• 제목/요약/키워드: Flat Rate

검색결과 786건 처리시간 0.032초

초고속인터넷 요금제 유형에 대한 비교 검토 : 정액제, 종량제 (Comparative Study on Internet Pricing : Flat-rate vs. Usage-based)

  • 송재도
    • 경영과학
    • /
    • 제26권1호
    • /
    • pp.21-35
    • /
    • 2009
  • There is a controversy on Internet pricing, flat-rate vs. usage-based. This study gives a comparative analysis between flat-rate and two-part tariff which is realistic alternative of usage-based pricing. In a basic economic model, two-part tariff based on ISP's cost structure satisfies allocative efficiency and relatively expand the number of subscribers. But the characteristics of Internet service like consumers' uncertainty on cost, measurement cost of traffic and network externality induce increase of cost or decrease of marginal utility. The analysis shows that small impact of these can make flat-rate more efficient.

티타늄 황삭가공에 있어서 공구형상이 공구마모율에 미치는 영향에 관한 연구 (A Study on Effect of Tool Wear Rate upon Cutting Tool Shape in a Titanium Rough Cut Machining)

  • 정화
    • 한국기계가공학회지
    • /
    • 제18권10호
    • /
    • pp.27-33
    • /
    • 2019
  • The aviation industry has grown beyond the simple processing and assembling of aircraft parts and now designs and exports finished aircraft. In this study, the vertical CNC milling rotational speed and feed rate were parameters to investigate the life of tools according to their shape: (flat, round, and ball end mill) in the rough cutting of titanium. These tools are widely used in aircraft manufacturing and assembly. The purpose of this study is to measure the cutting temperature generated during the cutting process and calculate the rate of tool wear. This will be accomplished by measuring the tool weight before and after cutting the specimen and to compare it with the results of previous studies. Our study showed that the maximum cutting temperature increased as cutting time, tool rotational speed, and feed rate increased. The highest cutting temperatures were recorded for the ball, round, and flat end mill, respectively. Tool wear for the ball, round, and flat end mill increased as the speed and feed rate increased. The flat end mill exhibited the highest rate of wear from a minimum of 0.62% to a maximum of 2.88%.

디지털 음악 콘텐츠 시장에서의 가격전략, 수익배분 및 시장구조 (Pricing Strategy, Profit Sharing, and Market Structure in Digital Music Contents Industry)

  • 장대철;안병훈
    • 한국경영과학회지
    • /
    • 제34권1호
    • /
    • pp.133-152
    • /
    • 2009
  • This paper analyze the fee structures of digital music contents and the revenue sharing ratios that are now on-going debates in Korean digital contents industry. Especially we consider Korean situation where copyrighters and telecom companies have conflict of interest. We found two major results. First, the choice between the flat rate scheme and the usage-based rate scheme is not important to telecom companies and copyrighters. The important thing is that copyrighters should decide the revenue sharing ratio and given that telecom companies should decide the retail price. Consequently, this way can lead to win-win solutions between them. Second, the flat rate scheme affects the relationship between consumers and telecom companies. Under the flat rate scheme, telecom companies have more benefits than consumers. In the vertical integrated structure, particularly, this tendency is more severe.

Seasonal Variation and Preservation Potential of Tidal-Flat Sediments on the Tidal Flat of Gomso Bay, West Coast of Korea

  • Chang, Jin-Ho
    • 한국제4기학회지
    • /
    • 제18권2호통권23호
    • /
    • pp.19-22
    • /
    • 2004
  • Seasonal changes of topograpy, sediment grain size and accumulation rate on the Gomso-Bay tidal flat(Fig. 1), west coast of Korea, have studied in order to understand the seasonal accumulation pattern and preservation potential of tidal-flat sediments. Seasonal levelings across the tidal flat show that the landward movement of both intertidal sand shoals and cheiers accelerates during the winter and typhoon period, but it almost stops in summer when mud deposition is instead predominant on the middle to upper tidal flat. Seasonal variations of mean grain size were largest on the upper part of middle tidal flat where summer mud layers were eroded during the winter and typhoon periods(Fig. 2). Measurements of accululation depths from sea floor to basal plate reveal that accumulation rates were seasonally controlled according to the elevation of tidal-flat surface(Table 1) : the upper flat, where the accumulation rate of summer was generally higher than that of winter, was characterized by a continuous deposition throughout the entire year, whereas on the middle flat, sediment accumulations were concentrated in winter realtive to summer, and were intermittently eroded by typhoons. The lower tidal flat were deposited mostly in winter and eroded during summer typhoons. Cancores taken across the tidal flat reveal that sand-mud interlaers resulting from such seasonal changes of energy regime are preserved only in the upper part of the deposits and generally replaced by storm layers downcore(Fig. 3). Based on above results, it is suggested that the storm deposits formed by winter stors and typhoons would consist of the major part of the Gomso-Bay deposits(Fig. 4).

  • PDF

평판형 집열기의 지관수에 따른 유동특성에 대한 수치해석 연구 (Numerical Study on the Flow Characteristics of Flat-Plate Solar Collector with Riser Number)

  • 김정배;이동원;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.143-148
    • /
    • 2007
  • It is essential to know the flow characteristics at the risers of Flat-plate solar collector for optimum design. For flat-plate solar collector, it is difficult to experimentally study the effect for the number of riser in the collector for the economic problem. So, this study was performed to show the flow characteristics of flat-plate solar collector with the number of riser using commercial code FLUENT 6.0. The base collector size is chosen with $2\;m^2$ as 1m by 2m in this study, the mass flow rate was estimated 0.04 kg/s using the mass flow rate of 0.02 kg/s per collector area for the certificate test. The number of riser is selected 4, 6, 8, 10, 12, and 14. Through the simulation, the conditions with the risers of 10 or 12 is shown as the optimum design conditions for conventional flat-plate solar collector considering lower pressure drop and more uniformly distributed mass flow rate for higher heat transfer rate without considering heat transfer.

W/C 70%인 모르타르에서의 갯벌 혼입률에 따른 특성 (Characteristic of mixing rate of mud flat on Mortar in W/C 70%)

  • 이흥열;안소현;양성환
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.30-31
    • /
    • 2016
  • Recently in the construction site is required various performance of mortar to deal with reliability, economy. Especially of environment-friendly, saving resources and high performance of mortar it began to require improvement of performance. Therefore, in this study, a series of tests was designed to develop a using mud flat mortar in view of the high absorption rate of tidal flats, to fix the water cement ratio to 70%. The mixing ratio were 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6 of fine aggregate and mud flats. Compared the flow value, chloride content, compressive strength, tensile strength, and workability of fine aggregate the substituted mud flat mortar and basic cement mortar, present the basic data on the characteristics and effects of mud flat mortar.

  • PDF

FRAME RATE CONVERSION IC FOR FULL HD 120 HZ LCD FLAT PANEL DISPLAYS

  • Schu, Markus;Hahn, Marko;Rieder, Peter
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1089-1092
    • /
    • 2007
  • New display technologies including LCD and plasma panels and Digital Light Projection (DLP) systems all offer large screens and impressive picture quality. However, flat-panel displays require a sophisticated picture processing to let these panels perform at their optimum levels. This paper explains why motion compensating techniques combined with frame rate conversion and quasi-impulse driving reduces motion blur and film judder for flat panel displays and presents the IC and its system application using this technique.

  • PDF

A Study on the Thermal Performance of Embossing Surface Sandwich Panel

  • Son, Cheol-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권2호
    • /
    • pp.69-76
    • /
    • 2001
  • The purpose of this research is to investigate the thermal performance of embossing surface sandwich panel and flat surface sandwich panel. To do this research, thermal performances in summer season at the six points of embossing surface sandwich panel and flat surface sandwich panel are investigated focusing on the temperature. Three kinds of embossing surface sandwich panel and one kind of flat surface sandwich panel are used for this research. At the same size of sandwich panel, the average temperature differences of flat surface sandwich panel between average temperature at the 0.5 mm below copper plate and average outside air temperature and surface temperature are higher than those of embossing surface sandwich panel. The average heat transfer rate of flat surface sandwich panel in higher than that of embossing surface sandwich panel. More study will be needed about the size of diameter and height of embossing, and materials of embossing surface sandwich panel.

  • PDF

여름철 엠보싱 샌드위치 패널의 열적 성능에 관한 연구 -평판 샌드위치 패널과 비교를 중심으로- (A Study on the Thermal Performance of Embossing Surface Sandwich Panel During the Summer)

  • 손철수
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.917-924
    • /
    • 2000
  • The purpose of this research is to investigate the thermal performance of embossing surface sandwich panel and flat surface sandwich panel during the summer. To do this research, thermal performances in summer season at the six points of embossing surface sandwich panel and flat surface sandwich panel are investigated focusing on the temperature. Three kinds of embossing surface sandwich panel and one kind of flat surface sandwich panel are used for this research. At the same size of sandwich panel, the average temperature differences of flat surface sandwich panel between average temperature at the 0.5 mm below copper plate and average outside air temperature and surface temperature are higher than those of embossing surface sandwich panel. The average heat transfer rate of flat surface sandwich panel is higher than that of embossing surface sandwich panel. More study will be needed about the size of diameter and height of embossing, and materials of embossing surface sandwich panel.

  • PDF

반도체용 저온 열처리로의 Flat Zone 확장 및 온도편차 감소에 관한 연구 (Study on the Flat Zone Expansion and Temperature Deviation Reduction of Low Temperature Furnace for Semiconductor Process)

  • 주강우;심승술;장혁;이유영;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제13권4호
    • /
    • pp.83-90
    • /
    • 2014
  • This paper is about the yield rate of lower temperature furnace for wafer heat-treatment. The flat-zone that the temperature in furnace has uniform distribution specific area is the significant variable to the yield rate. In this study, we researched about the ways how to widen the flat zone in the furnace using CFD. As a result, we confirmed that the characteristic of the flat-zone was changed when SCU(Super Cooling Unit) was used. We considered temperature control with above.