• Title/Summary/Keyword: Flame configuration

Search Result 123, Processing Time 0.02 seconds

A Study on the Flame Configuration and Flame Stability Mechanism with a Nozzle Diameter of Laminar Lifted Jet Flame (층류제트 화염의 노즐직경에 따른 안정화 메커니즘과 화염형상에 관한 연구)

  • Kim, Tae-Kwon;Kim, Kyung-Ho;Ha, Ji-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.204-215
    • /
    • 2011
  • Flame stability is the one of the main mechanism of laminar lifted flame and flame propagation velocity becomes a yardstick to measure the flame stability. Bilge has presented the flame propagation velocity of the triple flame and the flame stability mechanism related the flame configuration and mixture fraction. However, there was not able to observe all process of flame ignition and extinction for small nozzle diameter. In this paper, we have subdivided the flame configuration and stability mechanism and classified the flame behavior with a nozzle diameter. Also we have subdivided the 'triple flame propagation opened' and the 'triple flame propagation closed' from the triple flame propagation of triple flame criterion.

Stability Enhancement by the Interaction of Diffusion Flames (다수 비예혼합 화염의 안정화 특성)

  • Kim, Jin-Sun;Lee, Byeong-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1420-1426
    • /
    • 2003
  • The stability of turbulent nonpremixed interacting flames is investigated in terms of nozzle configuration shapes and kind of fuels. Four nozzle arrangements - cross 5, matrix 8, matrix 9 and circle 8 nozzles - are used in the experiment. There are many parameters affecting flame stability in multi-nozzle flames such as nozzle separation distance, fuel flowrates and nozzle configuration etc. Key factors to enhance blowout limit are the nozzle configuration and the existence of center nozzle. Even nozzle exit velocity equal 204 m/s, flame is not extinguished when there is not a center nozzle and s/d=15.3∼27.6 in matrix-8 and circular-8 configurations. At these conditions, recirculation of burnt gas is related with stability augmentation. Fuel mole fraction measurements using laser induced fluorescence reveal lifted flame base is not located at the stoichiometric contour.

Influence of Inert Gas on the Configuration Characteristics of Premixed Turbulent Propagating Flames of Hydrogen Mixtures (수소 예혼합 난류전파화염의 화염형상 특성에 미치는 불활성 가스의 영향)

  • 나까하라마사야;키도히로유끼;김준효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.632-640
    • /
    • 2004
  • The purpose of this study is to clarify the influence of inert gas on the configuration characteristics of premixed turbulent propagating flames of hydrogen mixtures. Inert gas is changed to $N_2$, Ar, $CO_2$ and He keeping the laminar burning velocity of mixtures nearly the same value. A laser tomography technique was used to obtain the flame shape, and quantitative analyses were performed. The result shows that in the wrinkled laminar flame region, the surface area of turbulent flame is slightly dependent on the equivalence ratio and the kind of inert gas. It is also shown the region of convex part of flame toward the unburned gas is greater than that of toward the burned gas regardless of the kind of inert gas.

Stabilization Characteristics of DME-Air Diffusion Flames Depending on the Configuration of the Fuel-Air Tubes in Half Closed Combustion Spaces (반밀폐 연소공간 내 동축관 형상에 따른 DME-공기 확산화염의 안정화 특성)

  • Kim, Go-Tae;Kim, Nam-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.11
    • /
    • pp.916-923
    • /
    • 2009
  • The effects of configuration of fuel and air tubes on the flame stabilization were experimentally investigated in half-closed combustors. Flame behaviors and stabilities of methane, propane, and DME flames were compared by changing tube diameters and the locations of the fuel and air tubes. It was found that flammability limits are significantly affected by the outlet boundary condition, which disturbs compositions of burned and unburned mixtures near the flame base. And it was found that there exist critical inner tube heights, over which flame stability is determined only by the fuel flow rate. Conclusively, flame stabilization is governed by the flame propagation velocity in an ordinary mixing flow and the non-uniform mixture concentration in the combustion space which is affected by flow recirculation and the combustor configuration. The compositions of $NO_x$ and CO were compared to know basic characteristics of methane, propane, and DME flames.

A Numerical Study of the Flame Cell Dynamics in Opposed Nonpremixed Tubular Configuration (비예혼합 튜브형상내 화염셀의 거동에 대한 수치 해석적 연구)

  • Park, Hyunsu;Yoo, Chun Sang
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.175-178
    • /
    • 2014
  • The flame cell dynamics in 2-D opposed nonpremixed tubular configuration was investigated using high-fidelity numerical simulations. The diffusive-thermal instability occurs as the $Damk{\ddot{o}}hler$ number, Da, approaches the 1-D extinction limit of the tubular flames and several flame cells are generated depending on Da, and flame radius. In general, the number of flame cells are found close to the largest wave number from the linear stability analysis. It was also found from the displacement speed analysis that during the local flame extinction and cell formation, negative edge flame speed is observed due to small gain from reaction compared to large loss from diffusion.

  • PDF

The Stability of Turbulent Interacting Flames (다수 난류 비예혼합 화염의 상호작용에 관한 연구)

  • Kim, Jin-Sun;Lee, Byeong-Jun
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.453-458
    • /
    • 2001
  • The stability of turbulent nonpremixed interacting flames is investigated in terms of nozzle configuration shapes which depend on the existence of the center nozzles. Six nozzle arrangements which are cross 4, 5, 8, 9, square 8 and circular 8 nozzles are used for the experiment. Those are arranged to see the effect of the center nozzle out of multi-nozzle. There are many parameters that affect flame stability in multi-nozzle flame such as nozzle separation distance, fuel flowrates and nozzle configuration, but the most important factor is the existence of nozzles in the center area from the nozzle arrangement. As the number of nozzle in the area is reduced, more air can be entrained into the center of flame base and then tag flame is formed. In the case of circular 8 nozzles, blowout flowrates are above 5.4 times compared with that of single equivalent area nozzle.

  • PDF

The Effect of Piston Configuration on Combustion and Flame Propagation (피스톤 형상이 연소와 화염전파에 미치는 영향)

  • Jie, Myoung-Seok;Kang, Ki-Young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.5
    • /
    • pp.511-517
    • /
    • 2019
  • Two type pistons which had different configuration were made to find out the effects on combustion and flame propagation. Flame propagation speed was obtained by use of the cylinder head gasket ionization probe. Ionization Probe voltage output and flame propagation speed were increased according to the air fuel mixture ratio increase. Exhaust direction flame propagation speed was fastest in combustion chamber and next was front direction, rear direction and intake direction cause of tumbling motion in cylinder. In case of remove the valve pocket in piston, average flame propagation speed changed slowly and spark timing was advanced. Also emission was decreased.

Measurement of Soot Nano-Particle Using LIIM(Laser-Induced Ion Mobility) (LIIM(Laser-Induced Ion Mobility) 계측을 이용한 매연 나노입자 측정)

  • Lee, Eui-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.9
    • /
    • pp.1110-1116
    • /
    • 2004
  • Experimental measurements of laser-induced ion mobility(LIIM) were performed for ethene/air premixed flames operated near the soot inception point. Soot was ionized using a pulsed laser operated at 532 nm. The ionization signal was collected with a tungsten electrode located in the post-flame region. ionization signals were collected using both a single electrode and dual electrode configuration. Prior LIIM studies have focused on the use of a single biased electrode to generate the electric field, with the burner head serving as the path to ground. In many practical combustion systems, a path to ground is not readily available. To apply the LIIM diagnostic to these geometries, a dual electrode geometry must be employed. The influence of electrode configuration, flame equivalence ratio, and flame height on ionization signal detection was determined. The efficacy of the LIIM diagnostic to detect soot inception in the post-flame region of a premixed flame using a dual electrode configuration was investigated. For the different dual electrode configurations tested, the dual parallel electrode geometry was observed to be most sensitive to detect the soot inception point in a premixed flame.

An Experimental Study on the Turbulent Combustion Characteristics of Hydrocarbon Mixtures by Hydrogen Addition (수소를 첨가한 탄화수소 혼합기의 난류연소 특성에 관한 실험적 연구)

  • 김준효;한원희;키도히로유끼
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.65-72
    • /
    • 2003
  • In order to clarify turbulent combustion characteristics of hydrocarbon mixtures by hydrogen addition, turbulent burning velocities in a constant volume vessel were measured for both lean and rich hydrocarbon mixtures. Moreover, the configuration characteristics of turbulent flame was investigated in the wrinkled laminar flame region. A laser tomography technique was used to obtain the images of turbulent flame, and quantitative analyses were performed. As a result, the characteristics of turbulent burning velocity was shown a distinct difference with the addition rate of hydrogen between lean and rich mixtures. On the other hand, the obtained tomograms showed that the surface area of turbulent flame depends almost only on the turbulence intensity.

Characteristics of Interacting Lifted Flames (상호작용하는 부상화염의 특성에 관한 연구)

  • Lee, Seung;Lee, Byeong-Jun
    • 한국연소학회:학술대회논문집
    • /
    • 2000.05a
    • /
    • pp.1-8
    • /
    • 2000
  • The effects of nozzle arrangements, nozzle distances and fuel flowrates on the flame stabilities such as flame length, liftoff height and blowout characteristics are investigated experimentally. Three nozzle arrangements - diamond 4 nozzle, linear 5 nozzle, cross 5 nozzle- are used. Flame interactions result in the increase of the blowout flowrates and constant turbulent liftoff heights. The flames separated about 10 nozzle diameters are sustained as nozzle attached flames to the higher fuel flowrates than the other separation cases. Normally flames are extinguished at the lifted states. Blowout flowrates are affected by the nozzle configuration, nozzle seperation distance. Blowout flowrates for the diamond- or cross- shaped nozzle arrangements are parabolic function of nozzle distances. Maximum blowout flowrates for the 5 nozzle configuration case except linear one is about 2.9 times that of single equivalent nozzle case. Turbulent liftoff heights are not function of flowrates for the interacting flames.

  • PDF