• Title/Summary/Keyword: Fixed dental prostheses

Search Result 169, Processing Time 0.024 seconds

COMPARISON OF MAXIMUM OCCLUSAL FORCES ON OSSEOINTEGRATED IMPLANT SUPPORTED FIXED PROSTHESES AND NATURAL TEETH (골유착성 임플랜트 지지 고정성 보철물과 자연치의 최대교합력 비교)

  • Kwon Young-Sook;Hwang Sun-Hong;Han Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.498-510
    • /
    • 2005
  • Purpose: The purpose of this study was to compare the maximum occlusal force implant prostheses to natural teeth. Material and Method: Fifty nine patients treated either with $Br{\aa}anemark$ implants and ITI implants during the recent ten years were involved in this study. The maximum occlusal force were measured with unilateral bite force recorder and dental prescale system. Results: 1. The maximum occlusal forces of the implant prostheses and natural teeth were not significantly different where measured with unilateral bite force recorder and dental prescale system. 2. The maximum occlusal forces were not significantly different between $Br{\aa}nemark$ implant and ITI implant prostheses. 3. The maximum occlusal forces of the implant prostheses had lower when compared with natural teeth during 1-6 months functional periods when measured with the unilareral bite force recorder(P<0.05) and 1-12 months functional periods when measured with the dental prescale system(P<0.05). After these periods there was not statistical significant difference between the implant prostheses and natural teeth. 4. The maximum occlusal forces of the wide diameter implant prostheses were higher than the maximum occlusal forces of the regular diameter implant prostheses when measured with dental prescale system(P<0.05), but there was no significant difference between the wide diameter and the regular diameter implant prostheses when measured with unilateral bite force recorder. 5. The maximum occlusal forces of the single implant prostheses were not significantly different with the splinting implants prostheses. 6. The maximum occlusal forces of the implant prostheses were not significantly different by age and sex. 7. There was significantly different between maximum occlusal forces measured with unilateral bite force recorder and dental prescale system(P<0.0001) but there was positive correlation(r=0.52. P<0.05). Conclusion: The maximum occlusal forces of the implant prostheses were not significantly different to natural teeth during clenching and unilateral maximum biting.

Complete mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and dental CAD-CAM (완전 무치악 환자에서 임시 의치와 치과용 CAD-CAM을 활용한 전악 고정성 임플란트 회복 증례)

  • Jeon, Sol;Yoon, Hyung-In;Lee, Jae-Hyun;Yeo, In-Sung Luke;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.100-109
    • /
    • 2022
  • Installation of dental implants at optimal angles and positions is critical in long-term stable implant-supported restorations. Surgery and prosthodontic procedures should be performed accurately as the treatment is planned. In this clinical case, Computer aided design and manufacturing technology was used not only to establish a precise surgical plan, but also to fabricate both provisional and definitive fixed prostheses. A surgical guide was designed to install the implants at proper positions for the definitive prostheses. The patient's esthetic information, which was necessary for the new provisional and definitive fixed prostheses, was obtained from the existing temporary dentures. Finally, the complete mouth fixed implant-supported rehabilitation using monolithic zirconia provided the patient with functionally and esthetically satisfactory prostheses.

A COMPARISON OF THE MASTICATORY FUNCTION BETWEEN TWO DIFFERENT TYPES OF IMPLANT SUPPORTED PROSTHESES AND COMPLETE DENTURE FOR FULLY EDENTULOUS PATIENTS

  • Lee, Jae-Hoon;Kim, Woo-Hyun;Shin, Rie-Hye;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.591-601
    • /
    • 2008
  • STATEMENT OF PROBLEM: The improvement in oral function and comfort from the dental implant appears to depend on the particular type of implant support used with the denture. The number and positioning of implants have an influence on the force transfer and subsequent stress distribution around implants. Nevertheless, a quantitative comparison has not been made between the types of implant prosthesis used with different materials compared to conventional complete denture. PURPOSE: The objective of this study is to assess the masticatory performance, bite force and impact of two different type of implant supported prostheses on oral health-related quality of life compared to conventional complete denture with GOHAI, validated oral-specific health status measures, the sieving method, and the Prescale Dental System. MATERIAL AND METHODS: From the years 1999 to 2006, a total of 30 completely edentulous patients in a single arch were selected from the Yonsei University Dental Hospital, Department of Prosthodontics and Implant Clinic in Seoul, S. Korea. Patients were divided into 3 groups of 10 each. Group HR was restored with fixed-detachable hybrid prostheses with resin teeth. Group FP had fixed dentures with porcelain teeth while Group CD had a complete denture. The masticatory performance was compared between 3 groups. RESULTS: The results showed a significant improvement in oral health-related quality of life with dental implants compared to a conventional denture in GOHAI comparison. Overall, implant prostheses showed a higher masticatory performance ($S_{50}$) and maximum bite force compared with conventional dentures (P < .05) but no differences between different implant supported prostheses (P > .05). CONCLUSION: Within the limitation of this study, the numbers of implant and material of implant prostheses does not appear to impact patient satisfaction, masticatory performance or bite force.

Clinical Evaluation of Implant-Supported Fixed Prostheses (임플란트-지지 고정성 보철물의 임상적 상태에 대한 평가)

  • Park, Chan-Yong;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Jeon, Yeong-Chan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.317-326
    • /
    • 2013
  • This study was to compare the cumulative survival rate of implant-supported fixed prostheses and to analyze association between risk factors and cumulative survival rate of implant-supported fixed prostheses. In order to assess the clinical status of implant-supported fixed prostheses, individuals who treated in the Department of Prosthodontics, Pusan National University Dental Hospital, between 2000 to 2007 were examined. The results of this study were as follows: 1. Length of service of implant-supported fixed prostheses was $6.6{\pm}32.0$ years (mean), 11.7 years (median). 2. Age and sex of patient was found to have no statistically significant influence on longevity of implant-supported fixed prostheses (P>.05). 3. Reason of tooth extraction wax found to have statistically significant influence on implant-supported fixed prostheses (P<.05). The longevity of fixed prostheses was low in tooth extraction case due to periodontal disease (median:9.0 years). 4. Location of implant-supported fixed prostheses was found to have statistically significant influence on longevity of fixed prostheses (P<.05). The longevity of fixed prostheses was low in molar region (median:8.8 years). 5. Number of units in implant-supported fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 6. Condition of opposing dentition was found to have no statistically significant influence on longevity of implant-supported fixed prostheses (P>.05). 7. Food impaction (40.5%), porcelain fracture (25.8%), screw loosening (23.6%) were frequent complications.

Evaluation of clinical status of fixed prosthesis (고정성 보철물의 임상적 상태에 대한 평가)

  • Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.99-107
    • /
    • 2009
  • Statement of problem: Restoring and replacing teeth with fixed prostheses commonly used in dental practice. Because of improper oral hygiene care and inaccurate laboratory procedure, complications of fixed prostheses were found in the mouth of patients. Although many efforts have been continually made to obtain the data of long term prognosis of fixed prostheses, it was difficult to do it. Purpose: The purpose of this study was to evaluate the clinical status of fixed prostheses. Material and methods: In order to assess the clinical status of fixed prostheses, a total of 161 individuals(aged 17-85, 99 women and 62 men with 1596 unit of fixed prostheses, and 1169 abutments) who first visited the Department of Prosthodontics, Pusan National University Hospital, between April to September, in 2007 were examined. Results and conclusion: The results of this study were as follows: 1. Length of service of fixed prostheses was $8.6{\pm}0.6$ years(mean), 10.0 years(median). 2. Location of fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses(P>.05). But, the success rate was high in posterior region and in mandible where the failure rate was high in combination(P<.05). 3. Longevity of fixed prostheses made of metal was longest(mean: $13.0{\pm}9.3$, median: 14.0), gold, precious ceramic, non-precious ceramic trailing behind(P<.05). 4. Number of units in fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses(P>.05). But, the success rate was high in Single-unit and the failure rate was high in over 3-unit(P<.05). 5. Condition of opposing dentition was found to have no statistically significant influence on longevity of fixed prostheses(P>.05). But, the success rate was high in natural dentition(P<.05). 6. Defective margin(28.2%), dental caries(23.0%), periodontal disease(19.3%), periapical disease(16.9%) were frequent complications. In 30.1% of the cases, abutment state after removing fixed prostheses was needed to be extracted.

Esthetic Full Zirconia Fixed Detachable Implant-Retained Restorations Manufactured from Monolithic Zirconia : Clinical Report (Monolithic zirconia framework으로 제작된 fixed detachable prostheses를 이용한 심미적인 임플란트 전악 수복 증례)

  • Hong, Jun-Tae;Choi, Yu-Sung;Han, Se-Jin;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.253-268
    • /
    • 2012
  • Full-mouth reconstruction of a patient using dental implants is a challenge if there is vertical and horizontal bone resorption, since this includes the gingival area and restricts the position of the implants. however, hard- and soft-tissue grafting may allow the implants to be placed into the desired position. Although it is possible to regenerate lost tissues, an alternative is to use fixed detachable prostheses that restore the function and the esthetics of the gingiva and teeth. Various material combinations including metal/acrylic, metal/ceramic, and zirconia/ceramic have been used for constructing this type of restoration. Other problems include wear, separation or fracture of the resin teeth from the metal/acrylic prosthesis, chipping or fracture of porcelain from the metal/ceramic or zirconia/ceramic prosthesis, and fracture of the framework in some free-end prostheses. With virtually unbreakable, chip-proof, life-like nature, monolithic zirconia frameworks can prospectively replace other framework materials. This clinical report describes the restoration of a patient with complete fixed detachable maxillary and mandibular prostheses made of monolithic zirconia with dental implants. The occluding surfaces were made of monolithic zirconia, to decrease the risk of chipping or fracture. The prostheses were esthetically pleasing, and no clinical complications have been reported after two years.

Tilted implants for implant-supported fixed hybrid prostheses: retrospective review

  • Woo-Hyun Seok;Pil-Young Yun;Na-Hee Chang;Young-Kyun Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.5
    • /
    • pp.278-286
    • /
    • 2023
  • Objectives: This review assessed the performance of implant-supported fixed hybrid prostheses in 21 patients who received a total of 137 implants between 2003 and 2010. The implants were evaluated for marginal bone resorption, complications, success rate, and survival rate based on their vertical angularity, type of bone graft, and measured implant stability. Materials and Methods: One-way ANOVA and chi-square tests were used to analyze the relationships among long-term evaluation factors and these variables. The mean initial bone resorption in the implant group with a vertical angle of more than 20° was 0.33 mm and mean final bone resorption was 0.76 mm. In contrast, the mean initial bone resorption in the implant group with a vertical angle of less than 10° was 1.19 mm and mean final bone resorption was 2.17 mm. Results: The results showed that mean bone resorption decreased with an increase in the vertical placement angle of the implants used in fixed hybrid prostheses, as well as in the group without additional bone grafts and those with high implant stability. The success rate of implants placed after bone grafting was found to be higher than those placed simultaneously. Conclusion: These results suggest that implant-supported fixed hybrid prostheses may be an effective treatment option for edentulous patients, and intentionally placing implants with high angularity may improve outcomes.

Marginal and internal discrepancy of 3-unit fixed dental prostheses fabricated by subtractive and additive manufacturing (절삭 및 적층 가공법으로 제작된 3본 고정성 국소의치의 변연 및 내면 적합도에 관한 연구)

  • Choi, Jae-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.7-13
    • /
    • 2020
  • Purpose: This study was to evaluate marginal and internal discrepancy of 3-unit fixed dental prostheses (FDP) fabricated by subtractive manufacturing and additive manufacturing. Materials and methods: 3-unit bridge abutments without the maxillary left second premolar were prepared (reference model) and the reference model scan data was obtained using an intraoral scanner. 3-unit fixed dental prostheses were fabricated in the following three ways: Milled 3-unit FDP (MIL), digital light processing (DLP) 3D printed 3-unit FDP (D3P), stereolithography apparatus (SLA) 3D printed 3-unit FDP (S3P). To evaluate the marginal/internal discrepancy and precision of the prosthesis, scan data were superimposed by the triple-scan protocol and the combinations calculator, respectively. Quantitative and qualitative analysis was performed using root mean square (RMS) value and color difference map in 3D analysis program (Geomagic control X). Statistical analysis was performed using the Kruskal-Wallis test (α=.05), MannWhitney U test and Bonferroni correction (α=.05/3=.017). Results: The marginal discrepancy of S3P group was superior to MIL and D3P groups, and MIL and D3P groups were similar. The D3P and S3P groups showed better internal discrepancy than the MIL group, and there was no significant difference between the D3P and S3P groups. The precision was excellent in the order of MIL, S3P, and D3P groups. Conclusion: Within the limitation of this study, the 3-unit fixed dental prostheses fabricated by additive manufacturing showed better marginal and internal discrepancy than the those of fabricated by subtractive manufacturing, but the precision was poor.

Metal Ion Released from Old Prostheses May Affect Oral Lesions: A Pilot Study

  • Ju, Hye-Min;Kim, Ji-Su;Ahn, Yong-Woo;Ok, Soo-Min;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • v.43 no.4
    • /
    • pp.131-135
    • /
    • 2018
  • Purpose: To investigate the correlation between the amount of salivary metal ions released from fixed prostheses and the period of restoration insertion, and to evaluate the correlation between the type and amount of metal ions in saliva and oral lesions (OL). Methods: Based on the oldest prosthesis, we divided patients into two groups: more than 5 years (n=19) and less than 5 years (n=10). Patients were also divided into two groups by another criteria: the one with the presence (n=15), and the one with absence (n=14) of OL, and the amounts of metal ions were examined. Metal ions-gold (Au), copper, cobalt (Co), chromium (Cr), nickel, zinc, aluminum, palladium (Pd), tin, and platinum (Pt)-were measured using laser ablation microprobe inductively coupled plasma mass spectrometry. Results: Significantly higher quantities of Co, Pt, and Pd ions were released in patients with fixed prosthesis of more than 5 years (p<0.05). Measurement of the average amount of salivary metal ions was performed on patients with and without OL - Significantly higher amounts of Cr, Pd and Au ions were released in patients with OL (p<0.05). Conclusions: Old prostheses (${\geq}5years$) released metal ions, and among them were Co, Pt and Pd ions more than others. Patients with OL showed significantly higher levels of ion release, especially Cr, Pd and Au. There was a positive correlation between the amount of a certain kind of released metal ions, especially Pd, and the development of OL. Salivary Pd ion released from old prostheses could affect the pathogenesis of OL; therefore, long-term follow-up is important.