• 제목/요약/키워드: Fixture Design

검색결과 208건 처리시간 0.021초

Uniaxial tensile test integrated design considering mould-fixture for UHPC

  • Zhang, Xiaochen;Shen, Chao;Zhang, Xuesen;Wu, Xiangguo;Faqiang, Qiu;Mitobaba, Josue G.
    • Advances in Computational Design
    • /
    • 제7권4호
    • /
    • pp.281-295
    • /
    • 2022
  • Tensile property is one of the excellent properties of ultra-high performance concrete (UHPC), and uniaxial tensile test is an important and challenging mechanical performance test of UHPC. Traditional uniaxial tensile tests of concrete materials have inherent defects such as initial eccentricity, which often lead to cracks and failure in non-test zone, and affect the testing accuracy of tensile properties of materials. In this paper, an original integrated design scheme of mould and end fixture is proposed, which achieves seamless matching between the tension end of specimen and the test fixture, and minimizes the cumulative eccentricity caused by the difference in the matching between the tension end of specimen and the local stress concentration at the end. The stress analysis and optimization design are carried out by finite element method. The curve transition in the end of specimen is preferred compared to straight line transition. The rationality of the new integrated design is verified by uniaxial tensile test of strain hardening UHPC, in which the whole stress-strain curve was measured, including the elastic behavior before cracking,strain hardening behavior after cracking and strain softening behavior.

2-D FIELD ANALYSIS OF MAGNETIZING FIXTURE FOR STATOR MAGNET OF AIR-CLEANER DC MOTOR

  • Kim, Pill-Soo;Kim, Yong;Baek, Soo-Hyun
    • Journal of the Korean Magnetics Society
    • /
    • 제5권5호
    • /
    • pp.833-836
    • /
    • 1995
  • A capacitor discharge impulse magnetizer is used to produce a high current pulse of short duration in a magnetizing fixture for magnets of the various shapes. The problem of designing custom fixtures for magnetization has often been considered more of conventional experience than a scientific theory. Therefore, the design of magnetizingfixture has until recently been a "cut and try" process. It was common to literally blow up one or more fixtures beforeachieving the desired results. Finite element CAD package allow the design of such a fixture. Since magnetizing fixtures come in a variety of sizes and shapes, there is usually no simple analysis method that can be used to estimate the field characteristics of the fixtures. Instead, one typically uses finite element analysis. FEA program MAXWELL is the primary tool used here. The purpose of this study was a examine both theoretically and experimentally the field characteristics inside the fixture. Independent of sizes and shapes of magnetizing fixtures, the desired magnetic field can be obtained with resonable predictability. The experimental results have been achieved using a 1000[V], 22.4[KJ] capacitor discharge magnetizer and iron-core fixtures.

  • PDF

Photometric Analysis of 300w class Electrodeless flood lighting fixture (광원 고정 형태에 따른 300W급 무전극 투광등기구의 설계안 비교 연구)

  • Shin, Hyeon-Jeong;Kim, Jin-Mo;Shon, Jang-Bok
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.53-56
    • /
    • 2003
  • Photometric analysis is essential process to make design for 300W Electrodeless flood lighting fixture. But lighting source's unusual shape makes it difficult to fix in and so we supposed two kinds of installation method to solve this matter. One is to place lamp base down and second is to put lamp base side like normal HID lamps. In result, former photometric analysis came to reach a target for similar asymmetric photometric data meanwhile we can not escape work to design complicated reflector. Second analysis reached conclusion that it is more simplified reflector than former. On its lighting fixture's design, the former reflector is new and attractive breaking fixed idea but the latter is only staying in the range of existing HID lighting design.

  • PDF

A Study on planning lavatories and drinking fountains required in school -focused on the optimal numbers- (학교건축(學校建築)의 세면기(洗面器) 및 음용수(飮用水) 시설(施設) 계획(計劃)에 관한 연구(硏究) -세면기와 음수대의 적정 수 산정을 중심으로-)

  • Lee, Hwa-Ryong;Hong, Seong-Oh
    • Journal of the Korean Institute of Educational Facilities
    • /
    • 제12권1호
    • /
    • pp.14-28
    • /
    • 2005
  • Functional school planning has long been considered a fundamental concept of school design. However. in planning educational facilities, it is also important to include the dimensions of comfort, convenience and healthfulness. The school lavatories and drinking fountains are one of most crucial elements for the recent changing face in healthful school design, but the number of lavatories and drinking fountains in most schools may not be sufficient to meet current needs. This study aims to suggest a guideline in designing school sanitary fixture and propose the optimal number of lavatories and drinking fountains regarded to age and sex. The survey is conducted through questionnaires collected from 998 respondents including 300 teachers In ChungNam province. Based on the results of the survey and a formulae, it is suggested that the number of lavatories be required by ratio of 30 boys per unit fixture and 22 girls per unit fixture in the elementary, middle and high school. It is also suggested that the number of drinking fountains be required by ratio of 65 students per unit fixture. The formulae proposed in this paper can be used for other plumbing fixtures required in school facilities.

The evaluation of the simultaneous flow rate for sizing the water supply piping in the office building (사무소 건물의 급수배관경 산정을 위한 동시사용유량에 관한 연구)

  • 이용화
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제11권4호
    • /
    • pp.511-517
    • /
    • 1999
  • Determining the simultaneous flow rate in any particular section of piping is the important step in order to determine the size of water supply piping. Now we are using the diversity curve of common water closet in order to determine the simultaneous flow rate of water supply piping, but there is a difference between a determined flow rate of general water closet and that of water closet for water saving. This study aims to find out the fixture unit of a flush valve type water closet for water saving in office building, and to determine the correlation between the fixture units and peak flow rates on the basis of the probability theory. A flush valve type water closet for water saving that have a 7.5 second duration of flush operation with an average design flow rate 72 $\ell$/fin was considered. Simulation results indicate that the number 5 is shown to be reasonable to the fixture unit of water closet for water saving. And the design can be undersized considerably with the revised diversity curves using modified fixture unit.

  • PDF

Finite element analysis on the stress of supporting bone by diameters and lengths of dental implant fixture (유한요소법을 이용한 치과 임플란트 고정체의 직경과 길이에 따른 지지골의 응력 분석)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • 제38권3호
    • /
    • pp.151-156
    • /
    • 2016
  • Purpose: The dental implant should be enough to endure chewing load and it's required to have efficient design and use of implant to disperse the stress into bones properly. This study was to evaluate the stress distribution on a supporting bone by lengths and diameters of the implant fixture. Methods: The modeling and analysis of stress distribution was used for the simple molar porcelain crown model by Solidworks as FEM program. It was designed on applying with tightening torque of 20 Ncm of a abutment screw between a cement retained crown abutment and a fixture. The fixtures of experimental model used 10, 13mm by length and 4, 5mm by diameter. A external vertical loading on the two buccal cusps of crown and performed finite element analysis by 100 N. Results: The maximum von Mises stress(VMS) of all supporting bone models by fixture length and diameter were concentrated on the upper side of supporting compact bone. The maximum stress of each model under vertical load were 164.9 MPa of M410 model, and 141.2 MPa of M413 model, 54.3 MPa of M510 model, 53.6 MPa of M513 model. Conclusion: The stress reduction was increase of fixture's diameter than it's length. So it's effective to use the wider fixture as possible to the conditions of supporting bone.

Integration of Fixture Planning with Process Planning for Machining Processes (기계가공을 위한 공정계획에서의 고정계획의 통합화)

  • Kim, In-Ho;Cho, Kyu-Kab;Oh, Jung-Soo;Lee, Soo-Hoo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • 제21권1호
    • /
    • pp.51-65
    • /
    • 1995
  • This paper presents an automatic fixture planning system for machining processes of prismatic parts. A rationalized approach to integrate fixture planning with process planning is proposed and representation schemes for workpiece, part design information with features, machine tools, cutting tools and fixtures are developed. The proposed system implements two activities of fixture planning such as machining of reference surfaces and machining of features. For machining of reference surfaces, the machining sequence of reference surfaces is determined by using decision tables, which are drawn from relations of part dimension, degree of surface roughness, fixture type and its capacity, cutting tool's capacity and experienced planners' knowledge. For machining of features, a preferential machining orientation is selected for its feature which can be machined in more than one direction, and features with the same machining orientation are grouped, and the machining sequence of features is determined by interactive mode. A case study is performed to show the performance of the proposed system.

  • PDF

Study on the design of quenching fixture in hot press forming process (핫프레스포밍 공정의 냉각치구 설계에 관한 연구)

  • Lee, K.;Kwak, E.J.;Kim, H.Y.;Lee, Gi-Dong;Park, Jong-Kyu;Suh, Chang-Hee
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.337-340
    • /
    • 2009
  • In hot press forming process, the desired high strength can be obtained through quenching process after cold forming of product. The quenching process, however, accompanies undesired distortion due to the volume change during the phase transformation as well as by thermal contraction. In this study the numerical simulation with DEFORM3D-Microstructure is used to predict the deformed shape during the quenching for the quenching fixture design.

  • PDF

전기체 정적시험 치구설계 기술보고서

  • Kim, Sung-Chan;Shin, Jeong-Woo;Shim, Jae-Yeul;Hwang, In-Hee
    • Aerospace Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.32-44
    • /
    • 2002
  • This paper contains the information that describes the test fixture design and technology for full-scale airframe static test. Obtained technologies consist of determination of design load for test fixture, design technique for loading system, counterbalance system, positioning system of test article, test equipment and overload protection method. Full-scale airframe static test of advanced jet trainer was implemented using test fixture which are applied these technique.

  • PDF

Optimal Design of Fixture Layouts in Multi-Station Assembly Processes

  • Kim, Pan-Soo
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 한국경영과학회 2006년도 추계학술대회
    • /
    • pp.369-372
    • /
    • 2006
  • Optimal engineering design is challenging because nonlinear objective functions need to be evaluated in a high-dimensional space. This paper presents a data-mining aided optimal design method. The method is employed in designing an optimal multi-station fixture layout. Its benefit is demonstrated by a comparison with currently available optimization methods.

  • PDF