• 제목/요약/키워드: Flame Monitoring

검색결과 57건 처리시간 0.023초

미분탄 연소의 감시 관리를 위한 화염영상 감시 및 발전용 보일러 적용시험 (The Flame Image Observation for Monitoring Management of Pulverized Coals Firings and its Feasibility Test to Boilers for Thermal Power Plant)

  • 백운보
    • 한국정밀공학회지
    • /
    • 제25권1호
    • /
    • pp.92-98
    • /
    • 2008
  • The flame image observation and analysis has been investigated for combustion monitoring and management of the pulverized coal firing for thermal power plant, especially for lower nitrogen oxide generation and safer operation. We aimed at obtaining the relationship between burner flame image information and emissions of nitrogen oxide and unburned carbon in furnace utilizing the flame image processing methods, by which we quantitatively determine the conditions of combustion on the individual homers. Its feasibility test was undertaken with Samchonpo thermal power plant #4 unit which has 24 burners, through which the system was observed to be effective for evaluating the combustion conditions and continuous monitoring to prevent future loss of ignition.

발전용 미분탄 연소 보일러 화염감시장치의 현장적용에 관한 연구 (The study of plant application at flame management system with flame monitoring for pulverized coal firing boiler of thermal power plant)

  • 백승엽;김승민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.535-537
    • /
    • 2004
  • The flame image processing and it's analysis system has been developed for optimal coal firing of thermal power plant, especially for reducing NOx and safe operations. We aimed at gaining the relationship between burner flame image, emissions of NOx and LOI(Loss on ignition) in furnace by utilizing the flame image processing methods. And the relationship determines quantitatively the conditions of combustion on the individual burners. The test was conducted on Samchonpo thermal power plant #4 unit(560MW) of KOSEP which has 24 burners. The system simplified the burner adjustment works in accordance with the real time trending of flame behavior like NOx profiles and unburned carbon profiles for individual burners. But, This kind of conventional method increases the cost as the number of burner are increased. Also there is a difficulty to measure exhausted gas of each burner because of measurement errors. This paper intends to propose the useful "Flame Monitoring System" that can find Low NOX and LOI at the upper furnace and to compare with the conventional System.

  • PDF

발전용 미분탄 보일러의 연소 상태 감시를 위한 화염 영상 처리 시스템 (Flame Image Processing System for Combustion Condition Monitoring of Pulverized Coal Firing Boilers in Thermal Power Plant)

  • 백운보;신진호
    • 제어로봇시스템학회논문지
    • /
    • 제12권11호
    • /
    • pp.1119-1123
    • /
    • 2006
  • The flame image processing and analysis system has been investigated for the optimal pulverized coal firing of thermal power plant, especially for lower nitrogen oxide generation and more safe operation. We aimed at gaining the relationship between burner flame image information and emissions of nitrogen oxide and unburned carbon in furnace utilizing the flame image processing methods, by which we quantitatively determine the condition of combustion on the individual humors. Its feasibility test was undertaken with a pilot furnace for coal firing, through which the system was observed to be effective for the monitoring of the combustion condition of pulverized coal firing boilers.

저공해 연소를 위한 화염진단장치의 특성 (Advanced flame quality indicator for emission control)

  • 김종원;이상호;박기배;심규성
    • 센서학회지
    • /
    • 제5권6호
    • /
    • pp.43-50
    • /
    • 1996
  • 대부분을 수입에 의존하고 있는 연료의 연소효율 증대, thermal NOx의 배출 저감은 화염특성 감지 및 분석을 통해서도 가능하다. 연소시스템에서 화영의 flicker에 대한 정보를 퓨리어 변환을 통해 frequency domain data 로 변환시켜 해석한 결과, 일반적으로 연소 영역의 난류강도가 커질수록 frequency와 강도는 커졌으며, 화염의 강도는 연료 공급 유량이 커질수록 항께 커졌다. 선회도가 $0{\sim}1.16$ 범위에서 커질 때, 화염의 강도는 작아졌다. 시험 연소로의 관찰구를 통하여 얻은 신호는 화염유무에 따라 그 차이가 매우 커서 화염의 존재 유무를 쉽게 알 수 있었다. 발생되는 NOx의 양은 화염강도와 밀접한 관계가 있음을 보여주었다.

  • PDF

보일러 연소관리를 위한 화염감시 시스템 개발에 관한 연구 (A Study on Flame Monitoring System Development for Combustion Management of Boilers)

  • 백운보;신진호
    • 대한기계학회논문집B
    • /
    • 제27권11호
    • /
    • pp.1587-1594
    • /
    • 2003
  • Increased energy costs have placed demands for improved combustion efficiency, high equipment availability, low maintenance and safe operation. Furthermore low NO$_x\$ modification, installed due to strict environmental legislation, requires very careful combustion management. The flame monitoring system has been developed specially to satisfy these requirements. We aimed at gaining the relationship between the burner flame image and emissions such as NO$_x$ and unburned carbon in furnace by utilizing the image processing method. For the first step of development, its possibility test was undertaken with bench furnace. The test proceeded to the second step with pilot furnace and the system was observed to be effective for evaluating the combustion conditions. By using this technology, it is possible to perform continuous monitoring of the combustion conditions and instant detection of individual changes for each burner to prevent future loss of ignition. This may contribute to the saving of burner adjusting times for the changes of loads and fuels and to the reduction of the slagging as well.

연소상태 감시용 화염 영상분석 시스템 (Flame Image Analysis Systems for Combustion Conditions Monitoring)

  • 백운보;한성현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.499-502
    • /
    • 2003
  • Increase energy costs have placed demands for improved combustion efficiency, high equipment availability, low maintenance and safe operation. Simultaneously low NOx modification, installed due to stricter environmental legislation, require very careful combustion management. We aimed at gaining the relationship between burner flame image and emissions such as NOx and unburned carbon in furnace by utilizing the image processing method. For the first step of development, its possibility test was undertaken with bench furnace. The test proceeded to the second step with pilot furnace, the system was observed to be effective for evaluating the combustion conditions. By using this technology, it is possible to perform continuous monitoring of the combustion conditions and instant detection of individual changes for each burner to prevent future loss of ignition.

  • PDF

화염감시 시스템 개발에 관한 연구 (A Study on the Flame Monitoring System Development)

  • 백운보;황이철;이승종
    • 한국정밀공학회지
    • /
    • 제21권2호
    • /
    • pp.60-66
    • /
    • 2004
  • Increased energy costs have placed demands for improved combustion efficiency, high equipment availability, low maintenance and safe operation. Simultaneously low NOx modification, installed due to stricter environmental legislations, require very careful combustion management. The flame diagnostics system has been developed specially to meet these requirements. We aimed at gaining the relationship between burner flame image and emissions such as NOx and unburned carbon in furnace by utilizing the image processing method. For the first step of development, its possibility test was undertaken with bench furnace. The test proceeded to the second step with pilot furnace, the system was observed to be effective for evaluating the combustion conditions.

핵심 객체 추출에 기반한 비주거 시설의 화재불꽃 추출에 관한 기초 연구 (A Basic Study on the Fire Flame Extraction of Non-Residential Facilities Based on Core Object Extraction)

  • 박창민
    • 디지털산업정보학회논문지
    • /
    • 제13권4호
    • /
    • pp.71-79
    • /
    • 2017
  • Recently, Fire watching and dangerous substances monitoring system has been being developed to enhance various fire related security. It is generally assumed that fire flame extraction plays a very important role on this monitoring system. In this study, we propose the fire flame extraction method of Non-Residential Facilities based on core object extraction in image. A core object is defined as a comparatively large object at center of the image. First of all, an input image and its decreased resolution image are segmented. Segmented regions are classified as the outer or the inner region. The outer region is adjacent to boundaries of the image and the rest is not. Then core object regions and core background regions are selected from the inner region and the outer region, respectively. Core object regions are the representative regions for the object and are selected by using the information about the region size and location. Each inner region is classified into foreground or background region by comparing its values of a color histogram intersection of the inner region against the core object region and the core background region. Finally, the extracted core object region is determined as fire flame object in the image. Through experiments, we find that to provide a basic measures can respond effectively and quickly to fire in non-residential facilities.

광학식 수광 프로브의 실험적 성능평가 (Experimental Performance Evaluation of Optical Receiving Probe)

  • 양영준
    • 한국산업융합학회 논문집
    • /
    • 제7권3호
    • /
    • pp.265-271
    • /
    • 2004
  • A light collecting probe named Multi-colored Integrated Receiving Optics (MICRO) is experimentally examined to verify its performance. For these purposes, the time-series signals of MICRO probe is compared with those of electro-static probe and light-guided probe by monitoring, for example. such as OH radical chemiluminescence. CH radical band and droplet Mie scattering In addition, the experiment was conducted by using laminar premixed Bunsen flame, turbulent premixed Bunsen flame and premixed spray flame, respectively. It was confirmed that the performance of MICRO probe was very useful and convenient to obtain the chemiluminescence signals from local regions in turbulent premixed Bunsen flame and premixed spray flame.

  • PDF

연소장에서의 광학식 수광프로브의 적용 (Application of Optical Receiving Probe in Combustion Field)

  • 양영준
    • 센서학회지
    • /
    • 제13권5호
    • /
    • pp.335-341
    • /
    • 2004
  • A light collecting probe named Multi-colored Integrated Receiving Optics (MICRO) is experimentally examined to verify its performance. For these purposes, the time-series signals of MICRO probe is compared with those of electrostatic probe and light-guided probe by monitoring, for example, such as OH radical chemiluminescence, CH radical band and droplet Mie scattering. In addition, the experiment was conducted by using laminar premixed Bunsen flame, turbulent premixed Bunsen flame and premixed spray flame, respectively. It was confirmed that the performance of MICRO probe was very useful and convenient to obtain the chemiluminescence signals from local regions in turbulent premixed Bunsen flame and premixed spray flame.