• 제목/요약/키워드: Flat Transformer

검색결과 29건 처리시간 0.029초

대전류 출력형 Flat Transformer 설계 및 해석 기술 (Design and Simulation Technologies of Flat Transformer with High Power Current)

  • 한세원;조한구;우병철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.15-17
    • /
    • 2002
  • Leakage inductance and temperature rise are two of the more impotent problems facing the magnetic core technology of today's high frequency transformers. Excessive leakage inductance increases the stress on the switching transistors and limits the duty-cycle, and excessive temperature rise can lead the design limitation of high frequency transformer with high current. The flat transformer technology provides a very good solution to the problems of leakage inductance and thermal management for high frequency power. The critical magnetic components and windings are optimized and packaged within a completely assembled module. The turns ratio in a flat transformer is determined as the product of the number of elements or modules times the number of primary turns. The leakage inductance increase proportionately to the number of elements, but since it is reduced as the square of the turns, the net reduction can be very significant. The flat transformer modules use cores which have no gap. This eliminates fringing fluxes and stray flux outside of the core. The secondary windings are formed of flat metal and are bonded to the inside surface of the core. The secondary winding thus surrounds the primary winding, so nearly all of the flux is captured.

  • PDF

Flat Transformer 코아의 설계와 컨버터 동작 특성 (Study on designing of Flat Transformer and operating characteristics of Converter)

  • 한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.587-590
    • /
    • 2003
  • The first attention in designing a transformer for low temperature rise should be to reduce losses. Leakage inductance and temperature rise are two of the more impotent problems facing the magnetic core technology of today's high frequency transformers. Excessive leakage inductance increases the stress on the switching transistors and limits the duty-cycle, and excessive temperature rise can lead the design limitation of high frequency transformer with high current. The flat transformer technology provides a very good solution to the problems of leakage inductance and thermal management for high frequency power. The critical magnetic components and windings are optimized and packaged within a completely assembled module. The turns ratio in a flat transformer is determined as the product of the number of elements or modules times the number of primary turns. The leakage inductance increase proportionately to the number of elements, but since it is reduced as the square of the turns, the net reduction can be very significant. The flat transformer modules use cores which have no gap. This eliminates fringing fluxes and stray flux outside of the core. The secondary windings are formed of flat metal and are bonded to the inside surface of the core. The secondary winding thus surrounds the primary winding, so nearly all of the flux is captured.

  • PDF

평면 동판 권선을 이용한 Flyback 변압기 설계에 관한 연구 (A Study on the Design of Flyback Transformer using Flat copper winding)

  • 김종해
    • 전기전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.445-455
    • /
    • 2022
  • 본 논문에서는 90W급 LED-TV용 DC-DC Flyback 컨버터에 사용되고 있는 소형화 및 권선 자동화에 적합한 사출형 평면 동판 권선 방식의 Flyback 변압기 최적화 설계에 대해서 나타낸다. 또한 본 논문에서는 수동권선방식의 기존 양산 Flyback 변압기에 비해 권선 자동화, Trans 체적 저감 및 전기적 특성 동질성 향상이 가능한 사출형 평면 동판 권선 방식의 Flyback 변압기를 제안한다. 특히 본 논문에서 제안한 사출형 평면 동판 권선 변압기는 권선 자동화를 위하여 수직형 권선 방식으로 구성한다. 본 논문 제안한 사출형 평면 동판 권선 방식의 Flyback 변압기의 1차측과 2차측 권선은 각각 기존 권선, 3중 절연 권선 및 사출형 평면 동판권선을 사용하였다. 최종적으로 Maxwell 2D 및 3D Tool을 이용한 시뮬레이션 결과를 토대로 본 논문에서 제안한 소형화 및 권선 자동화에 적합한 사출형 평면 동판 권선 방식의 Flyback 변압기 최적화 설계를 수행하였다.

Flat Transformer를 적용한 고밀도 전원장치 설계 (Design of the High Density Power Supply with Flat Transformer)

  • 백주원;김종현;유동욱;김종수;류명효
    • 전력전자학회논문지
    • /
    • 제10권3호
    • /
    • pp.248-256
    • /
    • 2005
  • 본 논문에서는 중$\cdot$대용량 고밀도 전원 장치에 적합한 플랫 트랜스포머(Flat Transformer)를 사용하여 다양한 출력의 DC/DC 변환장치를 설계하는 방법을 제시하였다. 플랫 트랜스포머 모듈은 다수의 트랜스포머를 병렬로 구성하여 제작하고, 이차 권선이 항상 1턴으로 구성되므로 기존의 트랜스포머에 비해 누설 인덕턴스가 크게 감소하게 되어 고주파 스위칭에 적합한 형태를 가지고 있다. 본 논문에서는 플랫 트랜스포머의 성능을 증명하기 위하여 750W급 AC/DC 변환기를 구성하여 다양한 출력을 갖는 전원 장치를 제작/실험하였다.

Flat Transformer를 이용한 100W급 On-Board Power Supply (100W On-Board Power Supply Using Flat Transformer)

  • 황치면;송두익;조정구;정창용;홍승대;하태복
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.577-580
    • /
    • 1999
  • High power density on-board power supply is implemented by using flat transformer. In the high frequency switching converters, large leakage inductance increases the switching stress and duty cycle loss, which sometimes limits maximum switching frequency. The flat transformer is designed by using special core structure, which has very low profile and low temperature rise since the thermal loading is spread evenly over a larger area. 100W, 3.3V output on board supply is built and tested and 50.7W/$\textrm{inch}^{3}$ power density is achieved.

  • PDF

경방향 확장 진동모드를 이용한 강압용 압전변압기의 특성에 관한 연구 (A Study on Characteristics of Step-down Piezoelectric Transformer Using Contour Extended Vibration Mode)

  • 이원재;민복기;송재성;정현호;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.638-641
    • /
    • 2002
  • This paper presents design and construct of flat type step-down piezoelectric transformer for the application to AC-adapters. This piezoelectric transformer operated in resonance vibration mode. In this paper, Finite element method(FEM) was used for analysis piezoelectric transformers. Vibration mode and electric field of piezoelectric transformer at resonance frequency were simulated. Using this simulation, we manufactured flat type piezoelecric transformer and measured its output characteristics. As results, output power was linearly increased by increasing input power at resonance frequency. And it was found that the transformer exhibited an output power of 11.4[W] at 60[V] input voltage. From these results, we expect that this piezoelecric transformer can be applied to AC adapters.

  • PDF

Flat TR용 페라이트 코아의 고주파 동작 특성 (Study on operating characteristics of Ferrite cores for Flat TR in high frequency)

  • 한세원;조한구;류동욱;최광보
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1168-1171
    • /
    • 2003
  • In contrast to a conventional transformer, the flat transformer is made using a number of small ferrite cores. Two cores for transformer and one core for inductor, which composed one module. Many modules can be connected together to form a flat matrix transformer. This structural arrangement eliminates the single hot spot problem in conventional transformers and permits high current density pertains at high frequency. In this study, the ferrite magnetic cores of Mn-Zn system for the Flat transformer were manufactured and the electrical and magnetic characteristics of its tested. The power loss of sample FO2(Mn-Zn ferrite) sintered at $1350^{\circ}C$ was $350kW/m^3$ in test conditions of 250kHz, 200mT and $100^{\circ}C$, which showed the good power loss property in high frequency. The power loss of FO2 samples has been studied as a function of magnetic flux density and frequency. Steinmetz exponent was 2.82 at 250kHz and 2.73 at 500kHz. These results illustrated the switching of power loss mechanism in ferrite core from hysteresis losses to eddy current losses or others.

  • PDF

Flat TR용 핵심 쿄아의 제조와 동작 특성 안정화 연구 (Study on manufacturing and operating characteristics of Magnetic cores for Flat TR)

  • 한세원;조한구;유동욱;류명효;최광보;김성배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.23-26
    • /
    • 2003
  • The flat transformer, typically, has a number of parallel single turn secondary windings. Each secondary winding is coupled to the same primary winding. Therefore, the current in each secondary winding is equal to the ampere-turns in the primary winding, and to each other. These characteristics are particularly advantageous where parallel rectifiers are used. The windings share the current equally, with no need for ballast resistors or other added components. In this study, the ferrite magnetic core samples of Mn-Zn system for the Flat transformer are manufactured and the electrical and magnetic characteristics of its tested. The density of sample FO2-2 sintered at $1350^{\circ}C$ is $4.00kg/m^3$, which shows the good microstructural state. The initial permeability and saturation flux density of FO2 at room temperature is 2700 and 510mT, individually. The power loss of FO2 samples at 250kHz have been ranged $350kW/m^3$ to $80kW/m^3$ with temperature. And the minimum power loss of sample FO2-2 showed at $70^{\circ}C$, which property seems very positive to apply for a flat transformer.

  • PDF

Flat Transformer 적용한 고밀도 전원장치 (High Density Power Supply with Flat Transformer)

  • 류명효;백주원;김종현;유동욱;임근희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.709-712
    • /
    • 2004
  • 본 논문에서는 고밀도 전원 장치에 적합한 플랫 트랜스포머(Flat Transformer)를 사용하여 다양한 출력을 갖는 AC/DC 변환장치의 설계 예를 제시하였다. 기존의 트랜스포머에 비해 플랫 트랜스포머는 다수의 트랜스포머를 병렬로 구성하여 제작하고, 이차 권선이 항상 1턴으로 구성되므로 누설 인덕턴스가 크게 감소하게 되어 고주파 스위칭에 적합한 형태를 가지고 있다. 일차측 AC/DC 변환기는 고조파 규제를 만족시키기 위해 경계 모드 (Boundary Mode)에서 동작하는 역률 보상회로로 구성하여 설계하였으며, 이차측 DC/DC 변환기는 플랫 트랜스포머에 적당한 하프 브리지(Half-Bridge) 컨버터를 적용하였다. 본 논문에서는 500W급 AC/]DC 변환기를 구성하여 다양한 출력을 갖는 전원 장치를 설계/제작하였다.

  • PDF

고출력 펄스응용을 위한 고전압 펄스변압기 최적설계 (Design Optimization of High-Voltage Pulse Transformer for High-Power Pulsed Application)

  • 장성덕;강흥식;박성주;한영진;조무현;남궁원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1297-1300
    • /
    • 2008
  • A conventional linear accelerator system requires a flat-topped pulse with less than ${\pm}$ 0.5% ripple to meet the beam energy spread requirements and to improve pulse efficiency of RF systems. A pulse transformer is one of main determinants on the output pulse voltage shape. The pulse transformer was investigated and analyzed with the pulse response characteristics using a simplified equivalent circuit model. The damping factor ${\sigma}$ must be >0.86 to limit the overshoot to less than 0.5% during the flat-top phase. The low leakage inductance and distributed capacitance are often limiting factors to obtain a fast rise time. These parameters are largely controlled by the physical geometry and winding configuration of the transformer. A rise time can be improved by reducing the number of turns, but it produces larger pulse droop and requires a larger core size. By tradeoffs among these parameters, the high-voltage pulse transformer with a pulse width of 10 ${\mu}s$, a rise time of 0.84 ${\mu}s$, and a pulse droop of 2.9% has been designed and fabricated to drive a klystron which has an output voltage of 284 kV, 30-MW peak and 60-kW average RF output power. This paper describes design optimization of a high-voltage pulse transformer for high-power pulsed applications. The experimental results were analyzed and compared with the design. The design and optimal tuning parameter of the system was identified using the model simulation.

  • PDF