• 제목/요약/키워드: Flame retardant performance

검색결과 101건 처리시간 0.02초

막재료의 난연 및 방염성능 실험에 대한 연구 (Tests of Fire and Flame Retardant Performance for Membrane Materials)

  • 김기철;최광호
    • 한국공간구조학회논문집
    • /
    • 제16권2호
    • /
    • pp.55-60
    • /
    • 2016
  • The Membrane structure has a number of problems in the application of a fireproof code based on general buildings codes. Thus, the fireproof code of membrane structure is necessary to activate the construction of the membrane structure. Because it requires a systematic classification of fire retardant and flame proof performance of membrane material. Fire retardant and flame proof tests are conducted on membrane materials mostly used in current construction to propose the fire and flame retardant performance criteria of membrane materials. Fire and flame retardant tests results, PTFE membrane material with the glass fiber fabric have a limit-combustible performance. PVDF membrane material with the polyester fabric does not ensure the fire retardant performance, but this membrane material has the flame retardant performance of a thick fabric. Also, ETFE does not ensure the fire retardant performance, but this membrane material has the flame retardant of a thin fabric.

현장방염처리제도의 실효성 확보 방안에 관한 연구 (A Study on the Ways of Securing the Effectiveness of Field Flame Retardant Coating Process)

  • 박성현;백은선
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.95-100
    • /
    • 2011
  • 본 연구는 현장방염처리 물품에 대한 성능검사와 관련하여 불합리한 제도를 개선하고, 합리적인 방염성능검사 방법을 통하여 현장방염처리 물품에 대한 방염의 신뢰성을 확보하는데 궁극적인 목적이 있다. 이를 위해 최근 2년 동안 일선 소방관서에서 실시한 현장방염처리 물품에 대한 방염성능검사 실적을 토대로 최근에 사용되는 인테리어 마감자재 및 현장방염처리 경향에 대한 분석을 하였다. 또한 현장방염처리물품에 대한 성능검사 방법 및 절차, 방염처리업 등록제도의 문제점 등을 분석하여 현 실정에 적합한 방염성능검사 방법 및 성능검사의 신뢰성 확보를 위한 개선방안을 제시하고자 하였다.

방염처리된 단청목재의 방염성능 및 유독성에 관한 연구 (A Study on the Flame Retardant Performance and Toxicity of the Painting Wood Painted with Flame Retardant Solution)

  • 김인범;현성호
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.66-71
    • /
    • 2009
  • 본 연구에서는 방염처리 단청목재에 대한 방염성능 및 연소가스를 분석하여 그 독성지수에 근거한 유독성을 평가하였다. 시료에 대한 방염처리방법과 시료처리의 환경조건은 방염성능에 크게 영향을 미치지 않았다. 연소가스의 발생량은 방염액을 분무도포한 시료들에서 거의 비슷한 발생량을 보였고 독성지수는 위험등급 III에 해당하는 높은 위험도를 나타내었고, 방염액을 가압함침시킨 시료가 상대적으로 낮은 위험도인 위험등급 II를 나타내었다.

방염처리 방법에 따른 MDF 목재의 방염성능에 관한 연구 (A Study on the Flame Retardant Performance of MDF Wood According to Flame Retardant Treatment Method)

  • 차정민;현성호;김인범;윤명오
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.146-155
    • /
    • 2011
  • 본 연구에서는 현장방염처리(방염후처리)가 적용되고 있는 MDF 목재에 국내에서 유통되는 5개사 제품을 MDF 목재에 부착한 방염필름과 MDF 목재(무처리, 비방염필름)에 수성 유성 방염도료로 도포된 시편을 대상으로 현재 시중에서 사용되고 있는 방염처리 방법에 따라 방염성능을 비교하는 실험을 실시하였다. MDF 목재에 5개사의 방염필름을 부착하여 연소 시험한 결과 2개사 제품은 4가지 기준 내에 적합한 값을 나타냈으나 나머지 3개사 제품은 10~40 %의 불합격률을 나타냈다. 방염도료의 특성별로는 유성방염도료가 수성방염도료보다 방염성능 기준 내에서는 더 우수한 것으로 나타났지만 유성방염도료를 도포한 MDF 목재에서 수성방염도료를 도포한 MDF 목재에서 보다 독성지수의 위험등급은 상대적으로 더 높은 위험도를 나타내었다.

도료의 주성분에 따른 편백 합판의 방염성능 비교 분석 (Comparative Analysis of Flame Retardant Performance of Japanese Cypress Plywood Based on the Main Ingredients of Fire Retardant Paint)

  • 임수희;공하성
    • 대한안전경영과학회지
    • /
    • 제25권1호
    • /
    • pp.61-66
    • /
    • 2023
  • The purpose of this study is to compare and analyze the flame retardant performance of Japanese cypress(Chamaecyparis obtusa) plywood, commonly used in indoor decoration, furniture, and tableware, by treating it with three different fire retardants with different primary ingredients. The experiment was conducted in compliance with Article 31, Paragraph 2 of the Enforcement Decree of the Fire Facilities Installation and Management Act and Articles 4 and 7-2 of the Flame Retardant Performance Standards. After flame time, after glow time, char length, and char area were measured. As a result, first, after flame time was measured at 0 seconds regardless of whether the flame retardant treatment was applied. Second, after glow time was relatively long, measuring 22.7 seconds without treatment, which is likely due to the weak fire resistance and high concentration of carbon monoxide generated by the chemical characteristics of the Japanese cypress itself. Third, it was confirmed that the effects of the primary ingredient, phosphorus, in the flame retardant treatment varied depending on the technological development of the manufacturers of the same species of Japanese cypress plywood. In the future, it is expected that the results of this study will provide fundamental data to select flame retardant treatments that show high flame retardant performance according to the botanical characteristics of the wood.

방염제의 도포량과 침지시간 차이에 따른 목재제품의 방염성능 (Flame Retardancy of Wood Products by Spreading Concentration and Impregnation Time of Flame Retardant)

  • PARK, Sohyun;HAN, Yeonjung;SON, Dong Won
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권4호
    • /
    • pp.417-430
    • /
    • 2020
  • 4종의 판상형 목재제품의 방염제 도포량과 침지시간에 따른 방염성능을 분석하기 위하여 소방청의 방염성능기준에 따라 목재제품의 탄화길이와 탄화면적을 측정하였다. 잣나무 합판, 낙엽송 합판, 편백 판재, 타공처리된 자작나무 합판에 자체 개발된 방염제를 각각 300, 500 g/㎡씩 도포하고 방염처리되지 않은 시험편과 비교하였다. 일반적으로 방염제의 도포량이 증가함에 따라 탄화길이와 탄화면적이 감소하여 방염성능이 증가하는 경향을 나타냈으나, 낙엽송 합판을 제외하고 탄화길이와 탄화면적의 감소량이 크지 않았다. 타공처리된 자작나무 합판의 침지시간에 따른 방염성능은 60분의 침지시간까지 양의 상관관계를 나타냈으나, 그 이후 점차 완만해지는 경향을 보였다. 방염제의 도포량과 침지시간에 따른 목재제품의 방염성능은 추후 방염성능 기준에 맞는 불연·준불연 목재의 생산을 위한 기초자료로 이용될 것으로 기대된다.

버티칼 브라인드와 롤 스크린의 방염성능 유지에 관한 연구 (A Study on Flame Retardant Performance of Vertical Blind and Roll Screen)

  • 정현규;조원철;이태식
    • 한국재난관리표준학회지
    • /
    • 제3권2호
    • /
    • pp.41-46
    • /
    • 2010
  • 본 연구는 최근 직물커튼의 대용으로 가장 많이 사용하고 있는 버티컬 브라인드와 롤 스크린을 대상으로 방염제품과 비 방염제품의 연소차이를 규명하여 방염의 필요성을 확인하고 방염제품의 방염성능 지속성을 실험을 통하여 규명하고자 소방대상물에 설치되어 장기간 사용한 버티컬 브라인드와 롤 스크린을 수거하여 세탁 전 후의 방염성능을 확인한다. 이 결과를 토대로 방염제품의 성능을 규명하고 외국의 방염관련 법규와 국내 방염관련 법규의 비교분석을 통하여 국내 방염법규의 확대적용 필요성과 개선점을 도출함을 목적으로 한다. 연구결과, 방염제품과 비 방염제품과의 성능과 안전성은 확연한 차이를 볼 수 있었다. 방염제품은 불꽃과 접하면 바로 연소를 하며 용융하고 단지 착화하지 않으므로 연소 확대를 막을 수 있다는 이점이 있다. 반면 비방염제품은 120 cm의 시험체가 전소하는데 불과 3분도 걸리지 않는 다는 것을 알 수 있다. 이를 실제 화재에 적용시 연소확대에 큰 차이를 보일 것이다. 내세탁성이 없는 브라인드의 경우 세탁을 하면 방염성능이 현저하게 감소할 것으로 예상을 했으나 세탁전과 비교하여 큰 차이를 보이지 않았다. 따라서 방염브라인드도 내 세탁성을 가질 수 있음을 입증하였고 엄격한 생산과정을 통한 내구성의 유지에 관심을 가져야 하겠다.

  • PDF

용접 불티 차단막의 방염 및 난연성능 평가 (An Evaluation of Flame and Fire Retardant Performance for Welding Blanket)

  • 이근원;권오승;하동명
    • 한국화재소방학회논문지
    • /
    • 제15권2호
    • /
    • pp.53-58
    • /
    • 2001
  • 본 연구에서는 조선 및 화학공장 등 산업현장에서 용접·용단작업 공정에서 비산 되는 불티에 의한 화재 예방을 위하여 불티 차단막에 관한 방염 및 난연 성능 평가를 실시하였다. 방염성능 실험결과 기존제품의 용접불티 차단막 6종 모두 충분한 방염성능을 갖고 있었다. 그러나, 용접·용단 불꽃에 의한 난연성 실험 결과 섬유유리에 수지코팅한 제품 2종은 용접·용단 불티에 대한 화재예방성능이 부족한 것으로 나타났다. 용접 불티 차단막의 최소산소지수의 국내기준은 30이상으로 고려하는 것이 좋을 것으로 사료된다. 용접 불티 차단막의 성능향상을 위한 제속적인 연구가 필요하며, 방염 및 난연성능 기술지침 개발의 기초자료로서 활용될 수 있을 것으로 사료된다.

  • PDF

용접 불티 차단막 개발을 위한 섬유류의 적정 방염처리 방안 연구 (A Study on the Treatment of Suitable Flame Retardant to the Fibers for Welding Blanket Development)

  • 이근원;김관응;이두형
    • 한국화재소방학회논문지
    • /
    • 제16권3호
    • /
    • pp.48-55
    • /
    • 2002
  • 본 연구는 용접불티 차단막 개발을 위해 섬유류의 방염처리 후 화재성능 평가를 통해 적정한 방염 처리 방안을 제시하였다. 실험재료는 시중에서 유통되고 있는 섬유류이며, 방염처리는 난연제와 방화도료를 사용하였다. 화재성능 실험은 한국과 일본 기준에 따라 수행하였다. 실험결과 방염처리된 섬유류는 방염 및 난연성능이 충분하였으며, 그들의 난연등급은 A급에서 C급으로 나타났다. 최소산소지수는 방염제로 처리된 모든 시료가 국제기준을 만족하였다. 용접불티 차단막을 수평으로 설치하여 사용할 경우에는 작업대 높이에 관계없이 난연 A급에서 C급의 성능을 가진 제품을, 수직으로 설치할 경우 난연 C급 성능을 갖는 제품을 사용하는 것이 용접불티에 의한 화재확산을 예방할 수 있을 것으로 사료된다.

MDF합판의 방염 및 연소특성에 관한 연구 (A Study on the Flame Resistance and Combustion Characteristics of MDF Plywood)

  • 김인범
    • Korean Chemical Engineering Research
    • /
    • 제52권2호
    • /
    • pp.256-260
    • /
    • 2014
  • 건축물 내부의 장식을 위해 사용되는 MDF합판은 화염의 착화를 지연시키기 위해 방염처리하도록 규정하고 있어 일반적으로 방염도료나 방염액 또는 방염필름 등을 적용하여 착화를 지연시키는데 이 때 적용하는 시료에 따라 방염성능과 연소 시 발생되는 가스의 유독성의 차이가 발생할 수 있어 본 연구에서는 MDF에 적용된 방염시료들의 방염성능 및 연소특성에 대해 비교분석하였으며 그 결과 방염성능에 부합하는 제품이 확인되었으나 방염처리방법에 따라 방염성능의 차이가 존재함을 확인할 수 있었으며 연소과정에서 발생되어지는 여러 종류의 유독가스의 영향도 함께 고려해야 할 요소임을 확인할 수 있었다.