature distribution. Copper is used as temperature sensing material to measure the change in resistances with temperature increase. In a thermal oven with temperature control, the temperature sensor array is Characterized. The constant slope of resistance change is obtained and temperature distribution is measured from the relationship between resistance and temperature.

Development of Retinal Prosthesis Module for Fully Implantable Retinal Prosthesis (완전삽입형 인공망막 구현을 위한 인공망막모듈 개발)

  • Lee, Kang-Wook;Kaiho, Yoshiyuki;Fukushima, Takafumi;Tanaka, Tetsu;Koyanagi, Mitsumasa
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.292-301
    • /
    • 2010
  • To restore visual sensation of blind patients, we have proposed a fully implantable retinal prosthesis comprising an three dimensionally (3D) stacked retinal chip for transforming optical signal to electrical signal, a flexible cable with stimulus electrode array for stimulating retina cells, and coupling coils for power transmission. The 3D stacked retinal chip is consisted of several LSI chips such as photodetector, signal processing circuit, and stimulus current generator. They are vertically stacked and electrically connected using 3D integration technology. Our retinal prosthesis has a small size and lightweight with high resolution, therefore it could increase the patients` quality of life (QOL). For realizing the fully implantable retinal prosthesis, we developed a retinal prosthesis module comprising a retinal prosthesis chip and a flexible cable with stimulus electrode array for generating optimal stimulus current. In this study, we used a 2D retinal chip as a prototype retinal prosthesis chip. We fabricated the polymide-based flexible cable of $20{\mu}m$ thickness where 16 channels Pt stimulus electrode array was formed in the cable. Pt electrode has an impedance of $9.9k{\Omega}$ at 400Hz frequency. The retinal prosthesis chip was mounted on the flexible cable by an epoxy and electrically connected by Au wire. The retinal prosthesis chip was cappted by a silicone to pretect from corrosive environments in an eyeball. Then, the fabricated retinal prosthesis module was implanted into an eyeball of a rabbit. We successfully recorded electrically evoked potential (EEP) elicited from the rabbit brain by the current stimulation supplied from the implanted retinal prosthesis module. EEP amplitude was increased linearly with illumination intensity and irradiation time of incident light. The retinal prosthesis chip was well functioned after implanting into the eyeball of the rabbit.

Fabrication of Vertically Oriented ZnO Micro-crystals array embedded in Polymeric matrix for Flexible Device (수열합성을 이용한 ZnO 마이크로 구조의 성장 및 전사)

  • Yang, Dong Won;Lee, Won Woo;Park, Won IL
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.31-37
    • /
    • 2017
  • Recently, there has been substantial interest in flexible and wearable devices whose properties and performances are close to conventional devices on hard substrates. Despite the advancement on flexible devices with organic semiconductors or carbon nanotube films, their performances are limited by the carrier scattering at the molecular to molecular or nanotube-to-nanotube junctions. Here in this study, we demonstrate on the vertical semiconductor crystal array embedded in flexible polymer matrix. Such structures can relieve the strain effectively, thereby accommodating large flexural deformation. To achieve such structure, we first established a low-temperature solution-phase synthesis of single crystalline 3D architectures consisting of epitaxially grown ZnO constituent crystals by position and growth direction controlled growth strategy. The ZnO vertical crystal array was integrated into a piece of polydimethylsiloxane (PDMS) substrate, which was then mechanically detached from the hard substrate to achieve the freestanding ZnO-polymer composite. In addition, the characteristics of transferred ZnO were confirmed by additional structural and photoluminescent measurements. The ZnO vertical crystal array embedded in PDMS was further employed as pressure sensor that exhibited an active response to the external pressure, by piezoelectric effect of ZnO crystal.

Numerical and Experimental Study on Plate Forming Process using Flexible Die (가변금형을 이용한 판재 성형에 대한 해석 및 실험)

  • Heo, S.C.;Seo, Y.H.;Park, J.W.;Ku, T.W.;Kim, J.;Kang, B.S.
    • Transactions of Materials Processing
    • /
    • v.17 no.8
    • /
    • pp.570-578
    • /
    • 2008
  • A flexible forming apparatus is composed a number of punches which have spherical pin tip shape instead of conventional solid die. The flexible forming tool consisted of punch array in a matrix form was proposed as an alternative forming method to substitute the conventional line heating method which use heat source to induce residual stress along specified heating lines. In this study, application of the flexible forming process to the small scale curved plate forming was conducted. Numerical simulations for both solid and flexible die forming process were carried out to compare the shape of the products between flexible and conventional die forming process. In addition, spring-back analysis was conducted to figure out the feasibility of the flexible forming process comparing with the die forming process in view of final configuration of the specimens. Moreover, experiment was also carried out to confirm the formability of the process. Consequently, it was confirmed that the flexible die forming method has capability and feasibility to manufacture the curved plates for shipbuilding.

Control the Length of Carbon Nanotube Array by Using Oxygen Plasma Etching Process (산소플라즈마 에칭공정을 응용한 탄소나노튜브 Array 길이 제어 연구)

  • Song, Yoo-Jin;Kang, Seong-Jun
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.6
    • /
    • pp.488-493
    • /
    • 2009
  • We developed a simple method to control the length of carbon nanotube array by using oxygen plasma etching. In this way, we could obtain a carbon nanotube with a uniform length (20, 30, 50, $70\;{\mu}m$), that was parallel to the substrate. Moreover, our growing method of carbon nanotube array gives a uniform diameter ~3.5nm, which is consistent with our previous results. Using the same etching method, we demonstrated the carbon nanotube radio frequency identification (RFID) antenna. The results could be useful for carbon nanotube applications such as flexible and transparent conductive films.

Vortex-induced reconfiguration of a tandem arrangement of flexible cylinders

  • Lee, Sang Joon;Kim, Jeong Jae;Yeom, Eunseop
    • Wind and Structures
    • /
    • v.21 no.1
    • /
    • pp.25-40
    • /
    • 2015
  • Oscillating motions of flexible cylinders are associated to some extent with the aerodynamic response of plants. Tandem motions of reeds with flexible stems in a colony are experimentally investigated using an array of flexible cylinders made of polydimethylsiloxane (PDMS). Consecutive images of flexible cylinders subjected to oncoming wind are recorded with a high-speed camera. To quantify oscillating motions, the average bending angle and displacement of flexible cylinders are evaluated using point-tracking method and spectral analysis. The tandem motions of flexible cylinders are closely related to the flow characteristics around the cylinders. Thus, the dynamic motions of a tandem arrangement of flexible cylinders are investigated with varying numbers of cylinders arranged in-line, numbers of cylinders in a group (behaving like a single body), and Reynolds numbers (Re). When the number of cylinders in a group increases, the damping effect caused by the support of downstream cylinders is pronounced. These results would be provide useful information on the tandem-arranged design of complex structures and energy harvesting devices.