• 제목/요약/키워드: Flash Over

검색결과 188건 처리시간 0.025초

다중 플래시 메모리 기반 파일시스템의 성능개선을 위한 파일시스템 (File System for Performance Improvement in Multiple Flash Memory Chips)

  • 박제호
    • 반도체디스플레이기술학회지
    • /
    • 제7권3호
    • /
    • pp.17-21
    • /
    • 2008
  • Application of flash memory in mobile and ubiquitous related devices is rapidly being increased due to its low price and high performance. In addition, some notebook computers currently come out into market with a SSD(Solid State Disk) instead of hard-drive based storage system. Regarding this trend, applications need to increase the storage capacity using multiple flash memory chips for larger capacity sooner or later. Flash memory based storage subsystem should resolve the performance bottleneck for writing in perspective of speed and lifetime according to its physical property. In order to make flash memory storage work with tangible performance, reclaiming of invalid regions needs to be controlled in a particular manner to decrease the number of erasures and to distribute the erasures uniformly over the whole memory space as much as possible. In this paper, we study the performance of flash memory recycling algorithms and demonstrate that the proposed algorithm shows acceptable performance for flash memory storage with multiple chips. The proposed cleaning method partitions the memory space into candidate memory regions, to be reclaimed as free, by utilizing threshold values. The proposed algorithm handles the storage system in multi-layered style. The impact of the proposed policies is evaluated through a number of experiments.

  • PDF

애자류의 염해대책에 관한 기초연구 (A basic study on preventing insulators from salt accident)

  • 김원섭
    • 전기의세계
    • /
    • 제18권1호
    • /
    • pp.11-14
    • /
    • 1969
  • This paper shows experimentally one method of preventing porcelain insulators from salt accident likely to be caused in the region of sea coast. In this experiment some results that, if a conductor barrier is inserted into the flash over discharge path which is wetted by salt dissolved water, the flash over voltage found to be raised up, were gotten. This results may be actually applied to suspension insulator or bushing to prevent them from salt accidents.

  • PDF

플래시메모리 기반 컴퓨터시스템을 위한 고속 부팅 기법의 설계 및 성능평가 (Design and Evaluation of a Fast Boot-up Technique for Flash Memory based Computer Systems)

  • 임근수;김지홍;고건
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제32권11_12호
    • /
    • pp.587-597
    • /
    • 2005
  • 최근 플래시메모리에 기반한 내장형 컴퓨터시스템의 사용이 급증하고 있다. 이러한 내장형시스템은 일반적으로 빠른 부팅시간을 제공해야 한다 하지만 부팅과정에서 플래시메모리용 파일시스템을 초기화하는 마운팅 시간이 플래시메모리의 크기에 따라 1-25초가량 소요된다. 현재 플래시메모리 단일 칩의 용량은 매년 2배씩 증가하는 추세에 있기 때문에 플래시메모리용 파일시스템을 마운트하는 시간이 내장형 시스템의 부팅시간을 지연시키는 중요한 요인이 될 것이다. 본 논문에서는 플래시메모리용 파일시스템의 메타데이타를 언마운팅 시점에 플래시메모리에 기록하고 이후에 마운팅하는 시점에 빠르게 읽어 들임으로써 마운팅 시간을 크게 단축하는 메타데이타 스냅샷 기법들을 NOR형과 NAND형 플래시메모리의 특성에 맞춰 설계한다. 파일시스템이 정상적으로 언마운트되지 않은 경우에는 이를 자동으로 인식하고 빠르게 에러를 복구할 수 있는 새로운 기법들을 사용한다. 성능평가를 통해서 제안하는 기법들은 대표적인 플래시메모리용 파일시스템인 JFFS2와 비교하여 마운팅 시간을 100배가량 단축시킴을 보인다.

MLC 낸드 플래시 기반 저장장치의 쓰기 성능 개선을 위한 계층 교차적 최적화 기법 (A Cross Layer Optimization Technique for Improving Performance of MLC NAND Flash-Based Storages)

  • 박지성;이성진;김지홍
    • 정보과학회 논문지
    • /
    • 제44권11호
    • /
    • pp.1130-1137
    • /
    • 2017
  • 하나의 메모리 셀에 여러 비트의 정보를 저장하는 다치화 기법은 공정 미세화와 함께 낸드 플래시 메모리의 집적도를 크게 향상시켰지만, 그 반대급부로 MLC 낸드 플래시 메모리의 평균 쓰기 성능은 SLC 낸드 플래시 메모리 대비 두 배 이상 하락하였다. 본 논문에서는 MLC 낸드 플래시 기반 저장장치의 성능 향상을 위해 제안되었던 기존의 계층 교차적 최적화 기법들을 소개하고, 두 기법의 상호 보완성을 분석하여 해당 기법들의 한계점을 극복하는 새로운 통합 기법을 제안한다. MLC 낸드 플래시 디바이스에 존재하는 성능 비대칭성을 플래시 변환 계층 수준에서 최대한 활용함으로써, 제안하는 기법은 인가되는 다수의 쓰기 명령을 SLC 낸드 플래시 디바이스의 성능으로 처리하여 저장장치의 성능 향상을 도모한다. 실험 결과, 제안하는 기법은 기존 기법 대비 평균 39%의 성능 향상을 달성할 수 있음을 확인하였다.

섬광의 적외선 특성 연구 (Infrared Characteristics of Some Flash Light Sources)

  • 임상연;박승만
    • 한국광학회지
    • /
    • 제27권1호
    • /
    • pp.18-24
    • /
    • 2016
  • 섬광을 효율적으로 활용하고 그 효과를 예측하기 위해서는 섬광의 광 방출특성을 알아야 하는 것은 필수적이다. 본 논문에서는 섬광의 효과예측과 효율적 활용을 위한 섬광의 적외선 특성을 연구하였다. 세 종류의 섬광원에 대하여 중적외선과 원적외선영역에서 적외선 특성을 측정하고 이로부터 섬광의 복사휘도와 복사온도를 추출하여 섬광의 적외선 특성을 연구하였다. 세 종류의 섬광에 대해 중 원적외선 영역에서 적외선 스펙트럼 복사휘도를 추출한 결과는 섬광 A의 복사휘도가 상대적으로 제일 강하며 섬광 C, 섬광 B 순으로 분석되었다. 동일한 연소형 섬광인 섬광 A와 B의 복사휘도가 약 10배 이상 남을 알 수 있었으며, 이는 단지 화약량의 차이에 의해 나타나는 것이므로 화약량이 증가할수록 방출 적외선의 강도가 강해지는 것으로 해석된다. 또한 폭발형 섬광 C와 연소형 섬광 A, B를 비교해도 화약량에 따라 적외선 방출 강도가 달라지는 것을 알 수 있다. 두 적외선 영역에서 측정한 복사휘도로부터 복사온도를 추출하였다. 섬광 A의 복사온도는 3300 K, 섬광 B는 1120 K, 섬광 C는 1640 K로 추출되었다. 두 적외선 영역에서 측정한 적외선 복사휘도, 복사온도 그리고 섬광의 지속시간을 종합하여 볼 때, 연소형 섬광이 폭발형보다 더 많은 적외선 에너지를 방출하는 것으로 분석되며, 이는 적외선 관측장비에 미치는 영향은 폭발형보다는 연소형이 더 크게 됨을 의미한다. 이러한 측정된 자료를 바탕으로 분석을 통해 확보된 섬광의 스펙트럼 복사휘도와 복사온도는 섬광이 적외선 장비에 미치는 영향을 추정하는데 매우 중요한 역할을 할 수 있으며, 나아가 섬광효과의 M&S에 기반을 제공할 것으로 기대된다.

하이브리드 저장 시스템을 위한 내장형 노드 캐시 관리 (Embedded Node Cache Management for Hybrid Storage Systems)

  • 변시우;허문행;노창배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.157-159
    • /
    • 2007
  • The conventional hard disk has been the dominant database storage system for over 25 years. Recently, hybrid systems which incorporate the advantages of flash memory into the conventional hard disks are considered to be the next dominant storage systems to support databases for desktops and server computers. Their features are satisfying the requirements like enhanced data I/O, energy consumption and reduced boot time, and they are sufficient to hybrid storage systems as major database storages. However, we need to improve traditional index node management schemes based on B-Tree due to the relatively slow characteristics of hard disk operations, as compared to flash memory. In order to achieve this goal, we propose a new index node management scheme called FNC-Tree. FNC-Tree-based index node management enhanced search and update performance by caching data objects in unused free area of flash leaf nodes to reduce slow hard disk I/Os in index access processes.

  • PDF

SSD를 위한 최적화 파일시스템 (An Optimized File System for SSD)

  • 박제호
    • 반도체디스플레이기술학회지
    • /
    • 제9권2호
    • /
    • pp.67-72
    • /
    • 2010
  • Recently increasing application of flash memory in mobile and ubiquitous related devices is due to its non-volatility, fast response time, shock resistance and low power consumption. Following this trend, SSD(Solid State Disk) using multiple flash chips, instead of hard-drive based storage system, started to widely used for its advantageous features. However, flash memory based storage subsystem should resolve the performance bottleneck for writing in perspective of speed and lifetime according to its disadvantageous physical property. In order to provide tangible performance, solutions are studied in aspect of reclaiming of invalid regions by decreasing the number of erasures and distributing the erasures uniformly over the whole memory space as much as possible. In this paper, we study flash memory recycling algorithms with multiple management units and demonstrate that the proposed algorithm provides feasible performance. The proposed method utilizes the partitions of the memory space by utilizing threshold values and reconfigures the management units if necessary. The performance of the proposed policies is evaluated through a number of simulation based experiments.

산악지역 돌발홍수 기준우량 결정에 관한 연구 (A Study on Flash Flood Warning Trigger Rainfall in Mountainous Area)

  • 전계원;오채연
    • 한국안전학회지
    • /
    • 제24권1호
    • /
    • pp.89-94
    • /
    • 2009
  • The purpose of this study is to estimate the critical flood discharge and flash flood trigger rainfall for alarm system providing for a flash flood in mountainous area. The flash flood need non-linear approaching method, because rainfall-runoff is nonlinear and it is difficult to explain the existing linear rainfall-runoff. Hydrological characteristics would be utilized to apply such as hydrologic modelling or basin management. This study was effectively estimated a topographic characteristic factor of basin using the GIS. Especially, decided stream order using GIS at stream order decision that is important for input variable of GCIUH. A flash floods defined as a flood which follows shortly after a heavy or excessive rainfall event, with a few hours. In this study, we gave a definition that a critical flood for alarm is the flood when valley depth judging dangerous depth is over 0.5m depth from the bottom of channel. Result that calculate threshold discharge to use GCIUH, at the Mureung valley basin, flash flood trigger rainfall was 16.34mm in the first 20minutes when the threshold discharge was $14.54m^3/sec$.

동적 로그 페이지 할당을 이용한 플래시-고려 DBMS의 스토리지 관리 기법 (Flash-Conscious Storage Management Method for DBMS using Dynamic Log Page Allocation)

  • 송석일;길기정;최길성
    • 한국항행학회논문지
    • /
    • 제14권5호
    • /
    • pp.767-774
    • /
    • 2010
  • NAND 플래시 메모리는 높은 입출력 성능, 내장애성, 저전력 소모 등 여러 가지 장점을 가지고 있어서 하드디스크를 대체할 수 있는 새로운 저장 장치로 관심을 받고 있다. 전통적인 DBMS들은 FTL (Flash Translation Layer)를 이용하면 전혀 수정 없이 플래시 메모리 위에서 동작한다. 그러나, 대부분의 FTL은 DBMS가 아닌 파일 시스템에 최적화 되어있다. 또한, 전통적인 DBMS는 플래시 메모리의 특징 (erase-before-write) 을 고려하지 않고 있다. 이 논문에서는 플래시 메모리를 이차 저장장치로 사용하는 DBMS를 위한 플래시 고려하는 스토리지 시스템을 제안한다. 제안하는 플래시 고려 스토리지 시스템은 비용이 높은 변경 연산을 피하기 위해 로그 레코드를 이용한다. 마지막으로, 실험을 통해서 제안하는 스토리지 시스템이 기존에 제안된 플래시를 고려하는 DBMS에 비해 우수함을 보인다.

플래쉬 메모리 관리 알고리즘 개발 (Development of Flash Memory Management Algorithm)

  • 박인규
    • 전자공학회논문지CI
    • /
    • 제38권1호
    • /
    • pp.26-45
    • /
    • 2001
  • 플래쉬 메모리는 데이터의 저장과 변경이 가능하고 전원이 차단되어도 저장된 데이터를 보존할 수 있는 RAM과 ROM의 장점을 모두 가지고 있는 메모리로서, 고성능의 전기 특성을 가지고 있어 이동 환경에서의 저장매체로 매우 접합하다. 향후 많은 정보단말기에 사용하게 될 플래쉬 메모리 및 스마트미디어 카드에 파일을 저장, 삭제, 재생하는 효과적인 알고리즘이 필요하다. 플래쉬 메모리를 일정한 크기의 세그먼트로 할당하고, 파일을 여러 개의 세그먼트로 분산시켜 관리한다. 본 논문에서는 특정 파일이 저장되어 있는 위치를 저장하는 테이블 및 보조 테이블을 이용하여 효과적인 파일 관리 알고리즘을 제시한다. 기존의 알고리즘은 비교적 작은 용량의 플래쉬 메모리를 관리하고 비교적 파일을 빈번한 횟수의 고속 저장, 삭제 등의 작동이 요구되는 응용에는 적합지 않는다. 본 논문에서 제안된 알고리즘은 몇 개의 플래쉬 메모리 칩 및 스마트미디어 카드로 구성된 비교적 큰 용량의 메모리 관리에 적합하다.

  • PDF