• Title/Summary/Keyword: Flash Over

Search Result 189, Processing Time 0.02 seconds

A Study on the Evacuation Performance Review for the Office Buildings (업무용 빌딩의 피난 성능 검토에 관한 연구)

  • 오혁진;백승태;김우석;이수경
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.1-6
    • /
    • 2003
  • In this study, it reviewed about evacuation performance of a specified Office Building. assessment tools is FAST 3.1.7 (Estimation of Flash Over, Estimation of Layer Height Down Flow Time), SIMULEX 32-bit (Estimation of Evacuation Time), JASMINE 3.25d. (Smoke Flow Assessment of a specified time) Result from Fire Scenario # 1, Flash Over is not generated in Compartment. Evacuation Time is estimated 25.2 sec by SIMULEX 32-bit. layer height until this time (25.2 sec) was estimated 2.4 m by FAST 3.1.7. After ignition until this time (25.2 sec), smoke was not release to the a corridor. In consequence, We concluded that people in building are completing the safe evacuation without the damage of smoke. Result from Fire Scenario # 1, Flash Over generated 6 min 33.2 sec in Compartment. Evacuation Time is estimated 1 min 25.5 sec by SIMULEX 32-bit. layer height down flow time is 1 min 40.8 sec by FAST 3.1.7 and 5 min 23 sec by theoretical calculation. Also, total building evacuation time was estimated 2 min 26.6 sec. After ignition until this time (2 min 26.6 sec), smoke released to the a corridor but it amount was few little. Therefore, generated smoke in compartment not effected to the people in buildings.

Precise spectral analysis using a multiple band-pass filter for flash-visual evoked potentials

  • Asano, Fumitaka;Shimoyama, Ichiro;Kasagi, Yasufumi;Lopez, Alex
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.05a
    • /
    • pp.44-50
    • /
    • 2002
  • The fast Fourier transform (FFT) is a good method to estimate spectral density, but the frequency resolution is limited to the sampling window, and thus the precise characteristics of the spectral density for short signals are not clear. To solve the limitation, a multiple band-pass filter was introduced to estimate the precise time course of the spectral density for flash visual evoked potentials (VEPs). Signals were recorded during -200 and 600 ms using balanced noncephalic electrodes, and sampled at 1 K Hz in 12 bits. With 1 Hz and 10 ms resolutions, spectral density was estimated between 10 and 100 Hz. Background powers at the alpha-and beta-bands were high over the posterior scalp, and powers around 200ms were evoked at the same bands over the same region, corresponding to P110 and N165 of VEPs. normalized's spectral density showed evoked powers around 200 ms and suppressed powers following the evoked powers over the posterior scalp. The evoked powers above the 20Hz band were not statistically significant. However, the gamma band was significantly evoked intra-individually; details in the gamma bands were varied among the subjects. Details of spectral density were complicated even for a simple task such as watching flashes; both synchronization and desynchronization occurred with different distributions and different time courses.

  • PDF

Implementation of a Prefetch method for Secondary Index Scan in MySQL InnoDB Engine (MySQL InnoDB엔진의 Secondary Index Scan을 위한 Prefetch 기능 구현)

  • Hwang, Dasom;Lee, Sang-Won
    • Journal of KIISE
    • /
    • v.44 no.2
    • /
    • pp.208-212
    • /
    • 2017
  • Flash SSDs have many advantages over the existing hard disks such as energy efficiency, shock resistance, and high I/O throughput. For these reasons, in combination with the emergence of innovative technologies such as 3D-NAND and V-NAND for cheaper cost-per-byte, flash SSDs have been rapidly replacing hard disks in many areas. However, the existing database engines, which have been developed mainly assuming hard disks as the storage, could not fully exploit the characteristics of flash SSDs (e.g. internal parallelism). In this paper, in order to utilize the internal parallelism intrinsic to modern flash SSDs for faster query processing, we implemented a prefetching method using asynchronous input/output as a new functionality for secondary index scans in MySQL InnoDB engine. Compared to the original InnoDB engine, the proposed prefetching-based scan scheme shows three-fold higher performance in the case of 16KB-page sizes, and about 4.2-fold higher performance in the case of 4KB-page sizes.

Flash Node Caching Scheme for Hybrid Hard Disk Systems (하이브리드 하드디스크 시스템을 위한 플래시 노드 캐싱 기법)

  • Byun, Si-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1696-1704
    • /
    • 2008
  • The conventional hard disk has been the dominant database storage system for over 25 years. Recently, hybrid systems which incorporate the advantages of flash memory into the conventional hard disks are considered to be the next dominant storage systems. Their features are satisfying the requirements like enhanced data I/O, energy consumption and reduced boot time, and they are sufficient to hybrid storage systems as major database storages. However, we need to improve traditional index management schemes based on B-Tree due to the relatively slow characteristics of hard disk operations, as compared to flashmemory. In order to achieve this goal, we propose a new index management scheme called FNC-Tree. FNC-Tree-based index management enhanced search and update performance by caching data objects in unused free area of flash leaf nodes to reduce slow hard disk I/Os in index access processes. Based on the results of the performance evaluation, we conclude that our scheme outperforms the traditional index management schemes.

The Analysis of Retention Characteristic according to Remnant Polarization(Pr) and Saturated Polarization(Ps) in 3D NAND Flash Memory (3D NAND Flash Memory의 Remnant Polarization(Pr)과 Saturated Polarization(Ps)에 따른 Retention 특성 분석)

  • Lee, Jaewoo;Kang, Myounggon
    • Journal of IKEEE
    • /
    • v.26 no.2
    • /
    • pp.329-332
    • /
    • 2022
  • In this paper, retention characteristics of lateral charge migration according to parameters of 3D NAND flash memory to which ferroelectric (HfO2) structure is applied and ∆Vth were analyzed. The larger the Ps, the greater maximum polarization possible in ferroelectric during Programming. Therefore, the initial Vth increases by about 1.04V difference at Ps 70µC/cm2 than at Ps 25µC/cm2. Also, electrons trapped after the Program operation causes lateral charge migration over time. Since ferroelectric maintains polarization without applying voltage to the gate after Programming, regardless of Ps value, polarization increases as Pr increases and the ∆Vth due to lateral charge migration becomes smaller by about 1.54V difference at Pr 50µC/cm2 than Pr 5µC/cm2.

A New Flash Memory Package Structure with Intelligent Buffer System and Performance Evaluation (버퍼 시스템을 내장한 새로운 플래쉬 메모리 패키지 구조 및 성능 평가)

  • Lee Jung-Hoon;Kim Shin-Dug
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.32 no.2
    • /
    • pp.75-84
    • /
    • 2005
  • This research is to design a high performance NAND-type flash memory package with a smart buffer cache that enhances the exploitation of spatial and temporal locality. The proposed buffer structure in a NAND flash memory package, called as a smart buffer cache, consists of three parts, i.e., a fully-associative victim buffer with a small block size, a fully-associative spatial buffer with a large block size, and a dynamic fetching unit. This new NAND-type flash memory package can achieve dramatically high performance and low power consumption comparing with any conventional NAND-type flash memory. Our results show that the NAND flash memory package with a smart buffer cache can reduce the miss ratio by around 70% and the average memory access time by around 67%, over the conventional NAND flash memory configuration. Also, the average miss ratio and average memory access time of the package module with smart buffer for a given buffer space (e.g., 3KB) can achieve better performance than package modules with a conventional direct-mapped buffer with eight times(e.g., 32KB) as much space and a fully-associative configuration with twice as much space(e.g., 8KB)

Flash memory system with spatial smart buffer for the substitution of a hard-disk (하드디스크 대용을 위한 공간적 스마트 버퍼 플래시 메모리 시스템)

  • Jung, Bo-Sung;Jung, Jung-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.3
    • /
    • pp.41-49
    • /
    • 2009
  • Flash memory has become increasingly requestion for the importance and the demand as a storage due to its low power consumption, cheap prices and large capacity medium. This research is to design a high performance flash memory structure for the substitution of a hard-disk by dynamic prefetching of aggressive spatial locality from the spatial smart buffer system. The proposed buffer system in a NAND flash memory consists of three parts, i.e., a fully associative victim buffer for temporal locality, a fully associative spatial buffer for spatial locality, and a dynamic fetching unit. We proposed new dynamic prefetching algorithm for aggressive spatial locality. That is to use the flash memory instead of the hard disk, the proposed flash system can achieve better performance gain by overcoming many drawbacks of the flash memory by the new structure and the new algorithm. According to the simulation results, compared with the smart buffer system, the average miss ratio is reduced about 26% for Mediabench applications. The average memory access times are improved about 35% for Mediabench applications, over 30% for Spec2000 applications.

Detection of flash drought using evaporative stress index in South Korea (증발스트레스지수를 활용한 국내 돌발가뭄 감지)

  • Lee, Hee-Jin;Nam, Won-Ho;Yoon, Dong-Hyun;Mark, D. Svoboda;Brian, D. Wardlow
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.8
    • /
    • pp.577-587
    • /
    • 2021
  • Drought is generally considered to be a natural disaster caused by accumulated water shortages over a long period of time, taking months or years and slowly occurring. However, climate change has led to rapid changes in weather and environmental factors that directly affect agriculture, and extreme weather conditions have led to an increase in the frequency of rapidly developing droughts within weeks to months. This phenomenon is defined as 'Flash Drought', which is caused by an increase in surface temperature over a relatively short period of time and abnormally low and rapidly decreasing soil moisture. The detection and analysis of flash drought is essential because it has a significant impact on agriculture and natural ecosystems, and its impacts are associated with agricultural drought impacts. In South Korea, there is no clear definition of flash drought, so the purpose of this study is to identify and analyze its characteristics. In this study, flash drought detection condition was presented based on the satellite-derived drought index Evaporative Stress Index (ESI) from 2014 to 2018. ESI is used as an early warning indicator for rapidly-occurring flash drought a short period of time due to its similar relationship with reduced soil moisture content, lack of precipitation, increased evaporative demand due to low humidity, high temperature, and strong winds. The flash droughts were analyzed using hydrometeorological characteristics by comparing Standardized Precipitation Index (SPI), soil moisture, maximum temperature, relative humidity, wind speed, and precipitation. The correlation was analyzed based on the 8 weeks prior to the occurrence of the flash drought, and in most cases, a high correlation of 0.8(-0.8) or higher(lower) was expressed for ESI and SPI, soil moisture, and maximum temperature.

Statistical Characteristics of Recent Lightning Occurred over South Korea (최근 남한지역에서 발생한 낙뢰의 통계적 특성)

  • Eom, Hyo-Sik;Suh, Myoung-Seok
    • Journal of the Korean earth science society
    • /
    • v.30 no.2
    • /
    • pp.210-222
    • /
    • 2009
  • Lightning data, observed from total lightning detection system (TLDS) of KMA, for the recent five years (2002-2006) have been analyzed for temporal and spatial characteristics of frequency, intensity, duration, and flash rate. Lightning frequency varies largely with years (most frequent in 2006) and the lightning during the summer accounts for 75% of total flashes and only 0.6% of lightnings strike in cold season. In rainy season (JJAS), the ratio of positive flashes to negative ones is as low as 0.15, but it increases up to 0.98 in February. The seasonal variation of lightning duration is strongly linked with lightning occurrences, whereas flashes rates show weak seasonal variability. In a daily scale, lightning, on average, occurs more often at dawn (2 am, 5-7 am) and in the mid-afternoon (15 pm), and the lightning at dawn (around 5 am) is most intense during the day. The western inland areas md the West/South Sea show high lightning density during JJAS, whereas eastern part and the East Sea exhibit a low density of lightning. Considering the low ratio of positive flashes (0.15) for the whole analysis domain during summer period, Chungnam and Jeonbuk areas have a high ratio of flashes over 0.4. However, these should be analyzed with much caution because weak positive cloud-to-cloud discharges can be regarded as cloud-to-ground flashes. The western inland also exhibits long annual flash hours (15-24). And the W3st Sea has high flash rates as a result of large density and low flash hours. The most frequent time of lightning occurrence over most inland areas lies between mid-afternoon and early-evening, whereas mountainous and coastal areas, and the northern Kyoungki and Hwanghae provinces show the maximum lightning strikes in the morning and at dawn, respectively.

A Study on the Thermal Behaviour of Via Design in the Ceramic Package (세라믹 패키지 내에서 비아에 따른 열적 거동에 관한 연구)

  • 이우성;고영우;유찬세;김경철;박종철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.1
    • /
    • pp.39-43
    • /
    • 2003
  • Thermal management is very important for the success of high density circuit design in LTCC. In this paper, LTCC substrates containing thermal via and pad were fabricated in order to study the influence of the thermal dissipation. To realize the accurate thermal analysis for structure design, a series of simple thermal conductivity measurement by laser flash method and parametric numerical analysis have been carried out. The LTCC substrate including via and Ag pad has good thermal conductivity over 103 W/mK which is 44% value of pure Ag material. Thermal behaviors with via arrays, size and density in the LTCC substrate were studied by numerical method.

  • PDF